Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Med Phys ; 51(6): 4181-4200, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38478305

RESUMO

BACKGROUND: On enhancing the image quality of low-dose computed tomography (LDCT), various denoising methods have achieved meaningful improvements. However, they commonly produce over-smoothed results; the denoised images tend to be more blurred than the normal-dose targets (NDCTs). Furthermore, many recent denoising methods employ deep learning(DL)-based models, which require a vast amount of CT images (or image pairs). PURPOSE: Our goal is to address the problem of over-smoothed results and design an algorithm that works regardless of the need for a large amount of training dataset to achieve plausible denoising results. Over-smoothed images negatively affect the diagnosis and treatment since radiologists had developed clinical experiences with NDCT. Besides, a large-scale training dataset is often not available in clinical situations. To overcome these limitations, we propose locally-adaptive noise-level matching (LANCH), emphasizing the output should retain the same noise-level and characteristics to that of the NDCT without additional training. METHODS: We represent the NDCT image as the pixel-wisely weighted sum of an over-smoothed output from off-the-shelf denoiser (OSD) and the difference between the LDCT image and the OSD output. Herein, LANCH determines a 2D ratio map (i.e., pixel-wise weight matrix) by locally matching the noise-level of output and NDCT, where the LDCT-to-NDCT device flux (mAs) ratio reveals the NDCT noise-level. Thereby, LANCH can preserve important details in LDCT, and enhance the sharpness of the noise-free regions. Note that LANCH can enhance any LDCT denoisers without additional training data (i.e., zero-shot). RESULTS: The proposed method is applicable to any OSD denoisers, reporting significant texture plausibility development over the baseline denoisers in quantitative and qualitative manners. It is surprising that the denoising accuracy achieved by our method with zero-shot denoiser was comparable or superior to that of the best training-based denoisers; our result showed 1% and 33% gains in terms of SSIM and DISTS, respectively. Reader study with experienced radiologists shows significant image quality improvements, a gain of + 1.18 on a five-point mean opinion score scale. CONCLUSIONS: In this paper, we propose a technique to enhance any low-dose CT denoiser by leveraging the fundamental physical relationship between the x-ray flux and noise variance. Our method is capable of operating in a zero-shot condition, which means that only a single low-dose CT image is required for the enhancement process. We demonstrate that our approach is comparable or even superior to supervised DL-based denoisers that are trained using numerous CT images. Extensive experiments illustrate that our method consistently improves the performance of all tested LDCT denoisers.


Assuntos
Processamento de Imagem Assistida por Computador , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Humanos , Algoritmos , Aprendizado Profundo
2.
Chonnam Med J ; 60(1): 69-77, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38304127

RESUMO

This study was conducted to investigate potential differences in vaccine efficacy between patients undergoing palliative chemotherapy and receiving adjuvant chemotherapy. Additionally, the study proved the influence of vaccination timing on vaccine efficacy during active chemotherapy. Anti-receptor-binding domain (RBD) IgG binding antibody assays and surrogate neutralizing antibody assays were performed after BNT162b2 or mRNA-1273 vaccination in 45 solid cancer patients (23 adjuvant and 22 palliative chemotherapy) and in 24 healthy controls before vaccination (baseline), at every two to four weeks after the first (post-dose 1) and the second vaccination (post-dose 2). The levels of anti-RBD IgG and neutralizing antibodies increased significantly from baseline through post-dose 1 to post-dose 2 in all three groups. At the post-dose 1, the anti-RBD IgG and neutralizing antibody levels were significantly lower in cancer patients than in healthy controls. However, by post-dose 2, the seropositivity of anti-RBD IgG and neutralizing antibodies uniformly reached 100% across all groups, with no significant disparity in antibody levels among the three groups. Moreover, the antibody titers were not significantly different between patients with a vaccine and chemotherapy interval of more than 14 days or those with less than 14 days. This study demonstrated that after second doses of mRNA COVID-19 vaccines, humoral immune responses in patients receiving chemotherapy were comparable to those of healthy controls, regardless of whether the purpose of the anti-cancer treatment was palliative or adjuvant. Furthermore, the timing of vaccination did not affect the level of humoral immunity after the second vaccination.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA