Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Chem ; 58(2): 458-64, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22166252

RESUMO

BACKGROUND: The diagnostic accuracy of serum creatinine and cystatin C (Cys) as early predictors of contrast-induced nephropathy (CIN) has been debated. We investigated the diagnostic sensitivities, diagnostic specificities, and variations from baseline for serum creatinine and Cys in CIN. METHODS: We prospectively evaluated 166 patients at risk for CIN at baseline, and at 12, 24, and 48 h after exposure to contrast media. CIN occurred in 30 patients (18%). Changes (Δ) compared to baseline in serum creatinine and Cys were evaluated at the predefined time points. ROC curve analysis was performed for the Δ 12-h basal serum creatinine and Cys. RESULTS: The Δ serum creatinine at 12 h from baseline was the earliest predictor of CIN [area under the ROC curve (AUC) = 0.80; P < 0.001]. The Δ serum creatinine 15% variation [0.15 mg/dL (13.2 µmol/L)] yielded 43% diagnostic sensitivity and 93% diagnostic specificity. The ΔCys at 12 h from baseline performed significantly worse than serum creatinine (AUC = 0.48; P = 0.74). CONCLUSIONS: Variations from the serum creatinine baseline offer better diagnostic accuracy for predicting CIN at an earlier stage than similar variations in Cys. An additional diagnostic value of Cys over the determination of serum creatinine in the setting of CIN was not observed.


Assuntos
Injúria Renal Aguda/diagnóstico , Meios de Contraste/efeitos adversos , Creatinina/sangue , Cistatina C/sangue , Injúria Renal Aguda/induzido quimicamente , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
2.
Virchows Arch ; 480(6): 1223-1230, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35212813

RESUMO

Meningiomas are common tumors of the central nervous system. Although their histological diagnosis is usually straightforward, their differential diagnosis versus other tumors may be challenging at times. The objective of this study is to assess the diagnostic value of CD13 immunoexpression in the differential diagnosis between meningiomas and their morphological mimics. Immunohistochemical analysis for CD13, epithelial membrane antigen, SOX10, and STAT6 was carried out in a large cohort of primary meningeal tumors comprising 225 meningiomas, 15 schwannomas, and 20 solitary fibrous tumor/hemangiopericytomas. Within the meningioma group, the expression of CD13 and epithelial membrane antigen was distinguished in three categories using a semiquantitative score. Most of meningiomas expressed CD13 (94%) and epithelial membrane antigen (96%) while none of the schwannomas nor of the solitary fibrous tumor/hemangiopericytomas was positive for either the two markers. Diffuse positivity for CD13 and epithelial membrane antigen was more common in low-grade meningiomas than in anaplastic ones, which were also more often negative for such markers, especially for CD13 (32%). CD13 is a helpful immunohistochemical marker for the differential diagnosis of meningiomas and their mimics, achieving in combination with epithelial membrane antigen maximal sensitivity (100%) and showing statistically relevant difference of expression in comparison with both schwannomas (p < 0.0001) and solitary fibrous tumor/hemangiopericytomas (p < 0.0001). Furthermore, loss of CD13 expression could be related to outcome as it is associated with worrisome histological findings, mainly in the setting of anaplastic meningiomas.


Assuntos
Hemangiopericitoma , Neoplasias Meníngeas , Meningioma , Neurilemoma , Tumores Fibrosos Solitários , Diagnóstico Diferencial , Hemangiopericitoma/diagnóstico , Hemangiopericitoma/patologia , Humanos , Imuno-Histoquímica , Neoplasias Meníngeas/diagnóstico , Neoplasias Meníngeas/patologia , Meningioma/diagnóstico , Meningioma/patologia , Mucina-1 , Neurilemoma/diagnóstico , Neurilemoma/patologia , Prognóstico , Tumores Fibrosos Solitários/diagnóstico , Tumores Fibrosos Solitários/patologia
3.
Nephrol Dial Transplant ; 24(5): 1490-4, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19037085

RESUMO

BACKGROUND: Albuminuria is a sensitive marker of renal derangement and has been included in a number of studies investigating chronic kidney diseases (CKDs). This study is aimed to evaluate the diagnostic performances of a strip for measuring the albumin/creatinine ratio (ACR) in the general population and to compare it with those found in a diabetic population. METHODS: Urine samples were obtained from 201 consecutive subjects enrolled in an epidemiological study and from 259 type 2 diabetic patients. Urine was tested for albumin and creatinine using the strip (Clinitek Microalbumin) and laboratory methods. A hundred samples were stored under various conditions to assess analyte stability. RESULTS: In the general population, the strip test reached a 90% sensitivity and 91% specificity, considering the laboratory method as the 'gold standard', sparing >80% of subjects the laboratory tests at the expense of a 1% false negative rate and an 8% false positive rate. Regarding sensitivity and specificity, the ACR test performs very similarly in the general population and in the diabetics. The stability study showed that storage at -20 degrees C induced a significant decrease in the albumin concentration with both methods, such that 5% of the samples were re-classified in the lower ACR class. Storage at -80 degrees C for up to 12 months did not affect the measurement with both methods. CONCLUSION: Clinitek Microalbumin strips can be used for screening purposes in the general population since they correctly classify a significant percentage of subjects, particularly those with a normal albuminuria. Storage at -80 degrees C does not affect strip results. Screening with the strip and confirming positive results with a wet chemistry method are an efficient strategy for detecting albuminuria in the general population.


Assuntos
Albuminúria/diagnóstico , Programas de Rastreamento/métodos , Fitas Reagentes , Albuminúria/urina , Creatinina/urina , Diabetes Mellitus Tipo 2/urina , Humanos , Fitas Reagentes/normas , Sensibilidade e Especificidade , Temperatura
4.
J Pathol Inform ; 9: 34, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30450263

RESUMO

INTRODUCTION: Whole-slide imaging (WSI) technology can be used for primary diagnosis and consultation, including intraoperative (IO) frozen section (FS). We aimed to implement and validate a digital system for the FS evaluation of cancer and transplant specimens following recommendations of the College of American Pathologists. MATERIALS AND METHODS: FS cases were routinely scanned at ×20 employing the "Navigo" scanner system. IO diagnoses using glass versus digital slides after a 3-week washout period were recorded. Intraobserver concordance was evaluated using accuracy rate and kappa statistics. Feasibility of WSI diagnoses was assessed by the way of sensitivity, specificity, as well as positive and negative predictive values. Participants also completed a survey denoting scan time, time spent viewing cases, preference for glass versus WSI, image quality, interface experience, and any problems encountered. RESULTS: Of the 125 cases submitted, 121 (436 slides) were successfully scanned including 93 oncological and 28 donor-organ FS biopsies. Four cases were excluded because of failed digitalization due to scanning problems or sample preparation artifacts. Full agreement between glass and digital-slide diagnosis was obtained in 90 of 93 (97%, κ = 0.96) oncology and in 24 of 28 (86%, κ = 0.91) transplant cases. There were two major and one minor discrepancy for cancer cases (sensitivity 100%, specificity 96%) and two major and two minor disagreements for transplant cases (sensitivity 96%, specificity 75%). Average scan and viewing/reporting time were 12 and 3 min for cancer cases, compared to 18 and 5 min for transplant cases. A high diagnostic comfort level among pathologists emerged from the survey. CONCLUSIONS: These data demonstrate that the "Navigo" digital WSI system can reliably support an IO FS service involving complicated cancer and transplant cases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA