Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Am J Physiol Regul Integr Comp Physiol ; 320(6): R972-R983, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33949210

RESUMO

Peripheral artery disease (PAD) in the lower limb compromises oxygen supply due to arterial occlusion. Ischemic skeletal muscle is accompanied by capillary structural deformation. Therefore, using novel microscopy techniques, we tested the hypothesis that endothelial cell swelling temporally and quantitatively corresponds to enhanced microvascular permeability. Hindlimb ischemia was created in male Wistar rat's by iliac artery ligation (AL). The tibialis anterior (TA) muscle microcirculation was imaged using intravenously infused rhodamine B isothiocyanate dextran fluorescent dye via two-photon laser scanning microscopy (TPLSM) and dye extravasation at 3 and 7 days post-AL quantified to assess microvascular permeability. The TA microvascular endothelial ultrastructure was analyzed by transmission electron microscopy (TEM). Compared with control (0.40 ± 0.15 µm3 × 106), using TPLSM, the volumetrically determined interstitial leakage of fluorescent dye measured at 3 (3.0 ± 0.40 µm3 × 106) and 7 (2.5 ± 0.8 µm3 × 106) days was increased (both P < 0.05). Capillary wall thickness was also elevated at 3 (0.21 ± 0.06 µm) and 7 (0.21 ± 0.08 µm) days versus control (0.11 ± 0.03 µm, both P < 0.05). Capillary endothelial cell swelling was temporally and quantitatively associated with elevated vascular permeability in the AL model of PAD but these changes occurred in the absence of elevations in protein levels of vascular endothelial growth factor (VEGF) its receptor (VEGFR2 which decreased by AL-7 day) or matrix metalloproteinase. The temporal coherence of endothelial cell swelling and increased vascular permeability supports a common upstream mediator. TPLSM, in combination with TEM, provides a sensitive and spatially discrete technique to assess the mechanistic bases for, and efficacy of, therapeutic countermeasures to the pernicious sequelae of compromised peripheral arterial function.


Assuntos
Permeabilidade Capilar/fisiologia , Isquemia/fisiopatologia , Microscopia Confocal , Músculo Esquelético/irrigação sanguínea , Animais , Membro Posterior/fisiopatologia , Ligadura/métodos , Microcirculação/fisiologia , Microscopia Confocal/métodos , Microvasos/fisiopatologia , Neovascularização Fisiológica/fisiologia , Ratos Wistar
2.
J Appl Physiol (1985) ; 125(2): 369-380, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29722621

RESUMO

Via modulation of endothelial integrity and vascular permeability in response to damage, skeletal muscle microvessels play a crucial permissive role in tissue leukocyte invasion. However, direct visual evidence of altered microvascular permeability of skeletal muscle has not been technically feasible, impairing mechanistic understanding of these responses. Two-photon laser scanning microscopy (TPLSM) allows three-dimensional in vivo imaging of skeletal muscle microcirculation. We hypothesized that the regulation of microvascular permeability in vivo is temporally related to acute inflammatory and regenerative processes following muscle injury. To test our hypothesis, tibialis anterior muscles of anesthetized male Wistar rats were subjected to eccentric contractions (ECCs) via electrical stimulation. The skeletal muscle microcirculation was imaged by an intravenously infused fluorescent dye (rhodamine B isothiocyanate-dextran) to assess microvascular permeability via TPLSM 1, 3, and 7 days after ECC. Immunohistochemistry on serial muscle sections was performed to determine the proportion of VEGF-A-positive muscle fibers in the damaged muscle. Compared with control rats, the volumetrically determined interstitial leakage of fluorescent dye (5.1 ± 1.4, 5.3 ± 1.2 vs. 0.51 ± 0.14 µm3 × 106; P < 0.05, days 1 and 3, respectively, vs. control) and percentage of VEGF-A-positive fibers in the damaged muscle (10 ± 0.4%, 22 ± 1.1% vs. 0%; days 1 and 3, respectively, vs. control) were significantly higher on days 1 and 3 after ECC. The interstitial leakage volume returned to control by day 7. These results suggest that microvascular hyperpermeability assessed by in vivo TPLSM imaging is associated with ECC-induced muscle damage and increased VEGF expression. NEW & NOTEWORTHY This investigation employed a novel in vivo imaging technique for skeletal muscle microcirculation using two-photon laser scanning microscopy that enabled microvascular permeability to be assessed by four-dimensional image analysis. By combining in vivo imaging and histological analysis, we found the temporal profile of microvascular hyperpermeability to be related to that of eccentric contraction-induced skeletal muscle injury and pronounced novel myocyte VEGF expression.


Assuntos
Permeabilidade Capilar/fisiologia , Contração Muscular/fisiologia , Fibras Musculares Esqueléticas/fisiologia , Ferimentos e Lesões/fisiopatologia , Animais , Estimulação Elétrica/métodos , Masculino , Microcirculação/fisiologia , Microscopia Confocal/métodos , Ratos , Ratos Wistar
3.
Sci Rep ; 7(1): 6921, 2017 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-28761143

RESUMO

Recent studies have demonstrated the advantage of developing pressure-sensitive devices with light-emitting properties for direct visualization of pressure distribution, potential application to next generation touch panels and human-machine interfaces. To ensure that this technology is available to everyone, its production cost should be kept as low as possible. Here, simple device concepts, namely, pressure sensitive flexible hybrid electrodes and OLED architecture, are used to produce low-cost resistive or light-emitting pressure sensors. Additionally, integrating solution-processed self-assembled micro-structures into the flexible hybrid electrodes composed of an elastomer and conductive materials results in enhanced device performances either in terms of pressure or spatial distribution sensitivity. For instance, based on the pressure applied, the measured values for the resistances of pressure sensors range from a few MΩ down to 500 Ω. On the other hand, unlike their evaporated equivalents, the combination of solution-processed flexible electrodes with an inverted OLED architectures display bright green emission when a pressure over 200 kPa is applied. At a bias of 3 V, their luminance can be tuned by applying a higher pressure of 500 kPa. Consequently, features such as fingernails and fingertips can be clearly distinguished from one another in these long-lasting low-cost devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA