Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Gastrointest Endosc ; 77(3): 319-27, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23410693

RESUMO

Biliary and pancreatic stents are used in a variety of benign and malignant conditions including strictures and leaks and in the prevention of post-ERCP pancreatitis.Both plastic and metal stents are safe, effective, and easy to use. SEMSs have traditionally been used for inoperable malignant disease. Covered SEMSs are now being evaluated for use in benign disease. Increasing the duration of patency of both plastic and metal stents remains an important area for future research.


Assuntos
Doenças Biliares/cirurgia , Pancreatopatias/cirurgia , Stents , Colangiopancreatografia Retrógrada Endoscópica , Desenho de Equipamento , Humanos , Metais , Plásticos , Stents/efeitos adversos , Stents/economia
2.
Gastrointest Endosc ; 76(1): 1-7, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22579259

RESUMO

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of new or emerging endoscopic technologies that have the potential to have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent preclinical and clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. For this review, the MEDLINE database was searched through January 2011 using the keywords "bariatric," "endoscopic," "intragastric balloon," "duodenojejunal bypass sleeve," and "transoral gastroplasty." Reports on Emerging Technologies are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. These reports are scientific reviews provided solely for educational and informational purposes. Reports on Emerging Technologies are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Assuntos
Endoscopia Gastrointestinal/métodos , Balão Gástrico , Obesidade/terapia , Próteses e Implantes , Toxinas Botulínicas/uso terapêutico , Endoscopia Gastrointestinal/instrumentação , Humanos , Neurotoxinas/uso terapêutico
3.
Gastrointest Endosc ; 73(3): 423-7, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21237458

RESUMO

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of new or emerging endoscopic technologies that have the potential to have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent preclinical and clinical studies on the topic, and a MAUDE (Manufacturer and User Facility Device Experience; U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized but, in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. For this review, the MEDLINE database was searched through January 2010 using the keywords "computer," "computerized," "computer-assisted," "sedation," "propofol." Reports on Emerging Technology are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. These reports are scientific reviews provided solely for educational and informational purposes. Reports on Emerging Technology are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Assuntos
Colonoscopia , Sedação Consciente/instrumentação , Sistemas de Liberação de Medicamentos/instrumentação , Monitoramento de Medicamentos/instrumentação , Propofol , Computadores , Sedação Consciente/métodos , Aprovação de Equipamentos , Humanos , Enfermeiras e Enfermeiros , Médicos , Software , Estados Unidos , United States Food and Drug Administration
4.
Gastrointest Endosc ; 74(3): 455-64, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21762904

RESUMO

The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2010 for articles related to enteral, esophageal, duodenal, and colonic stents. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Assuntos
Gastroenteropatias/terapia , Stents , Humanos , Stents/efeitos adversos , Stents/economia
5.
Gastrointest Endosc ; 72(2): 236-48, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20541746

RESUMO

The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but, in many cases, data from randomized, controlled trials are lacking. In such situations, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the ASGE Governing Board. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2009 for articles related to endoscopy in patients requiring enteral feeding access by using the keywords "endoscopy," "percutaneous," "gastrostomy," "jejunostomy," "nasogastric," "nasoenteric," "nasojejunal," "transnasal," "feeding tube," "enteric," and "button." Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Assuntos
Endoscópios Gastrointestinais/normas , Nutrição Enteral/instrumentação , Jejunostomia/instrumentação , Desenho de Equipamento , Humanos
6.
Gastrointest Endosc ; 72(2): 227-35, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20537638

RESUMO

The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, by using a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2009 for articles related to personal protection equipment by using the key words "personal protection equipment" (exp Protective Clothing/ or exp Protective Devices/ or exp Masks/ or exp Occupational Exposure/'') "infection control" paired with "Endoscopy." For the radiation section, the following key words were used: "radiation and endoscopy," "radiation and ERCP," and "radiation safety." For the ergonomics section, the following key words were used: "ergonomics of endoscopy," "endoscopist injury," "medical ergonomics," "endoscopy and musculoskeletal strain," "musculoskeletal injury and endoscopists," "occupational diseases and endoscopy," "cumulative trauma disorder and endoscopy," "repetitive strain injury and endoscopy." Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.


Assuntos
Endoscópios/normas , Endoscopia/normas , Ergonomia/métodos , Exposição Ocupacional/prevenção & controle , Equipamentos de Proteção/normas , Liberação Nociva de Radioativos/prevenção & controle , Gestão da Segurança/métodos , Segurança de Equipamentos , Humanos
7.
Gastrointest Endosc ; 70(1): 9-17, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19394009

RESUMO

BACKGROUND: Autofluorescence imaging is a novel imaging technique that may improve the detection of early neoplasia in Barrett's esophagus. Autofluorescence imaging is, however, associated with a 40% to 81% false-positive rate. OBJECTIVE: Our purpose was to identify endoscopic features that may predict the presence of early neoplasia in autofluorescence-positive areas. DESIGN: Descriptive and prospective cohort study. SETTING: Tertiary referral centers for the detection and treatment of early Barrett's neoplasia. PATIENTS AND METHODS: Patients undergoing autofluorescence endoscopy. High-quality images with autofluorescence imaging and white-light endoscopy were obtained with corresponding histologic study. A systematic image evaluation process was performed, including an unblinded orientation phase (10 areas), a blinded derivation phase, and a blinded validation phase by 5 international experts in autofluorescence imaging (80 areas). Subsequently the identified features were validated in a prospective pilot study. MAIN OUTCOME MEASUREMENTS: Association between endoscopic features and presence of early neoplasia in autofluorescence-positive areas. RESULTS: Autofluorescence intensity, proximity of gastric folds <1 cm, and different appearance on white-light endoscopy were independently associated with early neoplasia in autofluorescence-positive areas on multivariate analysis. The kappa values for interobserver agreement of these factors were moderate, ranging between 0.49 to 0.56. The association with autofluorescence intensity and different appearance on white-light endoscopy was confirmed in a prospective pilot study. LIMITATION: Selected set of images from a high-risk population (tertiary referral center). CONCLUSION: We found specific endoscopic features that were associated with early neoplasia in autofluorescence-positive areas. These findings can be used in future prospective studies to improve the accuracy of autofluorescence imaging without performing magnification endoscopy for detailed inspection of suspicious areas.


Assuntos
Esôfago de Barrett/diagnóstico , Endoscopia Gastrointestinal/métodos , Neoplasias Esofágicas/diagnóstico , Fluorescência , Mucosa Intestinal/patologia , Medição de Risco/métodos , Idoso , Esôfago de Barrett/complicações , Esôfago de Barrett/epidemiologia , Biópsia , Diagnóstico Diferencial , Neoplasias Esofágicas/etiologia , Feminino , Seguimentos , Humanos , Masculino , Países Baixos/epidemiologia , Projetos Piloto , Prevalência , Prognóstico , Estudos Prospectivos , Fatores de Risco , Método Simples-Cego , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA