Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Cardiovasc Electrophysiol ; 26(8): 845-852, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25917416

RESUMO

BACKGROUND: The accessory pathway (AP) connecting the right atrial appendage (RAA) and the right ventricle (RV) is rare. OBJECTIVE: We sought to investigate the feature of the AP connecting the RAA and the RV and the efficacy of radiofrequency catheter ablation via the endocardial access. METHODS: We retrospectively analyzed 14 consecutive patients with 14 APs connecting the RAA and the RV managed by 15 procedures between January 2003 and December 2014. RESULTS: Ten patients presented as preexcitation during sinus rhythm. All APs had retrograde conduction. None had either antegrade or retrograde decremental conduction property. Ablation targeting the sites at the tricuspid annulus failed in all patients. They were successfully managed by ablating the atrial insertion sites with a median of 10.5 (range 5-28) radiofrequency applications. Electrograms at the successful target showed high amplitude atrial electrogram and low amplitude or no ventricular electrogram. The atrial insertion sites were at the floor of the RAA in 10 patients and inside the lower lobe of the RAA in the remaining 4 patients. The shortest distance between the successful target and the tricuspid annulus in the right anterior oblique projection was 19.7 ± 4.0 mm. There were no complications or recurrences during a median follow-up period of 4.3 (range 0.2-11.8) years. CONCLUSION: The APs connecting the RAA and the RV had typical conduction properties. The atrial insertion site favored the floor and the lower lobe of the RAA. Ablation targeting the atrial insertion sites was effective and safe, albeit multiple radiofrequency applications were needed.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Arritmias Cardíacas/cirurgia , Apêndice Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração/cirurgia , Feixe Acessório Atrioventricular/fisiopatologia , Potenciais de Ação , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Apêndice Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
2.
Pacing Clin Electrophysiol ; 38(9): 1073-81, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26096255

RESUMO

BACKGROUND: Cryoballoon ablation is an alternative for the treatment of atrial fibrillation (AF). We assess the relationship among pulmonary vein (PV) electrophysiology, balloon temperature, and persistent PV isolation (PVI), and report procedural properties, safety, and efficacy of this technique in a Chinese center for the first time. METHODS: A total of 70 patients with paroxysmal (n = 57) and persistent (n = 13) AF were consecutively enrolled. PVI was performed with cryoballoon catheter. Real-time recording of dissociation of PV potentials was attempted using a circumferential mapping catheter. RESULTS: Successful PVI was achieved in 274 of 282 (97.2%) PVs. Procedural duration was 115.2 ± 24.8 minutes and fluoroscopy time was 29.6 ± 8.9 minutes. Real-time PV potential recording was achieved in 232 (84.3%) PVs. Regarding time to isolation, a cut-off value of less than 60 seconds was predictive of persistent PVI with a sensitivity of 0.76 and specificity of 0.82 (area under curve = 0.835; P < 0.0001). The nadir balloon temperature was significantly lower in PVs without early reconduction (-46.3 ± 0.5°C vs -40.2 ± 1.3°C, P < 0.0001). However, there was an insignificant trend that the balloon temperature at isolation was higher in PVs without reconduction (-33.9 ± 0.7°C vs -36.4 ± 2.0°C, P = 0.14). The overall complication rate was 5.7%. After a median follow-up of 6.5 (range 3.2-14.9) months, 76% of patients were free of AF recurrence with a blanking period of 3 months. CONCLUSIONS: Real-time PV potentials can be recorded in most PVs. The time to isolation is predictive of the persistency of PVI. The nadir balloon temperature, not the balloon temperature at isolation, is significantly lower in PVs without reconduction.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Cateterismo Cardíaco/instrumentação , China , Criocirurgia/instrumentação , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia
3.
Oncol Lett ; 11(4): 2491-2496, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27073504

RESUMO

Lymphoepithelioma-like gastric carcinoma (LELGC) is a rare neoplasm of the stomach that accounts for 1-4% of all gastric cancer cases. It is characterized by the presence of a lymphoid stroma with cells arranged primarily in micro alveolar, thin trabecular and primitive tubular patterns or isolated cells. In the present study, the case of a 50-year-old male patient with LELGC and rectal laterally spreading tumor is presented. Following endoscopic submucosal dissection, a diagnosis of carcinoma was reached and the patient underwent total radical gastrectomy. The postoperative pathological stage was IA T1bN0cM0 according to the Tumor-Node-Metastasis classification of gastric carcinoma, and the patient recovered well. The present case is reported to summarize the endoscopic and pathological characteristics of LELGC.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA