Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(7): 4300-4308, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38147169

RESUMO

OBJECTIVES: Currently, there is no standardized measurement method for evaluating cup overhang (CO) in patients undergoing total hip arthroplasty (THA). We propose a novel, standardized method of measuring overhang distance in patients following primary total hip arthroplasty (THA) on computed tomography (CT) images after multiplanar reformation and compare it to a previously proposed measurement method on sagittal CT images. MATERIALS AND METHODS: This retrospective study included patients who underwent primary THA with an anterior approach. Patients with cup overhang (CO) and iliopsoas impingement (IPI) were identified by clinical and imaging data. Uncorrected overhang distance (ODu) was evaluated on orthogonal sagittal CT images while corrected overhang distance (ODc) was evaluated on reformatted sagittal CT images corrected for pelvic rotation and aligned with the plane of the cup face. RESULTS: Out of 220 patients with THA, 23 patients (10.4%) with CO and 16 patients (7.3%) with IPI were identified. CO was significantly associated to IPI (p < 0.001). The inter- and intrareader agreement was almost perfect for ODc (κ = 0.822, κ = 0.850), whereas it was fair and moderate for ODu (κ = 0.391, κ = 0.455), respectively. The discriminative ability of ODc was excellent (area under the curve (AUC) = 0.909 (95% confidence interval (CI) 0.784-1.000)) in the receiver operating characteristic analysis. Conversely, AUC for ODu was poor, measuring 0.677 (95% CI 0.433-0.921). CONCLUSION: We implemented a novel measurement method for CT images reformatted at the plane of the cup face to assess overhang distance in patients with CO following THA. CLINICAL RELEVANCE STATEMENT: While further validation is necessary, the proposed method is characterized by its high reproducibility and might be used to predict the occurrence of iliopsoas impingement in patients with cup overhang following total hip arthroplasty. KEY POINTS: • A novel, standardized method of measuring cup overhang distance in patients following primary total hip arthroplasty on CT images is proposed. • Cup overhang was associated to iliopsoas impingement. The proposed method was reproducible and showed excellent prediction of iliopsoas impingement in patients with cup overhang. • This method can be implemented in clinical practice when assessing CT images of patients with cup overhang for iliopsoas impingement.


Assuntos
Artroplastia de Quadril , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Músculos Psoas/diagnóstico por imagem , Prótese de Quadril , Idoso de 80 Anos ou mais
2.
Eur Radiol ; 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38958696

RESUMO

OBJECTIVES: To assess radiopalmar ganglion cysts' (RPG) prevalence, morphology, and clinical significance in consecutive patients. MATERIALS AND METHODS: In this retrospective single-center study, two radiologists assessed the presence of RPG and morphologic features on wrist MRI. Radiopalmar complaints and scapholunate ligament (SLL) tears were evaluated. RESULTS: A total of 1053 wrists in 909 patients (mean age 43.4 ± 15.5 years, 602 females) were evaluated. All 308 RPG (Group 1; 308 patients, 29.2%) originated from the palmar capsule; 49 were unilocular, 95 oligolocular, and 164 multilocular; 745 wrists had no RPG (Group 2; 601 patients). One hundred and twenty-six RPG showed internal debris. The mean diameter was 8.5 ± 5.6 mm (cranio-caudal) (1.0-32.9 mm), 8.0 ± 4.1 mm (medio-lateral) (1.0-31.9 mm), and 3.7 ± 2.3 mm (dorso-palmar) (0.4-16.0 mm). 168 RPG showed direct contact with the radial vascular bundle, 24 with the flexor carpi radialis tendon, and 123 with the flexor pollicis longus tendon. In Group 1, significantly more patients showed partial (82/308) [group 2: 45/745, p < 0.001] or complete SLL tears (22/308) [group 2: 20/745, p < 0.001]. Of the patients with RPG, 15.3% presented with radiopalmar complaints. Only the dorso-palmar RPG diameter was positively correlated with radiopalmar complaints (for readers 1 and 2: rs = 0.66/0.61, p < 0.001, respectively), and the best dorso-palmar diameter cut-off value for the probability of having radiopalmar complaints was defined at 3 mm (area under the curve (AUC) 0.74). Other morphologic features were not eligible to discriminate symptomatic patients (AUC range 0.53-0.61). CONCLUSION: This study found RPG in 29% of patients, most of them asymptomatic. However, a dorso-palmar cyst diameter > 3 mm may be clinically significant. CLINICAL RELEVANCE STATEMENT: Radiopalmar ganglion cysts, observed in 29% of wrist MR examinations, are mostly asymptomatic, but those with a larger dorso-palmar diameter may be associated with radiopalmar complaints. KEY POINTS: Radiopalmar ganglion cysts are found in 29% of patients undergoing wrist MRI. Most patients with evidence of radiopalmar ganglion cysts do not show radiopalmar symptoms (85%). A dorso-palmar cyst diameter > 3 mm may be associated with radiopalmar complaints.

3.
Eur Radiol ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992107

RESUMO

OBJECTIVES: The aim of this study was to introduce the blackbird sign as a fast, qualitative measure of early supraspinatus (SSP) muscle atrophy and to correlate the sign with quantitatively assessed muscle volume and intramuscular fat fraction (FF) in patients with full-thickness SSP tears. MATERIALS AND METHODS: The blackbird sign describes the asymmetric pattern of early SSP atrophy: on sagittal MR images, the supero-posterior contour of the muscle becomes concave, resembling the shape of a blackbird. MRIs of patients with full-thickness SSP tears were retrospectively reviewed for the presence of the blackbird and tangent signs. Patients were then divided into group 1: negative tangent sign and negative blackbird sign (n = 67), group 2: negative tangent sign and positive blackbird sign (n = 31), and group 3: positive tangent sign (n = 32). A 2-point Dixon sequence was acquired in all patients from which quantitative FF and muscle volumes were calculated. RESULTS: In total 130 patients (mean age 67 ± 11 years) were included. Mean SSP volume was significantly smaller in group 3 (15.8 ± 8.1 cm3) compared to group 2 (23.9 ± 7.0 cm3, p = 0.01) and group 1 (29.7 ± 9.1 cm3, p < 0.01). Significantly lower muscle volumes were also found in group 2 compared to group 1 (p = 0.02), confirming that the blackbird sign is able to identify early SSP atrophy. Mean FF in the SSP was significantly higher in group 3 (18.5 ± 4.4%) compared to group 2 (10.9 ± 4.7%, p < 0.01) and group 1 (6.1 ± 2.6%, p < 0.01). CONCLUSION: Visual assessment of early muscle atrophy of the SSP is feasible and reproducible using the blackbird sign, allowing the diagnosis of early SSP atrophy. CLINICAL RELEVANCE STATEMENT: In routine clinical practice, the blackbird sign may be a useful tool for assessing early muscle degeneration before the risk of postoperative rotator cuff re-tears increases with progressive muscle atrophy and fatty infiltration. KEY POINTS: Quantitative measurements of rotator cuff injuries require time, limiting clinical practicality. The proposed blackbird sign is able to identify early SSP atrophy. Reader agreement for the blackbird sign was substantial, demonstrating reproducibility and ease of implementation in the clinical routine.

4.
AJR Am J Roentgenol ; 222(1): e2329950, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37646386

RESUMO

BACKGROUND. Photon-counting detector (PCD) CT could be useful to help address the typically high radiation doses of conventional energy-integrating detector (EID) CT of the lumbar spine. OBJECTIVE. The purpose of our study was to compare PCD CT and EID CT of the lumbar spine, both performed using tin filtration, in terms of radiation dose and image quality. METHODS. This study included a prospective sample of 39 patients (22 men, 17 women; mean age, 27.2 years) who underwent investigational PCD CT of the lumbar spine as part of a separate study and a retrospective sample of 39 patients (22 men, 17 women; mean age, 34.9 years) who underwent clinically indicated EID CT of the lumbar spine. In both groups, all examinations were performed using unenhanced technique with tin prefiltration between June 2022 and January 2023. Patients were matched between groups using age, sex, and BMI. A custom gaussian curve-fitting algorithm was used to automatically calculate image noise, SNR, and CNR for each examination, on the basis of all voxels within the image set. Three radiologists independently reviewed examinations to perform a subjective visual assessment of visualization of trabecular architecture, cortical bone, neuroforaminal content, paraspinal muscles, and intervertebral disk, as well as overall image quality, using a 4-point Likert scale (1 = poor, 4 = excellent). PCD CT and EID CT examinations were compared. RESULTS. Mean CTDIvol was 4.4 ± 1.0 (SD) mGy for PCD CT versus 11.1 ± 1.9 mGy for EID CT (p < .001). Mean size-specific dose estimate (SSDE) was 6.2 ± 1.0 (SD) mGy for PCD CT versus 14.2 ± 1.8 mGy for EID CT (p < .001). PCD CT and EID CT examinations were not significantly different in terms of image noise or SNR (both p > .05). PCD CT, in comparison with EID CT, showed significantly higher CNR (mean ± SD, 33.6 ± 3.3 vs 29.3 ± 4.1; p < .001). For all three readers, the median score for overall image quality was 4 (range, 3-4) for both PCD CT and EID CT. PCD CT and EID CT examinations showed no significant difference in terms of any qualitative measure for any reader (all p > .05). CONCLUSION. PCD CT, in comparison with EID CT, yielded significantly lower radiation dose with preserved image quality. CLINICAL IMPACT. The findings support expanded use of PCD CT for lumbar spine evaluation.


Assuntos
Fótons , Estanho , Masculino , Humanos , Feminino , Adulto , Estudos Prospectivos , Estudos Retrospectivos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
5.
AJR Am J Roentgenol ; 222(1): e2329765, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37646387

RESUMO

BACKGROUND. Photon-counting detector (PCD) CT may allow lower radiation doses than used for conventional energy-integrating detector (EID) CT, with preserved image quality. OBJECTIVE. The purpose of this study was to compare PCD CT and EID CT, reconstructed with and without a denoising tool, in terms of image quality of the osseous pelvis in a phantom, with attention to low radiation doses. METHODS. A pelvic phantom comprising human bones in acrylic material mimicking soft tissue underwent PCD CT and EID CT at various tube potentials and radiation doses ranging from 0.05 to 5.00 mGy. Additional denoised reconstructions were generated using a commercial tool. Noise was measured in the acrylic material. Two readers performed independent qualitative assessments that entailed determining the denoised EID CT reconstruction with the lowest acceptable dose and then comparing this reference reconstruction with PCD CT reconstructions without and with denoising, using subjective Likert scales. RESULTS. Noise was lower for PCD CT than for EID CT. For instance, at 0.05 mGy and 100 kV with tin filter, noise was 38.4 HU for PCD CT versus 48.8 HU for EID CT. Denoising further reduced noise; for example, for PCD CT at 100 kV with tin filter at 0.25 mGy, noise was 19.9 HU without denoising versus 9.7 HU with denoising. For both readers, lowest acceptable dose for EID CT was 0.10 mGy (total score, 11 of 15 for both readers). Both readers somewhat agreed that PCD CT without denoising at 0.10 mGy (reflecting reference reconstruction dose) was relatively better than the reference reconstruction in terms of osseous structures, artifacts, and image quality. Both readers also somewhat agreed that denoised PCD CT reconstructions at 0.10 mGy and 0.05 mGy (reflecting matched and lower doses, respectively, with respect to reference reconstruction dose) were relatively better than the reference reconstruction for the image quality measures. CONCLUSION. PCD CT showed better-quality images than EID CT when performed at the lowest acceptable radiation dose for EID CT. PCD CT with denoising yielded better-quality images at a dose lower than lowest acceptable dose for EID CT. CLINICAL IMPACT. PCD CT with denoising could facilitate lower radiation doses for pelvic imaging.


Assuntos
Fótons , Estanho , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Doses de Radiação , Pelve
6.
Semin Musculoskelet Radiol ; 28(3): 282-292, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38768593

RESUMO

The prevalence of total knee arthroplasty (TKA) is increasing with the aging population. Although long-term results are satisfactory, suspected postoperative complications often require imaging with the implant in place. Advancements in computed tomography (CT), such as tin prefiltration, metal artifact reduction algorithms, dual-energy CT with virtual monoenergetic imaging postprocessing, and the application of cone-beam CT and photon-counting detector CT, allow a better depiction of the tissues adjacent to the metal. For magnetic resonance imaging (MRI), high bandwidth (BW) optimization, the combination of view angle tilting and high BW, as well as multispectral imaging techniques with multiacquisition variable-resonance image combination or slice encoding metal artifact correction, have significantly improved imaging around metal implants, turning MRI into a useful clinical tool for patients with suspected TKA complications.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Prótese do Joelho , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tomografia Computadorizada por Raios X/métodos
7.
Skeletal Radiol ; 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381196

RESUMO

Magnetic resonance imaging (MRI) around metal implants has been challenging due to magnetic susceptibility differences between metal implants and adjacent tissues, resulting in image signal loss, geometric distortion, and loss of fat suppression. These artifacts can compromise the diagnostic accuracy and the evaluation of surrounding anatomical structures. As the prevalence of total joint replacements continues to increase in our aging society, there is a need for proper radiological assessment of tissues around metal implants to aid clinical decision-making in the management of post-operative complaints and complications. Various techniques for reducing metal artifacts in musculoskeletal imaging have been explored in recent years. One approach focuses on improving hardware components. High-density multi-channel radiofrequency (RF) coils, parallel imaging techniques, and gradient warping correction enable signal enhancement, image acquisition acceleration, and geometric distortion minimization. In addition, the use of susceptibility-matched implants and low-field MRI helps to reduce magnetic susceptibility differences. The second approach focuses on metal artifact reduction sequences such as view-angle tilting (VAT) and slice-encoding for metal artifact correction (SEMAC). Iterative reconstruction algorithms, deep learning approaches, and post-processing techniques are used to estimate and correct artifact-related errors in reconstructed images. This article reviews recent developments in clinically applicable metal artifact reduction techniques as well as advances in MR hardware. The review provides a better understanding of the basic principles and techniques, as well as an awareness of their limitations, allowing for a more reasoned application of these methods in clinical settings.

8.
Skeletal Radiol ; 53(4): 665-673, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37804455

RESUMO

OBJECTIVE: To compare the image quality of low-dose CT (LD-CT) with tin filtration of the lumbar spine after metal implants to standard clinical CT, and to evaluate the potential for metal artifact and dose reduction. MATERIALS AND METHODS: CT protocols were optimized in a cadaver torso. Seventy-four prospectively included patients with metallic lumbar implants were scanned with both standard CT (120 kV) and tin-filtered LD-CT (Sn140kV). CT dose parameters and qualitative measures (1 = worst,4 = best) were compared. Quantitative measures included noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and the width and attenuation of the most prominent hypodense metal artifact. Standard CT and LD-CT were assessed for imaging findings. RESULTS: Tin-filtered LD-CT was performed with 60% dose saving compared to standard CT (median effective dose 3.22 mSv (quartile 1-3: 2.73-3.49 mSv) versus 8.02 mSv (6.42-9.27 mSv; p < .001). Image quality of CT and tin-filtered low-dose CT was good with excellent depiction of anatomy, while image noise was lower for CT and artifacts were weaker for tin-filtered LD-CT. Quantitative measures also revealed increased noise for tin-filtered low-dose CT (41.5HU), lower SNR (2) and CNR (0.6) compared to CT (32HU,3.55,1.03, respectively) (all p < .001). However, tin-filtered LD-CT performed superior regarding the width and attenuation of hypodense metal artifacts (2.9 mm and -767.5HU for LD-CT vs. 4.1 mm and -937HU for CT; all p < .001). No difference between methods was observed in detection of imaging findings. CONCLUSION: Tin-filtered LD-CT with 60% dose saving performs comparable to standard CT in detection of pathology and surgery related complications after lumbar spinal instrumentation, and shows superior metal artifact reduction.


Assuntos
Estanho , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Tomografia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
9.
Skeletal Radiol ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512363

RESUMO

OBJECTIVES: Knowledge about the long-term outcome of patients with lumbar spondylolysis (LS) is limited. This study assessed the frequency of bone fusion in conservatively treated lumbar spondylolysis with photon counting detector computed tomography. METHODS: Patients with lumbar spondylolysis diagnosed with CT or MRI were prospectively enrolled and underwent CT 5-10 years after initial imaging. Image assessment included evaluation of Meyerding grade, listhesis size, measurement of the lysis gap, and disc integrity on the lysis level. Comparisons were made between bone fusion as the primary endpoint and sex, body mass index, age at diagnosis, follow-up interval, size of listhesis, Meyerding grade, size of the lysis gap, sports activity, and presence of pain. RESULTS: A total of 39 patients (26.0 ± 3.1 years, 15 female) with lumbar spondylolysis on 41 levels were included after a mean follow-up period of 9.1 ± 2.2 years. Nine patients (22.0%, four female) showed complete fusion of the lysis gap. Patients with bone fusion of the lysis gap had a significantly lower Meyerding grade (p = 0.01), smaller size of the listhesis (p = 0.019), and smaller anterior and posterior lysis gap size (p = 0.046 and p = 0.011, respectively). Unilateral lyses showed significantly higher fusion rates than bilateral lyses (40.0% vs. 16.1%, p = 0.01). No statistically significant difference was found for pain at follow-up between patients with and without bone fusion (p = 0.253). CONCLUSION: Bone fusion occurred in about a fifth of conservatively treated lumbar spondylolysis after a follow-up period of 9 years. Factors associated with a successful fusion were a lower Meyerding grade, minimal listhesis, and a small lysis gap.

10.
Eur Radiol ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37947837

RESUMO

OBJECTIVES: We evaluated the relationship between femoral anteversion (FA), FA change, and ischiofemoral impingement (IFI) and the relationship between FA, femoral offset (FO), and greater trochanteric pain syndrome (GTPS) after total hip arthroplasty (THA). MATERIALS AND METHODS: In this retrospective study, two readers assessed FA and FO on CT images of 197 patients following primary THA with an anterior surgical approach between 2014 and 2021. FA change was calculated relative to preoperative CT, while FO change was calculated relative to preoperative radiographs and classified as decreased (≥-5 mm), increased (≥ + 5 mm), or restored (± 5 mm). Clinical and imaging data were analyzed for IFI and GTPS after surgery. Group differences were evaluated using Student's t-test, chi-square analysis, and receiver operating characteristic (ROC) analysis. RESULTS: The change in FA was 3.6 ± 3.3° to a postoperative FA of 22.5 ± 6.8°, while FO increased by 1.7 ± 3.5 mm to a postoperative FO of 42.9 ± 7.1 mm. FA and FA change were higher in patients with IFI (p ≤ 0.006), while no significant difference was observed for patients with and without GTPS (p ≥ 0.122). IFI was more common in females (p = 0.023). In the ROC analysis, an AUC of 0.859 was observed for FA change to predict IFI, whereas the AUC value was 0.726 for FA alone. No significant difference was found for FO change in patients with and without IFI or GTPS (p ≥ 0.187). CONCLUSION: Postoperative FA, FA change, and female sex were associated with IFI after anterior-approached THA. The change in FA was a better predictor of IFI than absolute postoperative FA alone. CLINICAL RELEVANCE STATEMENT: The findings of this study suggest that preservation of the preoperative femoral anteversion may reduce postoperative ischiofemoral impingement in patients undergoing total hip arthroplasty. KEY POINTS: • Higher postoperative femoral anteversion and anteversion change were associated with ischiofemoral impingement. • Femoral anteversion change was a better predictor of impingement than absolute postoperative anteversion. • No significant association was found between femoral offset and postoperative hip pain.

11.
Eur Radiol ; 33(5): 3188-3199, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36576545

RESUMO

OBJECTIVES: The aim is to validate the performance of a deep convolutional neural network (DCNN) for vertebral body measurements and insufficiency fracture detection on lumbar spine MRI. METHODS: This retrospective analysis included 1000 vertebral bodies in 200 patients (age 75.2 ± 9.8 years) who underwent lumbar spine MRI at multiple institutions. 160/200 patients had ≥ one vertebral body insufficiency fracture, 40/200 had no fracture. The performance of the DCNN and that of two fellowship-trained musculoskeletal radiologists in vertebral body measurements (anterior/posterior height, extent of endplate concavity, vertebral angle) and evaluation for insufficiency fractures were compared. Statistics included (a) interobserver reliability metrics using intraclass correlation coefficient (ICC), kappa statistics, and Bland-Altman analysis, and (b) diagnostic performance metrics (sensitivity, specificity, accuracy). A statistically significant difference was accepted if the 95% confidence intervals did not overlap. RESULTS: The inter-reader agreement between radiologists and the DCNN was excellent for vertebral body measurements, with ICC values of > 0.94 for anterior and posterior vertebral height and vertebral angle, and good to excellent for superior and inferior endplate concavity with ICC values of 0.79-0.85. The performance of the DCNN in fracture detection yielded a sensitivity of 0.941 (0.903-0.968), specificity of 0.969 (0.954-0.980), and accuracy of 0.962 (0.948-0.973). The diagnostic performance of the DCNN was independent of the radiological institution (accuracy 0.964 vs. 0.960), type of MRI scanner (accuracy 0.957 vs. 0.964), and magnetic field strength (accuracy 0.966 vs. 0.957). CONCLUSIONS: A DCNN can achieve high diagnostic performance in vertebral body measurements and insufficiency fracture detection on heterogeneous lumbar spine MRI. KEY POINTS: • A DCNN has the potential for high diagnostic performance in measuring vertebral bodies and detecting insufficiency fractures of the lumbar spine.


Assuntos
Fraturas de Estresse , Fraturas da Coluna Vertebral , Humanos , Idoso , Idoso de 80 Anos ou mais , Corpo Vertebral , Estudos Retrospectivos , Reprodutibilidade dos Testes , Vértebras Torácicas/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética , Redes Neurais de Computação
12.
Eur Radiol ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37855854

RESUMO

OBJECTIVES: This study aimed to evaluate the diagnostic accuracy, inter-reader agreement, and associated pathologies on MR images of patients with confirmed TC. METHODS AND MATERIALS: In this retrospective study, 168 ankle MRI exams were included, consisting of 56 patients with clinically or surgically confirmed TC and 112 controls without TC, matched for age and sex. Images were analyzed independently by three radiologists blinded to clinical information. The evaluation criteria included the presence, type, and location of TC, as well as associated pathologies. After calculating diagnostic accuracy and the odds ratio of demographic data and anatomic coalition type for associated pathologies, inter-reader agreement was assessed using kappa statistics. RESULTS: The majority of TCs were non-osseous (91.1%) and located at the calcaneonavicular (33.9%) or talocalcaneal joint (66.1%). Associated pathologies included adjacent and distant bone marrow edema (57.1% and 25.0%), osteochondral defect of the talar dome (OCD, 19.6%), and joint effusion (10.7%) and accessory anterolateral talar facet (17.9%). Talar OCD was associated with increased patient age (p = 0.03). MRI exhibited a cumulative sensitivity and specificity of 95.8% and 94.3% with almost perfect inter-reader agreement (κ = 0.895). CONCLUSION: MRI is a reliable method for detecting tarsal coalition and identifying commonly associated pathologies. Therefore, we recommend the routine use of MRI in the diagnostic workup of patients with foot pain and suspected tarsal coalition. CLINICAL RELEVANCE STATEMENT: MRI is an accurate and reliable modality for diagnosing tarsal coalitions and detecting associated pathologies, while improving patient safety compared to computed tomography by avoiding radiation exposure. KEY POINTS: • Despite the technological progress in magnetic resonance imaging (MRI), computed tomography (CT) is still regarded as the gold standard for diagnosing tarsal coalition (TC). • MRI had a cumulative sensitivity of 95.8% and specificity of 94.3% for detecting tarsal coalition with an almost perfect inter-reader agreement. • MRI demonstrates high accuracy and reliability in diagnosing tarsal coalitions and is useful for identifying associated pathologies, while also improving patient safety by avoiding radiation exposure.

13.
Semin Musculoskelet Radiol ; 27(2): 163-168, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37011617

RESUMO

The elbow is a synovial joint able to perform flexion, extension, supination, and pronation. Knowledge of anatomical variants is crucial to avoid misinterpretation during the evaluation of the elbow joint. We address those anatomical variants simulating pathologic conditions.


Assuntos
Articulação do Cotovelo , Humanos , Articulação do Cotovelo/diagnóstico por imagem , Cotovelo/diagnóstico por imagem , Articulações , Amplitude de Movimento Articular , Pronação
14.
Eur Spine J ; 32(1): 8-19, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35835893

RESUMO

PURPOSE: Abdominal aortic aneurysms (AAAs) affect the vascular perfusion of the lumbar spine. The treatment of AAAs with endovascular aortic aneurysm repair (EVAR) completely occludes the direct vascular supply to the lumbar spine. We hypothesized that patients with AAA who undergo EVAR show a different pattern of spinal degeneration than individuals without AAA. METHODS: In this retrospective institutional review board-approved study, 100 randomly selected patients with AAA who underwent EVAR with computed tomography (CT) scans between 2005 and 2017 were compared with age- and gender-matched controls without AAA. In addition, long-term follow-up CT images (> 6 months before EVAR, at the time of EVAR, and > 12 months after EVAR) of the patients were analysed to compare the progression of degeneration from before to after EVAR. Degeneration scores, lumbar levels with the most severe degeneration, and lumbar levels with progressive degeneration were analysed in all CT images. Fisher's exact test, Wilcoxon signed-rank test, and Mann-Whitney U test were performed for statistical analyses. RESULTS: Compared with the control group (n = 94), the most severe degeneration was more commonly detected in the mid-lumbar area in the patient group (n = 100, p = 0.016), with significantly more endplate erosions being detected in the lumbar spine (p = 0.015). However, EVAR did not result in significant additional acceleration of the degenerative process in the long-term follow-up analysis (n = 51). CONCLUSION: AAA is associated with atypical, more cranially located spinal degradation, particularly in the mid-lumbar segments; however, EVAR does not seem to additionally accelerate the degenerative process. This observation underlines the importance of disc and endplate vascularization in the pathomechanism of spinal degeneration. LEVEL OF EVIDENCE I: Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Humanos , Estudos Retrospectivos , Estudos Transversais , Procedimentos Cirúrgicos Vasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Aneurisma da Aorta Abdominal/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Fatores de Risco
15.
Skeletal Radiol ; 52(10): 1853-1862, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36149474

RESUMO

Back pain is one of the most common medical problems and is associated with high socioeconomic costs. Imaging-guided spinal injections are a minimally invasive method to evaluate where the back pain is originating from, and to treat patients with radicular pain or spinal stenosis with infiltration of corticosteroids. CT-guided spine injections are a safe procedure, characterized by precise needle placement, excellent visualization of the relevant anatomical structures, and low radiation exposure for the patient and the interventional radiologist. In this review article, the variety of applications of CT-guided injections (focused on nerve roots and epidural injections) and the optimal injection procedure as well as risks and side effects are discussed.


Assuntos
Bloqueio Nervoso , Estenose Espinal , Humanos , Dor nas Costas/tratamento farmacológico , Bloqueio Nervoso/métodos , Injeções Epidurais/métodos , Tomografia Computadorizada por Raios X
16.
Skeletal Radiol ; 52(2): 183-191, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36002755

RESUMO

OBJECTIVE: De-centering of the shoulder joint on radiographs is used as indicator for severity of rotator cuff tears and as predictor for clinical outcome after surgery. The objective of the study was to assess the effect of malrotation on glenohumeral centering on radiographs and to identify the most reliable parameter for its quantification. SUBJECTS AND METHODS: In this retrospective study (2014-2018), 249 shoulders were included: 92 with imaging-confirmed supra- and infraspinatus tears (rupture; 65.2 ± 9.9 years) and 157 without tears (control; 41.1 ± 13.0 years). On radiographs in neutral position and external rotation, we assessed three radiographic parameters to quantify glenohumeral centering: acromiohumeral distance (ACHD), craniocaudal distance of the humeral head and glenoid center (Deutsch), and scapulohumeral arch congruity (Moloney). Non-parametric statistics was performed. RESULTS: In both positions, only the distance parameters ACHD (< 0.5 mm) and Deutsch (< 1 mm) were comparable in the two study groups rupture and control. Comparing the parameters between the study groups revealed only ACHD to be significantly different with a reduction of more than 2 mm in the rupture group. Among the parameters, ACHD ≤ 6 mm was the only cut-off discriminating rupture (12-21% of the shoulders with ACHD ≤ 6 mm) and control (none of the shoulders with ACHD ≤ 6 mm). Ninety percent of shoulders with ACHD ≤ 6 mm presented with a massive rotator cuff tear (defined as ≥ 67% of the greater tuberosity exposed). CONCLUSION: Glenohumeral centering assessed by ACHD and Deutsch is not affected by rotation in shoulders with and without rotator cuff tear. An ACHD ≤ 6 mm has a positive predictive value of 90% for a massive rotator cuff tear.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Ombro , Estudos Retrospectivos , Amplitude de Movimento Articular , Manguito Rotador/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Ruptura
17.
Skeletal Radiol ; 52(9): 1661-1668, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36997748

RESUMO

PURPOSE: To evaluate the distribution and severity of muscle atrophy in diabetic patients with active Charcot foot (CF) compared to diabetic patients without CF. Furthermore, to correlate the muscle atrophy with severity of CF disease. MATERIAL/METHODS: In this retrospective study, MR images of 35 diabetic patients (21 male, median:62.1 years ± 9.9SD) with active CF were compared with an age- and gender-matched control group of diabetic patients without CF. Two readers evaluated fatty muscle infiltration (Goutallier-classification) in the mid- and hindfoot. Furthermore, muscle trophic (cross-sectional muscle area (CSA)), intramuscular edema (none/mild versus moderate/severe), and the severity of CF disease (Balgrist Score) were assessed. RESULTS: Interreader correlation for fatty infiltration was substantial to almost perfect (kappa-values:0.73-1.0). Frequency of fatty muscle infiltration was high in both groups (CF:97.1-100%; control:77.1-91.4%), but severe infiltration was significantly more frequent in CF patients (p-values: < 0.001-0.043). Muscle edema was also frequently seen in both groups, but significantly more often in the CF group (p-values: < 0.001-0.003). CSAs of hindfoot muscles were significantly smaller in the CF group. For the flexor digitorum brevis muscle, a cutoff value of 139 mm2 (sensitivity:62.9%; specificity:82.9%) in the hindfoot was found to differentiate between CF disease and the control group. No correlation was seen between fatty muscle infiltration and the Balgrist Score. CONCLUSION: Muscle atrophy and muscle edema are significantly more severe in diabetic patients with CF disease. Muscle atrophy does not correlate with the severity of active CF disease. A CSA < 139 mm2 of the flexor digitorum brevis muscle in the hindfoot may indicate CF disease.


Assuntos
Diabetes Mellitus , Pé Diabético , Doenças do Pé , Humanos , Masculino , Estudos de Casos e Controles , Estudos Retrospectivos , Estudos Transversais , Atrofia Muscular/diagnóstico por imagem , Edema , Imageamento por Ressonância Magnética
18.
Arch Orthop Trauma Surg ; 143(6): 2965-2971, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35767038

RESUMO

BACKGROUND: The anteroposterior (ap) radiograph of the pelvis is decisive in the diagnosis of different pathologies of the hip joint. Technical advantages have reduced the radiation dose of pelvic CT to levels comparable to radiographs. The purpose of this study was to validate if standard radiographic parameters (lateral center edge angle, medial center edge angle, acetabular index, acetabular arc, extrusion index, crossover sign and posterior wall sign) can accurately be determined on radiograph-like projections reconstructed from the CT dataset pre- and postoperatively. METHODS: A consecutive series of patient with symptomatic dysplasia of the hip and a full radiologic workup (radiographs and CT scan pre- and postoperatively) who underwent periacetabular osteotomy were included. Standard radiographic parameters were compared between radiographs and radiograph-like projections by two authors pre- and postoperatively. RESULTS: A total of 16 hips (32 radiographs/32 radiograph-like projections) were included in the study. No significant difference was found between the radiographs and radiograph-like images for all parameter for both examiners. ICC between radiograph and radiograph-like projections for all investigated parameters showed good to excellent reliability (0.78-0.99) pre- and postoperatively. CONCLUSION: Radiograph-like projections show comparable results to radiographs with regard to the important investigated parameters (lateral center edge angle, medial center edge angle, acetabular index, acetabular arc, extrusion index, crossover sign and posterior wall sign). Thus, ultra-low-dose CT scans may reduce the need for conventional radiographs in pre- and postoperative analyses of 3-dimensional hip pathologies in the future, as the advantages increasingly outweigh the disadvantages.


Assuntos
Acetábulo , Articulação do Quadril , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/patologia , Pelve , Tomografia Computadorizada por Raios X
19.
Arch Orthop Trauma Surg ; 143(8): 5345-5352, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36460762

RESUMO

BACKGROUND: Inaccurately scaled radiographs for total hip arthroplasty (THA) templating are a source of error not recognizable to the surgeon and may lead to inaccurate reconstruction and thus revision surgery or litigation. Planning based on computed tomography (CT) scans is more accurate but associated with higher radiation exposure. The aim of this study was (1) to retrospectively assess the scaling deviation of pelvic radiographs; (2) to prospectively assess the feasibility and the radiation dose of THA templating on radiograph-like images reconstructed from a tin-filtered ultra-low-dose CT dataset. METHODS: 120 consecutive patients were retrospectively analyzed to assess the magnification error of our current THA templates. 27 consecutive patients were prospectively enrolled and a radiographic work-up in the supine position including a new tin-filtered ultra-low-dose CT scan protocol was obtained. THA was templated on both images. Radiation dose was calculated. RESULTS: Scaling deviations between preoperative radiographs and CT of ≥ 5% were seen in 25% of the 120 retrospectively analyzed patients. Between the two templates trochanter tip distance differed significantly (Δ2.4 mm, 0-7 mm, p = 0.035)), predicted femoral shaft size/cup size was the same in 45%/41%. The radiation dose of the CT (0.58 mSv, range 0.53-0.64) was remarkably low. CONCLUSION: Scaling deviations of pelvic radiographs for templating THA may lead to planning errors of ≥ 3 mm in 25% and ≥ 6 mm in 2% of the patients. 2-D templating on radiograph-like images based on tin-filtered ultra-low-dose CT eliminates this source of error without increased radiation dose. LEVEL OF EVIDENCE: Retrospective and prospective comparative study, Level III.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos , Doses de Radiação , Estudos Retrospectivos , Estanho , Tomografia Computadorizada por Raios X/métodos
20.
Radiology ; 304(2): 363-369, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35536136

RESUMO

Background Intraarticular corticosteroid (IACS) injections are frequently performed for hip and knee osteoarthritis (OA); however, there are conflicting data about the benefits and complications of IACS injections and a lack of large studies with follow-up. Purpose To determine the number of patients with complications after hip and knee IACS injections in a large study sample with long-term follow-up. Materials and Methods This retrospective single-center case series included patients who received a corticosteroid injection in the hip (n = 500) or knee (n = 500) and who underwent clinical and radiologic follow-up (conventional radiography, fluoroscopy, CT, or MRI) between 1 and 12 months after injection (January 2016 to May 2020). General descriptive statistics and the χ2 test were applied. P < .05 was indicative of a significant difference. Results Of the 1000 patients (mean age, 57 years ± 16 [SD]; 545 women), 10 patients (1%) developed severe complications. Four patients developed osteonecrosis; three, insufficiency fractures; and three, rapid progressive OA. All 10 complications occurred between 2 and 9 months after injection: six (60%) in the hip and four (40%) in the knee. Of the included 1000 patients, 545 (54%) were women, but they had nine of the 10 (90%) complications (P = .02). Conclusion Intraarticular steroid injection had a substantially lower complication rate than that reported in previous smaller studies. The rate of severe complications was disproportionally higher in women than in men. © RSNA, 2022 See also the editorial by Jennings in this issue.


Assuntos
Osteoartrite do Quadril , Osteoartrite do Joelho , Corticosteroides/efeitos adversos , Feminino , Fluoroscopia , Humanos , Injeções Intra-Articulares , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/tratamento farmacológico , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/tratamento farmacológico , Estudos Retrospectivos , Esteroides , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA