Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 32(3): 1833-1842, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34668994

RESUMO

OBJECTIVES: To compare the diagnostic value of ultrashort echo time (UTE) magnetic resonance imaging (MRI) for the lung versus the gold standard computed tomography (CT) and two T1-weighted MRI sequences in children. METHODS: Twenty-three patients with proven oncologic disease (14 male, 9 female; mean age 9.0 + / - 5.4 years) received 35 low-dose CT and MRI examinations of the lung. The MRI protocol (1.5-T) included the following post-contrast sequences: two-dimensional (2D) incoherent gradient echo (GRE; acquisition with breath-hold), 3D volume interpolated GRE (breath-hold), and 3D high-resolution radial UTE sequences (performed during free-breathing). Images were evaluated by considering image quality as well as distinct diagnosis of pulmonary nodules and parenchymal areal opacities with consideration of sizes and characterisations. RESULTS: The UTE technique showed significantly higher overall image quality, better sharpness, and fewer artefacts than both other sequences. On CT, 110 pulmonary nodules with a mean diameter of 4.9 + / - 2.9 mm were detected. UTE imaging resulted in a significantly higher detection rate compared to both other sequences (p < 0.01): 76.4% (84 of 110 nodules) for UTE versus 60.9% (67 of 110) for incoherent GRE and 62.7% (69 of 110) for volume interpolated GRE sequences. The detection of parenchymal areal opacities by the UTE technique was also significantly higher with a rate of 93.3% (42 of 45 opacities) versus 77.8% (35 of 45) for 2D GRE and 80.0% (36 of 45) for 3D GRE sequences (p < 0.05). CONCLUSION: The UTE technique for lung MRI is favourable in children with generally high diagnostic performance compared to standard T1-weighted sequences as well as CT. Key Points • Due to the possible acquisition during free-breathing of the patients, the UTE MRI sequence for the lung is favourable in children. • The UTE technique reaches higher overall image quality, better sharpness, and lower artefacts, but not higher contrast compared to standard post-contrast T1-weighted sequences. • In comparison to the gold standard chest CT, the detection rate of small pulmonary nodules small nodules ≤ 4 mm and subtle parenchymal areal opacities is higher with the UTE imaging than standard T1-weighted sequences.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Adolescente , Suspensão da Respiração , Criança , Pré-Escolar , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Tomografia Computadorizada por Raios X
2.
Infection ; 50(5): 1111-1120, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35182354

RESUMO

PURPOSE: Duodenal involvement in COVID-19 is poorly studied. Aim was to describe clinical and histopathological characteristics of critically ill COVID-19 patients suffering from severe duodenitis that causes a significant bleeding and/or gastrointestinal dysmotility. METHODS: In 51 critically ill patients suffering from SARS-CoV-2 pneumonia, severe upper intestinal bleeding and/or gastric feeding intolerance were indications for upper gastrointestinal endoscopy. Duodenitis was diagnosed according to macroscopic signs and mucosal biopsies. Immunohistochemistry was performed to detect viral specific protein and ACE2. In situ hybridization was applied to confirm viral replication. RESULTS: Nine of 51 critically ill patients (18%) suffering from SARS-CoV-2 pneumonia had developed upper GI bleeding complications and/or high gastric reflux. Five of them presented with minor and four (44%) with severe duodenitis. In two patients, erosions had caused severe gastrointestinal bleeding requiring PRBC transfusions. Immunohistochemical staining for SARS-CoV-2 spike protein was positive inside duodenal enterocytes in three of four patients suffering from severe duodenitis. Viral replication could be confirmed by in situ hybridization. CONCLUSION: Our data suggest that about 8% of critically ill COVID-19 patients may develop a severe duodenitis presumably associated with a direct infection of the duodenal enterocytes by SARS-CoV-2. Clinical consequences from severe bleeding and/or upper gastrointestinal dysmotility seem to be underestimated.


Assuntos
COVID-19 , Duodenite , Enzima de Conversão de Angiotensina 2 , COVID-19/complicações , Estado Terminal , Humanos , Recém-Nascido , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Tropismo
3.
Radiologe ; 62(2): 140-148, 2022 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-35041027

RESUMO

CLINICAL ISSUE: Chest X­ray is the most commonly performed X­ray examination in children and adolescents. The aim of this review is to present the benefit of this radiologic modality, but also its limitations. METHODS: Compared with older children, most X­ray examinations of the chest were performed in newborns. After the neonatal period, this review focusses on the diagnosis of inflammatory pulmonary changes, foreign body aspiration, detection of pulmonary nodules, and cystic fibrosis. METHODOLOGICAL INNOVATIONS: The radiation exposure of X­ray examinations is continuously decreasing due to technical innovations. However, other imaging modalities were also continuously being optimized; therefore, alternatives without radiation exposure, i.e., magnetic resonance imaging [MRI] and ultrasound, should be considered in case of specific clinical indications. PRACTICAL RECOMMENDATION: Even if the diagnostic performance of chest X­ray examinations is often minor compared to computed tomography or MRI, chest X­ray still has a high value in children and adolescents, due to its ubiquitous availability and the relatively simple acquisition.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Adolescente , Criança , Humanos , Recém-Nascido , Radiografia , Ultrassonografia , Raios X
4.
J Vasc Interv Radiol ; 31(12): 2132-2140.e5, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33160828

RESUMO

PURPOSE: To evaluate feasibility, embolization success, biodegradability, reperfusion, and biocompatibility of biodegradable microspheres (MS) made from polydioxanone (PDO) for transcatheter arterial embolization. MATERIALS AND METHODS: Unilateral selective renal embolization of a segmental artery was performed in 16 New Zealand White rabbits with PDO-MS (100-150 µm and 90-315 µm). Animals were randomly assigned to different observation periods and underwent control digital subtraction angiography (DSA) and MR imaging immediately (n = 3), 1 week (n = 2), 4 weeks (n = 2), 8 weeks (n = 2), 12 weeks (n = 5), and 16 weeks (n = 2) after embolization. Kidneys were harvested for macroscopic and histologic analysis of embolization success, biodegradability, and biocompatibility. RESULTS: Embolization was technically successful in 15 of 16 animals. One animal died of anesthesia-related circulatory failure. The 100-150 µm MS were injected easily through 3-F catheters; the 90-315 µm MS tended to clog with intermittent catheter obstruction. DSA and MR imaging showed successful target embolization in 13 of 15 animals. In 2 animals, the entire kidney was affected owing to catheter clogging, including a reflux of MS while flushing. Control DSA and MR imaging showed increasing vascular reperfusion with time. Macroscopic and histologic analysis revealed necrosis/infarction in areas in which embolization was achieved. MS were extensively degraded after 16 weeks, and overall inflammatory reaction was mild. CONCLUSIONS: Biodegradable PDO-MS induced effective embolization of target vessels while demonstrating good biocompatibility. MS increasingly dissolved at 16 weeks, partial reperfusion started at week 1, and complete reperfusion started at week 8, thus offering possible advantages as a temporary embolic agent.


Assuntos
Embolização Terapêutica , Rim/patologia , Polidioxanona/administração & dosagem , Artéria Renal , Animais , Estudos de Viabilidade , Injeções Intra-Arteriais , Rim/diagnóstico por imagem , Microesferas , Necrose , Estudo de Prova de Conceito , Coelhos , Artéria Renal/diagnóstico por imagem , Fatores de Tempo
5.
Acta Radiol ; 61(10): 1421-1430, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32122149

RESUMO

BACKGROUND: In computed tomography (CT) scans, artifacts caused by metallic orthopedic implants still hamper the visualization of important, periprosthetic tissues. Smart MAR metal artifact reduction tool is a promising three-stage, projection-based, post-processing algorithm. PURPOSE: To determine whether the Smart MAR tool improves subjective and objective image quality and diagnostic confidence in patients with orthopedic implants of the hip, spine, and shoulder. MATERIAL AND METHODS: Seventy-two patients with orthopedic screws, hip/shoulder replacement, or spine spondylodesis were included. CT scans were performed on a single-source multislice CT scanner, raw data were post-processed using Smart MAR. Image quality was evaluated both quantitatively (ROI-based) and qualitatively (rater-based) and compared to iterative reconstructions (ASIR V). As comparative standard for artificial prosthetic breaks or loosening, follow-up examinations were used. RESULTS: Smart MAR reconstructions of the hip (n = 23), spine (n = 26), and shoulder (n = 23) showed a significantly reduced attenuation and noise of regions adjacent to metallic implants (P<0.002). Subjective image quality (P<0.005, shoulder P = 0.038/P = 0.046) and overall diagnostic confidence were higher in Smart MAR (all regions P<0.002). Signal-to-noise ratio (SNR; P = 0.72/P = 0.96) was not improved. Compared to standard ASIR V new, artificial metal extinctions (up to 50%) or periprosthetic hem lines (48%-73%) were introduced by Smart MAR. CONCLUSION: Smart MAR improved image quality of the hip, spine, and shoulder CT scans resulting in higher diagnostic confidence in evaluation of periprosthetic soft tissues. As shown for spine implants, it should be used with caution and as a complementary tool for evaluation of periprosthetic loosening or integrity of metal implant, as in many cases it introduced new artifacts.


Assuntos
Quadril/diagnóstico por imagem , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Ombro/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Doses de Radiação , Razão Sinal-Ruído
6.
Acta Radiol ; 60(4): 425-432, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29950111

RESUMO

BACKGROUND: Virtual monochromatic images (VMI) generated using spectral computed tomography (CT) are promising recently available tools to improve diagnostic performance in oncologic patients. PURPOSE: To investigate if virtual monochromatic datasets are suitable for clinical routine use in patients with hypervascularized abdominal tumors. MATERIAL AND METHODS: A total of 41 patients with hypervascularized hepatocellular carcinoma (HCC), renal cell carcinoma (RCC), or neuroendocrine tumors (NET) were enrolled in the study; 451 CT series were analyzed. In an intra-individual study design, virtual monochromatic datasets of the arterial phase of each scan were computed. Image quality was assessed objectively by determining signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) and subjectively by using five-point Likert-scales. The volume CT dose index (CTDIvol) was taken from each radiation dose report. The increase in reading time was estimated from the increase in the number of images. RESULTS: Intra-individual comparison of the spectral mode in the arterial phase with the portal venous phase revealed no significant increase in the applied dose. SNR, CNRtumor-to-liver , and CNRtumor-to-muscle were significantly increased by lowering virtual monochromatic energy. Subjective image quality scores revealed an increase of contrast in low energy datasets, resulting in significantly higher diagnostic confidence, but an increased image noise at low energies. While diagnostic confidence improved, taking all datasets into account resulted in a significantly longer estimated reading time. CONCLUSION: In clinical practice, the use of low energy VMI improved diagnostic confidence without a significant increase in dose. The main disadvantage is a decrease in efficiency due to longer reading times.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Neuroendócrino/diagnóstico por imagem , Carcinoma de Células Renais/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias Abdominais/irrigação sanguínea , Idoso , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Neuroendócrino/irrigação sanguínea , Carcinoma de Células Renais/irrigação sanguínea , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Estômago/irrigação sanguínea
7.
Radiol Med ; 124(9): 860-869, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31011996

RESUMO

PURPOSE: To analyze the changes in the work profiles of radiologists and the reporting time after the implementation of professional subspecialization in the radiology department of a Swiss university hospital. METHODS: In a retrospective analysis, the overall number of different radiologic examinations performed in the department of radiology of the largest Swiss university hospital was documented for 2014 and 2016 before and after the implementation of subspecialized reporting (subspecialities: abdominal, musculoskeletal, cardiothoracic, emergency, and pediatric imaging) in May 2015. For six selected radiologists, the number and types of reported examinations as well as the related radiology report turnaround times (RTATs) were analyzed in detail and compared between the two 1-year periods. RESULTS: Overall, there was a significant increase of 10.3% in the total number of examinations performed in the whole department in 2016 compared with 2014. For four of the six radiologists, the range of different types of examinations significantly decreased with the introduction of subspecialized reporting (p < 0.05). Furthermore, there was a significant change in the subset of the ten most commonly reported types of examinations reported by each of the six radiologists. Mean overall RTATs significantly increased for five of the six radiologists (p < 0.05). CONCLUSIONS: Implementation of subspecialized reporting led to a change in the structure and a decrease in the range of different examination types reported by each radiologist. Mean RTAT increased for most radiologists. Subspecialized reporting allows the individual radiologist to focus on a special field of professional competence but can result in longer overall RTAT.


Assuntos
Radiografia/estatística & dados numéricos , Radiografia/normas , Serviço Hospitalar de Radiologia/organização & administração , Radiologia , Especialização , Estudos Retrospectivos , Suíça
8.
Acta Radiol ; 59(11): 1316-1325, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29430936

RESUMO

Background Endovascular aneurysm repair (EVAR) requires lifelong surveillance by computed tomography angiography (CTA). This is attended by a substantial accumulation of radiation exposure. Iterative reconstruction (IR) has been introduced to approach dose reduction. Purpose To evaluate adaptive statistical iterative reconstruction (ASIR) at different levels of tube voltage concerning image quality and dose reduction potential in follow-up post EVAR. Material and Methods One hundred CTAs in 67 patients with EVAR were examined using five protocols: protocol A (n = 40) as biphasic standard using filtered back projection (FBP) at 120 kV; protocols B (n = 40), C (n = 10), and D1 (n = 5) biphasic using ASIR at 120, 100, and 80 kV, respectively; and protocol D2 (n = 5) with a monophasic splitbolus ASIR protocol at 80 kV. Image quality was assessed quantitatively and qualitatively. Applied doses were determined. Results Applied doses in ASIR protocols were significantly lower than FBP standard (up to 75%). Compared to protocol A, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) (e.g. arterial CNR intra-/extra-stent lumen: A = 35.4 ± 13.5, B = 34.2 ± 10.0, C = 29.6 ± 6.8, D1 = 32.1 ± 6.3, D2 = 40.8 ± 23.1) in protocol B were equal and in protocols C and D equal to partially inferior, however not decisive for diagnostic quality. Subjective image quality ratings in all protocols were good to excellent without impairments of diagnostic confidence (A-D2: 5), with high inter-rater agreement (60-100%). Conclusion ASIR contributes to significant dose reduction without decisive impairments of image quality and diagnostic confidence. We recommend an adapted follow-up introducing ASIR and combined low-kV in the long-term surveillance after EVAR.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Procedimentos Endovasculares/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Idoso , Aorta Abdominal/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
9.
Eur Radiol ; 27(1): 149-156, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27085700

RESUMO

OBJECTIVES: The aim of the present study was to histologically compare chondrotoxicity in surgically harvested intervertebral discs (IVDs) of patients following discoblock, discography, or no preoperative intervention. METHODS: Thirty patients (IVD degeneration Modic ≥ 2°, Pfirrmann 3° or 4°) at L4/5 or L5/S1 who were planned for anterior lumbar interbody fusion were randomly assigned to three groups (open MRI: group DG - discography with gadobutrol; group DB - discoblock with bupivacaine at 4 weeks prior to surgery; group C - no intervention). The intervertebral discs were histologically evaluated and compared using ANOVA and Bonferroni tests for cell count, apoptosis, and proliferation. RESULTS: A reduced cell count (groups DG vs. DB vs. C: 14.9 ± 7.1, 9.2 ± 3.8, and 16.6 ± 5.2 cells/mm2, respectively; p ANOVA = 0.016), increased apoptosis (groups DG vs. DB vs. C: 34.9 ± 10.2, 47.4 ± 16.3, 32.6 ± 12.2 %, respectively; p ANOVA = 0.039) and increased cell proliferation (post hoc pDB vs. DG or C p < 0.001; for 3-7 cell monoclonal cell nests: groups DG vs. DB vs. C: 2.4 ± 1, 3.9 ± 1, 2.2 ± 1.1, respectively; p interventionx nest size = 0.006) were found in the IVDs of patients in group DB. CONCLUSIONS: This in vivo study suggests that chondrotoxic effects occur in IVD cells after the intradiscal injection of bupivacaine but not after gadobutrol administration. KEY POINTS: • Local bupivacaine administration to intervertebral discs leads to cell toxicity and proliferation. • Gadobutrol demonstrated no significant effect on cell count, apoptosis, or cell proliferation. • In vivo cytotoxicity was demonstrated histologically in humans for the first time. • Addition/administration of bupivacaine during discographies must be judged critically.


Assuntos
Bupivacaína/administração & dosagem , Degeneração do Disco Intervertebral/cirurgia , Dor Lombar/terapia , Vértebras Lombares/diagnóstico por imagem , Mielografia/métodos , Compostos Organometálicos/administração & dosagem , Fusão Vertebral/métodos , Adulto , Anestésicos Locais/administração & dosagem , Meios de Contraste/administração & dosagem , Feminino , Humanos , Injeções , Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/diagnóstico , Dor Lombar/diagnóstico , Dor Lombar/etiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
10.
J Vasc Interv Radiol ; 28(10): 1378-1385, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28747271

RESUMO

PURPOSE: To evaluate detectability of hepatocellular carcinoma (HCC) using split-bolus cone-beam CT in intraindividual comparison between cone-beam CT and contrast-enhanced MR imaging. MATERIALS AND METHODS: In a retrospective, single-center study, 28 patients with 85 HCC tumors were treated with transarterial chemoembolization between May 2015 and June 2016. All patients underwent arterial and hepatobiliary phase (HBP) MR imaging within 1 month before transarterial chemoembolization. Cone-beam CT images were acquired using a split-bolus contrast injection with 2 contrast injections and 1 cone-beam CT acquisition. Statistical analyses included Friedman 2-way analysis, Kendall coefficient of concordance, and Wilcoxon test. Tumor detectability was scored using a 5-point system (1 = best; 5 = worst) by 2 independent readers resulting in 170 evaluated tumors. Quantitative analysis included signal-to-noise and contrast-to-noise ratio and contrast measurements. P values < .05 were considered significant. RESULTS: Better tumor detection was provided with split-bolus cone-beam CT (2.91/2.73) and HBP MR imaging (2.93/2.21) compared with arterial MR imaging (3.72/3.05; P < .001) without statistical difference between cone-beam CT and HBP MR imaging in terms of detectability (P = .154) and sensitivity for hypervascularized tumors. More tumors were identified on cone-beam CT (n = 121/170) than on arterial MR imaging (n = 94/170). Average contrast-to-noise ratio values of arterial and HBP MR imaging were higher than for cone-beam CT (7.79, 8.58, 4.43), whereas contrast values were higher for cone-beam CT than for MR imaging (0.11, 0.13, 0.97). CONCLUSIONS: Split-bolus cone-beam CT showed excellent detectability of HCC. Sensitivity is comparable to HBP MR imaging and better than arterial phase MR imaging.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico , Meios de Contraste/administração & dosagem , Gadolínio DTPA/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos
11.
J Comput Assist Tomogr ; 41(4): 668-674, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28099226

RESUMO

OBJECTIVE: The aim of the study was to evaluate the impact of iterative reconstruction (IR) and low-kilovolt technique on dose reduction and image quality of chest computed tomography scans obtained in patients with cystic fibrosis (CF). METHODS: A total of 124 CF patients were examined; group A (n = 63) was examined with a dose reduction protocol using IR and group B (n = 61) with a standard protocol using filtered back projection. Further subgroups with tube voltage modulations were established. Quantitative and qualitative image quality was assessed. RESULTS: The radiation dose in groups with comparable image quality was approximately 40% lower using IR compared with filtered back projection. The IR protocol combined with 80-kV tube voltage showed adequate image quality with a mean effective dose of only 0.47 mSv. CONCLUSIONS: Iterative reconstruction helps extensively reduce radiation dose by improving image quality. It permits the use of low-kilovolt protocols without significantly degrading image reading ability in the monitoring of the predominantly young patients with CF.


Assuntos
Fibrose Cística/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Adulto Jovem
12.
Acta Radiol ; 58(12): 1468-1475, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28406048

RESUMO

Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.


Assuntos
Cateterismo Venoso Central/economia , Cateterismo Venoso Central/métodos , Análise Custo-Benefício/economia , Curva de Aprendizado , Serviço Hospitalar de Radiologia/economia , Radiologia/educação , Cateterismo Venoso Central/instrumentação , Cateteres Venosos Centrais/economia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/economia , Estudos Retrospectivos , Fatores de Tempo
13.
Emerg Med J ; 34(10): 643-646, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28130347

RESUMO

OBJECTIVE: To evaluate the number, localisation and importance of non-traumatic incidental findings (IFs) in patients with suspected or obvious multiple trauma undergoing whole-body CT (WBCT) in a level-1 trauma centre. METHODS: Between January 2009 and December 2013, a total of 2440 patients with trauma undergoing WBCT at admission to a level-1 trauma centre of a university hospital were retrospectively analysed, through imaging IFs unrelated to trauma with the radiological reports. All IFs were grouped into four categories according to their clinical relevance. Category 1: urgent treatment or further clarification needed; category 2: further examination and follow-up within 3-6 months required; category 3: findings with no immediate consequences for the treatment of the patient but of potential relevance in the future; category 4: harmless findings. RESULTS: Altogether, 5440 IFs in 2440 patients (1735 male, 705 female; mean age 45.1 years) were documented. In 204 patients (8.4%) urgent category 1 findings were reported, 766 patients (31.4%) had category 2 findings, 1236 patients (50.7%) had category 3 findings and 1173 patients (48.1%) had category 4 findings. Most IFs were detected in the abdomen/pelvis (42.5%). 602 (24.7%) of the patients had no IFs. CONCLUSIONS: WBCT scans of unrelated trauma patients demonstrate a high rate of IF. A substantial percentage (8.4%) of patients had urgent category 1IFs and a high percentage (31.4%) had category 2 IFs requiring a follow-up. This high number of patients with polytrauma undergoing WBCT, having IFs of high relevance, poses a major challenge for the level-1 trauma centre in the acute and postacute management of these patients.


Assuntos
Achados Incidentais , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total , Adulto , Idoso , Serviço Hospitalar de Emergência/organização & administração , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/diagnóstico , Estudos Retrospectivos
14.
J Bone Miner Metab ; 34(1): 55-64, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25687428

RESUMO

The first objective of this study was to determine normative digital X-ray radiogrammetry (DXR) values, based on original digital images, in a pediatric population (aged 6-18 years). The second aim was to compare these reference data with patients suffering from distal radius fractures, whereas both cohorts originated from the same geographical region and were evaluated using the same technical parameters as well as inclusion and exclusion criteria. DXR-BMD and DXR-MCI of the metacarpal bones II-IV were assessed on standardized digital hand radiographs, without printing or scanning procedures. DXR parameters were estimated separately by gender and among six age groups; values in the fracture group were compared to age- and gender-matched normative data using Student's t tests and Z scores. In the reference cohort (150 boys, 138 girls), gender differences were found in bone mineral density (DXR-BMD), with higher values for girls from 11 to 14 years and for boys from 15 to 18 years (p < 0.05). Girls had higher normative metacarpal index (DXR-MCI) values than boys, with significant differences at 11-14 years (p < 0.05). In the case-control investigation, the fracture group (95 boys, 69 girls) presented lower DXR-BMD at 15-18 years in boys and 13-16 years in girls vs. the reference cohort (p < 0.05); DXR-MCI was lower at 11-18 years in boys and 11-16 years in girls (p < 0.05). Mean Z scores in the fracture group for DXR-BMD were -0.42 (boys) and -0.46 (girls), and for DXR-MCI were -0.51 (boys) and -0.53 (girls). These findings indicate that the fully digital DXR technique can be accurately applied in pediatric populations ≥ 6 years of age. The lower DXR-BMD and DXR-MCI values in the fracture group suggest promising early identification of individuals with increased fracture risk, without the need for additional radiation exposure, enabling the initiation of prevention strategies to possibly reduce the incidence of osteoporosis later in life.


Assuntos
Fraturas do Rádio/diagnóstico por imagem , Absorciometria de Fóton , Adolescente , Densidade Óssea/fisiologia , Feminino , Humanos , Masculino , Intensificação de Imagem Radiográfica , Valores de Referência , Raios X
15.
Acta Radiol ; 57(3): 362-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25852193

RESUMO

BACKGROUND: Rising numbers of computed tomography (CT) examinations worldwide have led to a focus on dose reduction in the latest developments in CT technology. Iterative reconstruction (IR) models bear the potential to effectively reduce dose while maintaining adequate image quality. PURPOSE: To assess the impact of adaptive statistical iterative reconstruction (ASIR) technique on dose reduction and image quality in a dedicated whole body CT (WBCT) protocol for trauma patients. MATERIAL AND METHODS: A total of 122 subjects with multiple trauma was prospectively included in our study. Subjects who had to undergo a WBCT following a severe trauma were randomly assigned to two different groups: Group A was examined with an ASIR protocol for the body series (n = 64), group B (n = 58) was examined using a standard filtered back projection (FBP) protocol. Image quality was assessed both quantitatively by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNRs) and qualitatively by two observers who evaluated image quality using a 5-point scale system. Applied dose was analyzed as CTDIvol (mGy), total DLP (mGyxcm), and effective dose (mSv). RESULTS: Applied dose for the body series in group A was about 23% lower than in group B (P < 0.05). SNR and CNRs for different tissues were not significantly different. Subjective image quality ratings were excellent and showed no significant difference, with a high inter-reader agreement. CONCLUSION: ASIR contributes to a relevant dose reduction without any loss of image quality in a dedicated WBCT protocol for patients with multiple trauma.


Assuntos
Traumatismo Múltiplo/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
18.
Skeletal Radiol ; 44(5): 695-701, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25371086

RESUMO

OBJECTIVE: To evaluate the use of a novel battery-powered drill, enabling specimen requirement while drilling, in radiofrequency ablation of osteoid osteoma as an alternative to conventional orthopedic drills. MATERIALS AND METHODS: Between 2009 and 2013, altogether 33 patients underwent CT-guided radiofrequency ablation of an osteoid osteoma at our institution. To access the nidus of the clinically and radiologically suspected osteoid osteoma, a channel was drilled using the OnControl Bone Marrow Biopsy System (OBM, Arrow OnControl, Teleflex, Shavano Park, TX, USA) and a biopsy was taken. Procedure time (i.e., drilling including local anesthesia), amount of scans (i.e., single-shot fluoroscopy), radiation exposure, and the results of biopsy were investigated and compared retrospectively to a classical approach using either a manual bone biopsy system or a conventional orthopedic drill (n = 10) after ethical review board approval. RESULTS: Drilling the tract into the nidus was performed without problems in 22 of the 23 OBM cases. Median procedure time was 7 min compared to 13 min using the classical approach (p < 0.001). Median amount CT scans, performed to control correct positioning of the drill was comparable with 26 compared to 24.5 (p = NS) scans. Histologically, the diagnosis of osteoid osteomas could be determined in all 17 cases where a biopsy was taken. Radiofrequency ablation could be performed without problems in any case. CONCLUSIONS: The use of the battery-powered drill was feasible and facilitated the access to the osteoid osteoma's nidus offering the possibility to extract a specimen in the same step.


Assuntos
Neoplasias Ósseas/cirurgia , Ablação por Cateter/instrumentação , Osteoma Osteoide/cirurgia , Osteotomia/instrumentação , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Adolescente , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Criança , Pré-Escolar , Fontes de Energia Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoma Osteoide/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem
19.
Eur Radiol ; 24(11): 2685-91, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25007868

RESUMO

OBJECTIVES: To assess the impact of ASIR (adaptive statistical iterative reconstruction) and lower tube potential on dose reduction and image quality in chest computed tomography angiographies (CTAs) of patients with pulmonary embolism. MATERIALS AND METHODS: CT data from 44 patients with pulmonary embolism were acquired using different protocols-Group A: 120 kV, filtered back projection, n = 12; Group B: 120 kV, 40 % ASIR, n = 12; Group C: 100 kV, 40 % ASIR, n = 12 and Group D: 80 kV, 40 % ASIR, n = 8. Normalised effective dose was calculated; image quality was assessed quantitatively and qualitatively. RESULTS: Normalised effective dose in Group B was 33.8 % lower than in Group A (p = 0.014) and 54.4 % lower in Group C than in Group A (p < 0.001). Group A, B and C did not show significant differences in qualitative or quantitative analysis of image quality. Group D showed significantly higher noise levels in qualitative and quantitative analysis, significantly more artefacts and decreased overall diagnosability. Best results, considering dose reduction and image quality, were achieved in Group C. CONCLUSIONS: The combination of ASIR and lower tube potential is an option to reduce radiation without significant worsening of image quality in the diagnosis of pulmonary embolism. KEY POINTS: • Iterative algorithms and lowering of tube potential reduce radiation without compromising interpretability • 40 % ASIR and 100 kV tube potential led to a 54.4 % dose reduction • 40 % ASIR and 80 kV tube potential led to significantly worse image quality.


Assuntos
Algoritmos , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes
20.
Acta Oncol ; 53(6): 759-68, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24299492

RESUMO

BACKGROUND: The aim of this study was to evaluate imaging-based response to standardized neoadjuvant chemotherapy (NACT) regimen by dynamic contrast-enhanced magnetic resonance mammography (DCE-MRM), whereas MR images were analyzed by an automatic computer-assisted diagnosis (CAD) system in comparison to visual evaluation. MRI findings were correlated with histopathologic response to NACT and also with the occurrence of metastases in a follow-up analysis. PATIENTS AND METHODS: Fifty-four patients with invasive ductal breast carcinomas received two identical MRI examinations (before and after NACT; 1.5T, contrast medium gadoteric acid). Pre-therapeutic images were compared with post-therapeutic examinations by CAD and two blinded human observers, considering morphologic and dynamic MRI parameters as well as tumor size measurements. Imaging-assessed response to NACT was compared with histopathologically verified response. All clinical, histopathologic, and DCE-MRM parameters were correlated with the occurrence of distant metastases. RESULTS: Initial and post-initial dynamic parameters significantly changed between pre- and post-therapeutic DCE-MRM. Visually evaluated DCE-MRM revealed sensitivity of 85.7%, specificity of 91.7%, and diagnostic accuracy of 87.0% in evaluating the response to NACT compared to histopathology. CAD analysis led to more false-negative findings (37.0%) compared to visual evaluation (11.1%), resulting in sensitivity of 52.4%, specificity of 100.0%, and diagnostic accuracy of 63.0%. The following dynamic MRI parameters showed significant associations to occurring metastases: Post-initial curve type before NACT (entire lesions, calculated by CAD) and post-initial curve type of the most enhancing tumor parts after NACT (calculated by CAD and manually). CONCLUSIONS: In the accurate evaluation of response to neoadjuvant treatment, CAD systems can provide useful additional information due to the high specificity; however, they cannot replace visual imaging evaluation. Besides traditional prognostic factors, contrast medium-induced dynamic MRI parameters reveal significant associations to patient outcome, i.e. occurrence of distant metastases.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Carcinoma Ductal de Mama/tratamento farmacológico , Interpretação de Imagem Assistida por Computador , Terapia Neoadjuvante , Adulto , Idoso , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/patologia , Estudos de Coortes , Ciclofosfamida/administração & dosagem , Diagnóstico por Computador , Docetaxel , Doxorrubicina/administração & dosagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia , Mastectomia , Pessoa de Meia-Idade , Taxoides/administração & dosagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA