Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Mass Spectrom Rev ; 40(5): 628-646, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-32722885

RESUMO

Mass spectrometry is commonly used in forensic chemistry laboratories for sensitive, definitive analysis. There have been significant efforts to bring mass spectrometry analysis on-site through the development of ruggedized, fieldable instruments. Testing samples in the field is of particular interest in forensic science, homeland security, and defense applications. In forensic chemistry, testing seized drugs in the field can significantly improve efficiencies in processing of related criminal cases. The screening of passengers and luggage at transportation hubs is a critical need for homeland security for which mass spectrometry is well suited to provide definitive answers with low false positive rates. Mass spectrometry can yield reliable data for military personnel testing sites for potential chemical weapons release. To meet the needs of the forensic and security communities fieldable mass spectrometers based on membrane inlet systems and hybrid gas chromatography systems have been developed and commercialized. More recently developed ambient ionization mass spectrometry methods can eliminate the time, equipment, and expertise associated with sample preparation, and so are especially appealing for on-site analysis. We describe the development of fieldable mass spectrometry systems, with emphasis on commercially available systems that have been deployed for on-site analysis of seized drugs, chemical warfare agents, explosives, and other analytes of interest to the forensic and security communities. © 2020 John Wiley & Sons Ltd. Mass Spec Rev.

2.
Anal Chem ; 92(9): 6676-6683, 2020 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-32255335

RESUMO

Forensic laboratory backlogs are replete with suspected drug samples. Shifting analysis toward the point of seizure would save significant time and public funds. Moreover, a two-tiered identification strategy for controlled substance testing that relies on two independent, discerning methods could entirely circumvent the need for forensic laboratory testing. To this end, we coupled Raman spectroscopy and paper spray ionization mass spectrometry (PSI-MS) on a single instrumental platform. Both methods are capable of ambient analysis with fieldable instruments, yet Raman is often limited to bulk analysis. Critical to this work is the development of a gold nanoparticle (AuNP)-embedded paper swab to extend the capability of Raman spectroscopy to trace evidence via surface-enhanced Raman scattering (SERS). Plasmonic papers are characterized with respect to SERS signals and compatibility with PSI-MS analysis. Proof-of-principle is established with the identification of five representative drugs, and detection limits on the scale of 1-100 ng are achieved for both PSI-MS and SERS. The integrated SERS-PSI-MS system achieved 99.8% accurate chemical identification in a blind study consisting of 500 samples. Additionally, we demonstrate facile discrimination of several JWH-018 isomers via SERS even when MS and MS2 spectra are indistinguishable. Successful coupling of SERS and PSI-MS to enable on-site chemical analysis by two independent methods can potentially lead to a desirable paradigm shift in the handling of drug evidence.

3.
J Am Soc Mass Spectrom ; 31(2): 336-346, 2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-32031391

RESUMO

The complexity of field-borne sample matrices and the instrumental constraints of portable mass spectrometers (MS) often necessitate that preparative steps are added prior to ambient MS methods when operated on-site, but the corresponding decrease in throughput and experimental simplicity can make field operation impractical. To this end, we report a modified ambient MS method, filter cone spray ionization (FCSI), specifically designed for simple, yet robust, processing of bulk forensic evidence and environmental samples using a fieldable MS system. This paper-crafted source utilizes low-cost laboratory consumables to produce a conical structure that serves as a disposable, spray-based ionization source. Integrated extraction and filtration capabilities mitigate sample heterogeneity and carryover concerns and expedite sample processing, as characterized through the analysis of a variety of authentic forensic evidence types (e.g., abused pharma tablets, counterfeit/adulterated tablets, crystal-based drugs, synthetic marijuana, toxicological specimens) and contaminated soil samples. The data presented herein suggests that the FCSI-MS design could prove robust to the rigors of field-borne, bulk sample screening, overcoming the inefficiencies of other ambient MS methods for these sample classes. Novel applications of FCSI-MS are also examined, such as the coupling to trace evidence vacuum filtration media.

4.
J Am Soc Mass Spectrom ; 30(11): 2289-2296, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31502222

RESUMO

Only a few analytical techniques are available for the characterization of mechanochemical synthetic reaction products. We demonstrate here that DESI-MS is a powerful technique for this purpose, combining the selectivity of MS-based assays with the simplicity and in situ analysis capability of ambient ionization methods. In this work, we report that auranofin, a gold-based drug, and its precursor triethylphosphine gold(I) chloride undergo a complex array of ligand exchange/scrambling reactions with thiol-containing amino acids in the solid state. The products were readily characterized by DESI-MS analysis from the solid-phase reaction, clearly exhibiting ligand exchange and scrambling, with independent confirmation by solid state 13C-NMR. The thioglucose and triethylphosphine moieties exchanged with cysteine and its derivatives, whereas the glutathione replaced 2,3,4,6-tetra-o-acetyl-ß-1-D-glucopyranose only. It was concluded that ligand exchange and scrambling reactions can be carried out in the solid state, and some of the unique products reported in this study can be conveniently prepared through mechanochemical synthesis in good yields (> 98%), as demonstrated by synthesis of (L-cysteinato-S)-triethylphosphine gold(I) from triethylphosphine gold(I) chloride and L-cysteine.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA