Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Heart Vessels ; 34(3): 427-434, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30284610

RESUMO

We assessed the plaque disruption in 245 consecutive patients with acute coronary syndrome undergoing percutaneous coronary intervention. The plaque fissure was diagnosed with optical coherence tomography, and intravascular ultrasound was used to determine arterial remodeling. Of them, 26 fissures were found in this study. The definite fissure was seen in 17 (65.4%) and probable fissure was seen in 9 (34.6%) patients. In 18 (69.2%), plaque fissure component was lipidic or thin-capped fibroatheroma. Eighteen (69.2%) of fissured plaque were seen within 30 mm of coronary ostium. Combined plaque fissure with plaque rupture/erosion was seen in 21 (80.8%) cases. The isolated fissure was seen in 5 (19.2%). Compared to the maximal necrotic core site of the ruptured plaque, the fissure site showed a smaller %necrotic core (p = 0.012), however, greater in fissure site than minimal lumen area site (24.93 ± 11.50% vs 15.34 ± 10.40%, p < 0.0001). The remodeling index was higher at fissure site as compared to minimal lumen area site (1.02 ± 0.22 vs 0.94 ± 0.27; p = 0.047), but similar to the rupture plaque (p = 0.31). The frequency of positive remodeling was 34.6% (9/26) at the plaque fissure. Although the plaque fissure can be interchangeable with the rupture in acute coronary syndrome, the limited extension to the small lipid core might and less positive remodeling provoke a fissuring of the plaque. Further study is necessary to assess the plaque fissure.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Vasos Coronários/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico , Tomografia de Coerência Óptica/métodos , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/cirurgia , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Placa Aterosclerótica/complicações , Placa Aterosclerótica/cirurgia , Ruptura Espontânea , Índice de Gravidade de Doença , Ultrassonografia de Intervenção
2.
Cardiol J ; 26(5): 519-528, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29718529

RESUMO

BACKGROUND: Although the safety and efficacy of left atrial (LA) appendage (LAA) closure (LAAC) in nonvalvular atrial fibrillation (NVAF) patients have been well documented in randomized controlled trials and real-world experience, there are limited data in the literature about the impact of LAAC on cardiac remodeling. The aim of the study was to examine the impact of LAAC on cardiac functional and structural remodeling in NVAF patients. METHODS: Between March 2014 and November 2016, 47 NVAF patients who underwent LAAC were included in this study (LAAC group). A control group (non-LAAC group) was formed from 141 NVAF patients without LAAC using propensity score matching. The difference-in-difference analysis was used to evaluate the difference in cardiac remodeling between the two groups at baseline and follow-up evaluations. RESULTS: The LAAC group had a larger increase in LA dimension, volume and volume index than the non-LAAC group (+3.9 mm, p = 0.001; +9.7 mL, p = 0.006 and +5.9 mL/m2, p = 0.011, respectively). Besides, a significant increase in E and E/e' ratio was also observed in the LAAC group (+14.6 cm/s, p = 0.002 and +2.3, p = 0.028, respectively). Compared with the non-LAAC group, left ventricular (LV) ejection fraction and fractional shortening decreased in LAAC patients, but were statistically insignificant (-3.5%, p = 0.109 and -2.0%, p = 0.167, respectively). CONCLUSIONS: There were significant increases in LA size and LV filling pressure among NVAF patients after LAAC. These impacts of LAAC on cardiac functional and structural remodeling may have some clinical implications that need to be addressed in future studies.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Função do Átrio Esquerdo , Remodelamento Atrial , Cateterismo Cardíaco , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Feminino , Humanos , Masculino , Pontuação de Propensão , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Pressão Ventricular
3.
Angiology ; 70(8): 756-764, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30665308

RESUMO

OBJECTIVES: To evaluate the angiographic and intravascular ultrasound (IVUS) characteristics of coronary mismatch lesions. BACKGROUND: Better understanding about the characteristics of mismatch lesions may help to achieve more accurate lesion assessment and, thereby, to improve the outcomes of percutaneous coronary intervention (PCI). METHODS: Angiographic and IVUS data from 1369 lesions were analyzed. Mismatch lesion was defined as the difference between proximal and distal reference lumen diameters of ≥1.0 mm or ≥30% of the distal reference lumen diameter. RESULTS: The incidence of mismatch lesions was 20.1% (275/1369). Compared to nonmismatch group, mismatch group had longer lesions (21.3 [6.4] mm vs 18.4 [6.4] mm, P < .001) with smaller minimum lumen diameter (0.87 [0.29] mm vs 1.10 [0.31] mm, P < .001) and more severe diameter stenosis (78.8% [9.2%] vs 66.3% [10.3%], P < .001). On IVUS, mismatch group had larger lumen area (18.7 [5.0] vs 15.8 [5.1] mm2, P < .001) but lower plaque burden at the proximal reference segment (41.0% [9.2%] vs 45.7% [9.9%], P < .001) and smaller lumen area (4.83 [1.89] vs 7.36 [2.89] mm, P < .001) but higher plaque burden at the distal reference segment (42.9% [10.4%] vs 41.4% [10.1%], P = .023). Multivariable logistic regression analysis showed that mismatch lesions were frequently accompanied by diffuse lesions (odds ratio [OR] = 2.50; 95% confidence interval [CI]: 1.83-3.40; P < .001), bifurcation lesions (OR = 5.83; 95% CI: 4.40-7.74; P < .001), and lesions with a low TIMI flow grade (OR = 1.70; 95% CI: 1.08-2.67; P = .022) or severe diameter stenosis (OR = 3.05; 95% CI: 2.10-4.43; P < .001). CONCLUSIONS: Mismatch lesions are quite common and characterized by greater lesion complexity compared with nonmismatch lesions. Further studies may be necessary to address the impact of this lesion type on the outcome of PCI.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/patologia , Vasos Coronários/patologia , Ultrassonografia de Intervenção , Adulto , Idoso , Angiografia Coronária/métodos , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Valor Preditivo dos Testes , Ultrassonografia de Intervenção/métodos
4.
Cardiol Res ; 9(6): 385-391, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30627291

RESUMO

Even cardiac surgery has been accepted as the standard therapy for Lutembacher syndrome, a combination of congenital ostium secundum atrial septal defect (ASD) and acquired mitral valve stenosis (MVS), it also owns many limitations and disadvantages. Therefore, seeking for a less invasive therapy with the same efficacy may be worthwhile. Thanks to the development in technology and experience gaining in cardiovascular intervention, the combination of the two proved effective procedures, including percutaneous MVS treatment using balloon valvuloplasty and percutaneous ASD closure using atrial septal occluders, can be utilized as an attractive alternative therapy for these conditions. Here, we present a successful percutaneous intervention in Lutembacher syndrome using the combination of mitral balloon valvuloplasty and ASD device closure and thoroughly review the experience of using this combined procedure existing in the literature.

5.
PLoS One ; 13(11): e0206535, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30439981

RESUMO

OBJECTIVES: To assess the safety and efficacy of percutaneous closure of perimembranous ventricular septal defect (PmVSD) using patent ductus arteriosus (PDA) occluders. BACKGROUND: Widespread use of conventional PmVSD closure devices has been limited by unacceptable high rate of complete heart block (CHB). The elegant design of PDA occluders is supposed to ease implantation, increase closure rate and minimize damage to adjacent structures. Thus, PDA occluders may reduce complications, especially the CHB, and offer a good alternative for PmVSD closure. METHOD: From September 2008 to October 2015, patients who underwent attempted percutaneous VSD closure using PDA occluders were included in the study. Patient demographics, echocardiography measurements, procedure details and follow-up data until October 2017 were collected. RESULTS: In total, 321 patients with a mean age of 15.5±12.6 years and mean a weight of 33.3±20.5 kg were included in this study. The mean defect size was 4.8±2.1 mm. Implantation was successful in 307 (95.6%) patients. The median follow-up time was 63 months (24 to 108 months). The closure rates were 89.5%, 91.5%, and 99.3% after the procedure 24 hours, 6 months and 2 years, respectively. Major complications occurred in 5 (1.7%) patients during the procedure and follow-up, including persistent CHB in 2 (0.7%) patients and device embolization in 3 (1.0%) patients. No death, disability, or other major complication was detected. CONCLUSION: Percutaneous closure of PmVSD using PDA occluders is feasible, safe and efficacious in selected patients.


Assuntos
Comunicação Interventricular/cirurgia , Dispositivo para Oclusão Septal , Adolescente , Criança , Pré-Escolar , Eletrocardiografia , Feminino , Seguimentos , Comunicação Interventricular/diagnóstico , Comunicação Interventricular/fisiopatologia , Humanos , Masculino , Segurança do Paciente , Complicações Pós-Operatórias , Desenho de Prótese , Resultado do Tratamento
6.
Sci Rep ; 7(1): 11276, 2017 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-28900224

RESUMO

Solving combinatorial optimization problems is challenging. Mapping onto the ground-state search problem of the Ising Hamiltonian is a promising approach in this field, where the components of the optimization set are modeled as artificial spin units. The search for a suitable physical system to realize these spin units is an active area of research. In this work, we have demonstrated a scheme to model the Ising Hamiltonian with multiferroic oxide/nanomagnet units. Although nanomagnet-based implementation has been shown before, we have utilized the magnetoelectric effect of the multiferroics to make voltagecontrolled spin units with less current flow in the network. Moreover, we have proposed a unique approach of configuring the coupling network of the system directly from the Ising Hamiltonian of a traveling salesman problem (TSP). We have developed a coupled micromagnetic simulation framework and solved TSPs of size 26-city and 15-city with an accuracy of 100% for the latter.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA