Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Liver Transpl ; 29(4): 422-430, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35976078

RESUMO

Pretransplantation bariatric surgery in patients with high Model for End-Stage Liver Disease (MELD) score is fraught with risks. Bariatric surgery after liver transplantation (LT) may be complicated by surgical adhesions but could have advantages if performed at the time of transplantation. We investigated a method of brief-interval staging combining LT and sleeve gastrectomy (SG). LT recipients with a body mass index (BMI) > 40 kg/m 2 received an SG during the same hospitalization as the LT (LT/SG), at the same time as a planned brief-interval return to the operating room for biliary anastomosis. Differences in intraoperative attributes of the LT (Stage 1) versus SG (Stage 2) procedures were analyzed using Wilcoxon signed-rank test with significance p < 0.05 and compared with patients with obesity having a two-stage LT without SG. A total of 14 cases {median MELD score 33 (interquartile range [IQR], 18-40)} were compared with 28 controls; 60% were critically ill prior to surgery with mechanical ventilation, vasopressors, or continuous renal replacement therapy. Median interval between procedures was 16.1 (IQR, 12.5-22.7) hours for cases and 12.2 (IQR, 11.1-16.6) hours for controls, p  = 0.27. Median BMI at LT/SG was 47.0 (IQR, 41.7-51.3) kg/m 2 versus 38.1 (IQR, 35.7-39.8) kg/m 2 for controls, p < 0.001. At 1 year, median excess body weight loss was 74.0% (IQR, 46.2%-78.7%) in cases and 15.8% (IQR, -5.4% to 62.6%) in controls, p  = 0.13; total weight loss was 38.1% (IQR, 23.9-42.9) in cases versus 7.7% (IQR, -2.4% to 27.6%) for controls, p  = 0.03. Graft survival at 1 year was 92.9% for cases and 89.3% for controls with similar early postoperative outcomes. This proof-of-concept study revealed that a brief-interval SG during LT is feasible in patients with high MELD and resulted in sustained weight loss at 1 year with similar graft survival. Further studies are needed to determine an optimal strategy.


Assuntos
Doença Hepática Terminal , Derivação Gástrica , Transplante de Fígado , Obesidade Mórbida , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Doença Hepática Terminal/cirurgia , Doença Hepática Terminal/complicações , Índice de Gravidade de Doença , Redução de Peso , Gastrectomia/efeitos adversos , Gastrectomia/métodos , Estudos Retrospectivos , Obesidade Mórbida/cirurgia , Obesidade Mórbida/complicações , Resultado do Tratamento
2.
Liver Transpl ; : 422-430, 2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-37160061

RESUMO

ABSTRACT: Pretransplantation bariatric surgery in patients with high Model for End-Stage Liver Disease (MELD) score is fraught with risks. Bariatric surgery after liver transplantation (LT) may be complicated by surgical adhesions but could have advantages if performed at the time of transplantation. We investigated a method of brief-interval staging combining LT and sleeve gastrectomy (SG). LT recipients with a body mass index (BMI) > 40 kg/m 2 received an SG during the same hospitalization as the LT (LT/SG), at the same time as a planned brief-interval return to the operating room for biliary anastomosis. Differences in intraoperative attributes of the LT (Stage 1) versus SG (Stage 2) procedures were analyzed using Wilcoxon signed-rank test with significance p < 0.05 and compared with patients with obesity having a two-stage LT without SG. A total of 14 cases {median MELD score 33 (interquartile range [IQR], 18-40)} were compared with 28 controls; 60% were critically ill prior to surgery with mechanical ventilation, vasopressors, or continuous renal replacement therapy. Median interval between procedures was 16.1 (IQR, 12.5-22.7) hours for cases and 12.2 (IQR, 11.1-16.6) hours for controls, p  = 0.27. Median BMI at LT/SG was 47.0 (IQR, 41.7-51.3) kg/m 2 versus 38.1 (IQR, 35.7-39.8) kg/m 2 for controls, p < 0.001. At 1 year, median excess body weight loss was 74.0% (IQR, 46.2%-78.7%) in cases and 15.8% (IQR, -5.4% to 62.6%) in controls, p  = 0.13; total weight loss was 38.1% (IQR, 23.9-42.9) in cases versus 7.7% (IQR, -2.4% to 27.6%) for controls, p  = 0.03. Graft survival at 1 year was 92.9% for cases and 89.3% for controls with similar early postoperative outcomes. This proof-of-concept study revealed that a brief-interval SG during LT is feasible in patients with high MELD and resulted in sustained weight loss at 1 year with similar graft survival. Further studies are needed to determine an optimal strategy.

3.
Surg Endosc ; 36(9): 6915-6923, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35075523

RESUMO

INTRODUCTION: In cardiac and orthopedic surgery, elevated glycosylated hemoglobin (HbA1c) is a modifiable risk factor for postoperative complications. However, in bariatric surgery, there is insufficient evidence to assess the effectiveness of preoperative HbA1c assessment and its association with postoperative complications. The objective of this study was to assess the impact of HbA1c on early postoperative outcomes in bariatric surgery patients. METHODS: Patients who underwent laparoscopic sleeve gastrectomy and laparoscopic Roux-En-Y Gastric Bypass between 2017 and 2018 were selected for a retrospective review from the metabolic and bariatric surgery accreditation and quality improvement program (MBSAQIP) database. The study population of 118,742 patients was analyzed for our primary outcome which was defined as a composite of any postoperative complications occurring within 30 days. Two groups were defined by HbA1c cutoff: comparison point A (≤ 8% vs > 8%) and comparison point B (≤ 10% vs > 10%). Procedure-related complications were also examined on subgroup analysis. Propensity score matching (PSM) was used with one-to-one matching. The complication rates before and after PSM were calculated and assessed by Fisher's exact test and conditional logistic regression, respectively. RESULTS: After PSM, demographic and clinical characteristics were all balanced and elevated HbA1C was not associated with worse outcomes. After adjusting for underlying comorbidities, there was no statistically significant difference seen in the composite outcome for comparison point A HbA1C ≤ 8 and HbA1C > 8 (p = 0.22). For comparison point B, patients with HbA1C ≤ 10 had more composite complications compared to patients with HbA1C > 10 (p < 0.001). Also, on subgroup analysis after PSM for procedure-specific complications, patients above the cutoff threshold of 8 did not have worsened composite outcomes (p = 0.58 and 0.89 for sleeve and bypass, respectively). Again, at cutoff threshold of 10, patients in HbA1C ≤ 10 had more composite complications (p = 0.001 and 0.007 for sleeve and bypass, respectively). CONCLUSION: In this study of bariatric patients, elevated HbA1c > 8% or 10% was not associated with increased postoperative complications. HbA1c lower than 10% was associated with some types of adverse outcomes in this bariatric dataset. More studies are needed to investigate these findings further. A high HbA1c alone may not disqualify a patient from proceeding with bariatric surgery.


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Cirurgia Bariátrica/efeitos adversos , Gastrectomia/efeitos adversos , Derivação Gástrica/efeitos adversos , Hemoglobinas , Humanos , Laparoscopia/efeitos adversos , Obesidade Mórbida/complicações , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
4.
J Card Fail ; 26(11): 944-947, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32428670

RESUMO

INTRODUCTION: Orthotopic heart transplantation (OHT) is contraindicated in morbidly obese patients with end-stage heart failure (HF), for whom cardiac allograft is the only means for long-term survival. Bariatric surgery may allow them to achieve target body mass index (BMI) for OHT METHODS: From 4/2014 to 12/2018, 26 morbidly obese HF patients who did not meet BMI eligibility criteria for OHT underwent laparoscopic bariatric surgery. Outcomes of interest were median difference in BMI, number of patients achieving target BMI for OHT, and 30-day mortality. RESULTS: Median age was 49 (IQR 14) years, and 13 (50%) were women. HF was mainly systolic (15 patients, 58%). The median LVEF was 27% (IQR 37%). At the time of bariatric surgery, 12 (46%) patients had mechanical circulatory support: 2 (8%) concomitant left ventricular assist device (LVAD) placements, 8 (31%) LVAD already-in-place, and 2 (8%) intra-aortic balloon pumps. There was no 30-day mortality, but one mortality on postoperative day 48. Over a median follow-up of 6 months (range 0-36 months, IQR 17), there was a significant reduction in BMI (p<0.0001). The median postoperative BMI was 36.7 (IQR 8.7), compared to preoperative median BMI of 42.7 (IQR 9.4). Target BMI of < 35 was achieved in 11 (42%) patients. Three patients (12%) have undergone OHT. CONCLUSION: Bariatric surgery in end-stage HF is feasible and results in a high number of patients achieving target BMI, increasing their probability of undergoing OHT. The presence of a LVAD should not preclude these patients from undergoing a bariatric intervention.


Assuntos
Cirurgia Bariátrica , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Obesidade Mórbida , Índice de Massa Corporal , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Humanos , Pessoa de Meia-Idade , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Estudos Retrospectivos
5.
Surg Endosc ; 34(10): 4626-4631, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31676922

RESUMO

INTRODUCTION: Following bariatric surgery, ongoing postoperative testing is required to measure nutritional deficiencies; the purpose of this study was to quantify the prevalence of these nutritional deficiencies based on two-year follow-up tests at recommended time points. METHODS AND PROCEDURES: A retrospective data analysis was conducted of all laboratory tests for bariatric patients who underwent surgery between May 2016 and January 2018 with available lab data (n = 397). Results for nine different nutritional labs were categorized into six recommended postoperative time periods based on time elapsed since the procedure date. Binary variables were created for each laboratory result to calculate descriptive statistics of abnormalities for each lab test over time and used in the individual GEE logistic regression models. Grouped logistic regression examined the total nutritional deficiencies of the nine combined nutrients considering total available labs. RESULTS: Multiple lab tests indicated a very low frequency of abnormalities (e.g., Vitamin A, Vitamin B12, Copper, and Folate). Many of the nine included nutritional labs had an average deficiency of less than 10% across all time points. The grouped logistic model found preoperative nutritional deficiency to be predictive of postoperative nutritional deficiency (OR 3.70, p < 0.001). CONCLUSIONS: We found the vast majority of routine lab test results to be normal at multiple time points. Current practice can add up to significant lab expenses over time. The frequency of postoperative testing in this population may be redundant and of very little value. Unnecessary follow-up laboratory testing costs the patients and the health care system in both time and resources. Patients with preoperative deficiencies appear to be at higher risk for nutritional deficiencies when compared to bariatric surgery patients that did not have preoperative nutritional deficiencies. Future research should focus on defining cost effective postoperative lab testing guidelines for at risk bariatric patients.


Assuntos
Cirurgia Bariátrica/métodos , Técnicas de Laboratório Clínico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Nat Methods ; 12(6): 553-60, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25938370

RESUMO

We must reliably map the interactomes of cellular macromolecular complexes in order to fully explore and understand biological systems. However, there are no methods to accurately predict how to capture a given macromolecular complex with its physiological binding partners. Here, we present a screening method that comprehensively explores the parameters affecting the stability of interactions in affinity-captured complexes, enabling the discovery of physiological binding partners in unparalleled detail. We have implemented this screen on several macromolecular complexes from a variety of organisms, revealing novel profiles for even well-studied proteins. Our approach is robust, economical and automatable, providing inroads to the rigorous, systematic dissection of cellular interactomes.


Assuntos
Substâncias Macromoleculares/metabolismo , Mapeamento de Interação de Proteínas/métodos , Proteínas/química , Linhagem Celular , Escherichia coli , Humanos , Mapas de Interação de Proteínas , Proteínas/metabolismo , Proteômica/métodos , Leveduras
7.
Surg Endosc ; 32(2): 879-888, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28917000

RESUMO

BACKGROUND: Primary laparoscopic hiatal repair with fundoplication is associated with a high recurrence rate. We wanted to evaluate the potential risks posed by routine use of onlay-mesh during hiatal closure, when compared to primary repair. METHODS: Utilizing single-institutional database, we identified patients who underwent primary laparoscopic hiatal repair from January 2005 through December 2014. Retrospective chart review was performed to determine perioperative morbidity and mortality. Long-term results were assessed by sending out a questionnaire. Results were tabulated and patients were divided into 2 groups: fundoplication with hiatal closure + absorbable or non-absorbable mesh and fundoplication with hiatal closure alone. RESULTS: A total of 505 patients underwent primary laparoscopic fundoplication. Mesh reinforcement was used in 270 patients (53.5%). There was no significant difference in the 30-day perioperative outcomes between the 2 groups. No clinically apparent erosions were noted and no mesh required removal. Standard questionnaire was sent to 475 patients; 174 (36.6%) patients responded with a median follow-up of 4.29 years. Once again, no difference was noted between the 2 groups in terms of dysphagia, heartburn, long-term antacid use, or patient satisfaction. Of these, 15 patients (16.9%, 15/89) in the 'Mesh' cohort had symptomatic recurrence as compared to 19 patients (22.4%, 19/85) in the 'No Mesh' cohort (p = 0.362). A reoperation was necessary in 6 patients (6.7%) in the 'Mesh' cohort as compared to 3 patients (3.5%) in the 'No Mesh' cohort (p = 0.543). CONCLUSIONS: Onlay-mesh use in laparoscopic hiatal repair with fundoplication is safe and has similar short and long-term results as primary repair.


Assuntos
Hérnia Hiatal/cirurgia , Telas Cirúrgicas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Fundoplicatura , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Recidiva , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Inquéritos e Questionários , Adulto Jovem
8.
J Virol ; 90(1): 43-56, 2016 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-26446608

RESUMO

UNLABELLED: Human gastrointestinal tract research is limited by the paucity of in vitro intestinal cell models that recapitulate the cellular diversity and complex functions of human physiology and disease pathology. Human intestinal enteroid (HIE) cultures contain multiple intestinal epithelial cell types that comprise the intestinal epithelium (enterocytes and goblet, enteroendocrine, and Paneth cells) and are physiologically active based on responses to agonists. We evaluated these nontransformed, three-dimensional HIE cultures as models for pathogenic infections in the small intestine by examining whether HIEs from different regions of the small intestine from different patients are susceptible to human rotavirus (HRV) infection. Little is known about HRVs, as they generally replicate poorly in transformed cell lines, and host range restriction prevents their replication in many animal models, whereas many animal rotaviruses (ARVs) exhibit a broader host range and replicate in mice. Using HRVs, including the Rotarix RV1 vaccine strain, and ARVs, we evaluated host susceptibility, virus production, and cellular responses of HIEs. HRVs infect at higher rates and grow to higher titers than do ARVs. HRVs infect differentiated enterocytes and enteroendocrine cells, and viroplasms and lipid droplets are induced. Heterogeneity in replication was seen in HIEs from different patients. HRV infection and RV enterotoxin treatment of HIEs caused physiological lumenal expansion detected by time-lapse microscopy, recapitulating one of the hallmarks of rotavirus-induced diarrhea. These results demonstrate that HIEs are a novel pathophysiological model that will allow the study of HRV biology, including host restriction, cell type restriction, and virus-induced fluid secretion. IMPORTANCE: Our research establishes HIEs as nontransformed cell culture models to understand human intestinal physiology and pathophysiology and the epithelial response, including host restriction of gastrointestinal infections such as HRV infection. HRVs remain a major worldwide cause of diarrhea-associated morbidity and mortality in children ≤5 years of age. Current in vitro models of rotavirus infection rely primarily on the use of animal rotaviruses because HRV growth is limited in most transformed cell lines and animal models. We demonstrate that HIEs are novel, cellularly diverse, and physiologically relevant epithelial cell cultures that recapitulate in vivo properties of HRV infection. HIEs will allow the study of HRV biology, including human host-pathogen and live, attenuated vaccine interactions; host and cell type restriction; virus-induced fluid secretion; cell-cell communication within the epithelium; and the epithelial response to infection in cultures from genetically diverse individuals. Finally, drug therapies to prevent/treat diarrheal disease can be tested in these physiologically active cultures.


Assuntos
Intestino Delgado/virologia , Modelos Teóricos , Técnicas de Cultura de Órgãos/métodos , Infecções por Rotavirus/patologia , Infecções por Rotavirus/virologia , Rotavirus/fisiologia , Replicação Viral , Humanos , Intestino Delgado/fisiologia
9.
Surg Endosc ; 30(8): 3638-45, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26514130

RESUMO

BACKGROUND: Optimization of OR management is a complex problem as each OR has different procedures throughout the day inevitably resulting in scheduling delays, variations in time durations and overall suboptimal performance. There exists a need for a system that automatically tracks procedural progress in real time in the OR. This would allow for efficient monitoring of operating room states and target sources of inefficiency and points of improvement. STUDY DESIGN: We placed three wireless sensors (floor-mounted pressure sensor, ventilator-mounted bellows motion sensor and ambient light detector, and a general room motion detector) in two ORs at our institution and tracked cases 24 h a day for over 4 months. RESULTS: We collected data on 238 total cases (107 laparoscopic cases). A total of 176 turnover times were also captured, and we found that the average turnover time between cases was 35 min while the institutional goal was 30 min. Deeper examination showed that 38 % of laparoscopic cases had some aspect of suboptimal activity with the time between extubation and patient exiting the OR being the biggest contributor (16 %). CONCLUSION: Our automated system allows for robust, wireless real-time OR monitoring as well as data collection and retrospective data analyses. We plan to continue expanding our system and to project the data in real time for all OR personnel to see. At the same time, we plan on adding key pieces of technology such as RFID and other radio-frequency systems to track patients and physicians to further increase efficiency and patient safety.


Assuntos
Atenção à Saúde , Salas Cirúrgicas/organização & administração , Melhoria de Qualidade/organização & administração , Atenção à Saúde/organização & administração , Atenção à Saúde/normas , Eficiência Organizacional/normas , Humanos , Laparoscopia/estatística & dados numéricos , Segurança do Paciente , Estudos Retrospectivos , Fatores de Tempo
11.
Surg Innov ; 22(1): 77-82, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24803524

RESUMO

BACKGROUND: Operating rooms have become increasingly complex environments and more prone to errors because of loss of situation awareness. Adding computer intelligence to the operating room may help overcome these limitations particularly if the system can automatically track which step of an operation a surgeon is performing. To develop such a platform, it is necessary to track which laparoscopic instruments are being used and in which port they are inserted. This article describes the development and validation of a "Smart Trocar" that can automatically perform this function. METHODS: A Smart Trocar system prototype was developed that uses a wireless camera attached to a standard laparoscopic port and custom software algorithms. The system recognizes color wheels attached to the handle of a laparoscopic instrument and compares the unique color pattern to an instrument library for proper tool identification. The system was tested for reliability in a box trainer environment using a variety of tool positions and levels of room light illumination. RESULTS: Correct color classification was achieved in 96.7% of trials. There were no errors in detection of the color wheel in space. In addition, the distance of the color wheel from the camera did not influence results and correct classifications were evenly distributed among the 12 laparoscopic tool positions tested. CONCLUSION: This work describes a Smart Trocar system that identifies which laparoscopic tool is being used and in which port and proves its reliability. The system is an important element of a more comprehensive program being developed to automatically understand what step of an operation a surgeon is performing and use these data to improve situation awareness in the operating room.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Laparoscopia/educação , Laparoscopia/instrumentação , Instrumentos Cirúrgicos , Cor , Desenho de Equipamento , Humanos
12.
Yale J Biol Med ; 87(2): 159-66, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24910561

RESUMO

BACKGROUND: A number of bariatric surgical procedures have been developed to manage morbid obesity and related co-morbidities. The non-adjustable gastric band (NAGB) was one such procedure that created restriction to food intake by gastric segmentation. Benefits of the procedure included a low risk of perioperative complications and substantial early weight loss. Unfortunately, the long term results of NAGB include a high incidence of complications and failure to maintain weight loss. The purpose of this study was to examine the presentation, workup, and treatment of patients presenting with complications following NAGB placement. METHODS: A retrospective review of the diagnosis and management of 11 patients who presented with complications related to NAGB placement. RESULTS: All patients presented with some degree of proximal gastric outlet obstruction. The majority of patients (8/11) presented with vomiting as the main complaint. Other complaints included intolerance to solids, liquids, and reflux. Only 2/11 patients presented with weight loss since undergoing NAGB placement, while the remainder had weight regain to their pre-NAGB level and above. Depending on clinical presentation, desire for additional weight loss and co-morbid conditions, patients underwent a variety of treatments. This included NAGB removal (endoscopic, laparo-endoscopic, and laparoscopic) as well as conversion to another bariatric procedure (sleeve gastrectomy, Roux-en-Y gastric bypass). CONCLUSION: Patients with NAGB complications present with symptoms related to a proximal gastric outlet obstruction, related to constriction imposed by the band. This may result in severe food and liquid intolerance and subsequent weight loss, but more likely results in maladaptive eating and subsequent weight gain. Optimal therapy involves removal of the NAGB. Laparoscopic conversion to another bariatric procedure, optimally a Roux-en-Y gastric bypass, is warranted to treat morbid obesity and associated co-morbidities.


Assuntos
Cirurgia Bariátrica/efeitos adversos , Derivação Gástrica/efeitos adversos , Complicações Pós-Operatórias/terapia , Bário , Peso Corporal , Endoscopia do Sistema Digestório , Humanos , Complicações Pós-Operatórias/diagnóstico , Resultado do Tratamento
13.
Surg Obes Relat Dis ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38749781

RESUMO

BACKGROUND: Elevated Hb A1C is a modifiable risk factor for postoperative complications. However, in bariatric surgery, as published by our group and others, elevated preoperative Hb A1C may not be associated with increased postoperative complications. Previous literature has focused on primary bariatric surgery and has excluded the higher-risk revisional surgery cohort. OBJECTIVE: To assess the impact of Hb A1C on early postoperative outcomes in patients requiring revisional bariatric surgery. SETTING: Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program database. METHODS: We undertook a retrospective review of patients undergoing revisional bariatric surgery between 2017 and 2018 from the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program database. Two groups were studied, defined by Hb A1C cutoff, ≤8% versus >8% and ≤10% versus >10%. Early postoperative complications were compared at each threshold, with the primary outcome defined as a composite of all complications. Propensity score matching (PSM) was used with one-to-one matching for covariates, and the complication rates before and after PSM were calculated and assessed by Fisher's exact test and conditional logistic regression, respectively. RESULTS: A total of 16,234 patients had undergone revisional bariatric surgery. After PSM, elevated Hb A1C was not associated with worse outcomes. No significant difference was seen in the composite outcomes for Hb A1C ≤8% versus Hb A1C >8% (P = .22) or for patients with Hb A1C ≤10% versus Hb A1C >10% (P < .46). There were no differences in individual outcomes such as surgical-site infections, cardiopulmonary complications, or readmissions/reinterventions. CONCLUSION: In this study of revisional bariatric patients, elevated Hb A1C >8% or >10% was not associated with increased postoperative complications. Prospective studies are needed to investigate this further.

14.
Biotechniques ; 76(4): 145-152, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38425263

RESUMO

Immunoprecipitation (IP) coupled with mass spectrometry effectively maps protein-protein interactions when genome-wide, affinity-tagged cell collections are used. Such studies have recorded significant portions of the compositions of physiological protein complexes, providing draft 'interactomes'; yet many constituents of protein complexes still remain uncharted. This gap exists partly because high-throughput approaches cannot optimize each IP. A key challenge for IP optimization is stabilizing in vivo interactions during the transfer from cells to test tubes; failure to do so leads to the loss of genuine interactions during the IP and subsequent failure to detect. Our high-content screening method explores the relationship between in vitro chemical conditions and IP outcomes, enabling rapid empirical optimization of conditions for capturing target macromolecular assemblies.


Assuntos
Espectrometria de Massas , Espectrometria de Massas/métodos , Imunoprecipitação
15.
Surg Endosc ; 27(6): 1953-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23355142

RESUMO

BACKGROUND: Minimally invasive components separation (MICS) is believed to decrease wound complications by reducing local tissue damage and eliminating the interruption of blood supply to the overlying skin and soft tissue. One drawback to the MICS technique is the difficulty with identifying the correct location for entry into the anterior abdominal wall. We believe that ultrasound can be used to visually assist identification of the correct surgical entry site (the avascular space between the external and internal abdominal oblique muscles, lateral to the linea semilunaris). PURPOSE: The purpose of this study was to assess if novices can readily learn an ultrasound technique for identifying abdominal wall myofascial components via a video education tool. METHODS: This research was an institutional review board-approved, prospective, observational study. Ten surgical residents were asked to watch a 1-min training video containing basic instructions on ultrasound technique for identifying the myofascial anatomy of the anterior abdominal wall. After watching the educational video, the subjects were asked to identify the linea semilunaris first by external anatomy, then by ultrasound. A grader, blinded to the identification of the subject, recorded if the subject correctly identified the location of the linea semilunaris by each method (external anatomy only versus ultrasound guided). RESULTS: Ten subjects were evaluated. Nine of ten (90 %) subjects correctly identified the linea semilunaris with ultrasound. Only three of ten (30 %) subjects correctly identified the linea semilunaris by physical exam. CONCLUSIONS: Ultrasound technology can aid in identification of the abdominal wall musculofascial units in MICS and be easily taught via short video instruction to novices with excellent results. Further studies will be necessary to prove that ultrasound use can decrease complications associated with entry into the appropriate avascular space between the external and internal abdominal oblique muscles, lateral to the linea semilunaris.


Assuntos
Músculos Abdominais/diagnóstico por imagem , Internato e Residência , Ensino/métodos , Músculos Abdominais/anatomia & histologia , Competência Clínica , Humanos , Estudos Prospectivos , Ultrassonografia de Intervenção , Gravação em Vídeo
16.
Can J Surg ; 54(1): 61-6, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21251434

RESUMO

Laparoscopic adjustable gastric banding (LAGB) is considered to be a safe and effective method of weight loss and reduction of comorbidities associated with obesity. Despite its improved early safety profile compared with Roux-en-Y gastric bypass, patients with LAGB can manifest unique complications that must be recognized and managed appropriately to achieve good outcomes. This review will prepare the general surgeon to identify, diagnose and manage the common complications encountered in patients presenting following LAGB.


Assuntos
Derivação Gástrica/efeitos adversos , Gastroplastia/efeitos adversos , Laparoscopia/efeitos adversos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/cirurgia , Cirurgia Bariátrica/efeitos adversos , Cirurgia Bariátrica/métodos , Índice de Massa Corporal , Remoção de Dispositivo , Feminino , Seguimentos , Derivação Gástrica/métodos , Gastroplastia/instrumentação , Gastroplastia/métodos , Humanos , Laparoscopia/métodos , Masculino , Obesidade Mórbida/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Falha de Prótese , Reoperação , Medição de Risco , Resultado do Tratamento
17.
Obes Surg ; 31(8): 3436-3443, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33945099

RESUMO

PURPOSE: Severe obesity can increase risk of complications after kidney transplantation. There is a paucity of literature on bariatric surgery outcomes in renal transplant candidates. The objective of this study was to analyze outcomes of bariatric surgery as a weight reduction strategy for patients with kidney failure to enhance eligibility for kidney transplantation. MATERIALS AND METHODS: We performed a retrospective analysis of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program database at a single institution for patients with chronic kidney disease receiving hemodialysis therapy (CKD G5D) undergoing bariatric surgery between 2011 and 2018. RESULTS: Of 2363 patients who underwent bariatric surgery, 38 (1.6%) had CKD G5D; median age (range) was 49 years (33; 69), 52.6% were female, and mean BMI was 44.2 kg/m2. Twenty-four patients underwent laparoscopic Roux-en-Y gastric bypass (LRYGB), and 14 patients underwent laparoscopic sleeve gastrectomy. Seventeen patients (46%, n=37) had a BMI≤35 at 6 months, while 25 patients (75.8%, n=33) achieved a BMI≤35 at 12 months. Of these, 18 patients (47%) were listed for kidney transplant, and 8 patients (21%) received kidney transplant. There was no statistically significant difference between sleeve and LRYGB procedures in patients who reached BMI of 35 at 12 months (P=0.58). Median length of stay was 2.3 days. Thirty-day readmission rate was 2 patients (5.3%), and 2 patients (5.3%) required reoperation (one for bleeding, one for acute recurrent hiatal hernia). No mortality occurred. CONCLUSION: Laparoscopic bariatric surgery offers effective weight loss for CKD G5D patients to achieve transplant eligibility with acceptable outcomes.


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Transplante de Rim , Laparoscopia , Obesidade Mórbida , Insuficiência Renal , Feminino , Gastrectomia , Humanos , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias , Diálise Renal , Estudos Retrospectivos , Resultado do Tratamento
18.
Mol Metab ; 44: 101129, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33246140

RESUMO

OBJECTIVE: The mechanisms behind the efficacy of bariatric surgery (BS) for treating obesity and type 2 diabetes, particularly with respect to the influence of the small bowel, remain poorly understood. In vitro and animal models are suboptimal with respect to their ability to replicate the human intestinal epithelium under conditions induced by obesity. Human enteroids have the potential to accelerate the development of less invasive anti-obesity therapeutics if they can recapitulate the pathophysiology of obesity. Our aim was to determine whether adult stem cell-derived enteroids preserve obesity-characteristic patient-specific abnormalities in carbohydrate absorption and metabolism. METHODS: We established 24 enteroid lines representing 19 lean, overweight, or morbidly obese patients, including post-BS cases. Dietary glucose absorption and gluconeogenesis in enteroids were measured. The expression of carbohydrate transporters and gluconeogenic enzymes was assessed and a pharmacological approach was used to dissect the specific contribution of each transporter or enzyme to carbohydrate absorption and metabolism, respectively. RESULTS: Four phenotypes representing the relationship between patients' BMI and intestinal dietary sugar absorption were found, suggesting that human enteroids retain obese patient phenotype heterogeneity. Intestinal glucose absorption and gluconeogenesis were significantly elevated in enteroids from a cohort of obese patients. Elevated glucose absorption was associated with increased expression of SGLT1 and GLUT2, whereas elevated gluconeogenesis was related to increased expression of GLUT5, PEPCK1, and G6Pase. CONCLUSIONS: Obesity phenotypes preserved in human enteroids provide a mechanistic link to aberrant dietary carbohydrate absorption and metabolism. Enteroids can be used as a preclinical platform to understand the pathophysiology of obesity, study the heterogeneity of obesity mechanisms, and identify novel therapeutics.


Assuntos
Gluconeogênese/fisiologia , Glucose/metabolismo , Intestino Delgado/metabolismo , Obesidade Mórbida/metabolismo , Fenótipo , Células-Tronco/metabolismo , Animais , Cirurgia Bariátrica , Diabetes Mellitus Tipo 2/metabolismo , Carboidratos da Dieta/metabolismo , Transportador de Glucose Tipo 2/metabolismo , Transportador de Glucose Tipo 5/metabolismo , Humanos , Absorção Intestinal , Mucosa Intestinal/metabolismo , Transportador 1 de Glucose-Sódio/metabolismo
19.
Surg Endosc ; 24(1): 98-102, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19517187

RESUMO

INTRODUCTION: One of the major complications of applying a prosthetic device to facilitate gastric partitioning has been intraluminal erosion of the prosthesis. Removing an eroded gastric band is fraught with difficulty secondary to the extensive inflammatory response around the proximal stomach and left lobe of the liver. As a result, bariatric clinicians have attempted to apply endoscopic technology to facilitate removal of eroded gastric prostheses. Our study reports on our experience of applying endoscopic scissor transection to remove eroded gastric prostheses in a large tertiary-care medical center. METHODS: A retrospective chart review was conducted to identify all adult (>18 years old) patients managed endoscopically for removal of eroded prosthesis post bariatric surgery at the Baylor College of Medicine Comprehensive Bariatric Surgery Center and the University of Texas-Houston Bariatric Surgery Program. RESULTS: Nine patients, mean body mass index (BMI) 39.5 +/- 7.3 kg/m(2), were managed endoscopically to remove eroded gastric prosthesis post vertical banded gastroplasty. All patients (9/9) reported symptoms consistent with a proximal gastric outlet obstruction (dysphagia, nausea, vomiting). Inadequate weight loss was reported by 67% (6/9) of patients. The mean time for endoscopic band removal was 28.0 +/- 8.8 min. All eroded bands were evident at the end of the gastric pouch and were visualized with either a normal or retroflexed endoscopic view. All nine patients were discharged the same day of their procedure. Mean follow-up of the patients was 9.7 weeks (1-30 weeks). Three patients underwent revisional bariatric surgery following the band removal. CONCLUSION: Our study demonstrates that endoscopic scissor transaction is a safe and effective modality in removing eroded gastric prostheses after vertical banded gastroplasty and avoids the pitfalls associated with removing the eroded bands surgically. It also allows the patient and surgeon to make an insightful decision regarding a revisional bariatric surgical procedure, without being contingent on addressing the eroded gastric band.


Assuntos
Gastroplastia/efeitos adversos , Próteses e Implantes/efeitos adversos , Adulto , Endoscopia , Feminino , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Falha de Prótese , Estudos Retrospectivos
20.
Can J Surg ; 53(2): 126-32, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20334745

RESUMO

Obesity can be considered to be one of the most important chronic diseases facing Canadians of all ages. Whereas patients with a very high body mass index may have the most to gain from procedures such as Roux-en-Y gastric bypass or biliopancreatic diversion/duodenal switch, the increased risk of postoperative complications often makes them poor surgical candidates. As a result, several "bridging" procedures have been proposed to impart clinically effective weight loss and reduce the risk of complications and improve outcomes in the definitive weight-loss procedure. In this article, we provide a review of the evidence in support of laparoscopic sleeve gastrectomy as an innovative new surgical procedure used as a bridging procedure in patients with severe obesity and discuss new findings for its possible role as a definitive procedure for some individuals with less severe obesity. Finally, we comment on a possible approach to introduce this innovative new procedure to Canadian bariatric centres.


Assuntos
Gastrectomia/métodos , Laparoscopia , Obesidade/cirurgia , Gastrectomia/efeitos adversos , Balão Gástrico , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA