Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38400904

RESUMO

OBJECTIVES: To evaluate the technical success and outcomes of renal biopsies performed under magnetic resonance imaging (MRI) using a closed-bore, 1.5-Tesla MRI unit. MATERIALS AND METHODS: We retrospectively reviewed our institutional biopsy database and included 150 consecutive MRI-guided biopsies for renal masses between November 2007 and March 2020. We recorded age, sex, BMI, tumor characteristics, RENAL nephrometry score, MRI scan sequence, biopsy technique, complications, diagnostic yield, pathologic outcome, and follow-up imaging. Univariate logistic regression was used to assess the association between different parameters and the development of complications. McNemar's test was used to assess the association between paired diagnostic yield measurements for fine-needle aspiration and core samples. RESULTS: A total of 150 biopsies for 150 lesions were performed in 150 patients. The median tumor size was 2.7 cm. The median BMI was 28.3. The lesions were solid, partially necrotic/cystic, and predominantly cystic in 137, eight, and five patients, respectively. Image guidance using fat saturation steady-state free precession sequence was recorded in 95% of the biopsy procedures. Samples were obtained using both fine-needle aspiration (FNA) and cores in 99 patients (66%), cores only in 40 (26%), and FNA only in three (2%). Tissue sampling was diagnostic in 144 (96%) lesions. No major complication developed following any of the biopsy procedures. The median follow-up imaging duration was 8 years and none of the patients developed biopsy-related long-term complication or tumor seeding. CONCLUSIONS: MRI-guided renal biopsy is safe and effective, with high diagnostic yield and no major complications. CLINICAL RELEVANCE STATEMENT: Image-guided renal biopsy is safe and effective, and should be included in the management algorithm of patients with renal masses. Core biopsy is recommended. KEY POINTS: • MRI-guided biopsy is a safe and effective technique for sampling of renal lesions. • MRI-guided biopsy has high diagnostic yield with no major complications. • Percutaneous image-guided biopsy plays a key role in the management of patients with renal masses.

2.
Environ Monit Assess ; 195(1): 61, 2022 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-36326936

RESUMO

Siwa Oasis is of great historical, environmental, and scientific importance, as it contains unique archeological and geological features. Groundwater is the main source of freshwater in that oasis. The carbonate aquifer groundwater, used for irrigation, was sampled to evaluate factors controlling quality changes spatially and temporally by applying hydrochemical and statistical analyses. The salinity of the aquifer varied spatially from 1367 to 8645 mg/l based on one hydrogeological condition, with the highest TDS (> 5432.5 mg/l, 25% of samples) at the central part of the study area. Temporally, the salinity changed slightly from 3754.3 mg/l (in 2014) to 4222.4 mg/l (in 2020). The cession of illegal wells, pumping control, and excavation of formed salts have a noticeable impact on salinity (mediate the increase in salinity) and ions. However, about 61% of the studied samples can be considered unsuitable for irrigation owing to salinity and can harm plant yield. The heavy metals studied (Fe, Mn, Cu, Pb), except Cd, were within the permissible limit for irrigation water. Finally, it is proposed to construct desalination stations to enhance water quality for irrigation in the study area and set up many companies for salt extraction.


Assuntos
Água Subterrânea , Poluentes Químicos da Água , Monitoramento Ambiental , Água Subterrânea/análise , Qualidade da Água , Poços de Água , Salinidade , Poluentes Químicos da Água/análise
3.
Int J Hyperthermia ; 37(2): 53-60, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32672122

RESUMO

PURPOSE: The aim of this paper is to discuss the current evidence for Laser Interstitial Thermal Therapy (LITT) in the treatment of brain metastases, our current recommendations for patient selection and the future perspectives for this therapy. We have also touched upon the possible complications and role of systemic therapy coupled with LITT for the treatment of brain metastases. MATERIAL AND METHODS: Two authors carried out the literature search using two databases independently, including PubMed, and Web of Science. The review included prospective and retrospective studies using LITT to treat brain metastases. RESULTS: Twenty-two original articles were analyzed in this review, particularly clinical outcomes and complications. We have also provided our institutional experience in the use of LITT to treat brain metastases and addressed future perspectives for the use of this technology. CONCLUSIONS: The current literature supports LITT as a safe and effective therapy for patients with brain metastases that have failed SRS. Larger studies are still required to better evaluate the use of systemic therapy in concomitance with LITT. New images modalities may enable optimized treatment and outcomes.


Assuntos
Neoplasias Encefálicas , Hipertermia Induzida , Terapia a Laser , Neoplasias Encefálicas/cirurgia , Humanos , Lasers , Estudos Prospectivos , Estudos Retrospectivos
4.
Mol Imaging ; 17: 1536012118799131, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30246593

RESUMO

The use of short-wave infrared (SWIR) light for fluorescence bioimaging offers the advantage of reduced photon scattering and improved tissue penetration compared to traditional shorter wavelength imaging approaches. While several nanomaterials have been shown capable of generating SWIR emissions, rare-earth-doped nanoparticles (REs) have emerged as an exceptionally bright and biocompatible class of SWIR emitters. Here, we demonstrate SWIR imaging of REs for several applications, including lymphatic mapping, real-time monitoring of probe biodistribution, and molecular targeting of the αvß3 integrin in a tumor model. We further quantified the resolution and depth penetration limits of SWIR light emitted by REs in a customized imaging unit engineered for SWIR imaging of live small animals. Our results indicate that SWIR light has broad utility for preclinical biomedical imaging and demonstrates the potential for molecular imaging using targeted REs.


Assuntos
Raios Infravermelhos , Integrina alfaVbeta3/metabolismo , Metais Terras Raras/química , Imagem Molecular , Terapia de Alvo Molecular , Nanopartículas/química , Animais , Linhagem Celular Tumoral , Feminino , Fluorescência , Humanos , Camundongos Nus , Nanopartículas/ultraestrutura , Peptídeos Cíclicos/química
5.
Int J Hyperthermia ; 34(7): 943-952, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29343140

RESUMO

We evaluated a physics-based model for planning for magnetic resonance-guided laser interstitial thermal therapy for focal brain lesions. Linear superposition of analytical point source solutions to the steady-state Pennes bioheat transfer equation simulates laser-induced heating in brain tissue. The line integral of the photon attenuation from the laser source enables computation of the laser interaction with heterogeneous tissue. Magnetic resonance thermometry data sets (n = 31) were used to calibrate and retrospectively validate the model's thermal ablation prediction accuracy, which was quantified by the Dice similarity coefficient (DSC) between model-predicted and measured ablation regions (T > 57 °C). A Gaussian mixture model was used to identify independent tissue labels on pre-treatment anatomical magnetic resonance images. The tissue-dependent optical attenuation coefficients within these labels were calibrated using an interior point method that maximises DSC agreement with thermometry. The distribution of calibrated tissue properties formed a population model for our patient cohort. Model prediction accuracy was cross-validated using the population mean of the calibrated tissue properties. A homogeneous tissue model was used as a reference control. The median DSC values in cross-validation were 0.829 for the homogeneous model and 0.840 for the heterogeneous model. In cross-validation, the heterogeneous model produced a DSC higher than that produced by the homogeneous model in 23 of the 31 brain lesion ablations. Results of a paired, two-tailed Wilcoxon signed-rank test indicated that the performance improvement of the heterogeneous model over that of the homogeneous model was statistically significant (p < 0.01).


Assuntos
Terapia a Laser/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
J Opt Soc Am A Opt Image Sci Vis ; 34(5): A1-A9, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28463329

RESUMO

Simultaneous range compression and aperture synthesis is experimentally demonstrated with a stepped linear frequency modulated waveform and holographic aperture ladar. The resultant three-dimensional (3D) data has high resolution in the aperture synthesis dimension and is recorded using a conventional low bandwidth focal plane array. Individual cross-range field segments are coherently combined using data driven registration and phase correction methods allowing range compression to be performed without the benefit of a coherent waveform. Furthermore, we demonstrate a synergistically enhanced ability to discriminate image objects due to the coaction of range compression and aperture synthesis. We show that two objects can be precisely located in 3D space, despite being unresolved in two directions, due to resolution gains in both the range and azimuth cross-range dimensions.

7.
Appl Opt ; 55(17): 4611-20, 2016 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-27409018

RESUMO

Three-dimensional (3D) holographic ladar uses digital holography with frequency diversity to add the ability to resolve targets in range. A key challenge is that since individual frequency samples are not recorded simultaneously, differential phase aberrations may exist between them, making it difficult to achieve range compression. We describe steps specific to this modality so that phase gradient algorithms (PGA) can be applied to 3D holographic ladar data for phase corrections across multiple temporal frequency samples. Substantial improvement of range compression is demonstrated with a laboratory experiment where our modified PGA technique is applied. Additionally, the PGA estimator is demonstrated to be efficient for this application, and the maximum entropy saturation behavior of the estimator is analytically described.

8.
Small ; 11(32): 4002-8, 2015 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-25973916

RESUMO

Beta-emitting isotopes Fluorine-18 and Yttrium-90 are tested for their potential to stimulate gold nanoclusters conjugated with blood serum proteins (AuNCs). AuNCs excited by either medical radioisotope are found to be highly effective ionizing radiation energy transfer mediators, suitable for in vivo optical imaging. AuNCs synthesized with protein templates convert beta-decaying radioisotope energy into tissue-penetrating optical signals between 620 and 800 nm. Optical signals are not detected from AuNCs incubated with Technetium-99m, a pure gamma emitter that is used as a control. Optical emission from AuNCs is not proportional to Cerenkov radiation, indicating that the energy transfer between the radionuclide and AuNC is only partially mediated by Cerenkov photons. A direct Coulombic interaction is proposed as a novel and significant mechanism of energy transfer between decaying radionuclides and AuNCs.


Assuntos
Transferência de Energia , Ouro/química , Nanopartículas Metálicas/química , Imagem Molecular/métodos , Radioisótopos/química , Animais , Bovinos , Linhagem Celular Tumoral , Humanos , Camundongos , Reprodutibilidade dos Testes , Soroalbumina Bovina
9.
HardwareX ; 16: e00471, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37771323

RESUMO

Graphene and related two-dimensional materials (2DMs) have shown promise across numerous technology areas including flexible electronics, energy storage and pollution remediation. Research into novel applications of these atomically thin materials relies on access to synthesis techniques for producing 2DMs with suitable quality and quantity. Liquid-phase exfoliation is a mechanochemical approach that can achieve this and produce defect-free nanomaterial dispersions which are compatible for downstream use (e.g. inkjet printing, coatings). Here, using kitchen blenders to deliver shear-driven exfoliation, we develop a range of inexpensive hardware solutions that can allow researchers to synthesise 2DMs using a controllable, sustainable and scalable process. Extensive modifications were necessary as the onboard electronics lack the experimental controls (temperature, speed, characterisation) for scientific research and precision synthesis. The technical aspects (including the many lessons learned) of the modifications are discussed and a simple selection process is proposed for creating bespoke mechanochemical processors for any application in the hope that this encourages experimentation. Specific builds with detailed notes, cost breakdown and associated files are provided in the Open Science Framework (OSF) repository, OpenLPE associated with this article.

10.
AJR Am J Roentgenol ; 199(5): W651-3, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23096211

RESUMO

OBJECTIVE: The purpose of this study was to test the feasibility of 3-T vacuum-assisted large-bore core biopsy of lesions detected with MRI of the breast. CONCLUSION: Our preliminary experience revealed that 3-T MRI-guided vacuum-assisted biopsy is a safe and effective interventional method that enables accurate biopsy of lesions identified with a 3-T MRI system. Artifacts on 3-T images did not result in failed biopsy; therefore, 3-T MRI systems can be used reliably for both diagnostic and interventional breast studies.


Assuntos
Biópsia por Agulha/métodos , Neoplasias da Mama/patologia , Imagem por Ressonância Magnética Intervencionista/métodos , Adulto , Idoso , Artefatos , Estudos de Viabilidade , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Vácuo
11.
Ind Eng Chem Res ; 61(44): 16529-16538, 2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36398202

RESUMO

A major transition to electric vehicles (EVs) is underway globally, as countries target reductions in greenhouse gas emissions from the transport sector. As this rapid growth continues, significant challenges remain around how to sustainably manage the accompanying large volumes of waste from end-of-life lithium-ion batteries that contain valuable rare earth and critical materials. Here, we show that high-shear exfoliation in aqueous surfactants can upcycle spent graphite anodes recovered from an EV into few-layer graphene dispersions. For the same hydrodynamic conditions, we report a process yield that is 37.5% higher when using spent graphite anodes as the precursor material over high-purity graphite flakes. When the surfactant concentration is increased, the average atomic layer number reduces in a similar way to that of high-purity precursors. We find that the electrical conductance of few-layer graphene produced using the graphite flake precursor is superior and identify the limitations when using aqueous surfactant solutions as the exfoliation medium for spent graphite anode material. Using these nontoxic solution-processable nanomaterial dispersions, functional paper-based electronic circuit boards were fabricated, illustrating the potential for end-to-end, environmentally sustainable upcycling of spent EV anodes into new technologies.

12.
Opt Express ; 19(25): 25048-56, 2011 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-22273896

RESUMO

Multi-transmitter aperture synthesis provides aperture gain and improves effective aperture fill factor by shifting the received speckle field through the use of multiple transmitter locations. It is proposed that by utilizing methods based on shearing interferometry some low-order aberrations, such as defocus, can be found directly rather than through iterative algorithms. The current work describes the theory behind multi-transmitter aberration correction and describes experiments used to validate this method. Experimental results are shown which demonstrate the ability of such a sensor to solve directly for defocus and toric curvature in the captured field values.


Assuntos
Artefatos , Desenho Assistido por Computador , Modelos Teóricos , Dispositivos Ópticos , Telecomunicações/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Espalhamento de Radiação
13.
Environ Pollut ; 268(Pt A): 115654, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33068845

RESUMO

Brakes, tyres and road deposits have become important contributors to the overall particle emissions of vehicles globally, with constituents in these wear particles considered to be harmful to human health (PM10 and PM2.5). Previous research has documented mass/size distributions, physical and chemical characteristics, emission factors and long-term implications and environmental occurrences. The complex path these pollutants take from their origins to the environment, however, is not fully understood. This is partly owing to the breadth of spatio-temporal scales involved in the advection-diffusion processes (nanometers to meters, microseconds to minutes). These short timescale particle transport mechanisms impact human exposure, such as pedestrians and cyclists, and initiate the long-term interaction of these pollutants with other environmental compartments. Here, we present an analysis for urban driving conditions to highlight the opportunities to reveal these complex pathways and formulate opinions that aim to stimulate future enquiry. We describe important vehicular areas and exposure scenarios where efforts should focus. Future interdisciplinary research into these particle transport mechanisms must be prioritised as it can provide the foundation for developing urgently needed pollution control strategies, transport infrastructure layouts and transport policies that mitigate, or possibly eliminate pollution exposure risks.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Exposição Ambiental , Monitoramento Ambiental , Humanos , Tamanho da Partícula , Material Particulado/análise , Emissões de Veículos/análise
14.
Med Phys ; 48(9): e772-e806, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34224149

RESUMO

Magnetic resonance-guided focused ultrasound (MRgFUS) is a completely non-invasive technology that has been approved by FDA to treat several diseases. This report, prepared by the American Association of Physicist in Medicine (AAPM) Task Group 241, provides background on MRgFUS technology with a focus on clinical body MRgFUS systems. The report addresses the issues of interest to the medical physics community, specific to the body MRgFUS system configuration, and provides recommendations on how to successfully implement and maintain a clinical MRgFUS program. The following sections describe the key features of typical MRgFUS systems and clinical workflow and provide key points and best practices for the medical physicist. Commonly used terms, metrics and physics are defined and sources of uncertainty that affect MRgFUS procedures are described. Finally, safety and quality assurance procedures are explained, the recommended role of the medical physicist in MRgFUS procedures is described, and regulatory requirements for planning clinical trials are detailed. Although this report is limited in scope to clinical body MRgFUS systems that are approved or currently undergoing clinical trials in the United States, much of the material presented is also applicable to systems designed for other applications.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Imagem por Ressonância Magnética Intervencionista , Cirurgia Assistida por Computador , Imageamento por Ressonância Magnética , Estados Unidos
15.
Opt Express ; 18(10): 10334-42, 2010 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-20588888

RESUMO

Distributed aperture synthesis is an exciting technique for recovering high-resolution images from an array of small telescopes. Such a system requires optical field values measured at individual apertures to be phased together so that a single, high-resolution image can be synthesized. This paper describes the application of sharpness metrics to the process of phasing multiple coherent imaging systems into a single high-resolution system. Furthermore, this paper will discuss hardware and present the results of simulations and experiments which will illustrate how aperture synthesis is performed.


Assuntos
Astronomia/instrumentação , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Lentes , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Opt Express ; 18(24): 24937-45, 2010 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-21164838

RESUMO

Multi-transmitter aperture synthesis is a method in which multiple transmitters can be used to improve resolution and contrast of distributed aperture systems. Such a system utilizes multiple transmitter locations to interrogate a target from multiple look angles thus increasing the angular spectrum content captured by the receiver aperture array. Furthermore, such a system can improve the contrast of sparsely populated receiver arrays by capturing field data in the region between sub-apertures by utilizing multiple transmitter locations. This paper discusses the theory behind multi-transmitter aperture synthesis and provides experimental verification that imagery captured using multiple transmitters will provide increased resolution.

17.
Appl Opt ; 49(12): 2262-70, 2010 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-20411005

RESUMO

By synthesizing large effective apertures through the translation of a smaller imaging sensor and the subsequent proper phasing and correlation of detected signals in postprocessing, holographic aperture ladar (HAL) systems seek to increase the resolution of remotely imaged targets. The stripmap HAL process was demonstrated in the laboratory, for the first time to our knowledge. Our results show that the stripmap HAL transformation can precisely account for off-axis transmitter induced phase migrations. This in turn allows multiple pupil plane field segments, sequentially collected across a synthetic aperture, to be coherently mosaiced together. As a direct consequence, we have been able to confirm the capability of the HAL method to potentially provide substantial increases in longitudinal cross-range resolution. The measurement and sampling of complex pupil plane field segments, as well as target related issues arising from short laboratory ranges, have also been addressed.

18.
Cancer Lett ; 489: 9-18, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32504657

RESUMO

Stereotactic Radiosurgery has become the main treatment for patients with limited number of brain metastases (BM). Recently, with the increasing use of this modality, there is a growth in recurrence cases. Recurrence after radiation therapy can be divided in changes favoring either tumor recurrence or radiation necrosis (RN). Laser Interstitial Thermal Therapy (LITT) is minimally invasive treatment modality that has been used to treat primary and metastatic brain tumors. When associated with real-time thermometry using Magnetic Resonance Imaging, the extent of ablation can be controlled to provide maximum coverage and avoid eloquent areas. The objective of this study was to investigate the use of LITT in the treatment of BM. An extensive review of the relevant literature was conducted and the outcome results are discussed. There is an emphasis on safety and local control rate of patients treated with this modality. The findings of our study suggest that LITT is a viable safe technique to treat recurrent BM, especially in patients with deep-seated lesions where surgical resection is not an option.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/terapia , Terapia a Laser/métodos , Lesões por Radiação/terapia , Humanos , Necrose/etiologia , Lesões por Radiação/etiologia , Radiocirurgia/efeitos adversos
19.
Mol Cancer Ther ; 7(6): 1730-9, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18566244

RESUMO

Laser-induced phototherapy is a new therapeutic use of electromagnetic radiation for cancer treatment. The use of targeted plasmonic gold nanoparticles can reduce the laser energy necessary for selective tumor cell destruction. However, the ability for targeted delivery of the currently used gold nanoparticles to tumor cells is limited. Here, we describe a new class of molecular specific photothermal coupling agents based on hollow gold nanoshells (HAuNS; average diameter, approximately 30 nm) covalently attached to monoclonal antibody directed at epidermal growth factor receptor (EGFR). The resulting anti-EGFR-HAuNS exhibited excellent colloidal stability and efficient photothermal effect in the near-infrared region. EGFR-mediated selective uptake of anti-EGFR-HAuNS in EGFR-positive A431 tumor cells but not IgG-HAuNS control was shown in vitro by imaging scattered light from the nanoshells. Irradiation of A431 cells treated with anti-EGFR-HAuNS with near-infrared laser resulted in selective destruction of these cells. In contrast, cells treated with anti-EGFR-HAuNS alone, laser alone, or IgG-HAuNS plus laser did not show observable effect on cell viability. Using 111In-labeled HAuNS, we showed that anti-EGFR-HAuNS could be delivered to EGFR-positive tumors at 6.8% ID/g, and the microscopic image of excised tumor with scattering signal from nanoshells confirmed preferential delivery to A431 tumor of anti-EGFR-HAuNS compared with IgG-HAuNS. The absence of silica core, the relatively small particle size and high tumor uptake, and the absence of cytotoxic surfactant required to stabilize other gold nanoparticles suggest that immuno-HAuNS have the potential to extend to in vivo molecular therapy.


Assuntos
Receptores ErbB/antagonistas & inibidores , Ouro/farmacologia , Fototerapia/métodos , Animais , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/farmacocinética , Anticorpos Monoclonais/farmacologia , Linhagem Celular Tumoral , Ouro/administração & dosagem , Ouro/farmacocinética , Humanos , Raios Infravermelhos , Camundongos , Camundongos Nus , Nanopartículas/ultraestrutura , Neoplasias/patologia , Soluções , Ensaios Antitumorais Modelo de Xenoenxerto
20.
J Immunother Cancer ; 7(1): 329, 2019 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-31779702

RESUMO

BACKGROUND: Currently, there are no imaging predictors of immunotherapy outcome in hepatocellular carcinoma (HCC). The study aim was to determine if stiffness changes measured by magnetic resonance elastography (MRE) can be a predictor of immunotherapy response in patients with advanced HCC. MATERIALS AND METHODS: This was a prospective study of 15 patients with biopsy proven-advanced HCC treated with Pembrolizumab. All patients had liver MRE and liver biopsy at baseline and at 6 weeks of therapy. Change in HCC stiffness on MRE was compared with overall survival (OS), time to disease progression (TTP), and number of intratumoral CD3+ T lymphocytes. Analysis was performed using descriptive statistics and Spearman correlation (R); p-value < 0.05 was considered statistically significant. RESULTS: Nine patients were evaluable. Median age was 71 years (range, 54-78). Etiology of liver disease was HCV (n = 4), HBV (n = 1) and NASH (n = 4). Median OS and TTP were 44 weeks and 13 weeks, respectively. Average baseline HCC stiffness and change in HCC stiffness were 5.0 kPa and 0.12 kPa, respectively. In contrast, average non-tumor liver stiffness was 3.2 kPa, and did not significantly change at 6 weeks (p = 0.42). Average size of measured tumor and change in size were 4 cm and - 0.32 cm, respectively. Change in HCC stiffness at 6 weeks correlated significantly with OS (R = 0.81), and TTP (R = 0.88,p < 0.01). Abundance of intratumoral T lymphocytes on tumor biopsy correlated significantly with HCC stiffness (R = 0.79,p = 0.007). CONCLUSION: Our pilot MRE data suggests early change in tumor stiffness may be an indicator of immunotherapy response in patients with advanced HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Idoso , Biomarcadores , Biópsia , Carcinoma Hepatocelular/terapia , Feminino , Humanos , Imunoterapia , Neoplasias Hepáticas/terapia , Linfócitos do Interstício Tumoral/imunologia , Linfócitos do Interstício Tumoral/metabolismo , Linfócitos do Interstício Tumoral/patologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Índice de Gravidade de Doença , Resultado do Tratamento , Microambiente Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA