Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 19(2): 329-337, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29368796

RESUMO

The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) held a comparison exercise in April 2016 where participants came to ARPANSA and measured the output factor of a nominal 5 mm cone attached to the ARPANSA Elekta Synergy (Elekta, Crawley, UK) linear accelerator. The goal of the exercise was to compare the consistency and methods used by independent medical physicists in measuring small-field output factors. ARPANSA provided a three-dimensional scanning tank for detector setup and positioning, but the participants were required to measure the output factor with their own detectors. No information regarding output factors previously measured was supplied to participants to make each result as independent as possible. Fifteen groups travelled to ARPANSA bringing a wide range of detectors and methods. A total of 30 measurements of the output factor were made. The standard deviation of the measurements (excluding one expected outlier from an uncorrected ionization chamber measurement) was 3.6%. The results provide an insight into the consistency of small-field dosimetry being performed in Australia and New Zealand at the present time.


Assuntos
Aceleradores de Partículas/normas , Proteção Radiológica , Radiometria/métodos , Radiometria/normas , Humanos , Doses de Radiação , Inquéritos e Questionários
2.
Australas Phys Eng Sci Med ; 38(2): 325-30, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25749989

RESUMO

The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) maintains a (60)Co teletherapy source primarily for the calibration of therapy dosemeters. The source and encapsulating head were replaced in early 2010 with an Eldorado 78 head and new (60)Co source. In this article we present the results of ongoing accuracy and stability measurements since the replacement. A number of formal and informal indirect comparisons have been carried out with laboratories holding primary and secondary standards for (60)Co. ARPANSA chambers have also been calibrated at international primary standard laboratories allowing comparison of calibration coefficients and thus (60)Co absorbed dose standards. (60)Co calibration coefficients supplied by manufacturers of chambers were compared to those measured at the ARPANSA when this calibration was traceable to a primary standard. ARPANSA also participates in an annual international mailed dosimetry audit conducted by the International Atomic Energy Agency. The results thus far demonstrate that the absorbed doses to water delivered by the new ARPANSA (60)Co source are consistent with international doses within the stated uncertainties.


Assuntos
Radioisótopos de Cobalto/análise , Radiometria/métodos , Radiometria/normas , Austrália , Calibragem , Auditoria Clínica , Internacionalidade , Sociedades Científicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA