Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 26(1): 100006, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38215698

RESUMO

This position statement guides cardiovascular magnetic resonance (CMR) imaging program directors and learners on the key competencies required for Level II and III CMR practitioners, whether trainees come from a radiology or cardiology background. This document is built upon existing curricula and was created and vetted by an international panel of cardiologists and radiologists on behalf of the Society for Cardiovascular Magnetic Resonance (SCMR).


Assuntos
Cardiologia , Competência Clínica , Consenso , Currículo , Educação de Pós-Graduação em Medicina , Imageamento por Ressonância Magnética , Humanos , Educação de Pós-Graduação em Medicina/normas , Imageamento por Ressonância Magnética/normas , Cardiologia/educação , Cardiologia/normas , Doenças Cardiovasculares/diagnóstico por imagem , Cardiologistas/educação , Cardiologistas/normas , Valor Preditivo dos Testes , Radiologistas/educação , Radiologistas/normas , Radiologia/educação , Radiologia/normas , Sociedades Médicas/normas
2.
J Cardiovasc Magn Reson ; 26(1): 100995, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38219955

RESUMO

Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs.


Assuntos
Consenso , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Valor Preditivo dos Testes , Humanos , Fatores de Risco , Medição de Risco , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética/efeitos adversos , Tomada de Decisão Clínica , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia
3.
AJR Am J Roentgenol ; 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37753860

RESUMO

Myocardial fibrosis (MF) is defined as excessive production and deposition of extracellular matrix (ECM) proteins, resulting in pathologic myocardial remodeling. Three types of MF have been identified: replacement fibrosis from tissue necrosis, reactive fibrosis from myocardial stress, and infiltrative interstitial fibrosis from progressive deposition of non-degradable material such as amyloid. While echocardiography, nuclear medicine, and CT play important roles in the assessment of MF, MRI is pivotal in the evaluation of MF, using the late gadolinium enhancement (LGE) technique as a primary endpoint. The LGE technique focuses on the pattern and distribution of gadolinium accumulation in the myocardium and assists the diagnosis and establishment of the etiology of both ischemic and non-ischemic cardiomyopathy. LGE MRI aids prognostication and risk stratification. In addition, LGE MRI is used to guide management of patients being considered for ablation for arrhythmias. Parametric mapping techniques, including T1 mapping and extracellular volume measurement, allow detection and quantification of diffuse fibrosis, which may not be detected by LGE MRI. These techniques also allow monitoring of disease progression and therapy response. This review provides an update on imaging of MF, including prognostication and risk stratification tools, electrophysiologic considerations, and disease monitoring.

4.
AJR Am J Roentgenol ; 218(3): 396-404, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34612678

RESUMO

Pulmonary CTA is a ubiquitous study interpreted by radiologists with different levels of experience in a variety of practice settings. Pulmonary embolism (PE) can range from an incidental and clinically insignificant finding to a clinically significant thrombus that can be managed on an outpatient basis to a potentially fatal condition requiring immediate medical or invasive management. Accordingly, a clear and concise pulmonary CTA report should effectively communicate the most pertinent findings to help the treating medical team diagnose or exclude PE and provide information to guide appropriate management. In this Expert Panel Narrative Review, we discuss the purpose of the radiology report for pulmonary CTA, the optimal report format, and the relevant findings that need to be addressed and their clinical significance.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Artéria Pulmonar/diagnóstico por imagem
5.
Radiographics ; 41(7): 1897-1915, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34652974

RESUMO

Spontaneous coronary artery dissection (SCAD) is a nonatherosclerotic cause of myocardial infarction in young and middle-aged women that has gained increasing awareness in recent years. Its diagnosis presents a challenge. Invasive coronary angiography is the primary imaging modality for diagnosing SCAD; however, it carries risk in these patients, who have an increased predisposition to complications. Advances in CT technology enable robust noninvasive evaluation of the coronary arteries at low radiation doses and have been increasingly utilized for the diagnosis or resolution of SCAD, in hemodynamically stable patients or when diagnosis of SCAD is uncertain at invasive angiography, particularly in proximal vessels. However, criteria for the diagnosis of SCAD with use of coronary CT angiography (CCTA) have not been currently established, and sensitivity and specificity for diagnosis have not yet been defined. The appearance of SCAD at CCTA can be subtle and can be missed, especially in distal small-caliber coronary arteries; hence utilization of other noninvasive imaging multimodalities may help solve this diagnostic challenge. Accurate and prompt diagnosis is vital, as management of SCAD differs significantly from that of traditional atherosclerotic acute coronary syndromes, with conservative management preferred for the majority of SCAD patients, and invasive treatment reserved for those with ongoing or recurrent ischemia, heart failure, or hemodynamic compromise. The goal of this review is twofold: (a) to discuss the potential role of CCTA in the diagnosis of SCAD, and (b) to discuss the role of multimodality imaging that may improve diagnostic yield, guide management, and enable subsequent surveillance. An invited commentary by Ordovas is available online. Online supplemental material is available for this article. ©RSNA, 2021.


Assuntos
Anomalias dos Vasos Coronários , Doenças Vasculares , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Dissecação , Feminino , Humanos , Pessoa de Meia-Idade , Fatores de Risco , Doenças Vasculares/diagnóstico por imagem
6.
Radiographics ; 41(4): E126-E137, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34143712

RESUMO

The number of implanted devices such as orthopedic hardware and cardiac implantable devices continues to increase with an increase in the age of the patient population, as well as an increase in the number of indications for specific devices. Many patients with these devices have or will develop clinical conditions that are best depicted at MRI. However, implanted devices containing paramagnetic or ferromagnetic substances can cause significant artifact, which could limit the diagnostic capability of this modality. Performing imaging with MRI when an implant is present may be challenging, and there are numerous techniques the radiologist and technologist can use to help minimize artifacts related to implants. First, knowledge of the presence of an implant before patient arrival is critical to ensure safety of the patient when the device is subjected to a strong magnetic field. Once safety is ensured, the examination should be performed with the MRI system that is expected to provide the best image quality. The selection of the MRI system includes multiple considerations such as the effects of field strength and availability of specific sequences, which can reduce metal artifact. Appropriate patient positioning, attention to MRI parameters (including bandwidth, voxel size, and echo), and appropriate selection of sequences (those with less metal artifact and advanced metal reduction sequences) are critical to improve image quality. Patients with implants can be successfully imaged with MRI with appropriate planning and understanding of how to minimize artifacts. This improves image quality and the diagnostic confidence of the radiologist. ©RSNA, 2021.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Próteses e Implantes , Humanos , Metais
7.
AJR Am J Roentgenol ; 214(3): 546-556, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31967503

RESUMO

OBJECTIVE. A spectrum of pathophysiologic mechanisms can lead to the development of myocardial disorders including ischemia, genetic abnormalities, and systemic disorders. Cardiac MRI identifies different myocardial disorders, provides prognostic information, and directs therapy. In comparison with other imaging modalities, cardiac MRI has the advantage of allowing both functional assessment and tissues characterization in a single examination without the use of ionizing radiation. Newer cardiac MRI techniques including mapping can provide additional information about myocardial disease that may not be detected using conventional techniques. Emerging techniques including MR spectroscopy and finger printing will likely change the way we understand the pathophysiology mechanisms of the wide array of myocardial disorders. CONCLUSION. Imaging of myocardial disorders encompasses a large variety of conditions including both ischemic and nonischemic diseases. Cardiac MRI sequences, such as balanced steady-state free precession and late gadolinium enhancement, play a critical role in establishing diagnosis, determining prognosis, and guiding therapeutic management. Additional sequences-including perfusion imaging, T2*, real-time cine, and T2-weighted sequences-should be performed in specific clinical scenarios. There is emerging evidence for the use of mapping in imaging of myocardial disease. Multiple other new techniques are currently being studied. These novel techniques will likely change the way myocardial disorders are understood and diagnosed in the near future.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cardiomiopatias/fisiopatologia , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Prognóstico
8.
AJR Am J Roentgenol ; 215(2): 374-381, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32374663

RESUMO

OBJECTIVE. Patients with cardiac implantable electronic devices (CIEDs) require cardiac MRI (CMRI) for a variety of reasons. The purpose of this study is to review and evaluate the value and safety of CMRI for patients with in situ CIEDs. CONCLUSION. Late gadolinium enhancement CMRI is the reference standard for assessing myocardial viability in patients with ventricular tachycardia before ablation of arrhythmogenic substrates. The use of late gadolinium enhancement CMRI for patients with CIEDs is safe as long as an imaging protocol is in place and precaution measures are taken.


Assuntos
Técnicas de Imagem Cardíaca , Meios de Contraste , Desfibriladores Implantáveis , Gadolínio , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/efeitos adversos , Marca-Passo Artificial , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Idoso , Técnicas de Imagem Cardíaca/métodos , Feminino , Humanos
10.
AJR Am J Roentgenol ; 213(3): 555-561, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31120781

RESUMO

OBJECTIVE. An important application of late gadolinium enhancement (LGE) cardiac MRI is accurate assessment of myocardial scar before ablation. However, this is often limited in patients with cardiac implantable electronic devices (CIEDs) because of metal device-induced artifacts. The purpose of this study was to determine whether a modified wideband inversion recovery (IR) LGE MRI technique decreases artifact volume to allow the assessment of myocardial scar. SUBJECTS AND METHODS. Fifty patients (17 women and 33 men; mean age ± SD, 61 ± 12 years; mean ejection fraction ± SD, 35.9% ± 13.3%) with CIEDs underwent cardiac MRI using conventional and modified wideband IR LGE techniques before ablation. The volume of device-induced artifact was quantified and stratified by tertiles on mild, moderate, and severe. Ordinal logistic regression analysis assessed the association between artifact volume on conventional and wideband images adjusted for patients' demographics. RESULTS. Conventional LGE MRI resulted in device-induced hyperintense artifacts that obscured ventricular segments in 32 of 50 (64%) cases. Wideband LGE MRI significantly reduced severe artifact volume (p < 0.0001) and completely resolved all mild and most moderate artifacts. Overall, wideband techniques resulted in a 56% reduction in total artifact volume for the cohort (p < 0.0001). The wideband LGE MRI sequence minimized artifacts in the most commonly obscured segments on the conventional LGE MRI sequence, with persistent artifacts in seven, eight, and four of 32 cases at the basal anterior, midventricular anterior, and midventricular anteroseptal segments, respectively. CONCLUSION. The modified wideband IR technique completely resolves mild and moderate device-induced hyperintense artifacts and significantly reduces the volume of severe artifact to allow accurate identification of myocardial scar in patients with CIEDs before ablation.


Assuntos
Artefatos , Cicatriz/diagnóstico por imagem , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Marca-Passo Artificial , Meios de Contraste , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Prospectivos
13.
AJR Am J Roentgenol ; 208(3): W60-W70, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27959579

RESUMO

OBJECTIVE: The purpose of this article is to describe the importance of clinical decision rules for pretest assessment of the probability of the presence of pulmonary embolism (PE), the effect of use of the rules on the yield of pulmonary CT angiography, and obstacles to implementation of the rules in clinical practice. CONCLUSION: Pulmonary CT angiography is the imaging modality of choice for evaluating patients with suspected PE. Despite increased use of pulmonary CTA, the diagnostic yield for PE remains low. Study results suggest a potential benefit to the use of clinical decision tools in the diagnostic workup of suspected PE.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Sistemas de Apoio a Decisões Clínicas/organização & administração , Embolia Pulmonar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Medicina Baseada em Evidências , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Europace ; 19(5): 812-817, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27256419

RESUMO

AIMS: Magnetic resonance imaging (MRI) has been reported to be safe in patients with cardiac implantable electronic devices (CIED) provided a specific protocol is followed. The objective of this study was to assess whether this is also true for patients excluded from published protocols. METHODS AND RESULTS: A total of 160 MRIs were obtained in 142 consecutive patients with CIEDs [106 patients had an implantable cardioverter defibrillator (ICD) and 36 had a pacemaker implanted] using an adapted, pre-specified protocol. A cardiac MRI was performed in 95 patients, and a spinal/brain MRI was performed in 47 patients. Forty-six patients (32%) had either abandoned leads (n = 10), and/or were pacemaker dependent with an implanted ICD (n = 19), had recently implanted CIEDs (n = 1), and/or had a CIED device with battery depletion (n = 2), and/or a component of the CIED was recalled or on advisory (n = 32). No major complications occurred. Some device parameters changed slightly, but significantly, right after or at 1-week post-MRI without requiring any reprogramming. In one patient with an ICD on advisory, the pacing rate changed inexplicably during one of his two MRIs from 90 to 50 b.p.m. CONCLUSION: Using a pre-specified protocol, cardiac and non-cardiac MRIs were performed in CIED patients with pacemaker dependency, abandoned leads, or depleted batteries without occurrence of major adverse events. Patients with devices on advisory need to be monitored carefully during MRI, especially if they are pacemaker dependent.


Assuntos
Queimaduras por Corrente Elétrica/etiologia , Contraindicações , Desfibriladores Implantáveis/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Reação a Corpo Estranho/etiologia , Imageamento por Ressonância Magnética/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Queimaduras por Corrente Elétrica/prevenção & controle , Feminino , Reação a Corpo Estranho/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Radiology ; 300(1): 197-198, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33908797
17.
J Nucl Cardiol ; 23(5): 960-969, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27146882

RESUMO

BACKGROUND: In type I diabetes (T1DM), alterations in LV function may occur due to changes in innervation, metabolism, and efficiency. OBJECTIVES: We evaluated the association between sympathetic nerve function, oxidative metabolism, resting blood flow, LV efficiency and function in healthy diabetics, and assessed gender differences. METHODS: Cross-sectional study of 45 subjects with T1DM, 60% females, age 34 ± 13 years, and 10 age-matched controls. Positron emission tomography (PET) imaging with [(11)C]acetate and [(11)C]meta-hydroxyephedrine was performed, in addition to cardiac magnetic resonance imaging. RESULTS: There were no significant differences in LV function, innervation, or oxidative metabolism between T1DM and controls. Cardiac oxidative metabolism was positively associated with higher levels of sympathetic activation, particularly in women. Diabetic women had significantly lower efficiency compared with diabetic men. Resting flow was significantly higher in diabetic women compared with diabetic men, and tended to be higher in female controls as well. CONCLUSIONS: Measures of myocardial function, metabolism, blood flow, and sympathetic activation were preserved in young, otherwise healthy, T1DM patients. However, T1DM women presented with greater myocardial oxidative metabolism requirements than men. Ongoing studies are evaluating changes over time.


Assuntos
Diabetes Mellitus Tipo 1/fisiopatologia , Cardiomiopatias Diabéticas/fisiopatologia , Efedrina/farmacocinética , Ventrículos do Coração/fisiopatologia , Volume Sistólico , Sistema Nervoso Simpático/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Cardiomiopatias Diabéticas/diagnóstico por imagem , Cardiomiopatias Diabéticas/etiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Caracteres Sexuais , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
19.
Eur Radiol ; 25(8): 2298-309, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25764090

RESUMO

OBJECTIVE: To determine whether intrathoracic fat volumes are associated with presence and chronicity of atrial fibrillation (AF) and radiofrequency ablation (RFA) treatment outcome. METHODS: IRB approval was obtained and patient consent was waived for this HIPAA-compliant retrospective study. 169 patients with AF (75 non-paroxysmal and 94 paroxysmal) and 62 control patients underwent cardiac CT examination. Extrapericardial (EPFV) and epicardial fat volumes (EFV) were measured on CT, the sum of which is the total intrathoracic fat volume. Associations between these three fat volumes and presence and chronicity of AF, and outcome after RFA, were evaluated using logistic regression analysis. RESULTS: EFV was significantly associated with presence [OR 1.01 (95 % CI 1.003-1.03), p = 0.01], chronicity of AF [1.008 (1.001-1.020), p = 0.03] and AF recurrence after RFA [1.009 (1.001-1.01), p = 0.02] after adjustment for age, gender and BMI. Patients with a larger EFV had a shorter time to AF recurrence (p = 0.017) and a higher rate of recurrence (54 % vs 46 %) (p = 0.002) after RFA. EPFV had no significant associations. CONCLUSION: Increased epicardial fat is associated with the presence and chronicity of AF, a higher probability of AF recurrence after RFA and a shorter AF-free interval. KEY POINTS: • Increased epicardial fat is associated with presence and chronicity of atrial fibrillation • Extensive epicardial fat is associated with earlier recurrences of AF after ablation • Extensive epicardial fat may reduce transmurality of ablation by affecting current dynamics.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/fisiopatologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Pericárdio/diagnóstico por imagem , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Recidiva , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA