Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(4)2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35214266

RESUMO

Various biosensors that are based on microfabrication technology have been developed as point-of-care testing devices for disease screening. The Fabry-Pérot interferometric (FPI) surface-stress sensor was developed to improve detection sensitivity by performing label-free biomarker detection as a nanomechanical deflection of a freestanding membrane to adsorb the molecules. However, chemically functionalizing the freestanding nanosheet with excellent stress sensitivity for selective molecular detection may cause the surface chemical reaction to deteriorate the nanosheet quality. In this study, we developed a minimally invasive chemical functionalization technique to create a biosolid interface on the freestanding nanosheet of a microelectromechanical system optical interferometric surface-stress immunosensor. For receptor immobilization, glutaraldehyde cross-linking on the surface of the amino-functionalized parylene membrane reduced the shape variation of the freestanding nanosheet to 1/5-1/10 of the previous study and achieved a yield of 95%. In addition, the FPI surface-stress sensor demonstrated molecular selectivity and concentration dependence for prostate-specific antigen with a dynamic range of concentrations from 100 ag/mL to 1 µg/mL. In addition, the minimum limit of detection of the proposed sensor was 2,000,000 times lower than that of the conventional nanomechanical cantilevers.


Assuntos
Técnicas Biossensoriais , Sistemas Microeletromecânicos , Neoplasias da Próstata , Biomarcadores , Técnicas Biossensoriais/métodos , Humanos , Imunoensaio/métodos , Masculino , Neoplasias da Próstata/diagnóstico
2.
Biosens Bioelectron ; 172: 112778, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33157412

RESUMO

We demonstrated an optical interferometer-based surface-stress immunosensor using freestanding polymethyl methacrylate (PMMA)/parylene-C nanosheet with high sensitivity for detection of biomolecules. PMMA/parylene-C nanosheets were transferred onto a silicon substrate with microcavities to fabricate freestanding submicron-thick membrane with a sealed cavity structure. The adhesive force between the transferred parylene-C and binder parylene-C layer was measured to be 1.06-2.4 N/10 mm by tape test. Evading Debye shielding, these nanomechanical sensors allow detection of the adsorption on the membrane surface through changes in surface stress transduced by the electric charge. We optimized the density of receptors and mode of immobilization for high sensitivity. To evaluate the selectivity of the sensor, membrane deflections induced by various proteins were measured and the spectral shifts showed high selectivity only for the target antigen. The minimum limit of detection (LOD) of the sensor for human serum albumin antigen was 0.1-1 fg/mL (1.5-15 aM), which was 20,000 times lower than that of the conventional micro-cantilever sensor.


Assuntos
Técnicas Biossensoriais , Sistemas Microeletromecânicos , Humanos , Imunoensaio , Polímeros , Polimetil Metacrilato , Xilenos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA