Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 33(1): 40-45, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34676946

RESUMO

BACKGROUND: Cavo-tricuspid isthmus (CTI) linear ablation is performed not only for atrial flutter (AFL) but empirically during atrial fibrillation (AF) ablation in real-world practice.  PURPOSE: We sought to evaluate the safety and durability of the CTI ablation.  METHODS: This retrospective study included 1078 consecutive patients who underwent a CTI ablation. AFL was documented before or during the procedure in 249 (23.1%) patients, and an empirical CTI and AF ablation were performed in 829 (76.9%) patients.  RESULTS: CTI block was successfully created in 1051 (97.5%) patients with a 10.3 ± 6.6 min total radiofrequency time. Repeat procedures were performed for recurrent arrhythmias in 187 (17.3%) patients at a median of 11.0 (5.0-30.0) months postprocedure, and conduction resumption was identified in 68/174 (39.1%). Among those undergoing a CTI ablation with an AF ablation, the durability was significantly higher in those with than without documented AFL (78.1% vs. 58.2%, p = .031).  The total radiofrequency time was significantly shorter (9.0 ± 5.3 vs. 10.0 ± 6.4 [mins], p = .024) and durability significantly higher (78.1 vs. 58.7[%], p = .043) in the large-tip than irrigated-tip catheter group. Iatrogenic AFL was observed after the empiric CTI ablation in 11 (1.3%) patients. Procedure-related complications occurred in 15 (1.4%) patients. Eight patients experienced coronary artery spasms, including one with ventricular fibrillation following ST elevation on the ward. The other six patients experienced transient atrioventricular block and one experienced cardiac tamponade requiring drainage.  CONCLUSIONS: Despite a high acute CTI ablation success, the conduction block durability was relatively low after the empiric ablation. An empiric CTI ablation at the time of the AF ablation is not recommended.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
2.
BMC Cardiovasc Disord ; 22(1): 57, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35172730

RESUMO

BACKGROUND: Left atrial roof-dependent tachycardias (LARTs) are common macroreentrant atrial tachycardias (ATs). We sought to characterize clinical LARTs using an ultra-high resolution mapping system. METHODS: This study included 22 consecutive LARTs in 21 patients who underwent AT mapping/ablation using Rhythmia systems. RESULTS: Three, 13, 4, and 2 LART patients were cardiac intervention naïve (Group-A), post-roof line ablation (Group-B), post-atrial fibrillation ablation without linear ablation (Group-C), and post-cardiac surgery (Group-D), respectively. The mean AT cycle length was 244 ± 43 ms. Coronary sinus activation was proximal-to-distal or distal-to-proximal in 16 (72.7%) ATs. The activation map revealed 13 (59.1%) clockwise and 9 (40.9%) counter-clockwise LARTs. A 12-lead synchronous isoelectric interval was observed in 10/19 (52.6%) LARTs. The slow conduction area was identified on the LA roof, anterior/septal wall, and posterior wall in 18, 6, and 2 ATs, respectively. Twenty concomitant ATs among 13 procedures were also eliminated, and peri-mitral AT coexisted in 7 of 9 non-group-B patients. In group-B, the conduction gap was predominantly located on the mid-roof. Sustained LARTs were terminated by a single application and linear ablation in 6 (27.3%) and 9 (40.9%), while converting to other ATs in 7 (31.8%) LARTs. Complete linear block was created without any complications in all, however, ablation at the mid-posterior wall was required to achieve block in 4 (18.2%) procedures. During 14.0 (6.5-28.5) months of follow-up, 17 (81.0%) and 19 (90.5%) patients were free from any atrial tachyarrhythmias after single and last procedures. CONCLUSIONS: The LART mechanisms were distinct in individual patients, and elimination of all concomitant ATs was required for the management.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/cirurgia , Taquicardia Supraventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
3.
Heart Vessels ; 37(12): 2049-2058, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35790552

RESUMO

BACKGROUND: Few studies have examined whether catheter ablation for AF patients improves biomarkers other than serum levels of brain natriuretic peptide (BNP) and renal function. This study was to explore whether catheter ablation for atrial fibrillation (AF) patients affects uric acid (UA), glucose and lipid metabolism. METHODS AND RESULTS: A total of 206 patients (66.6 ± 10.4 years; 132 men) who underwent initial AF ablation without changes to oral medications were included. Baseline BNP and UA levels significantly decreased at 1 year after ablation (p < 0.05 each). Changes in UA level correlated significantly with pre-procedural UA level (r = 0.57). In multivariable logistic regression modeling, pre-procedural UA level, persistent AF, and hemoglobin A1c (p < 0.05 each) were independent predictors of post-procedural UA level decline. Significant improvements in both persistent and paroxysmal AF patients were identified, and the magnitude of post-procedural serum UA level decline after ablation (ΔUA) was significantly greater in patients with persistent AF (0.8 ± 1.0 mg/dl) than in those with paroxysmal AF (0.2 ± 0.8 mg/dl, p < 0.001). Of the 48 patients with high UA level before procedure, 28 patients showed improvement in UA level to normal range. CONCLUSIONS: Catheter ablation for AF patients significantly improved serum UA levels without obvious influences of heart failure, renal function, or inflammation, suggesting that AF ablation may be effective for AF patients with hyperuricemia. Trial registration The study was approved by the Research Ethics Committee of University of Fukui (no. 20210132) and clinical trial registration (UMIN000044669).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ácido Úrico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Biomarcadores/sangue , Glucose/metabolismo , Lipídeos/sangue , Resultado do Tratamento , Ácido Úrico/sangue
4.
Int Heart J ; 63(1): 49-55, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35095076

RESUMO

The diagnosis of cardiac amyloidosis is frequently delayed because histological confirmation is often challenging. Few studies have attempted to clarify the utility and safety of abdominal fat pad fine-needle aspiration (FPFNA) for an initial screening test in patients with suspected cardiac amyloidosis.This study included 77 consecutive patients with suspected non-ischemic cardiomyopathy who had left ventricular dysfunction and/or hypertrophy. All patients underwent abdominal FPFNA and an endomyocardial biopsy. In all patients, the abdominal FPFNA could be performed within less than 5 minutes with no complications; however, in 1 patient (1.3%), the obtained specimen was too small to evaluate. Among the remaining 76 patients, 5 (6.6%) were positive for amyloid (FPFNA[+]) and 7 (9.2%), including the 5 FPFNA[+], were diagnosed with cardiac amyloidosis (AL = 1, ATTR = 6) by endomyocardial biopsy. Positive abdominal FPFNAs indicated cardiac amyloidosis with high accuracy (sensitivity, 71.4%; specificity, 100%).Positive abdominal FPFNAs are directly linked to diagnoses of cardiac amyloidosis. Abdominal FPFNA is simple and useful for the initial screening test for cardiac amyloidosis in patients with non-ischemic cardiomyopathy.


Assuntos
Gordura Abdominal/patologia , Amiloidose/diagnóstico , Biópsia por Agulha Fina , Cardiopatias/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Endocárdio/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico
5.
J Cardiovasc Electrophysiol ; 32(5): 1305-1319, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33682247

RESUMO

BACKGROUND: Low voltage areas (LVAs) are most commonly observed on the left atrial (LA) septal/anterior wall. OBJECTIVE: We explored the mechanisms of LA septal/anterior wall reentrant tachycardias (LASARTs) using ultrahigh resolution mapping. METHODS: This study included seven consecutive LASARTs in six patients (75 [62.2-82.8] years, 4 women) who underwent atrial tachycardia (AT) mapping and ablation using Rhythmia systems. RESULTS: The AT cycle length was 266 (239-321) ms. During ATs, 11.0 (9.0-12.9) cm2 of LVAs were identified in all, and 0.8 (0.7-1.7) cm2 of dense scar was identified in four patients. Five ATs rotated around dense scar, while two rotated around functional linear block, which was confirmed during atrial pacing after AT termination. The AT circuit length was 8.7 ± 2.1 cm with a conduction velocity of 30.4 ± 3.7 cm/s. A median of 3.0 (2.0-4.0) slow conduction areas per circuit were identified, and 17/23 (73.9%) areas were present in LVAs, while they were at the border of the LVA and normal voltage areas in the remaining 6/23 (26.1%). Global activation histograms facilitated the identification of the critical isthmus in all. Tailor-made ablation at critical isthmuses successfully eliminated all ATs. However, one patient with AT related to functional linear block experienced recurrent AT related to dense scar, which progressed after the procedure. During a mean 14 ± 13 month follow-up after the last procedure, no patients experienced recurrent ATs without any complications. CONCLUSION: LASARTs consist of not only fixed conduction blocks but also functional conduction blocks. Ultrahigh resolution mapping is highly useful to decide the optimal tailor-made ablation strategy based on the mechanisms.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Feminino , Átrios do Coração/cirurgia , Frequência Cardíaca , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
6.
BMC Cardiovasc Disord ; 21(1): 490, 2021 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-34629051

RESUMO

BACKGROUND: Several studies have recently addressed the importance of glycemic variability (GV) in patients with acute coronary syndrome (ACS). Although daily GV measures, such as mean amplitude of glycemic excursions, are established predictors of poor prognosis in patients with ACS, the clinical significance of day-to-day GV remains to be fully elucidated. We therefore monitored day-to-day GV in patients with ACS to examine its significance. METHODS: In 25 patients with ACS, glucose levels were monitored for 14 days using a flash continuous glucose monitoring system. Mean of daily differences (MODD) was calculated as a marker of day-to-day GV. N-terminal pro-brain natriuretic peptide (NT-proBNP) was evaluated within 4 days after hospitalization. Cardiac function (left ventricular end-diastolic volume, left ventricular ejection fraction, stroke volume) was assessed by echocardiography at 3-5 days after admission and at 10-12 months after the disease onset. RESULTS: Of the 25 patients, 8 (32%) were diagnosed with diabetes, and continuous glucose monitoring (CGM)-based MODD was high (16.6 to 42.3) in 17 patients (68%). Although MODD did not correlate with max creatine kinase (CK), there was a positive correlation between J-index, high blood glucose index, and NT-proBNP (r = 0.83, p < 0.001; r = 0.85, p < 0.001; r = 0.41, p = 0.042, respectively). CONCLUSIONS: In patients with ACS, MODD was associated with elevated NT-proBNP. Future studies should investigate whether day-to-day GV in ACS patients can predict adverse clinical events such as heart failure.


Assuntos
Síndrome Coronariana Aguda/sangue , Automonitorização da Glicemia , Glicemia/metabolismo , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Automonitorização da Glicemia/instrumentação , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Admissão do Paciente , Fragmentos de Peptídeos/sangue , Valor Preditivo dos Testes , Prognóstico , Volume Sistólico , Fatores de Tempo , Função Ventricular Esquerda
7.
Heart Vessels ; 36(7): 1027-1034, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33507357

RESUMO

Reported mapping procedures of left atrial (LA) low-voltage areas (LVAs) vary widely. This study aimed to compare the PentaRay®/CARTO®3 (PentaRay map) and Orion™/Rhythmia™ (Orion map) systems for LA voltage mapping. This study included 15 patients who underwent successful pulmonary vein isolation (PVI) for atrial fibrillation. After PVI, PentaRay and Orion maps created for all patients were compared. LVAs were defined as sites with ≥ 3 adjacent low-voltage points < 0.5 mV. LVAs were indicated in 8 (53%) among 15 patients, and the average values of the measured LVAs was comparable between the systems (PentaRay map = 5.4 ± 8.7 cm2; Orion map = 4.3 ± 6.4 cm2, p = 0.69). However, in 2 of 8 patients with LVAs, the Orion map indicated LVAs at the septum and posterolateral sites of the LA, respectively, whereas the PentaRay map indicated no LVAs. In those patients, sharp electrograms of > 0.5 mV were properly recorded at the septum and posterolateral sites during appropriate beats in the PentaRay map. The PentaRay map had a shorter procedure time than the Orion map (12 ± 3 min vs. 23 ± 8 min, respectively; p < 0.01). Our study results showed a discrepancy in the LVA evaluation between the PentaRay and Orion maps. In 2 of 15 patients, the Orion map indicated LVAs at the sites where > 0.5-mV electrograms were properly recorded in the PentaRay map.


Assuntos
Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo/fisiologia , Mapeamento Potencial de Superfície Corporal/métodos , Átrios do Coração/fisiopatologia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia
8.
Heart Vessels ; 36(10): 1542-1550, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33811554

RESUMO

Few studies have examined the efficacy and safety of cardiac rehabilitation in patients with atrial fibrillation (AF) who underwent AF ablation. We explored the feasibility of additional cardiac rehabilitation after AF ablation in patients with a reduced left ventricular ejection fraction (LVEF). Fifty-four patients with heart failure (HF) and a reduced LVEF (HFrEF) (LVEF < 50%; 67.1 ± 11.6 years; 43 men) who underwent initial AF ablation procedures were included. Fourteen (25.9%) patients underwent cardiac rehabilitation (rehabilitation-group) and the remaining 40 (74.1%) did not (non-rehabilitation-group) after the procedure. The rehabilitation-group patients were relatively older, more likely female (p = 0.024), and had more likely a history of an HF hospitalization (p < 0.01) and cardiac device implantation (p = 0.041). The baseline LVEF was significantly lower (p = 0.043) and brain natriuretic peptide (BNP) (p < 0.01) and C-reactive protein (CRP) (p < 0.01) values were significantly higher in the rehabilitation-group. The 6-min walk distance significantly improved after 21.4 ± 11.5 days of cardiac rehabilitation during hospitalization (226.1 ± 155.9 vs. 398.1 ± 77.5 m, p = 0.016) without any adverse events. During an 18.9 ± 6.3 month follow-up period, the freedom from AF recurrence (p = 0.52) and re-hospitalizations due to HF (p = 0.63) were similar between the 2 groups. No death or strokes were observed. During the follow-up period, the LVEF significantly improved similarly in both groups, and the change in the BNP and CRP values significantly decreased in the rehabilitation-group. Despite the rehabilitation-group patients having a more severe HF status, the clinical outcomes and AF freedom were similar between the 2 groups, suggesting the favorable impact of cardiac rehabilitation after AF ablation in HFrEF patients.


Assuntos
Fibrilação Atrial , Reabilitação Cardíaca , Ablação por Cateter , Disfunção Ventricular Esquerda , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda
9.
J Cardiovasc Electrophysiol ; 31(10): 2653-2664, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32639637

RESUMO

INTRODUCTION: Despite the characteristic electrocardiogram (ECG) findings of early activation during ventricular tachyarrhythmias (VAs) and/or excellent pacemapping in the right ventricular outflow tract (RVOT), some VAs may require additional, left-sided ablation for a cure. METHODS AND RESULTS: This study included five patients with idiopathic VAs whose QRS morphologies were highly suggestive of an RVOT origin. The ECG characteristics and intracardiac electrocardiograms during catheter ablation were assessed. In all patients, the clinical VAs had an LBBB QRS morphology and inferior axis with a precordial R/S transition through leads V3-V5, and negative components in lead I. The earliest activation during the VAs (local electrogram-QRS interval = -34 ± 6.8 ms) and excellent pacemapping were obtained at the posterior portion of the RVOT just beneath the pulmonary valve. However, ablation at those sites failed, and the QRS morphology of the VAs changed. During left-sided OT mapping, the earliest activation was found at sites just contralateral to the initially ablated sites of the RVOT (junction of the left and right coronary cusps = 2, left coronary cusp = 3). In spite of the late activation time and poor pacemapping scores, catheter ablation at those sites cured the VAs. Those successful sites were also near the transitional zone from the great cardiac vein to the anterior interventricular vein (GCV-AIV). CONCLUSIONS: Some VAs, highly suggestive of having RVOT origins, require catheter ablation in the left-sided OT near the initially ablated RVOT site. Those VAs have the same ECG characteristics and might have intramural origins in the superobasal LV surrounded by the RVOT, LVOT, and GCV-AIV.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
10.
J Cardiovasc Electrophysiol ; 31(6): 1385-1393, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32249492

RESUMO

BACKGROUND: Few studies have examined the characteristics of catheter ablation vascular complications, and recently physicians increasingly use computed tomography angiography (CTA) for diagnosing. OBJECTIVE: We sought to investigate the incidence of femoral vascular complications in catheter ablation and factors associated with complications in the current era. METHODS: This single-center observational study consisted of 311 consecutive (atrial fibrillation, atrial flutter, paroxysmal supraventricular tachycardia, and ventricular arrhythmias in 222 [71.4%], 7 [2.3%], 43 [13.8%], and 39 [12.5%]) patients who underwent catheter ablation. The detailed patient data and clinical outcomes were obtained from the medical records. RESULTS: Emergent CTA was performed in a total of 8 (2.6%) patients at a median of 4.5 (2.0-12.5) days postprocedure, and the precise diagnosis was obtained in all. Among them, pseudoaneurysms, arteriovenous fistulae (AVF), and actively bleeding hematomas were identified in two, one, and one patient, respectively, and all required readmissions after discharge. AVF was diagnosed by a Doppler ultrasound examination in another patient. In total, 5 (1.6%) patients exhibited major femoral vascular complications including two pseudoaneurysms, two AVFs, and one active bleeding hematoma. The pseudoaneurysms and AVFs were successfully eliminated by direct compression, and extravasation from the femoral circumflex artery required coil embolization. Antiplatelet therapy and the use of larger arterial sheaths (≥7-Fr) increased the major femoral arterial complications, but atrial fibrillation ablation under uninterrupted anticoagulation therapy or the use of larger venous sheaths did not. CONCLUSION: Vascular complications are still not negligible procedure-related complications during catheter ablation in the current era. CTA provides a rapid and precise diagnosis for optimal treatment strategies.


Assuntos
Ablação por Cateter/efeitos adversos , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada , Artéria Femoral/diagnóstico por imagem , Lesões do Sistema Vascular/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral/lesões , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/epidemiologia , Lesões do Sistema Vascular/terapia
11.
J Cardiovasc Electrophysiol ; 31(5): 1075-1082, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32108407

RESUMO

BACKGROUND: Atrial linear lesions are generally created with radiofrequency energy. We sought to evaluate the feasibility of cryothermal atrial linear ablation. METHODS AND RESULTS: Twenty-one atrial fibrillation (AF) patients underwent linear ablation on the left atrial (LA) roof, mitral isthmus (MI), and cavotricuspid isthmus (CTI) with 8-mm-tip cryocatheters following pulmonary vein isolation. The data were compared with those of 31 patients undergoing linear ablation with irrigated-tip radiofrequency catheters. Conduction block was successfully created in 18 of 20 (90%), 9 of 21 (43%), and 20 of 20 (100%) on the LA roof, MI, and CTI by endocardial cryoablation alone with 19.0 (12.0-24.0), 30.0 (23.0-34.0), and 14.0 (14.0-16.0) minute cryo applications, respectively. The presence of either an interposed circumflex artery or pouch at the MI was significantly associated with failed MI block (P = .04). Conduction block was created in 25 of 31 (83.9%), 27 of 31 (87.1%), and 30 of 31 (96.8%) on the roof, MI, and CTI, respectively, by radiofrequency ablation. During the 17.5 (13.0-31.7) months of follow-up, freedom from AF/atrial tachycardia (AT) was significantly higher in the cryo group (P = .05); especially, recurrent AT was more frequent in the RF group (8/31 vs 1/21; P = .03). Conduction block across the roof, MI, and CTI was durable in 6 of 12 (50.0%), 4 of 12 (33.3%), and 9 of 12 (75.0%) patients during second procedures. All nine patients (except one) with recurrent ATs had at least one roof or MI conduction resumption. CONCLUSIONS: Cryoablation is effective for creating a roof and CTI linear block, however, creating MI block by endocardial ablation alone was often challenging. Conduction resumption of LA linear block is common and recurrent arrhythmias, especially iatrogenic ATs, are more frequently observed after radiofrequency linear ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo
12.
Heart Vessels ; 35(2): 246-251, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31440830

RESUMO

Atrial tachyarrhythmias often originate from the superior vena cava (SVC), and right superior (RSPV) and inferior pulmonary veins (RIPV). However, a precise differentiation of those origins is challenging using the standard 12-lead electrocardiogram (ECG) P-wave morphology due to the anatomical proximity. The recently developed synthesized 18-lead ECG provides virtual waveforms of the right-sided chest and back leads. This study evaluated the utility of the synthesized 18-lead ECG to differentiate atrial arrhythmias originating from 3 adjacent structures. Synthesized 18-lead ECGs were obtained during SVC-, RSPV-, and RIPV-pacing in 20 patients with lone paroxysmal atrial fibrillation to develop an algorithm. The P-wave morphologies were classified into 4 patterns: positive, negative, biphasic, and isoelectric. Subsequently, the algorithm's accuracy was validated prospectively in another 40 patients. In retrospective analyses, isoelectric P-waves in synthesized V7 distinguished RIPV-pacing from the others (sensitivity = 81%, specificity = 92%) (first criteria). The P wave morphologies in Leads II (sensitivity = 83%, specificity = 94%) and V1 (sensitivity = 84%, specificity = 80%) distinguished SVC- and RSPV-pacing (second criteria). In a prospective evaluation, the sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV], and accuracy of the first criteria for identifying RIPV-pacing was 97%, 90%, 78%, 99%, and 92%, respectively. The sensitivity, specificity, RPV, NPV, and accuracy of the second criteria (amplitudes > 1 mV in lead II or biphasic P-waves in lead V1) for discriminating SVC- and RSPV-pacing was 66%, 95%, 98%, 50%, and 74%, respectively. The P wave morphology pattern in lead V7 in synthesized 18-lead ECGs is useful for differentiating RIPV origins from RSPV/SVC origins.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Frequência Cardíaca , Veias Pulmonares/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Veia Cava Superior/fisiopatologia , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Diagnóstico Diferencial , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo
13.
J Cardiovasc Electrophysiol ; 30(10): 1841-1847, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31328311

RESUMO

BACKGROUND: The utility of pressure waveform analyses to assess pulmonary vein (PV) occlusions has been reported in cryoballoon PV isolation (CB-PVI) using first-generation CBs. This prospective randomized study compared the procedural and clinical outcomes of pressure-guided and conventional CB-PVI. METHODS AND RESULTS: Sixty patients with paroxysmal atrial fibrillation underwent CB-PVI with 28-mm second-generation CBs. PV occlusions were assessed either by real-time pressure waveforms without contrast utilization (pressure-guided group) or contrast injections (conventional group) and randomly assigned. Before the randomization, 24 patients underwent pressure-guided CB-PVIs. In the derivation study, a vein occlusion was obtained in 88/96 (91.7%) PVs among which 86 (97.7%) were successfully isolated by the application. In the validation study, the nadir balloon temperature and total freezing time did not significantly differ per PV between the two groups. The positive predictive value of the vein occlusion for predicting successful acute isolations was similar (93 of 103 [90.2%] and 89 of 98 [90.8%] PVs; P = 1.000), but the negative predictive value was significantly higher in pressure-guided than angiographical occlusions (14 of 17 [82.3%] vs 7 of 22 [31.8%]; P = .003). Both the procedure (57.7 ± 14.2 vs 62.6 ± 15.8 minutes; P = .526) and fluoroscopic times (16.3 ± 6.4 vs 20.1 ± 6.1; P = .732) were similar between the two groups, however, the fluoroscopy dose (130.6 ± 97.7 vs 353.2 ± 231.4 mGy; P < .001) and contrast volume used (0 vs 17.5 ± 7.7 mL; P < .001) were significantly smaller in the pressure-guided than conventional group. During 27.8 (5-39) months of follow-up, the single procedure arrhythmia freedom was similar between the two groups (P = .438). CONCLUSIONS: Pressure-guided second-generation CB-PVIs were similarly effective and as safe as conventional CB-PVIs. This technique required no contrast utilization and significantly reduced radiation exposure more than conventional CB-PVIs.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Criocirurgia , Veias Pulmonares/cirurgia , Pressão Venosa , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Meios de Contraste/administração & dosagem , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Feminino , Frequência Cardíaca , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Flebografia , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Radiografia Intervencionista , Reprodutibilidade dos Testes , Fatores de Tempo , Transdutores de Pressão , Resultado do Tratamento
14.
Heart Vessels ; 34(3): 509-516, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30182157

RESUMO

Experimental data suggest that cryoenergy is associated with less endothelial damage and thrombus formation than radiofrequency energy. This study aimed to compare the impact of pulmonary vein isolation (PVI) on the endothelial damage, myocardial damage, inflammatory response, and prothrombotic state between the two latest technologies, second-generation cryoballoon (CB2) and contact force-sensing radiofrequency catheter (CFRF) ablation. Eighty-six paroxysmal atrial fibrillation (AF) patients (55 men; 65 ± 12 years) underwent PVI with either the CB2 (n = 64) or CFRF (n = 22). Markers of the endothelial damage (L-arginine/asymmetric dimethylarginine [ADMA]), myocardial injury (creatine kinase-MB [CK-MB], troponin-T, and troponin-I), inflammatory response (high-sensitive C-reactive protein), and prothrombotic state (D-dimer, soluble fibrin monomer complex, and thrombin-antithrombin complex) were determined before and up to 24-h post-procedure. The total application time was shorter (1,460 ± 287 vs. 2,395 ± 571 [sec], p < 0.01) and total procedure time tended to be shorter (199 ± 37 vs. 218 ± 38 [min], p = 0.06) with CB2 than CFRF ablation. The amount of myocardial injury was greater (CK-MB: 45 ± 17 vs. 11 ± 3 [IU/l], p < 0.01) with CB2 than CFRF ablation. The L-arginine/ADMA ratio was lower (160 ± 51 vs. 194 ± 38, p = 0.028) after CB2 than CFRF ablation. Inflammatory and all prothrombotic markers were significantly elevated post-ablation; however, the magnitude was similar between the two groups. During a mean follow-up of 20 ± 6 months, the single-procedure AF freedom was similar between the CB2 and CFRF groups (60/64 vs. 20/22, p = 0.82). CB2-PVI produces significantly lesser endothelial damage with greater myocardial injury than CFRF-PVI; however, similar anticoagulant regimens are required during the peri-procedural periods in both technologies.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Endotélio Vascular/fisiopatologia , Veias Pulmonares/cirurgia , Tromboembolia/etiologia , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Tromboembolia/fisiopatologia , Tromboembolia/prevenção & controle , Fatores de Tempo , Vasodilatação
15.
Heart Vessels ; 34(10): 1703-1709, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30953137

RESUMO

Cavo-tricuspid isthmus (CTI) anatomies are highly variable, and specific anatomies lead to a difficult CTI ablation. This study aimed to compare the clinical utility of angiography and intracardiac echocardiography (ICE) in evaluating CTI anatomies, and to investigate the impact of the CTI anatomy on the procedure when the ablation tactic was adjusted to the anatomy. This study included 92 consecutive patients who underwent a CTI ablation. The CTI morphology was assessed with both right atrial angiography and ICE before the ablation, and the ablation tactic was adjusted to the anatomy. The mean CTI length was 34 ± 9 mm. On ICE imaging, 21 (23%) patients had a flat CTI, while 41 (45%) had a concave CTI with a mean depth of 5.6 ± 2.7 mm. The remaining 30 (32%) had a distinct pouch with a mean depth of 6.4 ± 2.3 mm, located at the posterior, middle, and anterior isthmus in 15, 14, and 1 patients, respectively. The Eustachian ridge (ER) was visualized in 46 (50%) patients. On angiography, a pouch and ER were detected in 22 and 15 patients, but not in the remaining 8 and 31, respectively. A complete CTI block line was created in all patients without any complications. The CTI anatomy did not significantly impact any procedural parameters. ICE was superior to angiography in evaluating the detailed CTI anatomy, especially pouches and the ER. An adjustment of the ablation tactic to the anatomy could overcome the procedural difficulties of the CTI ablation in cases with specific anatomies.


Assuntos
Angiografia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Ecocardiografia , Sistema de Condução Cardíaco/anatomia & histologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Idoso , Artérias/anatomia & histologia , Artérias/diagnóstico por imagem , Artérias/patologia , Feminino , Átrios do Coração/anatomia & histologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Sistema de Condução Cardíaco/patologia , Septos Cardíacos/anatomia & histologia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/patologia , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Cuidados Intraoperatórios , Japão , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Resultado do Tratamento , Valva Tricúspide/anatomia & histologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/patologia
16.
Int Heart J ; 60(6): 1315-1320, 2019 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-31735780

RESUMO

Uninterrupted anticoagulation therapy during atrial fibrillation (AF) ablation minimizes the risk of periprocedural thromboembolic events. Although the use of direct oral anticoagulants (DOACs) has rapidly developed in patients undergoing AF ablation, no antidote is available for factor Xa inhibitors. We sought to investigate the feasibility of an uninterrupted DOAC protocol with temporary switching to dabigatran ("dabigatran bridge") for AF ablation.The study consisted of consecutive 137 patients in whom DOACs were interrupted on the procedural day with heparin bridging (interrupted group) and 135 in whom DOACs were uninterrupted with temporary switching to dabigatran during the periprocedural hospitalization period ("dabigatran bridge" group). The coagulation markers were measured just before and after the ablation procedure. The adverse events during and up to 8 weeks after the procedure were compared according to the definition of the International Society on Thrombosis and Hemostasis.The patients were significantly older in the "dabigatran bridge" group; however, the other baseline patient characteristics were similar between the two groups. The incidence of all adverse events was comparable between the two groups (8/137 versus 8/135, P = 0.96); however, one patient from the interrupted group experienced stroke, and another from the "dabigatran bridge" group experienced cardiac tamponade, which was safely managed with an antidote. In the "dabigatran bridge" group, the activated partial thromboplastin time was significantly longer, and coagulation markers (soluble fibrin monomer and thrombin-antithrombin complexes) were significantly lower than in the interrupted group before ablation.The "dabigatran bridge" seems to be a reasonable anticoagulation protocol to minimize the thromboembolic risk while ensuring safety in patients undergoing AF ablation and taking factor Xa inhibitors.


Assuntos
Antitrombinas/administração & dosagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Dabigatrana/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Tromboembolia/prevenção & controle , Administração Oral , Idoso , Protocolos Clínicos , Esquema de Medicação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Tromboplastina Parcial
17.
Front Cardiovasc Med ; 10: 1161691, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576113

RESUMO

Background: Mechanisms underlying atrial fibrillation (AF) are widely complex and vary tremendously among individuals. Objectives: This retrospective study aimed to investigate the association between AF activation patterns and clinical outcomes post-ablation. Methods: Fifty-five AF patients (64.0 ± 12.9 years; 41 men; 17 paroxysmal) underwent bi-atrial endocardial driver mapping during AF pre-ablation with a real-time phase mapping system (ExTRa Mapping). The nonpassively activated ratio (%NP) of meandering rotors and multiple wavelets relative to the recording time was evaluated in 26 atrial segments [15 in the left atrium (LA) and 11 in the right atrium]. Irrespective of the mapping results, all patients underwent standard AF ablation via cryoballoons and/or radiofrequency catheters. Results: In a median follow-up interval of 27(14-30) months, 69.1% of patients were free from recurrent arrhythmias and antiarrhythmic drugs at one year post-procedure. Patients with recurrent AF were more likely to have non-paroxysmal AF, a significantly larger LA size, and higher LA maximal %NP(LAmax%NP) and LA anterior wall %NP(LAAW%NP) than those without recurrent AF. A multivariate Cox regression analysis showed that both an LAmax%NP (hazard ratio [HR] = 1.075; 95% confidence interval [CI] = 1.02-1.14, p = 0.012) and LAAW%NP (HR = 1.061; 95% CI = 1.01-1.11, p = 0.013) were independent predictors of atrial arrhythmia recurrence. The optimal cutoff points for the LAmax%NP and LAAW%NP for predicting AF recurrence were 64.5% and 60.0%, respectively. A Kaplan-Meier analysis demonstrated that both an LAmax%NP > 64.5% (p = 0.0062) and LAAW%NP > 60.0% (p = 0.014) were associated with more frequent AF recurrences. Conclusion: Baseline AF activation pattern mapping may aid in predicting freedom from arrhythmias after standard AF ablation procedures.

18.
J Interv Card Electrophysiol ; 63(1): 143-152, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33575920

RESUMO

BACKGROUND: The novel fourth-generation cryoballoon (4th-CB) is characterized by a shorter-tip that potentially facilitates better time-to-isolation (TTI) monitoring. We sought to clarify the advantages and disadvantages of the 4th-CB compared to the second-generation cryoballoon (2nd-CB) in pulmonary vein isolation (PVI). METHODS: Forty-one and 49 consecutive atrial fibrillation patients underwent 2nd-CB and 4th-CB PVIs using 28-mm balloons and short freeze strategies. When effective freezing was not obtained, the CB was switched to the other CB. RESULTS: The rate of successful PVIs was significantly higher for 2nd-CBs than 4th-CBs (162/162[100%] vs. 178/193[92.2%] PVs, p < 0.0001). The difference was significant for lower PVs, especially right inferior PVs (RIPVs)(p = 0.005). In a total of 15 PVs in 11 patients, 4th-CBs were switched to 2nd-CBs, and 14/15(93.3%) PVs were successfully isolated. The balloon temperature tended to reach -55℃ more frequently with 2nd-CBs than 4th-CBs during RIPV ablations (15/41[36.6%] vs. 12/49[24.5%], p = 0.21). The TTI monitoring capability was significantly higher with 4th-CBs than 2nd-CBs (131/188[69.7%] vs. 83/160[51.9%] PVs, p = 0.0007). The difference was significant for right superior and left inferior PVs, but not for left superior PVs. Even if PVs requiring crossover were excluded, the total freeze duration (715±152 vs. 755±215 seconds, p = 0.31) tended to be shorter for 2nd-CBs than 4th-CBs. The incidence of phrenic nerve injury was similar for 2nd-CB and 4th-CB ablation (0/41 vs. 2/49, p = 0.12) CONCLUSIONS: The 4th-CB's shorter balloon tip enabled a significantly higher capability of TTI monitoring; however, it resulted in significantly lower rates of successful PVIs than the 2nd-CB, especially for the RIPVs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Congelamento , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
19.
J Interv Card Electrophysiol ; 64(2): 291-300, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33755817

RESUMO

BACKGROUND: A novel technology able to measure the local impedance (LI) during radiofrequency ablation has become available for clinical use. We investigated the change in the LI characteristics during superior vena cava isolations (SVCIs) using a novel catheter equipped with mini-electrodes. METHODS: Twenty paroxysmal atrial fibrillation patients (68 ± 9 years; 14 males) underwent an SVCI by targeting breakthroughs. Subsequently, dormant conduction provoked by adenosine triphosphate (ATP) was evaluated. RESULTS: Electrical SVCIs were successfully achieved in all with 7.2 ± 3.0 radiofrequency applications (RFA) without any complications. The procedure and fluoroscopic times were 13.1 ± 8.1 and 2.8 ± 2.3 min. No ablation was required at the anteroseptal SVC in 19 (95.0%) patients. The baseline LI and generator impedance (GI) were 125 ± 23 and 105 ± 14Ω. LI drops during RFA were significantly greater than GI drops (17 ± 12 vs. 4 ± 4Ω, p < 0.001). The correlation between the LI drops and GI drops was relatively high (R = 0.69, p < 0.001). LI drops were highest at the septal SVC and lowest at the lateral followed by antero-lateral SVC. The baseline electrogram amplitude between the mini-electrodes and tip-ring electrodes was 1.2 ± 1.4 and 0.8 ± 0.6 mV. The mini-electrode amplitude is more sharply attenuated with a greater magnitude than the tip-ring amplitude (p < 0.001). ATP-provoked dormant conduction was exposed in 10/17 (58.8%) patients and antero-lateral SVC gap locations in 7. Antero-lateral SVC LI drops were similar between patients with and without dormancy. CONCLUSIONS: The LI drop magnitude during RFA significantly differed among the SVC segments. Antero-lateral SVC ATP-provoked dormant conduction was often exposed, and additional applications are recommended following the isolation for a robust SVCI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Trifosfato de Adenosina , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Catéteres , Impedância Elétrica , Humanos , Masculino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
20.
Coron Artery Dis ; 32(4): 309-316, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33196580

RESUMO

BACKGROUND: An association between early repolarization and ventricular fibrillation has recently been reported in patients with vasospastic angina (VSA). However, no studies have clarified whether the presence of early repolarization can predict VSA. METHODS: Participants comprised 286 patients (136 males) with clinically suspected VSA who underwent intracoronary provocation tests using acetylcholine or ergonovine. Patients were divided into a VSA group [n = 94, positive provocation test as induction of coronary arterial spasm (>90% stenosis)] and a non-VSA group (n = 192). Detailed early repolarization data were compared between groups. RESULTS: The VSA group showed a higher frequency of smokers (28.7%) than the non-VSA group (17.2%; P = 0.02). On baseline 12-lead ECG, early repolarization (defined as a J-point elevation ≥0.1 mV from baseline in both or either of inferolateral leads) was found in 39 patients (inferior leads, n = 27; inferolateral leads, n = 12). Early repolarization was found more frequently in the VSA group (28.7%) than in the non-VSA group (6.2%, P < 0.01). Multivariate analysis revealed early repolarization as an independent predictor of VSA (odds ratio, 5.22; 95% confidence interval, 2.41-11.2; P < 0.01). Early repolarization pattern features including inferior lead, higher amplitude, notched type and horizontal/descending ST segments were associated with increased risk of VSA. CONCLUSION: In patients with resting chest pain, early repolarization was a predictor of VSA that could be particularly related to the inferior lead, higher amplitude, notched type and horizontal/descending ST segment.


Assuntos
Angina Pectoris Variante/fisiopatologia , Vasoespasmo Coronário/fisiopatologia , Eletrocardiografia , Acetilcolina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fibrilação Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA