Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Br J Surg ; 108(3): 302-307, 2021 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-33793745

RESUMO

BACKGROUND: Several techniques for targeted lymph node biopsy in patients with node-positive breast cancer receiving primary systemic therapy are in use, each with their inherent advantages and disadvantages. The aim of the TATTOO trial was to evaluate the feasibility and accuracy of carbon tattooing of positive lymph nodes as a method for targeted lymph node biopsy avoiding radiation exposure, high costs, and preoperative localization procedures. METHODS: Patients with initially cT1-4c cN1-3 cM0 invasive breast cancer were included in this prospective multicentre trial. Before initiation of primary systemic therapy, a carbon suspension was injected into the most suspicious axillary lymph node. Targeted lymph node biopsy was performed in all patients after completion of primary systemic therapy. Additional sentinel lymph node biopsy was done in those with axillary downstaging, and completion axillary lymph node dissection in patients still presenting with suspicious lymph nodes. RESULTS: A total of 118 patients were included and 110 were eligible for data analysis. The detection rate for the targeted lymph node was 93.6 per cent (103 of 110), and the sentinel lymph node was identical to the targeted lymph node in 60 per cent. The false-negative rate for the combination of targeted and sentinel node lymph node biopsy (targeted axillary dissection) was 9 per cent. CONCLUSION: Targeted axillary dissection after carbon tattooing is associated with a high detection rate, an acceptable false-negative rate, and appears feasible for clinical use even in healthcare settings with limited resources.


Assuntos
Biópsia/métodos , Carbono , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/diagnóstico , Tatuagem , Adulto , Idoso , Neoplasias da Mama , Feminino , Humanos , Linfonodos/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia
2.
Aesthetic Plast Surg ; 39(4): 523-33, 2015 08.
Artigo em Inglês | MEDLINE | ID: mdl-26085227

RESUMO

INTRODUCTION: Implant-based breast reconstructions (IBBR) using alternatives to acellular dermal matrixes are increasing. Data on complications are limited, and information concerning health-related quality of life (HR-QoL) following the use of these synthetic meshes do not exist. METHODS: Between January 2006 and January 2013, patients undergoing immediate or delayed-immediate IBBR with or without titanium covered polypropylene mesh (TiLOOP® Bra) were investigated. HR-QoL was assessed using the validated self-reporting BREAST-Q questionnaire. Patient demographics and complications were evaluated retrospectively. Stepwise regression backward elimination analysis was performed to identify influential factors on each BREAST-Q domain. RESULTS: Of the 90 women, 42 had IBBR alone and 48 in combination with TiLOOP® Bra. The mean follow-up was 18 months in the TiLOOP® Bra and 17.5 months in the implant alone group (p = 0.827). The overall complication rate was 21.1 %, with 14.6 % in the TiLOOP® Bra and in 28.6 % in the implant alone group (p = 0.105). Capsular contraction rate was 4.4 % in the TiLOOP® Bra and 16.7 % in the implant alone group (p = 0.052). The analysis of the HR-QoL showed no significant differences between the groups. Surgeries prior to IBBR had a positive influence on HR-QoL. TiLOOP® Bra was associated with a negative effect on "satisfaction with breast" (ß = -5.72; p < 0.001), as it was no longer observed for "satisfaction with outcome" and other domains.


Assuntos
Implantes de Mama , Mamoplastia , Satisfação do Paciente , Qualidade de Vida , Autorrelato , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Polipropilenos , Desenho de Prótese , Estudos Retrospectivos , Telas Cirúrgicas , Titânio
3.
Ultraschall Med ; 34(2): 131-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23108926

RESUMO

PURPOSE: We compared strain ratio vs. qualitative elastography for the further differentiation of focal breast lesions, with special focus on limiting factors. MATERIALS AND METHODS: 215 patients with 224 histologically proven breast masses (116 malignant, 108 benign) were prospectively examined using a high-end ultrasound system (Philips iU22) with serial elastography function. B-mode scans and available mammograms were reviewed according to the BIRADS classification, raw elastogram data was analyzed qualitatively using the Tsukuba score and semiquantitatively by calculating the strain ratio (fat to lesion ratio). For diagnostic performance, Receiver Operating Characteristic (ROC) curve analysis was obtained. A sub-group analysis regarding breast density, lesion size, lesion depth and histological subtypes was performed. RESULTS: Mean strain ratio values were 3.04 ± 0.9 for malignant and 1.91 ± 0.75 for benign lesions (p < 0,001). The areas under the ROC curve values were 0.832 (95 % CI 0.777; 0.888) for strain ratio, 0.869 (95 % CI 0.822; 0.917) for Tsukuba score, 0.822 (95 % CI 0.768; 0.876) for B-mode ultrasound and 0.853 (95 % CI 0.799; 0.907) for mammography. Sensitivity, specificity, positive predictive value and negative predictive value of the strain ratio were 90.7 %, 58.2 %, 70.3 % and 85.1 %, when a cutoff point of 2.0 was used. Only lesion depth ≤ 4 mm was associated with diagnostic failure in the multivariate analysis of factors influencing accuracy, whereas no significant correlation between breast density and lesion size and the accuracy of the strain ratio could be found. CONCLUSION: The addition of strain ratio to B-mode ultrasound increases specificity without loss of sensitivity in differentiating between malignant and benign breast tumors. Strain ratio measurements should not be carried out on tumors with a lesion depth ≤ 4 mm.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Software , Adulto Jovem
4.
Aesthetic Plast Surg ; 37(1): 91-4, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23288097

RESUMO

Since the scandal of the poly-implant protheses (PIP) breast implants, all patients with PIP are advised to have their implants removed. With approximately 400,000 PIP implants sold worldwide breast, surgeons will be confronted with these patients. Histologic examination in the reported case showed silicone infiltration into fatty tissue and breast tissue without signs of malignancy. A general histologic analysis for the rare event of an anaplastic large T cell lymphoma is not advised. The malignant potential of PIP implants currently is uncertain, and further investigation is required. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Implantes de Mama/efeitos adversos , Mamoplastia , Falha de Prótese , Adulto , Administração de Caso , Feminino , Humanos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/patologia
5.
Arch Gynecol Obstet ; 280(6): 1007-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19306100

RESUMO

We report of a maternal sternal fracture during a spontaneous delivery in a 31-year-old primipara without a suitable trauma. The putative mechanism of fracture was strong hyperflexion of the thoracic spine and additional cervical flexion with pushing the chin to the thorax due to active management of labour. The history of the healthy woman was free of related risk factors. A possible promoting factor might be pregnancy-induced bone loss. Although there were clear symptoms, the diagnosis of the fracture was delayed by a week because nobody took account of such a possibility.


Assuntos
Parto Obstétrico/efeitos adversos , Fraturas Ósseas/etiologia , Esterno/lesões , Adulto , Feminino , Fraturas Ósseas/diagnóstico , Humanos , Recém-Nascido , Gravidez
7.
Geburtshilfe Frauenheilkd ; 76(2): 170-175, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26941450

RESUMO

Endometrial carcinoma is the most common carcinoma of the female genital tract. Its most important clinical sign is postmenopausal bleeding. An endometrial biopsy is essential for diagnosis. Treatment decisions are governed by tumour risk assessment and patient comorbidity, which is often present. Pelvic and paraaortic lymph node dissection is unnecessary in low risk cases (definition: pT1 a, G1/2) and adjuvant radiotherapy and systemic treatments are usually avoidable. Treatment of high-risk patients (G3 and/or pT1b) and palliative cases is difficult and not well standardised. New molecular-based subtype classification may help treatment decision making in future.

8.
Geburtshilfe Frauenheilkd ; 75(7): 692-701, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26257406

RESUMO

Background: Complication rates and surgical outcomes are well reported for implant-based breast reconstruction (IBBR) using supportive materials for the inferior pole of the breast. Patient-reported outcomes (PRO) are underrepresented. The aim of this study was to compare PRO in IBBR using implants alone or in combination with a synthetic mesh. Methods and Methods: PRO was measured in patients undergoing IBBR alone or in combination with a titanium-covered polypropylene mesh (TiLOOP® Bra). In this non-randomized observational trial PRO was retrospectively assessed using the validated self-reporting BREAST-Q. The raw responses of all questions applied in each domain and transformed BREAST-Q data using the Q-Score are presented. Results: Of 90 eligible women, 42 received IBBR alone and 48 received IBBR in combination with mesh. No differences in complication rates were observed. The return rate was 67.7 % and was comparable between the groups (p = 0.117). PRO revealed no differences regarding satisfaction with breast shape (p = 0.079), outcome (p = 0.604), nipple sensitivity (p = 0.502), preoperative information (p = 0.195), office staff (p = 0.462), psychosocial well-being (p = 0.370), sexual well-being (p = 0.508) and physical well-being (p = 0.654). Significant differences were noted regarding satisfaction with the surgeon (p = 0.013) and medical staff (p = 0.035) as well as the response behavior of certain questions of the sub-domains, thus helping to further stratify PRO with regards to aesthetic outcome. However, no differences were observed in the main BREAST-Q results. Conclusion: Use of the TiLOOP® Bra in IBBR results in comparable BREAST-Q scores compared with IBBR alone. Evaluating the BREAST-Q sub-domains helps to stratify PRO more profoundly and assists in interpreting the overall results and specific research questions.

9.
Ultrasound Int Open ; 1(1): E19-24, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27689144

RESUMO

PURPOSE: To evaluate the accuracy of axillary ultrasound (AUS) in detecting nodal metastasis in patients with early-stage breast cancer and to identify AUS features with high predictive power. MATERIALS AND METHODS: Prospective single-center preliminary study in 105 patients with a primary diagnosis of breast cancer and clinically negative axilla. AUS was performed using a 12 MHz linear-array transducer before ultrasound-guided needle biopsy. Nodal characteristics (shape, longitudinal-transverse [LT] axis ratio, margins, cortical thickness, hyperechoic hilum) were correlated with histopathological nodal status after SLNB or axillary lymph node dissection (ALND). RESULTS: Nodal metastases were present in 42/105 patients (40.0%). Univariate analyses showed that absence of hyperechoic hilum, round shape, LT axis ratio<2, sharp margins and cortical thickness>3 mm were associated with lymph node metastasis. Multivariate logistic regression analysis revealed cortical thickness > 3 mm as an independent predictive parameter for nodal involvement. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 66.7, 74.6, 63.6, 77.0% and 71.4% respectively when cortical thickness > 3 mm was applied as the criterion for AUS positivity. Axillary tumor volume was low in patients with pT1/2 tumors and negative AUS, since only 3.2% of patients had > 2 metastatic lymph nodes. CONCLUSION: Cortical thickness>3 mm is a reliable predictor of nodal metastatic involvement. Negative AUS does not exclude lymph node metastases, but extensive axillary tumor volume is rare.

10.
Breast ; 23(4): 346-51, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24559611

RESUMO

BACKGROUND: Ductal carcinoma in situ (DCIS) often accompanies invasive ductal carcinoma (IDC). The presence of co-existing DCIS is postulated to present as a less aggressive phenotype than IDC alone. PATIENTS AND METHODS: Patients diagnosed with hormone receptor-positive breast cancer receiving mastectomy were evaluated. Only patients without adjuvant radio- and chemotherapy were included to decrease treatment bias on local recurrence (LR). RESULTS: Of 2239 breast cancer patients, 198 fulfilled the inclusion criteria. The overall LR rate was 11.6%. Tumor stage (p = 0.002), nodal status (pN2 vs. pN0, p = 0.023) and pure IDC compared with IDC-DCIS (p = 0.029) were multivariate independent factors for increased LR risk. Patients with IDC-DCIS were significantly younger (p < 0.001), had smaller tumors (p = 0.001), less lymph node involvement (p = 0.012). The LR rate was significantly increased in patients with pure IDC (p = 0.012). The time to distant metastases was decreased in patients with pure IDC compared with that observed in patients with IDC-DCIS (log rank = 0.030). CONCLUSION: Invasive ductal carcinoma accompanied by DCIS is associated with lower LR. The prognostic value of co-existing DCIS in the adjuvant decision-making process may be considered a new independent prognostic marker. This finding needs further studies to evaluate its usefulness in premenopausal women.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Mastectomia , Recidiva Local de Neoplasia/patologia , Neoplasias Primárias Múltiplas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Intraductal não Infiltrante/cirurgia , Estudos de Coortes , Intervalo Livre de Doença , Feminino , Humanos , Pessoa de Meia-Idade , Análise Multivariada , Neoplasias Primárias Múltiplas/cirurgia , Prognóstico , Estudos Retrospectivos
11.
Eur J Surg Oncol ; 38(12): 1225-30, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22981749

RESUMO

INTRODUCTION: A new approach for implant based breast reconstruction (IBBR) is the use of a titanium-coated polypropylene mesh (TCPM) as an alternative to acellular dermal matrix (ADM). This TCPM has a good biocompatibility and can be used similarly to ADM. The aim of this study is to discuss indications, limitations and complications of TCPM in IBBR. METHODS: A retrospective analysis of 42 patients undergoing immediate or delayed IBBR using a TCPM was performed. Primary endpoints were incidence of infection and expander/implant with mesh removal due to infected fluid collection or extrusion. RESULTS: In two patients, mild hematoma, seroma or infection occurred. Skin necrosis or capsular contraction was observed in one patient. Mesh explantation was needed in 3 cases. These events were higher among the first cases and in patients with postoperative skin infection (p = 0.003). CONCLUSION: In selected patients with adequate soft tissue cover TCPM seems to be a helpful tool for implant stabilization in terms of lateral stabilization and fixation of the musculus pectoralis major. In comparison to ADM, TCPM is cheaper and initial results are promising, but further follow-up data are necessary. In patients with poor soft tissue cover ADM should be used.


Assuntos
Implantes de Mama , Materiais Revestidos Biocompatíveis , Mamoplastia/métodos , Polipropilenos , Telas Cirúrgicas , Titânio , Adolescente , Adulto , Neoplasias da Mama/cirurgia , Feminino , Seguimentos , Humanos , Mastectomia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
Pregnancy Hypertens ; 2(3): 303, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26105439

RESUMO

INTRODUCTION: Severe preeclampsia is associated with characteristic changes of sFlt-1 and PlGF levels in the maternal serum. OBJECTIVES: The aim of our study is the determination of the predictive value of sFlt-1 and PlGF for preeclampsia and other pregnancy associated diseases in women with a pathological uterine Doppler measurement during the second trimester of pregnancy. METHODS: An updated analysis of an ongoing prospective trial will be presented. Criterion of inclusion was a bilateral pathological uterine Doppler measurement with an increase of the resistance index (RI) >95th percentile and/or a bilateral postsystolic notch during 19 and 24 weeks. Ratio of sFlt-1 and PlGF was repeatedly measured during pregnancy using a full-automated system (Elecsys®, Roche). RESULTS: Presently, we recruited 36 patients. Full data are available from 17 patients. Out of these in 23.5% (n=4) a delivery before 37 weeks was indicated. 41% of all newborns (7/17) showed a birth weight <5th percentile. 23.5% of all patients developed a hypertensive pregnancy disorder but without fulfilling the criterions of preeclampsia. Only two patients had a sFlt-1/PlGF ratio >95th percentile. In both cases we found severe fetal growth retardation. One of them developed a pregnancy related hypertension based on an antiphospholipid syndrome. CONCLUSION: The additional measurement of the sFlt-1/PlGF ratio in a high risk group of pregnancies may improve the prediction of severe pregnancy related diseases during the second trimester. But keeping the low incidence of severe preeclampsia in mind, the measurements seem to be only usefulness in a high risk population. Although we reported presently only of a small part of our study population the sFlt-1/PlGF ratio did not revealed a good specificity for prediction of preeclampsia. Pathological values were also found in cases with fetal growth retardation without signs of preeclampsia.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA