Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Crit Care ; 24(1): 672, 2020 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-33267904

RESUMO

BACKGROUND: There is wide variability between intensivists in the decisions to forgo life-sustaining treatment (DFLST). Advance directives (ADs) allow patients to communicate their end-of-life wishes to physicians. We assessed whether ADs reduced variability in DFLSTs between intensivists. METHODS: We conducted a multicenter, prospective, simulation study. Eight patients expressed their wishes in ADs after being informed about DFLSTs by an intensivist-investigator. The participating intensivists answered ten questions about the DFLSTs of each patient in two scenarios, referring to patients' characteristics without ADs (round 1) and then with (round 2). DFLST score ranged from 0 (no-DFLST) to 10 (DFLST for all questions). The main outcome was variability in DFLSTs between intensivists, expressed as relative standard deviation (RSD). RESULTS: A total of 19,680 decisions made by 123 intensivists from 27 ICUs were analyzed. The DFLST score was higher with ADs than without (6.02 95% CI [5.85; 6.19] vs 4.92 95% CI [4.75; 5.10], p < 0.001). High inter-intensivist variability did not change with ADs (RSD: 0.56 (round 1) vs 0.46 (round 2), p = 0.84). Inter-intensivist agreement on DFLSTs was weak with ADs (intra-class correlation coefficient: 0.28). No factor associated with DFLSTs was identified. A qualitative analysis of ADs showed focus on end-of-life wills, unwanted things and fear of pain. CONCLUSIONS: ADs increased the DFLST rate but did not reduce variability between the intensivists. In the decision-making process using ADs, the intensivist's decision took priority. Further research is needed to improve the matching of the physicians' decision with the patient's wishes. Trial registration ClinicalTrials.gov Identifier: NCT03013530. Registered 6 January 2017; https://clinicaltrials.gov/ct2/show/NCT03013530 .


Assuntos
Diretivas Antecipadas/estatística & dados numéricos , Cuidados Críticos/normas , Tomada de Decisões , Médicos/psicologia , Suspensão de Tratamento/estatística & dados numéricos , Adulto , Cuidados Críticos/métodos , Cuidados Críticos/estatística & dados numéricos , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Médicos/estatística & dados numéricos , Estudos Prospectivos , Inquéritos e Questionários
2.
BMJ Open ; 9(11): e029761, 2019 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-31685496

RESUMO

INTRODUCTION: Difficult airway management during tracheal intubation can lead to severe hypoxic sequelae. Routine intubation practice is to use a strict supine position, whereas a 25° head-up or reverse Trendelenburg position increases efficacy of preoxygenation, seems more comfortable for the anaesthetist and may also provide better intubation conditions in direct laryngoscopy. The 25° head-up position could be used for the whole population rather than only for obese patients, but there is no prospective randomised controlled trial with a robust design and large number of patients comparing strict supine against 25° intubation in operating room. The objective of the InSize25 study is to test the effect of these two patient positions on intubation conditions during laryngoscopy in scheduled surgery on non-obese patients. METHODS AND ANALYSIS: InSize25 is an investigator-initiated, multicentre, open-label, two-arm, randomised controlled trial. The InSize25 study will randomise 1000 adult patients scheduled for surgery under general anaesthesia requiring intubation with neuromuscular-blocking drugs, candidates for direct laryngoscopy. The primary outcome variable is the view obtained during the first laryngoscopy without any external manipulation assessed using percentage of glottic opening. Important secondary outcomes are: Cormack-Lehane classification, number of attempts at laryngoscopy and at tracheal intubation, use of ancillary equipment (eg, bougies, alternative laryngoscope blades, videolaryngoscope) and manoeuvres (eg, laryngeal manipulation), comfort score for the anaesthetist, episodes of postinduction hypotension or desaturation and mechanical complications of intubation. ETHICS AND DISSEMINATION: The trial received appropriate approval from the 'CPP Sud-Est II' ethical review board. Informed consent is required. If the 25° head-up position proves superior for tracheal intubation without more complications, it may become the routine-standard intubation position rather than only for use with obese patients. The final results will be published in a peer-reviewed journal. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov identifier (NCT03339141).


Assuntos
Manuseio das Vias Aéreas/métodos , Decúbito Inclinado com Rebaixamento da Cabeça , Hipóxia/prevenção & controle , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Decúbito Dorsal , Anestesia Geral/métodos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA