Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(7)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37050544

RESUMO

BACKGROUND: cervical spinal cord injury leads to loss of upper limb functionality, which causes a decrease in autonomy to perform activities of daily living. The use of robotic technologies in rehabilitation could contribute to improving upper limb functionality and treatment quality. This case report aims to describe the potential of robotic hand treatment with Gloreha Sinfonia, in combination with conventional rehabilitation, in a tetraparetic patient. MATERIAL: fifteen rehabilitative sessions were performed. Evaluations were conducted pre-treatment (T0), post-treatment (T1), and at two-months follow-up (T2) based on: the upper-limb range of motion and force assessment, the FMA-UE, the 9-Hole Peg Test (9HPT), and the DASH questionnaire. A virtual reality game-based rating system was used to evaluate the force control and modulation ability. RESULTS: the patient reported greater ability to use hands with less compensation at T1 and T2 assessments. Improvements in clinical scales were reported in both hands at T1, however, at T2 only did the dominant hand show further improvement. Improved grip strength control and modulation ability were reported for T1. However a worsening was found in both hands at T2, significant only for the non-dominant hand. The maximum force exerted increased from T0 to T2 in both hands. CONCLUSION: hand treatment combining physical therapy and Gloreha Sinfonia seems to have benefits in functionality and dexterity in tetraparetic patient in the short term. Further studies are needed to confirm these findings, to verify long-term results, and to identify the most appropriate modalities of robotic rehabilitation.


Assuntos
Paresia , Robótica , Humanos , Atividades Cotidianas , Mãos , Força da Mão , Modalidades de Fisioterapia , Recuperação de Função Fisiológica , Resultado do Tratamento , Extremidade Superior , Robótica/métodos , Paresia/reabilitação
2.
Sensors (Basel) ; 22(17)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36081165

RESUMO

Quantitatively assessing personal health status is gaining increasing attention due to the improvement of diagnostic technology and the increasing occurrence of chronic pathologies. Monitoring physiological parameters allows for retrieving a general overview of the personal health status. Respiratory activity can provide relevant information, especially when pathologies affect the muscles and organs involved in breathing. Among many technologies, wearables may represent a valid solution for continuous and remote monitoring of respiratory activity, thus reducing healthcare costs. The most popular wearables used in this arena are based on detecting the breathing-induced movement of the chest wall. Therefore, their use in patients with impaired chest wall motion and abnormal respiratory kinematics can be challenging, but literature is still in its infancy. This study investigates the performance of a custom wearable device for respiratory monitoring in post-stroke patients. We tested the device on six hemiplegic patients under different respiratory regimes. The estimated respiratory parameters (i.e., respiratory frequency and the timing of the respiratory phase) demonstrated good agreement with the ones provided by a gold standard device. The promising results of this pilot study encourage the exploitation of wearables on these patients that may strongly impact the treatment of chronic diseases, such as hemiplegia.


Assuntos
Acidente Vascular Cerebral , Dispositivos Eletrônicos Vestíveis , Hemiplegia , Humanos , Projetos Piloto , Taxa Respiratória
3.
Sensors (Basel) ; 22(4)2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35214287

RESUMO

In this study, a novel wearable system for the identification of compensatory trunk movements (CTMs) in post-stroke hemiplegic patients is presented. The device is composed of seven soft sensing elements (SSEs) based on fiber Bragg grating (FBG) technology. Each SSE consists of a single FBG encapsulated into a flexible matrix to enhance the sensor's robustness and improve its compliance with the human body. The FBG's small size, light weight, multiplexing capability, and biocompatibility make the proposed wearable system suitable for multi-point measurements without any movement restriction. Firstly, its manufacturing process is presented, together with the SSEs' mechanical characterization to strain. Results of the metrological characterization showed a linear response of each SSE in the operating range. Then, the feasibility assessment of the proposed system is described. In particular, the device's capability of detecting CTMs was assessed on 10 healthy volunteers and eight hemiplegic patients while performing three tasks which are representative of typical everyday life actions. The wearable system showed good potential in detecting CTMs. This promising result may foster the use of the proposed device on post-stroke patients, aiming at assessing the proper course of the rehabilitation process both in clinical and domestic settings. Moreover, its use may aid in defining tailored strategies to improve post-stoke patients' motor recovery and quality of life.


Assuntos
Qualidade de Vida , Dispositivos Eletrônicos Vestíveis , Hemiplegia , Humanos , Movimento/fisiologia , Tronco/fisiologia
4.
Sensors (Basel) ; 21(19)2021 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-34640930

RESUMO

Inappropriate posture and the presence of spinal disorders require specific monitoring systems. In clinical settings, posture evaluation is commonly performed with visual observation, electrogoniometers or motion capture systems (MoCaps). Developing a measurement system that can be easily used also in non-structured environments would be highly beneficial for accurate posture monitoring. This work proposes a system based on three magneto-inertial measurement units (MIMU), placed on the backs of seventeen volunteers on the T3, T12 and S1 vertebrae. The reference system used for validation is a stereophotogrammetric motion capture system. The volunteers performed forward bending and sit-to-stand tests. The measured variables for identifying the posture were the kyphosis and the lordosis angles, as well as the range of movement (ROM) of the body segments. The comparison between MIMU and MoCap provided a maximum RMSE of 5.6° for the kyphosis and the lordosis angles. The average lumbo-pelvic contribution during forward bending (41.8 ± 8.6%) and the average lumbar ROM during sit-to-stand (31.8 ± 9.8° for sitting down, 29.6 ± 7.6° for standing up) obtained with the MIMU system agree with the literature. In conclusion, the MIMU system, which is wearable, inexpensive and easy to set up in non-structured environments, has been demonstrated to be effective in posture evaluation.


Assuntos
Movimento , Postura , Fenômenos Biomecânicos , Humanos , Pelve , Postura Sentada
5.
Sensors (Basel) ; 21(14)2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34300534

RESUMO

The detection of gait abnormalities is essential for professionals involved in the rehabilitation of walking disorders. Instrumented treadmills are spreading as an alternative to overground gait analysis. To date, the use of these instruments for recording kinematic gait parameters is still limited in clinical practice due to the lack of validation studies. This study aims to investigate the performance of a multi-sensor instrumented treadmill (i.e., WalkerViewTM, WV) for performing gait analysis. Seventeen participants performed a single gait test on the WV at three different speeds (i.e., 3 km/h, 5 km/h, and 6.6 km/h). In each trial, spatiotemporal and kinematic parameters were recorded simultaneously by the WV and by a motion capture system used as the reference. Intraclass correlation coefficient (ICC) of spatiotemporal parameters showed fair to excellent agreement at the three walking speeds for steps time, cadence, and step length (range 0.502-0.996); weaker levels of agreement were found for stance and swing time at all the tested walking speeds. Bland-Altman analysis of spatiotemporal parameters showed a mean of difference (MOD) maximum value of 0.04 s for swing/stance time and WV underestimation of 2.16 cm for step length. As for kinematic variables, ICC showed fair to excellent agreement (ICC > 0.5) for total range of motion (ROM) of hip at 3 km/h (range 0.579-0.735); weaker levels of ICC were found at 5 km/h and 6.6 km/h (range 0.219-0.447). ICC values of total knee ROM showed poor levels of agreement at all the tested walking speeds. Bland-Altman analysis of hip ROM revealed a higher MOD value at higher speeds up to 3.91°; the MOD values of the knee ROM were always higher than 7.67° with a 60° mean value of ROM. We demonstrated that the WV is a valid tool for analyzing the spatiotemporal parameters of walking and assessing the hip's total ROM. Knee total ROM and all kinematic peak values should be carefully evaluated, having shown lower levels of agreement.


Assuntos
Marcha , Caminhada , Fenômenos Biomecânicos , Teste de Esforço , Humanos , Amplitude de Movimento Articular , Análise Espaço-Temporal
6.
Sensors (Basel) ; 20(14)2020 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-32659958

RESUMO

Low back pain (LBP) is one of the musculoskeletal disorders that most affects workers. Among others, one of the working categories which mainly experiences such disease are video terminal workers. As it causes exploitation of the National Health Service and absenteeism in workplaces, LBP constitutes a relevant socio-economic burden. In such a scenario, a prompt detection of wrong seating postures can be useful to prevent the occurrence of this disorder. To date, many tools capable of monitoring the spinal range of motions (ROMs) are marketed, but most of them are unusable in working environments due to their bulkiness, discomfort and invasiveness. In the last decades, fiber optic sensors have made their mark allowing the creation of light and compact wearable systems. In this study, a novel wearable device embedding a Fiber Bragg Grating sensor for the detection of lumbar flexion-extensions (F/E) in seated subjects is proposed. At first, the manufacturing process of the sensing element was shown together with its mechanical characterization, that shows linear response to strain with a high correlation coefficient (R2 > 0.99) and a sensitivity value (Sε) of 0.20 nm∙mε-1. Then, the capability of the wearable device in measuring F/E in the sagittal body plane was experimentally assessed on a small population of volunteers, using a Motion Capture system (MoCap) as gold standard showing good ability of the system to match the lumbar F/E trend in time. Additionally, the lumbar ROMs were evaluated in terms of intervertebral lumbar distances (Δ d L 3 - L 1 ) and angles, exhibiting moderate to good agreement with the MoCap outputs (the maximum Mean Absolute Error obtained is ~16% in detecting Δ d L 3 - L 1 ). The proposed wearable device is the first attempt for the development of FBG-based wearable systems for workers' safety monitoring.


Assuntos
Dor Lombar/diagnóstico , Amplitude de Movimento Articular , Coluna Vertebral/fisiologia , Dispositivos Eletrônicos Vestíveis , Humanos , Movimento , Saúde Ocupacional , Postura Sentada
7.
Sensors (Basel) ; 20(2)2020 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-31963696

RESUMO

Musculoskeletal disorders are the most common form of occupational ill-health. Neck pain is one of the most prevalent musculoskeletal disorders experienced by computer workers. Wrong postural habits and non-compliance of the workstation to ergonomics guidelines are the leading causes of neck pain. These factors may also alter respiratory functions. Health and safety interventions can reduce neck pain and, more generally, the symptoms of musculoskeletal disorders and reduce the consequent economic burden. In this work, a multi-parametric wearable system based on two fiber Bragg grating sensors is proposed for monitoring neck movements and breathing activity of computer workers. The sensing elements were positioned on the neck, in the frontal and sagittal planes, to monitor: (i) flexion-extension and axial rotation repetitions, and (ii) respiratory frequency. In this pilot study, five volunteers were enrolled and performed five repetitions of both flexion-extension and axial rotation, and ten breaths of both quite breathing and tachypnea. Results showed the good performances of the proposed system in monitoring the aforementioned parameters when compared to optical reference systems. The wearable system is able to well-match the trend in time of the neck movements (both flexion-extension and axial rotation) and to estimate mean and breath-by-breath respiratory frequency values with percentage errors ≤6.09% and ≤1.90%, during quiet breathing and tachypnea, respectively.


Assuntos
Monitorização Fisiológica/métodos , Pescoço/fisiologia , Taxa Respiratória/fisiologia , Dispositivos Eletrônicos Vestíveis , Adulto , Computadores , Ergonomia , Feminino , Humanos , Masculino , Monitorização Fisiológica/instrumentação , Projetos Piloto , Processamento de Sinais Assistido por Computador , Adulto Jovem
8.
Respiration ; 93(5): 339-354, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28329750

RESUMO

BACKGROUND: Optoelectronic plethysmography (OEP) is a non-invasive motion capture method to measure chest wall movements and estimate lung volumes. OBJECTIVES: To provide an overview of the clinical findings and research applications of OEP in the assessment of breathing mechanics across populations of healthy and diseased individuals. METHODS: A bibliographic research was performed with the terms "opto-electronic plethysmography," "optoelectronic plethysmography," and "optoelectronic plethysmograph" in 50 digital library and bibliographic search databases resulting in the selection of 170 studies. RESULTS: OEP has been extensively employed in studies looking at chest wall kinematics and volume changes in chest wall compartments in healthy subjects in relation to age, gender, weight, posture, and different physiological conditions. In infants, OEP has been demonstrated to be a tool to assess disease severity and the response to pharmacological interventions. In chronic obstructive pulmonary disease patients, OEP has been used to test if patients can dynamically hyperinflate or deflate their lungs during exercise. In neuromuscular patients, respiratory muscle strength and chest kinematics have been analyzed. A widespread application of OEP is in tailoring post-operative pulmonary rehabilitation as well as in monitoring volume increases and muscle contributions during exercise. CONCLUSIONS: OEP is an accurate and validated method of measuring lung volumes and chest wall movements. OEP is an appropriate alternative method to monitor and analyze respiratory patterns in children, adults, and patients with respiratory diseases. OEP may be used in the future to contribute to improvements in the therapeutic strategies for respiratory conditions.


Assuntos
Medidas de Volume Pulmonar/métodos , Pletismografia de Impedância , Exercício Físico , Humanos , Avaliação de Resultados em Cuidados de Saúde , Doença Pulmonar Obstrutiva Crônica/diagnóstico
9.
Neural Plast ; 2017: 7876507, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29375915

RESUMO

The efficacy of standard rehabilitative therapy for improving upper limb functions after stroke is limited; thus, alternative strategies are needed. Vagus nerve stimulation (VNS) paired with rehabilitation is a promising approach, but the invasiveness of this technique limits its clinical application. Recently, a noninvasive method to stimulate vagus nerve has been developed. The aim of the present study was to explore whether noninvasive VNS combined with robotic rehabilitation can enhance upper limb functionality in chronic stroke. Safety and efficacy of this combination have been assessed within a proof-of-principle, double-blind, semirandomized, sham-controlled trial. Fourteen patients with either ischemic or haemorrhagic chronic stroke were randomized to robot-assisted therapy associated with real or sham VNS, delivered for 10 working days. Efficacy was evaluated by change in upper extremity Fugl-Meyer score. After intervention, there were no adverse events and Fugl-Meyer scores were significantly better in the real group compared to the sham group. Our pilot study confirms that VNS is feasible in stroke patients and can produce a slight clinical improvement in association to robotic rehabilitation. Compared to traditional stimulation, noninvasive VNS seems to be safer and more tolerable. Further studies are needed to confirm the efficacy of this innovative approach.


Assuntos
Reabilitação do Acidente Vascular Cerebral/métodos , Estimulação Elétrica Nervosa Transcutânea/métodos , Extremidade Superior/fisiopatologia , Estimulação do Nervo Vago/métodos , Adulto , Idoso , Pressão Sanguínea , Método Duplo-Cego , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Robótica , Resultado do Tratamento
10.
J Funct Morphol Kinesiol ; 9(1)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38535417

RESUMO

During the second wave of the COVID-19 pandemic, a young adult presented symptoms that were reported at first evaluation to be a frozen shoulder (adhesive capsulitis). The patient's history, clinical manifestations related to the onset of pain, unilateral weakness, and physical examination led to a physiotherapy referral. Subsequent instrumental investigations showed an idiopathic brachial neuritis known as Parsonage-Turner Syndrome (PTS). Contrary to recent descriptions in the literature, the patient did not experience PTS either after COVID-19 vaccination or after COVID-19 virus infection. The proposed multimodal treatment, considering the patient's characteristics, led to a recovery of muscle strength and function of the upper limb, observed even three years after the acute event. The frequency of rehabilitation treatment, the choice of exercises, the dosage, and the methods of execution require further studies in order to define an evidence-based treatment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA