Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 145(12)2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37796636

RESUMO

Model reproducibility is a point of emphasis for the National Institutes of Health (NIH) and in science, broadly. As the use of computational modeling in biomechanics and orthopedics grows, so does the need to assess the reproducibility of modeling workflows and simulation predictions. The long-term goal of the KneeHub project is to understand the influence of potentially subjective decisions, thus the modeler's "art", on the reproducibility and predictive uncertainty of computational knee joint models. In this paper, we report on the model calibration phase of this project, during which five teams calibrated computational knee joint models of the same specimens from the same specimen-specific joint mechanics dataset. We investigated model calibration approaches and decisions, and compared calibration workflows and model outcomes among the teams. The selection of the calibration targets used in the calibration workflow differed greatly between the teams and was influenced by modeling decisions related to the representation of structures, and considerations for computational cost and implementation of optimization. While calibration improved model performance, differences in the postcalibration ligament properties and predicted kinematics were quantified and discussed in the context of modeling decisions. Even for teams with demonstrated expertise, model calibration is difficult to foresee and plan in detail, and the results of this study underscore the importance of identification and standardization of best practices for data sharing and calibration.


Assuntos
Articulação do Joelho , Fluxo de Trabalho , Reprodutibilidade dos Testes , Calibragem , Fenômenos Biomecânicos , Simulação por Computador , Análise de Elementos Finitos
2.
J Arthroplasty ; 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38061399

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) implants have continued to evolve to accommodate new understandings of knee mechanics. The medial-pivot implant is a newer design, which is intended to limit anterior-posterior translation in the medial compartment while allowing lateral compartment translation. However, evidence for a generalized medial-pivot characteristic across all activities is limited. The purpose of the study was to quantify and compare in vivo knee joint kinematics using high-speed stereo radiography during activities of daily living in patients who have undergone a TKA with a cruciate sacrificing medial-pivot implant to age-matched and sex-matched native controls. METHODS: Fifteen participants (7 patients, 4 women, mean age 70 years and 8 nonsymptomatic controls, 4 women, mean age 64 years) performed 6 functional tasks in high-speed stereo radiography: deep-knee lunge, chair rise, step down, gait, gait with 90° turn, and seated knee extension. Translational differences between groups (surgical versus control) were assessed for the medial and lateral condyle, while pivot location was normalized to subject-specific tibial plateau geometry. RESULTS: The surgical cohort displayed a more constrained medial condyle that provided greater stability of the medial compartment and did not result in the paradoxical anterior translation at mid-flexion angles during weight-bearing activities, but was associated with less condylar translation than native knees. Additionally, the transverse tibial pivot location occurs most commonly in the middle third of the tibial plateau and secondarily on the medial third. CONCLUSIONS: Some variability in pivot location occurs between activities and is more in nonsymptomatic, native knee controls.

3.
J Biomech Eng ; 143(6)2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33537727

RESUMO

The use of computational modeling to investigate knee joint biomechanics has increased exponentially over the last few decades. Developing computational models is a creative process where decisions have to be made, subject to the modelers' knowledge and previous experiences, resulting in the "art" of modeling. The long-term goal of the KneeHub project is to understand the influence of subjective decisions on the final outcomes and the reproducibility of computational knee joint models. In this paper, we report on the model development phase of this project, investigating model development decisions and deviations from initial modeling plans. Five teams developed computational knee joint models from the same dataset, and we compared each teams' initial uncalibrated models and their model development workflows. Variations in the software tools and modeling approaches were found, resulting in differences such as the representation of the anatomical knee joint structures in the model. The teams consistently defined the boundary conditions and used the same anatomical coordinate system convention. However, deviations in the anatomical landmarks used to define the coordinate systems were present, resulting in a large spread in the kinematic outputs of the uncalibrated models. The reported differences and similarities in model development and simulation presented here illustrate the importance of the "art" of modeling and how subjective decision-making can lead to variation in model outputs. All teams deviated from their initial modeling plans, indicating that model development is a flexible process and difficult to plan in advance, even for experienced teams.


Assuntos
Articulação do Joelho
4.
J Biomech Eng ; 143(11)2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34041519

RESUMO

Accurately capturing the bone and cartilage morphology and generating a mesh remains a critical step in the workflow of computational knee joint modeling. Currently, there is no standardized method to compare meshes of different element types and nodal densities, making comparisons across research teams a significant challenge. The aim of this paper is to describe a method to quantify differences in knee joint bone and cartilages meshes, independent of bone and cartilage mesh topology. Bone mesh-to-mesh distances, subchondral bone boundaries, and cartilage thicknesses from meshes of any type of mesh are obtained using a series of steps involving registration, resampling, and radial basis function fitting after which the comparisons are performed. Subchondral bone boundaries and cartilage thicknesses are calculated and visualized in a common frame of reference for comparison. The established method is applied to models developed by five modeling teams. Our approach to obtain bone mesh-to-mesh distances decreased the divergence seen in selecting a reference mesh (i.e., comparing mesh A-to-B versus mesh B-to-A). In general, the bone morphology was similar across teams. The cartilage thicknesses for all models were calculated and the mean absolute cartilage thickness difference was presented, the articulating areas had the best agreement across teams. The teams showed disagreement on the subchondral bone boundaries. The method presented in this paper allows for objective comparisons of bone and cartilage geometry that is agnostic to mesh type and nodal density.


Assuntos
Articulação do Joelho
5.
J Biomech Eng ; 142(8)2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31913450

RESUMO

Dynamic, in vivo evaluations of knee mechanics are important for understanding knee injury and repair, and developing successful treatments. Computational models have been used with in vivo experiments to quantify joint mechanics, but they are typically not predictive. The current study presents a novel integrated approach with high-speed stereo radiography, musculoskeletal modeling, and finite element (FE) modeling for evaluation of subject-specific, in vivo knee mechanics in a healthy subject performing a seated knee extension and weight-bearing lunge. Whole-body motion capture, ground reaction forces, and radiography-based kinematics were used to drive musculoskeletal and predictive FE models for load-controlled simulation of in vivo knee mechanics. A predictive simulation of knee mechanics was developed in four stages: (1) in vivo measurements of one subject performing a lunge and a seated knee extension, (2) rigid-body musculoskeletal modeling to determine muscle forces, (3) FE simulation of knee extension for knee-ligament calibration, and (4) predictive FE simulation of a lunge. FE models predicted knee contact and ligament mechanics and evaluated the impact of cruciate ligament properties on joint kinematics and loading. Calibrated model kinematics demonstrated good agreement to the experimental motion with root-mean-square differences of tibiofemoral flexion-extension <3 deg, internal-external <4 deg, and anterior-posterior <2 mm. Ligament reference strain and attachment locations were the most critical properties in the calibration process. The current work advances previous in vivo knee modeling through simulation of dynamic activities, modeling of subject-specific knee behavior, and development of a load-controlled knee model.


Assuntos
Análise de Elementos Finitos , Articulação do Joelho , Fenômenos Biomecânicos , Humanos , Amplitude de Movimento Articular , Suporte de Carga
6.
J Sports Sci ; 38(23): 2677-2687, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32715955

RESUMO

Sport-related concussion return to play (RTP) decisions are largely based on the resolution of self-reported symptoms and neurocognitive function. Some evaluators also incorporate balance; however, an objective approach to balance that can detect effects beyond the acute condition is warranted. The purpose of this study is to examine linear measures of biomechanical balance up to 6 months post-concussion, and to present preliminary diagnostic thresholds useful for RTP. Each concussed athlete participated in instrumented standing balance tasks at 4 timepoints post-concussion. The measures from concussed athletes were compared to the sport-matched non-concussed athlete group at each timepoint. Centre of pressure (COP) mediolateral (ML) velocity in double-leg stance on a hard surface discriminated well between non-concussed and concussed athletes. COP anterior-posterior (AP) velocity in tandem stance on foam showed sensitivity to concussion. Sixty per cent of athletes at 6 months post-concussion did not recover to within the proposed COP ML velocity threshold in double-leg stance on a hard surface. Seventy-one per cent of athletes at 6 months post-concussion did not recover to within the COP AP velocity threshold in tandem stance on foam. This lack of recovery potentially indicates vestibular and motor control impairments long past the typical period of RTP.


Assuntos
Traumatismos em Atletas/fisiopatologia , Concussão Encefálica/fisiopatologia , Equilíbrio Postural , Fenômenos Biomecânicos , Feminino , Seguimentos , Humanos , Masculino , Recuperação de Função Fisiológica , Volta ao Esporte , Posição Ortostática , Análise e Desempenho de Tarefas , Adulto Jovem
7.
J Appl Biomech ; 36(6): 423-435, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32971516

RESUMO

People developing transient low back pain during standing have altered control of their spine and hips during standing tasks, but the transfer of these responses to other tasks has not been assessed. This study used video fluoroscopy to assess lumbar spine intervertebral kinematics of people who do and do not develop standing-induced low back pain during a seated chair-tilting task. A total of 9 females and 8 males were categorized as pain developers (5 females and 3 males) or nonpain developers (4 females and 5 males) using a 2-hour standing exposure; pain developers reported transient low back pain and nonpain developers did not. Participants were imaged with sagittal plane fluoroscopy at 25 Hz while cyclically tilting their pelvises anteriorly and posteriorly on an unstable chair. Intervertebral angles, relative contributions, and anterior-posterior translations were measured for the L3/L4, L4/L5, and L5/S1 joints and compared between sexes, pain groups, joints, and tilting directions. Female pain developers experienced more extension in their L5/S1 joints in both tilting directions compared with female nonpain developers, a finding not present in males. The specificity in intervertebral kinematics to sex-pain group combinations suggests that these subgroups of pain developers and nonpain developers may implement different control strategies.

8.
J Biomech Eng ; 141(7)2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31166589

RESUMO

Recent explorations of knee biomechanics have benefited from computational modeling, specifically leveraging advancements in finite element analysis and rigid body dynamics of joint and tissue mechanics. A large number of models have emerged with different levels of fidelity in anatomical and mechanical representation. Adapted modeling and simulation processes vary widely, based on justifiable choices in relation to anticipated use of the model. However, there are situations where modelers' decisions seem to be subjective, arbitrary, and difficult to rationalize. Regardless of the basis, these decisions form the "art" of modeling, which impact the conclusions of simulation-based studies on knee function. These decisions may also hinder the reproducibility of models and simulations, impeding their broader use in areas such as clinical decision making and personalized medicine. This document summarizes an ongoing project that aims to capture the modeling and simulation workflow in its entirety-operation procedures, deviations, models, by-products of modeling, simulation results, and comparative evaluations of case studies and applications. The ultimate goal of the project is to delineate the art of a cohort of knee modeling teams through a publicly accessible, transparent approach and begin to unravel the complex array of factors that may lead to a lack of reproducibility. This manuscript outlines our approach along with progress made so far. Potential implications on reproducibility, on science, engineering, and training of modeling and simulation, on modeling standards, and on regulatory affairs are also noted.


Assuntos
Articulação do Joelho/fisiologia , Fenômenos Mecânicos , Modelos Biológicos , Fenômenos Biomecânicos , Humanos
9.
J Arthroplasty ; 34(5): 974-980, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30777625

RESUMO

BACKGROUND: Patellofemoral complications may cause pain and discomfort, sometimes leading to revision surgery for total knee arthroplasty patients, and patellar implant design has an impact on function of the reconstructed knee. The purpose of this in vivo biomechanics study was to understand the kinematic, functional, strength, and patient-reported outcome data of patients with anatomic and dome patellar implants. METHODS: Satisfactory age-matched, gender-matched, and body mass index-matched patients who underwent rotating-platform total knee arthroplasty from one joint replacement system with either dome (n = 16) or anatomic (n = 16) patellar components were tested in a human motion laboratory using high-speed stereoradiography during an unweighted seated knee extension and a weight-bearing lunge activity. Patellar kinematics, range of motion, strength, and patient-reported outcomes were compared between subjects with anatomic or dome component geometry. RESULTS: Both groups of patients achieved similar functional knee range of motion and reported similar outcomes and satisfaction. On average, patients with the anatomic component had 36% greater extensor strength compared with dome subjects. Patients with anatomic patellar components demonstrated significantly greater flexion of the patella relative to the femur and lower external rotation during the weighted lunge activity. CONCLUSIONS: Relative to the modified dome geometry, patients with anatomic patellar geometry achieved greater patellar flexion which may better replicate normal patellar motion. Patients with anatomic implants may regain more extensor strength compared to patients with dome implants due to geometric differences in the patellar component designs.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Patela/fisiopatologia , Idoso , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Feminino , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Patela/cirurgia , Medidas de Resultados Relatados pelo Paciente , Desenho de Prótese , Amplitude de Movimento Articular , Rotação
10.
J Biomech Eng ; 138(3): 4032379, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26720096

RESUMO

Musculoskeletal models are powerful tools that allow biomechanical investigations and predictions of muscle forces not accessible with experiments. A core challenge modelers must confront is validation. Measurements of muscle activity and joint loading are used for qualitative and indirect validation of muscle force predictions. Subject-specific models have reached high levels of complexity and can predict contact loads with surprising accuracy. However, every deterministic musculoskeletal model contains an intrinsic uncertainty due to the high number of parameters not identifiable in vivo. The objective of this work is to test the impact of intrinsic uncertainty in a scaled-generic model on estimates of muscle and joint loads. Uncertainties in marker placement, limb coronal alignment, body segment parameters, Hill-type muscle parameters, and muscle geometry were modeled with a global probabilistic approach (multiple uncertainties included in a single analysis). 5-95% confidence bounds and input/output sensitivities of predicted knee compressive loads and varus/valgus contact moments were estimated for a gait activity of three subjects with telemetric knee implants from the "Grand Challenge Competition." Compressive load predicted for the three subjects showed confidence bounds of 333 ± 248 N, 408 ± 333 N, and 379 ± 244 N when all the sources of uncertainty were included. The measured loads lay inside the predicted 5-95% confidence bounds for 77%, 83%, and 76% of the stance phase. Muscle maximum isometric force, muscle geometry, and marker placement uncertainty most impacted the joint load results. This study demonstrated that identification of these parameters is crucial when subject-specific models are developed.


Assuntos
Articulação do Joelho/fisiologia , Modelos Biológicos , Incerteza , Artroplastia do Joelho , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/cirurgia , Músculos/fisiologia , Modelagem Computacional Específica para o Paciente , Caminhada/fisiologia , Suporte de Carga
11.
J Biomech Eng ; 138(8)2016 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-27306137

RESUMO

Modeling complex knee biomechanics is a continual challenge, which has resulted in many models of varying levels of quality, complexity, and validation. Beyond modeling healthy knees, accurately mimicking pathologic knee mechanics, such as after cruciate rupture or meniscectomy, is difficult. Experimental tests of knee laxity can provide important information about ligament engagement and overall contributions to knee stability for development of subject-specific models to accurately simulate knee motion and loading. Our objective was to provide combined experimental tests and finite-element (FE) models of natural knee laxity that are subject-specific, have one-to-one experiment to model calibration, simulate ligament engagement in agreement with literature, and are adaptable for a variety of biomechanical investigations (e.g., cartilage contact, ligament strain, in vivo kinematics). Calibration involved perturbing ligament stiffness, initial ligament strain, and attachment location until model-predicted kinematics and ligament engagement matched experimental reports. Errors between model-predicted and experimental kinematics averaged <2 deg during varus-valgus (VV) rotations, <6 deg during internal-external (IE) rotations, and <3 mm of translation during anterior-posterior (AP) displacements. Engagement of the individual ligaments agreed with literature descriptions. These results demonstrate the ability of our constraint models to be customized for multiple individuals and simultaneously call attention to the need to verify that ligament engagement is in good general agreement with literature. To facilitate further investigations of subject-specific or population based knee joint biomechanics, data collected during the experimental and modeling phases of this study are available for download by the research community.


Assuntos
Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiopatologia , Ligamentos Articulares/fisiopatologia , Modelos Biológicos , Amplitude de Movimento Articular , Suporte de Carga , Cadáver , Cartilagem Articular/fisiopatologia , Simulação por Computador , Módulo de Elasticidade , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico , Resistência à Tração
12.
Med Eng Phys ; 126: 104136, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621835

RESUMO

Computer representations of three-dimensional (3D) geometries are crucial for simulating systems and processes in engineering and science. In medicine, and more specifically, biomechanics and orthopaedics, obtaining and using 3D geometries is critical to many workflows. However, while many tools exist to obtain 3D geometries of organic structures, little has been done to make them usable for their intended medical purposes. Furthermore, many of the proposed tools are proprietary, limiting their use. This work introduces two novel algorithms based on Generalized Regression Neural Networks (GRNN) and 4 processes to perform mesh morphing and overclosure adjustment. These algorithms were implemented, and test cases were used to validate them against existing algorithms to demonstrate improved performance. The resulting algorithms demonstrate improvements to existing techniques based on Radial Basis Function (RBF) networks by converting to GRNN-based implementations. Implementations in MATLAB of these algorithms and the source code are publicly available at the following locations: https://github.com/thor-andreassen/femors; https://simtk.org/projects/femors-rbf; https://www.mathworks.com/matlabcentral/fileexchange/120353-finite-element-morphing-overclosure-reduction-and-slicing.


Assuntos
Algoritmos , Redes Neurais de Computação , Análise de Elementos Finitos , Software , Fenômenos Biomecânicos
13.
Clin Biomech (Bristol, Avon) ; 120: 106350, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39317133

RESUMO

BACKGROUND: Restoring medial knee pivot kinematics post-total knee arthroplasty is widely recognized to enhance patient satisfaction. Our study investigates the kinematics of patients who received posterior stabilized implants via robotic-arm assisted surgery, specifically analyzing effects of implant alignment and soft tissue balance on pivot location. METHODS: Twelve high-functioning patients with unilateral posterior stabilizing knee implants underwent CT-guided robotic-arm assisted surgery. We then evaluated their knee kinematics using stereo radiography during gait, stair descent, lunge, seated knee extension and leg press. Femoral low-point condylar kinematics were used to calculate the transverse center of rotation, or pivot, using principal component analysis. Linear mixed effects regression was used to identify surgical parameters that influence pivot location across a flexion range. FINDINGS: Across all five activities a central pivot pattern emerged as the primary pivot location (40 %) followed by medial (25 %), no pivot (22 %) and lateral (14 %). Tibial medial resection depth and Tibial implant flexion-extension placement were significantly associated with shifting the pivot location laterally prior to cam-post engagement. Femoral implant external-internal implant placement, and medial compartment laxity in extension were significantly associated with shifting the pivot location laterally during the cam-post engagement, while femoral distal-lateral resection depth was associated with a medial shift. INTERPRETATION: Central and medial pivot locations are predominant in patients with posterior stabilized total knee arthroplasty, facilitated by robotic-arm assisted surgery. Despite significant associations between surgical parameters such as tibial medial resection depth and lateral compartment laxity with medial pivot, these variables explained a small portion of the variability in pivot location. This suggests that while surgical precision influences pivot kinematics, individual patient factors may play a more critical role, suggesting a need for further research into patient-specific biomechanics to optimize post-surgical outcomes.

14.
Artigo em Inglês | MEDLINE | ID: mdl-37966863

RESUMO

This paper presents a novel computational framework for neural-driven finite element muscle models, with an application to amyotrophic lateral sclerosis (ALS). The multiscale neuromusculoskeletal (NMS) model incorporates physiologically accurate motor neurons, 3D muscle geometry, and muscle fiber recruitment. It successfully predicts healthy muscle force and tendon elongation and demonstrates a progressive decline in muscle force due to ALS, dropping from 203 N (healthy) to 155 N (120 days after ALS onset). This approach represents a preliminary step towards developing integrated neural and musculoskeletal simulations to enhance our understanding of neurodegenerative and neurodevelopmental conditions through predictive NMS models.

15.
Sci Data ; 10(1): 34, 2023 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-36653365

RESUMO

Models and simulations of human function impact medicine and medical technology. Particularly, musculoskeletal modeling provides an avenue for insight into the human body, which might not be otherwise possible. However, reaching the ultimate goal of functional multi-scale human models has been slowed by the lack of freely available datasets of anatomical models and geometries. Moreover, female-specific geometries have been neglected with a widespread emphasis on male geometry. To help realize this goal, we have developed and shared complete three-dimensional musculoskeletal geometries extracted from the National Libraries of Medicine Visible Human Female and Male cryosections. Muscle, bone, cartilage, ligament, and fat from the pelvis to the ankle were digitized and exported. These geometries provide a foundation for continued work in human musculoskeletal simulation with high-fidelity deformable tissues that enable a better understanding of normal function and the evaluation of pathologies and treatments. This work is novel as it includes both the male and female Visible Human specimens, outputs at multiple levels of post-processing for maximum data reuse, and is publicly available.


Assuntos
Extremidade Inferior , Feminino , Humanos , Masculino , Osso e Ossos , Simulação por Computador , Extremidade Inferior/anatomia & histologia , Extremidade Inferior/fisiologia
16.
Front Bioeng Biotechnol ; 11: 1153692, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37274172

RESUMO

Skeletal muscles have a highly organized hierarchical structure, whose main function is to generate forces for movement and stability. To understand the complex heterogeneous behaviors of muscles, computational modeling has advanced as a non-invasive approach to evaluate relevant mechanical quantities. Aiming to improve musculoskeletal predictions, this paper presents a framework for modeling 3D deformable muscles that includes continuum constitutive representation, parametric determination, model validation, fiber distribution estimation, and integration of multiple muscles into a system level for joint motion simulation. The passive and active muscle properties were modeled based on the strain energy approach with Hill-type hyperelastic constitutive laws. A parametric study was conducted to validate the model using experimental datasets of passive and active rabbit leg muscles. The active muscle model with calibrated material parameters was then implemented to simulate knee bending during a squat with multiple quadriceps muscles. A computational fluid dynamics (CFD) fiber simulation approach was utilized to estimate the fiber arrangements for each muscle, and a cohesive contact approach was applied to simulate the interactions among muscles. The single muscle simulation results showed that both passive and active muscle elongation responses matched the range of the testing data. The dynamic simulation of knee flexion and extension showed the predictive capability of the model for estimating the active quadriceps responses, which indicates that the presented modeling pipeline is effective and stable for simulating multiple muscle configurations. This work provided an effective framework of a 3D continuum muscle model for complex muscle behavior simulation, which will facilitate additional computational and experimental studies of skeletal muscle mechanics. This study will offer valuable insight into the future development of multiscale neuromuscular models and applications of these models to a wide variety of relevant areas such as biomechanics and clinical research.

17.
J Biomech ; 149: 111487, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36868041

RESUMO

Representative data of asymptomatic, native-knee kinematics is important when studying changes in knee function across the lifespan. High-speed stereo radiography (HSSR) provides a reliable measure of knee kinematics to <1 mm of translation and 1° of rotation, but studies often have limited statistical power to make comparisons between groups or measure the contribution of individual variability. The purpose of this study is to examine in vivo condylar kinematics to quantify the transverse center-of-rotation, or pivot, location across the flexion range and challenge the medial-pivot paradigm in asymptomatic knee kinematics. We quantified the pivot location during supine leg press, knee extension, standing lunge, and gait for 53 middle-aged and older adults (27 men; 26 women: 50.8 ± 7.0 yrs, 1.75 ± 0.1 m, 79.1 ± 15.4 kg). A central- to medial-pivot location was identified for all activities with increased knee flexion associated with posterior translation of the center-of-rotation. The association between knee angle and anterior-posterior center-of-rotation location was not as strong as the relation between medial-lateral and anterior-posterior location, excluding gait. The Pearson's correlation for gait was stronger between knee angle and anterior-posterior center-of-rotation location (P < 0.001) than medial-lateral and anterior-posterior location (P = 0.0122). Individual variability accounted for a measurable proportion in variance explained of center-of-rotation location. Unique to gait, the lateral translation of center-of-rotation location resulted in the anterior translation of center-of-rotation at <10° knee flexion. Furthermore, no association between vertical ground-reaction force and center-of-rotation was identified.


Assuntos
Marcha , Articulação do Joelho , Masculino , Pessoa de Meia-Idade , Feminino , Humanos , Idoso , Articulação do Joelho/diagnóstico por imagem , Rotação , Grupo Social , Posição Ortostática
18.
J Orthop Res ; 41(2): 325-334, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35502762

RESUMO

Reproducible research serves as a pillar of the scientific method and is a foundation for scientific advancement. However, estimates for irreproducibility of preclinical science range from 75% to 90%. The importance of reproducible science has not been assessed in the context of mechanics-based modeling of human joints such as the knee, despite this being an area that has seen dramatic growth. Framed in the context of five experienced teams currently documenting knee modeling procedures, the aim of this study was to evaluate reporting and the perceived potential for reproducibility across studies the teams viewed as important contributions to the literature. A cohort of studies was selected by polling, which resulted in an assessment of nine studies as opposed to a broader analysis across the literature. Using a published checklist for reporting of modeling features, the cohort was evaluated for both "reporting" and their potential to be "reproduced," which was delineated into six major modeling categories and three subcategories. Logistic regression analysis revealed that for individual modeling categories, the proportion of "reported" occurrences ranged from 0.31, 95% confidence interval (CI) [0.23, 0.41] to 0.77, 95% CI: [0.68, 0.86]. The proportion of whether a category was perceived as "reproducible" ranged from 0.22, 95% CI: [0.15, 0.31] to 0.44, 95% CI: [0.35, 0.55]. The relatively low ratios highlight an opportunity to improve reporting and reproducibility of knee modeling studies. Ongoing efforts, including our findings, contribute to a dialogue that facilitates adoption of practices that provide both credibility and translation possibilities.


Assuntos
Articulação do Joelho , Joelho , Humanos , Fenômenos Biomecânicos , Reprodutibilidade dos Testes
19.
J Orthop Res ; 41(12): 2569-2578, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37350016

RESUMO

Stakeholders in the modeling and simulation (M&S) community organized a workshop at the 2019 Annual Meeting of the Orthopaedic Research Society (ORS) entitled "Reproducibility in Modeling and Simulation of the Knee: Academic, Industry, and Regulatory Perspectives." The goal was to discuss efforts among these stakeholders to address irreproducibility in M&S focusing on the knee joint. An academic representative from a leading orthopedic hospital in the United States described a multi-institutional, open effort funded by the National Institutes of Health to assess model reproducibility in computational knee biomechanics. A regulatory representative from the United States Food and Drug Administration indicated the necessity of standards for reproducibility to increase utility of M&S in the regulatory setting. An industry representative from a major orthopedic implant company emphasized improving reproducibility by addressing indeterminacy in personalized modeling through sensitivity analyses, thereby enhancing preclinical evaluation of joint replacement technology. Thought leaders in the M&S community stressed the importance of data sharing to minimize duplication of efforts. A survey comprised 103 attendees revealed strong support for the workshop and for increasing emphasis on computational modeling at future ORS meetings. Nearly all survey respondents (97%) considered reproducibility to be an important issue. Almost half of respondents (45%) tried and failed to reproduce the work of others. Two-thirds of respondents (67%) declared that individual laboratories are most responsible for ensuring reproducible research whereas 44% thought that journals are most responsible. Thought leaders and survey respondents emphasized that computational models must be reproducible and credible to advance knee M&S.


Assuntos
Articulação do Joelho , Estados Unidos , Reprodutibilidade dos Testes , Simulação por Computador , Fenômenos Biomecânicos
20.
Front Bioeng Biotechnol ; 10: 820196, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35497367

RESUMO

Quantification of natural knee kinematics is essential for the assessment of joint function in the diagnosis of pathologies. Combined measurements of tibiofemoral and patellofemoral joint kinematics are necessary because knee pathologies, such as progression of osteoarthritis and patellar instability, are a frequent concern in both articulations. Combined measurement of tibiofemoral and patellofemoral kinematics also enables calculation of important quantities, specifically patellar tendon angle, which partly determines the loading vector at the tibiofemoral joint and patellar tendon moment arm. The goals of this research were to measure the differences in tibiofemoral and patellofemoral kinematics, patellar tendon angle (PTA), and patellar tendon moment arm (PTMA) that occur during non-weight-bearing and weight-bearing activities in older adults. METHODS: High-speed stereo radiography was used to measure the kinematics of the tibiofemoral and patellofemoral joints in subjects as they performed seated, non-weight-bearing knee extension and two weight-bearing activities: lunge and chair rise. PTA and PTMA were extracted from the subject's patellofemoral and tibiofemoral kinematics. Kinematics and the root mean square difference (RMSD) between non-weight-bearing and weight-bearing activities were compared across subjects and activities. RESULTS: Internal rotation increased with weight-bearing (mean RMSD from knee extension was 4.2 ± 2.4° for lunge and 3.6 ± 1.8° for chair rise), and anterior translation was also greater (mean RMSD from knee extension was 2.2 ± 1.2 mm for lunge and 2.3 ± 1.4 mm for chair rise). Patellar tilt and medial-lateral translation changed from non-weight-bearing to weight-bearing. Changes of the patellar tendon from non-weight-bearing to weight-bearing were significant only for PTMA. CONCLUSIONS: While weight-bearing elicited changes in knee kinematics, in most degrees of freedoms, these differences were exceeded by intersubject differences. These results provide comparative kinematics for the evaluation of knee pathology and treatment in older adults.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA