1.
Endoscopy ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38408594

RESUMO

BACKGROUND: The pocket-creation method (PCM) was developed to overcome the technical difficulties of endoscopic submucosal dissection (ESD), although opening the pocket remains challenging. We developed a novel technique of PCM with single-clip traction (PCM-CT), which uses a reopenable clip as a traction device to maintain stability during the procedure. No prospective study has compared the efficacy of PCM-CT and PCM. This study aimed to investigate the effectiveness of PCM-CT vs. PCM in a randomized controlled trial. METHODS: This randomized controlled clinical trial was conducted at four Japanese institutions. Patients with superficial colorectal neoplastic lesions were included following Japanese guidelines for colorectal cancer. Seven moderately experienced endoscopists performed the ESD procedures using either PCM-CT or PCM. RESULTS: 100 patients were enrolled in the study. Compared with PCM, PCM-CT achieved significantly faster mean (SD) dissection speed (21.4 [10.8] vs. 27.0 [14.5] mm2/min [95%CI 0.5 to 10.7], P = 0.03), and reduced the mean procedure time (81.8 [57.9] vs. 64.8 [47.6] minutes [95%CI -38.2 to 4.3], P = 0.12) and pocket-opening time (37.8 [33.0] vs. 30.0 [28.9] minutes [95%CI -20.2 to 4.6], P = 0.22). En bloc and R0 resection rates were not significantly different between the two groups (100% vs. 100%, P >0.99; 100% vs. 96%, P = 0.50, respectively). No significant differences were observed in adverse events between the two groups. CONCLUSION: ESD facilitated by the novel PCM-CT method appeared to be significantly faster than PCM. Both methods achieved high R0 resection rates.

2.
Endoscopy ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38857619

RESUMO

BACKGROUND: Sessile serrated lesions (SSLs) are associated with an increased risk of colorectal cancer. Data on the prevalence of SSLs in Asia are limited. We performed this study to estimate the prevalence of SSLs in Asia and to explore endoscopic factors that are associated with SSL detection. METHODS: This is a post-hoc analysis of a multicenter randomized controlled trial from four Asian countries/regions that compared adenoma detection rates using linked-color imaging (LCI) and white-light imaging. Colonoscopies were performed in an average-risk population for screening, diagnostic examination, or polyp surveillance. Patients with SSLs were compared against those without SSLs to evaluate for possible predictors of SSL detection using Firth's logistic regression. RESULTS: 2898 participants (mean age 64.5 years) were included in the analysis. The estimated prevalence of SSLs was 4.0% (95%CI 3.4%-4.8%), with no sex or age group differences. On multivariable analysis, use of LCI (adjusted odds ratio [aOR] 1.63, 95%CI 1.10-2.41), experienced endoscopists (aOR 1.94, 95%CI 1.25-3.00), use of transparent cap (aOR 1.75, 95%CI 1.09-2.81), and longer withdrawal time (aOR 1.06, 95%CI 1.03-1.10) were independently associated with SSL detection. Synchronous adenoma detection (aOR 1.89, 95%CI 1.20-2.99) was also predictive of SSL detection. CONCLUSION: The prevalence of SSLs in Asia is 4.0%. Use of LCI or a transparent cap, greater endoscopist experience, and longer withdrawal time were all associated with increased SSL detection.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38602345

RESUMO

BACKGROUND AND AIM: Linked color imaging (LCI) is an image-enhanced endoscopy technique that accentuates the color difference between red and white, potentially improving the adenoma detection rate (ADR). However, it remains unclear whether LCI performance in detecting colorectal lesions differs based on endoscopists' experience levels. We aimed to evaluate the differences in LCI efficacy based on the experience levels of endoscopists by conducting an exploratory analysis. METHODS: In this post hoc analysis of an international randomized controlled trial comparing the detection of adenoma and other lesions using colonoscopy with LCI and high-definition white light imaging (WLI), we included patients from 11 institutions across four countries/regions: Japan, Thailand, Taiwan, and Singapore. We retrospectively reviewed differences in the lesion detection of LCI according to endoscopists' colonoscopy history or ADR. RESULTS: We included 1692 and 1138 patients who underwent colonoscopies performed by 54 experts (experience of ≥ 5000 colonoscopies) and by 43 non-experts (experience of < 5000 colonoscopies), respectively. Both expert and non-expert groups showed a significant improvement in ADR with LCI compared to WLI (expert, 61.7% vs 46.4%; P < 0.001; non-expert, 56.6% vs 46.4%; P < 0.001). LCI had no effect on sessile serrated lesion detection rate in non-experts (3.1% vs 2.5%; P = 0.518). LCI significantly improved detection rates in endoscopists with relatively low detection performance, defined as an ADR < 50%. CONCLUSIONS: This exploratory study analyzed data from a previous trial and revealed that LCI is useful for both experts and non-experts and is even more beneficial for endoscopists with relatively low detection performance using WLI.

4.
Digestion ; : 1-11, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38631318

RESUMO

INTRODUCTION: We investigated coexisting lesion types in patients with invasive colorectal cancer (CRC) in a multinational study for comprehending the adenoma-carcinoma and serrated pathway about the development of CRC. METHODS: We retrospectively reviewed 3,050 patients enrolled in the international randomized controlled trial (ATLAS study) to evaluate the colorectal polyp detection performance of image-enhanced endoscopy in 11 institutions in four Asian countries/regions. In the current study, as a subgroup analysis of the ATLAS study, 92 CRC patients were extracted and compared to 2,958 patients without CRC to examine the effects of age, sex, and coexisting lesion types (high-grade adenoma [HGA], low-grade adenoma with villous component [LGAV], 10 adenomas, adenoma ≥10 mm, sessile serrated lesions [SSLs], and SSLs with dysplasia [SSLD]). Additional analyses of coexisting lesion types were performed according to sex and location of CRC (right- or left-sided). RESULTS: A multivariate analysis showed that HGA (odds ratio [95% confidence interval] 4.29 [2.16-8.18]; p < 0.01), LGAV (3.02 [1.16-7.83], p = 0.02), and age (1.04 [1.01-1.06], p = 0.01) were independently associated with CRC. According to sex, the coexisting lesion types significantly associated with CRC were LGAV (5.58 [1.94-16.0], p < 0.01) and HGA (4.46 [1.95-10.20], p < 0.01) in males and HGA (4.82 [1.47-15.80], p < 0.01) in females. Regarding the location of CRC, SSLD (21.9 [1.31-365.0], p = 0.03) was significant for right-sided CRC, and HGA (5.22 [2.39-11.4], p < 0.01) and LGAV (3.46 [1.13-10.6], p = 0.02) were significant for left-sided CRC. CONCLUSIONS: The significant coexisting lesions in CRC differed according to sex and location. These findings may contribute to comprehending the pathogenesis of CRC.

5.
Clin Gastroenterol Hepatol ; 21(6): 1493-1502.e4, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36328306

RESUMO

BACKGROUND & AIMS: Effects of linked-color imaging (LCI) on colorectal lesion detection and colonoscopy quality remain controversial. This study compared the detection rates of adenoma and other precursor lesions using LCI vs white-light imaging (WLI) during screening, diagnostic, and surveillance colonoscopies. METHODS: This randomized controlled trial was performed at 11 institutions in 4 Asian countries/regions. Patients with abdominal symptoms, a primary screening colonoscopy, positive fecal immunochemical test results, or undergoing postpolypectomy surveillance were recruited and randomly assigned in a 1:1 ratio to either the LCI or high-definition WLI group. The primary outcome was adenoma detection rate (ADR). Secondary outcomes were polyp detection rate, advanced ADR, sessile serrated lesion (SSL) detection rate, and the mean number of adenomas per colonoscopy. The recommended surveillance schedule distribution after trial colonoscopy was analyzed. RESULTS: Between November 2020 and January 2022, there were 3050 participants (LCI, n = 1527; WLI, n = 1523) recruited. The LCI group ADR was significantly higher than the WLI group ADR using intention-to-treat (58.7% vs 46.7%; P < .01) and per-protocol analyses (59.6% vs 46.4%; P < .01). The LCI group polyp detection rates (68.6% vs 59.5%; P < .01), SSL detection rates (4.8% vs 2.8%; P < .01), and adenomas per colonoscopy (1.48 vs 1.02; P < .01) also were significantly higher. However, the advanced ADR was not significantly different (13.2% vs 11.0%; P = .06). Significantly more patients in the LCI group had shorter recommended surveillance schedules than the WLI group (P < .01). CONCLUSIONS: Compared with WLI, LCI improved adenoma and other polyp detection rates, including SSLs, resulting in alteration of the recommended surveillance schedule after screening, diagnostic, and postpolypectomy surveillance colonoscopies. TRIAL REGISTRATION NUMBER: UMIN000042432 (https://www.umin.ac.jp/ctr/index.htm).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Pólipos , Humanos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Colonoscopia/métodos , Adenoma/diagnóstico , Adenoma/patologia , Pólipos/diagnóstico , Diagnóstico por Imagem , Pólipos do Colo/diagnóstico
6.
Gastrointest Endosc ; 98(1): 90-99.e4, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36738793

RESUMO

BACKGROUND AND AIMS: Differentiation of colorectal cancers (CRCs) with deep submucosal invasion (T1b) from CRCs with superficial invasion (T1a) or no invasion (Tis) is not straightforward. This study aimed to develop a computer-aided diagnosis (CADx) system to establish the diagnosis of early-stage cancers using nonmagnified endoscopic white-light images alone. METHODS: From 5108 images, 1513 lesions (Tis, 1074; T1a, 145; T1b, 294) were collected from 1470 patients at 10 academic hospitals and assigned to training and testing datasets (3:1). The ResNet-50 network was used as the backbone to extract features from images. Oversampling and focal loss were used to compensate class imbalance of the invasive stage. Diagnostic performance was assessed using the testing dataset including 403 CRCs with 1392 images. Two experts and 2 trainees read the identical testing dataset. RESULTS: At a 90% cutoff for the per-lesion score, CADx showed the highest specificity of 94.4% (95% confidence interval [CI], 91.3-96.6), with 59.8% (95% CI, 48.3-70.4) sensitivity and 87.3% (95% CI, 83.7-90.4) accuracy. The area under the characteristic curve was 85.1% (95% CI, 79.9-90.4) for CADx, 88.2% (95% CI, 83.7-92.8) for expert 1, 85.9% (95% CI, 80.9-90.9) for expert 2, 77.0% (95% CI, 71.5-82.4) for trainee 1 (vs CADx; P = .0076), and 66.2% (95% CI, 60.6-71.9) for trainee 2 (P < .0001). The function was also confirmed on 9 short videos. CONCLUSIONS: A CADx system developed with endoscopic white-light images showed excellent per-lesion specificity and accuracy for T1b lesion diagnosis, equivalent to experts and superior to trainees. (Clinical trial registration number: UMIN000037053.).


Assuntos
Neoplasias Colorretais , Diagnóstico por Computador , Humanos , Neoplasias Colorretais/diagnóstico por imagem , Computadores , Endoscopia/métodos
7.
Digestion ; 103(2): 126-132, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34551417

RESUMO

BACKGROUND: Duodenal ulcers are classified into bulbar and post-bulbar ulcers. The aim of this study is to compare the long-term outcomes of patients with post-bulbar ulcer bleeding and those with bulbar ulcer bleeding. METHODS: A total of 272 patients with hemorrhagic duodenal ulcers requiring hospitalization were included. Their medical records were retrospectively reviewed. RESULTS: All patients were categorized as bulbar or post-bulbar bleeding ulcer groups. The post-bulbar ulcer group had more patients of advanced age, concurrent malignancy, diabetes mellitus, hypertension, cirrhosis, and chronic kidney disease undergoing hemodialysis. We performed long-term follow-up for an average of 2.6 years. The mortality rate during the follow-up period in the post-bulbar ulcer group was significantly higher than that in the bulbar ulcer group (p < 0.001). The PNED score was a better predictor of 30-day mortality compared to the complete Rockall score and the Glasgow-Blatchford Score. Predictors of mortality were evaluated using a Cox proportional hazards regression model. In multivariate analysis, post-bulbar ulcer, concurrent malignancy, cirrhosis, antiplatelet/anticoagulant use, and transfusion were significant predictors of mortality. CONCLUSIONS: Patients with post-bulbar ulcers have a poorer prognosis than those with bulbar ulcers. After the diagnosis of hemorrhagic post-bulbar duodenal ulcer, close follow-up is necessary.


Assuntos
Úlcera Duodenal , Infecções por Helicobacter , Helicobacter pylori , Úlcera Duodenal/complicações , Úlcera Duodenal/terapia , Duodeno , Humanos , Úlcera Péptica Hemorrágica/diagnóstico , Úlcera Péptica Hemorrágica/etiologia , Úlcera Péptica Hemorrágica/terapia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Úlcera/complicações , Úlcera/terapia
8.
Surg Endosc ; 36(11): 8316-8325, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35508665

RESUMO

BACKGROUND AND AIMS: Early gastric cancer (EGC) lesions are often subtle and endoscopically poorly visible. The aim of this study is to evaluate the additive effect of linked color imaging (LCI) next to white-light endoscopy (WLE) for identification of EGC, when assessed by expert and non-expert endoscopists. METHODS: Forty EGC cases were visualized in corresponding WLE and LCI images. Endoscopists evaluated the cases in 3 assessment phases: Phase 1: WLE images only; Phase 2: LCI images only; Phase 3: WLE and LCI images side-to-side. First, 3 expert endoscopists delineated all cases. A high level of agreement between the expert delineations corresponded with a high AND/OR ratio. Subsequently, 62 non-experts indicated their preferred biopsy location. Outcomes of the study are as follows: (1) difference in expert AND/OR ratio; (2) accuracy of biopsy placement by non-expert endoscopists; and (3) preference of imaging modality by non-expert endoscopists. RESULTS: Quantitative agreement between experts increased significantly when LCI was available (0.58 vs. 0.46, p = 0.007). This increase was more apparent for the more challenging cases (0.21 vs. 0.47, p < 0.001). Non-experts placed the biopsy mark more accurately with LCI (82.3% vs. 87.2%, p < 0.001). Again this increase was more profound for the more challenging cases (70.4% vs. 83.4%, p < 0.001). Non-experts indicated to prefer LCI over WLE. CONCLUSION: The addition of LCI next to WLE improves visualization of EGC. Experts reach higher consensus on discrimination between neoplasia and inflammation when using LCI. Non-experts improve their targeted biopsy placement with the use of LCI. LCI therefore appears to be a useful tool for identification of EGC.


Assuntos
Neoplasias Gástricas , Humanos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Aumento da Imagem/métodos , Detecção Precoce de Câncer/métodos , Imagem de Banda Estreita/métodos , Endoscopia
9.
Dig Endosc ; 34(5): 1012-1020, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34942042

RESUMO

OBJECTIVES: Early gastric cancers (EGCs) of the elevated type or with submucosal invasion are easily found by routine endoscopy. However, most early cancers are challenging to detect because of subtle morphological or color differences from surrounding atrophic mucosa and intestinal metaplasia. Linked color imaging (LCI) enhances mucosal color difference, making it easier to detect EGCs. The aim of this study is to clarify the advantages and possible disadvantages of LCI for screening for obscure EGC. METHODS: A total of 665 malignant gastric lesions resected using endoscopic submucosal dissection between January 2015 and April 2018 were retrospectively reviewed. Obviously detectable lesions were not included in the main analysis when determining the target lesion. White light imaging (WLI)/LCI images of 508 endoscopically obscure malignant lesions were included in the final analysis and evaluated by three non-expert and three expert endoscopists using visibility scores for detection and extent. RESULTS: The detection visibility scores using LCI were significantly higher than those using WLI regardless of lesion characteristics including location, size, histological type, depth of invasion, and Helicobacter pylori status. The detection score improved in 46.4% cases and deteriorated in 4.9% when the modality changed from WLI to LCI. A mixed-effects multivariate logistic regression analysis showed that use of LCI (odds ratio [OR] 2.57), elevated type (OR 1.92), invasion to submucosa (OR 2.18) were significantly associated with improved visibility of EGC. CONCLUSIONS: Linked color imaging significantly improves visibility of EGC regardless of differences in lesion morphology, histology, location, depth of invasion, and H. pylori status compared to conventional WLI.


Assuntos
Helicobacter pylori , Neoplasias Gástricas , Cor , Endoscopia Gastrointestinal , Humanos , Análise Multivariada , Estudos Retrospectivos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Neoplasias Gástricas/cirurgia
10.
Gastrointest Endosc ; 92(2): 368-379, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32119937

RESUMO

BACKGROUND AND AIMS: Colorectal endoscopic submucosal dissection (ESD) is recognized as a challenging procedure. Previously, we reported that a new ESD strategy using the pocket-creation method (PCM) is useful for colorectal ESD, but no prospective randomized study has evaluated the efficacy of the PCM. The aim of this study was to evaluate the efficacy and safety of PCM for colorectal ESD compared with the conventional method (CM). METHODS: This was a prospective randomized controlled trial at 3 institutions in Japan. Patients with superficial colorectal neoplastic lesions >20 mm predicted to be intramucosal were randomly assigned to undergo ESD using the PCM or CM. Primary outcome was the ESD completion rate defined as completion of colorectal ESD with an en bloc resection using the assigned ESD method without changing to other methods or assisted by other devices. RESULTS: We analyzed 59 patients with 59 colorectal tumors in the PCM group and 55 in the CM group. The ESD completion rate was significantly higher in the PCM group compared with the CM group (93% [55/59] vs 73% [40/55]; P  = .01). En bloc resection rates, R0 resection rates, procedure time, and dissection speed were not significantly different between the 2 groups. The incidence of adverse events was similar in the 2 groups. CONCLUSIONS: Use of the PCM allows the endoscopist to complete the procedure with the intended method more often than the CM with similar clinical outcomes. (Clinical trial registration number: UMIN 000024394.).


Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Neoplasias Colorretais/cirurgia , Humanos , Japão , Estudos Prospectivos , Resultado do Tratamento
11.
Gastrointest Endosc ; 89(5): 1045-1053, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30716306

RESUMO

BACKGROUND AND AIMS: Colonic endoscopic submucosal dissection (ESD) is more difficult than rectal ESD because of poor maneuverability of the endoscope due to physiologic flexion, peristalsis, and respiratory movements. The aim of this study was to assess the usefulness of the pocket-creation method (PCM) for colonic ESD compared with the conventional method (CM) regardless of lesion shape or location. METHODS: A total of 887 colorectal lesions were treated by ESD. Of 887 lesions, 271 rectal lesions, 72 lesions smaller than 20 mm in diameter, and 1 non-neoplastic lesion were excluded. This is a retrospective chart review of the remaining 543 colon lesions in 512 patients. We divided them into the PCM group (n = 280) and the CM group (n = 263). The primary outcome was the en bloc resection rate. Secondary outcomes were R0 resection (en bloc resection with negative margin), adverse events, dissection time (in minutes), and dissection speed (in mm2/min). RESULTS: The PCM group achieved a significantly higher en bloc resection rate (PCM, 100% [280/280], vs CM, 96% [253/263]; P < .001) and R0 resection rate (91% [255/280] vs 85% [224/263], respectively; P = .033) than the CM group. Dissection time was similar (69.5 ± 44.4 vs 78.7 ± 62.6 minutes, P = .676). Dissection speed was significantly faster with the PCM than with the CM (23.5 ± 11.6 vs 20.9 ± 13.6 mm2/min, P < .001). The incidence of adverse events was similar (perforation, 2% vs 4% [P = .152], and delayed bleeding, 2% vs 1% [P = .361]). CONCLUSIONS: Colonic ESD using the PCM significantly improves the rates of en bloc resection and R0 resection and facilitates rapid dissection.


Assuntos
Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa/métodos , Perfuração Intestinal/prevenção & controle , Duração da Cirurgia , Adulto , Idoso , Análise de Variância , Colonoscopia/métodos , Bases de Dados Factuais , Dissecação/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Estudos Retrospectivos , Medição de Risco , Resultado do Tratamento , Gravação em Vídeo
18.
Endosc Int Open ; 10(5): E644-E652, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35571481

RESUMO

Background and study aims Ultrathin endoscopy causes a minimal gag reflex and has minimal effects on cardiopulmonary function. Linked color imaging (LCI) is useful for detection of malignancies in the digestive tract. The aim of this study was to clarify whether LCI with ultrathin endoscopy facilitates detection of early gastric cancer (EGC) despite its lower resolution compared with high-resolution white light imaging (WLI) with standard endoscopy. Patients and methods This was a retrospective analysis with prospectively collected video, including consecutive 166 cases of EGC or gastric atrophy alone. Ninety seconds of screening video was collected using standard and ultrathin endoscopes with both WLI and LCI for each case. Three expert endoscopists assessed each video and the sensitivity of detecting EGC calculated. Color difference calculations were performed. Results Sensitivities using ultrathin WLI, ultrathin LCI, standard WLI, and standard LCI for the identification of cancer were 66.0 %, 80.3 %, 69.9 %, and 84.0 %, respectively. The color difference between malignant lesions and surrounding mucosa with ultrathin LCI and standard LCI were significantly higher than using ultrathin WLI or standard WLI, supported subjectively by the visibility score. Ultrathin LCI color difference and visibility score were significantly higher than standard WLI. Conclusions LCI with a low-resolution ultrathin endoscope is superior to WLI with a high-resolution standard endoscope for gastric cancer screening. This suggests that the high color contrast between EGC and the surrounding mucosa is more important than high-resolution images.

19.
Front Med (Lausanne) ; 9: 835013, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35514753

RESUMO

Background and Study Aims: The resection strategy for rectal neuroendocrine tumors (NET) < 10 mm is not uniform. We compared the utility of underwater endoscopic mucosal resection (UEMR) to endoscopic submucosal resection with a ligation device (ESMR-L) to resect rectal NETs. Patients and Methods: Patients with rectal NET < 10 mm treated with UEMR or ESMR-L were included. Their medical records were retrospectively reviewed. Results: Thirty-two patients were divided into a UEMR group (n = 7) and an ESMR-L group (n = 25). Histopathological diagnosis of NET by biopsy was known before resection in 43% (3/7) in the UEMR group and 68% (17/25) in the ESMR-L group, (p = 0.379). UEMR was performed on an outpatient basis for all patients, and 92% of ESMR-L (23/25) were performed as inpatient procedures (p < 0.001). The procedure time was significantly shorter in the UEMR group than in the ESMR-L group [median (IQR), min, 6 (5-8) vs. 12 (9-14), p = 0.002]. En bloc resection and R0 resection rates were 100% in both groups. Pathological evaluations were predominantly NET G1 in both groups (UEMR: 7/7, 100% and ESMR-L: 23/25, 92%). Two patients in the ESMR-L group developed delayed bleeding, controlled by endoscopic hemostasis. Device costs were significantly higher in the ESMR-L group than the UEMR group by approximately US$180 [median (IQR), $90.45 (83.64-108.41) vs. $274.73 (265.86-292.45), P < 0.001]. Conclusion: UEMR results in similar resection quality with shorter procedure time and lower costs compared to ESMR-L. We recommend UEMR for the resection of rectal NET < 10 mm.

20.
Endosc Int Open ; 10(12): E1577-E1582, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36531686

RESUMO

Background and study aims Underwater endoscopic mucosal resection (UEMR) does not always result in en bloc resection of large colorectal lesions. The aim of this study was to demonstrate the feasibility of en bloc resection with progressive polyp contraction with underwater endoscopic mucosal resection (PP-CUE) of large, superficial colorectal lesions. The advantage of PP-CUE is to enable resection of a superficial non-polypoid lesion that is larger than the snare diameter. Patients and methods Eleven consecutive lesions in ten patients who underwent UEMR with PP-CUE of large superficial colorectal lesions (20 mm or greater) were included. Results The median lesion diameter was 24 mm (interquartile range [IQR], 20-24 mm). All lesions were larger than the 15-mm rotatable snare that was used. Median procedure time and PP-CUE time were 11 minutes (IQR, 8.5-12.3) and 2.3 minutes (IQR, 1.9-3.4), respectively. Pathological diagnoses of resected specimens included six adenomas, three sessile serrated lesions, and two slightly invasive submucosal carcinomas. En bloc and R0 resection rates were both 91 % (10/11). No adverse events occurred. Conclusions PP-CUE is useful to resect superficial non-polypoid colorectal lesions 20 to 25 mm in diameter in an en bloc fashion.