Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Rural Remote Health ; 19(3): 5255, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31476276

RESUMO

INTRODUCTION: This article describes the implementation of a novel technology tool to capture demographic distribution and clinical presentation of patients in rural vision centers using the eyeSmart electronic medical record (EMR) app in a three-tier eyecare network in India. METHODS: A two-year retrospective review of all patients who presented to the rural vision centers of LV Prasad Eye Institute (LVPEI) eyecare network was performed from September 2016 to August 2018 using an in-house developed eyeSmart EMR app. RESULTS: A total of 501 771 patients were captured on the eyeSmart EMR app across the LVPEI network. The ratio of males (n=273 985, 54.60%) and females (n=227 786, 45.40%) presenting to the rural vision centers was 1.2:1. The most prevalent ocular disorder was refractive errors (n=273 720, 44.32%). CONCLUSIONS: This study details the demographic distribution and prevalence of ocular disorders in a large cohort of Indian patients and demonstrates the potential for real-time analytics through the use of EMR systems. This provides rigorous evidence for the community and eyecare providers that the use of a web application/tablet app (eyeSmart) aids in providing better eyecare services in rural areas. It helps in creating government policies and improves the treatment strategies for various preventable ocular disorders in India.


Assuntos
Registros Eletrônicos de Saúde/estatística & dados numéricos , Erros de Refração/epidemiologia , Serviços de Saúde Rural/organização & administração , População Rural/estatística & dados numéricos , Adulto , Feminino , Humanos , Índia/epidemiologia , Masculino , Erros de Refração/terapia , Acuidade Visual
2.
Optom Vis Sci ; 92(2): e42-5, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25479452

RESUMO

PURPOSE: To report the use of femtosecond laser platform to remove a glass foreign body (FB) and remove scar by performing sutureless lamellar keratoplasty. CASE REPORT: A 34-year-old man presented with a posttraumatic anterior stromal scar and retained corneal glass FB after injury to his left eye, sustained in a prior vehicular accident. Right eye examination was essentially normal. Best-corrected visual acuity of the left eye was 20/320. He underwent femtosecond laser-assisted sutureless anterior lamellar keratoplasty using the 500-kHz femtosecond laser machine. The host bed and donor lenticule diameters were 7.9 and 7.8 mm and the thickness of the lenticule was 125 and 150 µm, respectively. The recipient lenticule was obtained by placing the lamellar incision that encompassed the FB. When the recipient lenticule was lifted, partially embedded FB present in the stroma was removed after dislodging it with a 26-gauge needle. The femtosecond-dissected donor button was placed onto the stromal bed with a snug fit. No sutures were taken. Postoperatively, best-corrected visual acuity improved to 20/50 at 1 month and 20/30 at 7 months of follow-up. CONCLUSIONS: Femtosecond laser-assisted sutureless anterior lamellar keratoplasty is a promising modality for lamellar keratoplasty, and as the depth of the incision can be obtained with precision, impacted stromal FBs can be removed in a single procedure along with scars.


Assuntos
Substância Própria/lesões , Transplante de Córnea/métodos , Corpos Estranhos no Olho/cirurgia , Ferimentos Oculares Penetrantes/cirurgia , Vidro , Lasers de Excimer/uso terapêutico , Acidentes de Trânsito , Adulto , Cicatriz/cirurgia , Paquimetria Corneana , Substância Própria/patologia , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/fisiopatologia , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/fisiopatologia , Humanos , Masculino , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
3.
Optom Vis Sci ; 91(7): 752-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24901484

RESUMO

PURPOSE: To measure the accommodative response in unsighted or profoundly vision impaired (PVI) eyes when accommodation is elicited in the fellow, sighted eye. METHODS: Eighty-eight unilaterally PVI subjects (UPS) and 97 bilaterally sighted subjects (BSS) (10 to 45 years) were enrolled. Subjects had clear ocular media for auto-refraction and could steadily fixate targets with the sighted eye. For BSS, a long-pass filter was placed in front of one eye to simulate unilateral blindness. Both eyes were measured with a Shin-Nippon auto-refractor while fixating a 4/40 letter at 4 m and then an N8 letter at 40 cm and at 33 cm. Accommodation was calculated as the difference between distance and near refraction. RESULTS: Only subjects with repeatable alignment between measurements were included in the analyses (64 UPS, 95 BSS). Results were analyzed using t test and a generalized linear mixed model including age, sightedness, distance spherical equivalent, and accommodation as factors. The t test found no significant difference between eyes for UPS (p = 0.981 at 40 cm and p = 0.663 at 33 cm). For BSS, the sighting eye produced statistically significant but only slightly greater amounts of accommodation than the filtered eye (0.098 diopters [D], p = 0.002 at 40 cm and 0.189 D, p < 0.001 at 33 cm). The generalized linear mixed model found no difference between BSS and UPS in terms of difference in accommodation between eyes (p = 0.128 at 40 cm and p = 0.157 at 33 cm). CONCLUSIONS: The PVI eyes of unilaterally PVI individuals display similar accommodative response to their fellow, sighted eyes when accommodation is elicited by near target of up to 3 D to the fellow eye. However, the difference in accommodative response between PVI and fellow, sighted eye is related to the amount of accommodation elicited.


Assuntos
Acomodação Ocular/fisiologia , Refração Ocular/fisiologia , Transtornos da Visão/fisiopatologia , Pessoas com Deficiência Visual , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Testes Visuais , Visão Ocular , Adulto Jovem
4.
Cont Lens Anterior Eye ; 47(3): 102164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38594154

RESUMO

PURPOSE: To determine the changes in keratometry measurements and refraction in patients having the thermo-mechanical periorbital skin treatment, Tixel®, to treat dry eye disease (DED). METHODS: A multi-centre, prospective, non-masked study was conducted. DED patients were recruited in 3 international centres and were evaluated in 5 visits separated by an interval of 2 weeks except for the last visit which took place after 18 weeks from visit 1. The same clinical examination was performed at all visits: OSDI questionnaire, tear stability, keratometry, best corrected visual acuity and refraction. Tixel® treatment was applied at the first 3 visits. RESULTS: 89 participants (24 males/65 females; mean age: 55.0 ± 14.2 years) were included: 20 presented moderate DED symptoms and 69 severe DED symptoms. Significant differences were found for the spherocylindrical refraction (vector analysis) between visit 1 and visits 2 and 3. Following cumulative analysis, 11.86 % and 16.94 % of participants had more than 0.5 dioptre (D) change in mean keratometry and keratometric astigmatism, respectively, at 3 months post-treatment. A total of 5.40 % had a sphere and cylinder change greater than 0.50D and 16.21 % had the axis changed more than 10 degrees (vector analysis). These changes were particularly significant in patients with severe DED symptoms. CONCLUSIONS: Keratometry readings and refraction can change following thermo-mechanical skin treatment for DED, especially in those patients with severe DED symptoms. This should be considered as potential errors in intraocular lens calculations may be induced.


Assuntos
Extração de Catarata , Síndromes do Olho Seco , Refração Ocular , Acuidade Visual , Humanos , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/terapia , Síndromes do Olho Seco/diagnóstico , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Adulto , Córnea/fisiopatologia
5.
Int Ophthalmol ; 33(2): 117-23, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23053772

RESUMO

The purpose of the present study was to analyze the microbiological profile of cases of keratitis following trauma with vegetative matter in a tertiary care center. A retrospective review of the medical records of 49 patients with keratitis following vegetative matter injury over a 3-month period was performed. All patients underwent corneal scraping for smears and inoculation onto various culture media. The microbiological profile was based on the smear and culture reports. For patients who were culture-negative, outcome after standard empirical antibacterial therapy as per hospital protocol was analyzed. Thirteen patients with corneal ulcers had fungal etiology, eight had bacterial etiology, and two had protozoal etiology, while 13 patients were polymicrobial and 13 were culture-negative. Polymicrobial infections were mainly bacterial (eight cases), and the remaining five cases had coexistent fungal and bacterial etiology. The treatment was directed to the specific organism and patients improved with medical or surgical therapy. Only a third of culture-negative cases showed fungal etiology on biopsy or histopathology after keratoplasty while a third showed improvement with therapy. Corneal infections following vegetative matter trauma show a varied etiological profile; however, bacterial and polymicrobial infections are more prevalent. Empirical anti-fungal therapy, as commonly practiced, must be avoided in cases with vegetative matter injury.


Assuntos
Úlcera da Córnea/microbiologia , Infecções Oculares Bacterianas/microbiologia , Infecções Oculares Fúngicas/microbiologia , Traumatismos Oculares/microbiologia , Ceratite/microbiologia , Acanthamoeba , Adulto , Amebíase/tratamento farmacológico , Amebíase/epidemiologia , Amicacina/uso terapêutico , Antibacterianos/uso terapêutico , Biguanidas/uso terapêutico , Úlcera da Córnea/tratamento farmacológico , Úlcera da Córnea/epidemiologia , Desinfetantes/uso terapêutico , Infecções Oculares Bacterianas/tratamento farmacológico , Infecções Oculares Bacterianas/epidemiologia , Infecções Oculares Fúngicas/tratamento farmacológico , Infecções Oculares Fúngicas/epidemiologia , Traumatismos Oculares/epidemiologia , Feminino , Humanos , Ceratite/tratamento farmacológico , Ceratite/epidemiologia , Masculino , Plantas , Prevalência , Estudos Retrospectivos , Fatores de Risco
6.
Int Ophthalmol ; 32(3): 269-71, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22456795

RESUMO

The objective of this case report is to report two cases of fish-hook injury to the eye and ocular adnexa with review of literature. Both patients with fish-hook injuries were professional fishermen. The first subject was hit in his right eye by a hook which became embedded in the right cornea. He cut off the line but made no attempt to remove the hook and presented to the emergency department with the hook hanging from his right eye. Under general anaesthesia, the hook was rotated out without causing any further damage to the cornea and intraocular structures. The second subject was reeling the hook back to shore when it hit him in the face and embedded itself in the upper eyelid. He was immediately taken to the emergency department and after careful examination the eye was found to be unharmed and the hook was removed through a small incision under local anaesthesia. Fish-hook injuries, though rare, can result in visual morbidity. The hook should be removed under careful examination using the correct technique. The shaft of the hook should be left long and no attempt should be made by the subject or any non-trained person to remove it as doing so can result in further damage.


Assuntos
Lesões da Córnea , Corpos Estranhos no Olho/etiologia , Ferimentos Oculares Penetrantes/etiologia , Pálpebras/lesões , Pesqueiros/instrumentação , Traumatismos Ocupacionais/etiologia , Adulto , Corpos Estranhos no Olho/patologia , Corpos Estranhos no Olho/cirurgia , Ferimentos Oculares Penetrantes/patologia , Ferimentos Oculares Penetrantes/cirurgia , Humanos , Masculino , Traumatismos Ocupacionais/patologia , Traumatismos Ocupacionais/cirurgia , Procedimentos Cirúrgicos Oftalmológicos
7.
Int Ophthalmol ; 31(3): 219-22, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21424885

RESUMO

Indications for the Boston keratoprosthesis differ throughout the world depending on the prevailing regional causes of end-stage corneal disease. We report the short term anatomical and functional outcomes of the Boston type 1 keratoprosthesis for severe bilaterally blinding vernal keratoconjunctivitis and Mooren's ulcer. A retrospective chart review was conducted of 2 patients who underwent several unsuccessful ocular surface reconstruction procedures before Boston type 1 keratoprosthesis implantation. The anatomical and visual outcomes of the Boston type 1 keratoprosthesis at 1 year of follow-up were assessed clinically and by anterior segment optical coherence tomography imaging. The keratoprosthesis was retained in both the eyes at 1 year postoperatively with a best-corrected visual acuity of 20/30 in both patients. To our knowledge this is the first report of successful Boston keratoprosthesis implantation for these two unusual indications.


Assuntos
Segmento Anterior do Olho/patologia , Cegueira/etiologia , Conjuntivite Alérgica/cirurgia , Úlcera da Córnea/cirurgia , Próteses e Implantes , Cegueira/cirurgia , Criança , Conjuntivite Alérgica/complicações , Conjuntivite Alérgica/diagnóstico , Úlcera da Córnea/complicações , Úlcera da Córnea/diagnóstico , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Tomografia de Coerência Óptica , Acuidade Visual
8.
Rom J Ophthalmol ; 64(2): 158-167, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32685782

RESUMO

Introduction: Collagen cross-linking is a well-established modality that could stop the keratoconus from progressing. Off late, newer protocols have been suggested for progressive keratoconus, which include the use of hypoosmolar riboflavin for thinner corneas and the use of accelerated CXL protocol to reduce the effective treatment time. Objective: To assess the safety and efficacy of different protocols of conventional CXL, hypoosmolar CXL and accelerated CXL in patients with keratoconus. Materials & methods: It was a prospective, interventional study with minimum of 12 months follow-up. Patients were divided into 3 groups; conventional CXL, CXL using hypotonic riboflavin and accelerated CXL group. Primary outcome measures - For efficacy, Sim Kmax and Sim Kmin (Progression (Kmax > +1 D), stabilization (Kmax +1 D to -1 D) and regression (Kmax > -1 D). For safety - endothelial count evaluation (decrease >10% amounted to compromise the safety of the procedure). Secondary outcome measures - BCVA and adverse events. Results: 32 eyes underwent isotonic CXL treatment. Pre-treatment and post-treatment BCVA were 0.16 +/- 0.15 and 0.10 +/- 0.11 log MAR; specular counts 2782.81 +/- 307.25 (cells/ mm2) and 2708.5 +/- 263.27 (cells/ mm2) (p=0.05); KMax values 55.31 +/- 4.12 D and 53.9 +/- 3.77 D (p=0.0001). 16 eyes underwent hypotonic CXL treatment. Pre-treatment and post-treatment BCVA were 0.15 +/- 0.13 log MAR and 0.14 +/- 0.14; specular count 2701.19 +/- 243.25 (cells/ mm2) and 2713.5 +/- 369 (cells/ mm2) (p= 1) and KMax values 54.74 +/- 7.44 D and 52.74 +/- 6.76 D (p = 0.002). 15 eyes underwent accelerated CXL treatment. Pre-treatment and post-treatment BCVA were 0.16 +/- 0.15 and 0.10 +/- 0.12 log MAR; specular counts 2967.53 +/- 356.48 and 2893.07 +/- 336.55 (cells/ mm2) (p = 0.78) and KMax values 55.19 +/- 5.46 D and 54.24 +/- 5.33 D (p = 0.337). Conclusion: All three protocols appeared safe and efficacious as therapeutic regimen for progressive keratoconus.


Assuntos
Colágeno/uso terapêutico , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Refração Ocular/fisiologia , Acuidade Visual , Adolescente , Criança , Topografia da Córnea/métodos , Feminino , Seguimentos , Humanos , Ceratocone/diagnóstico , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Riboflavina/uso terapêutico , Resultado do Tratamento
9.
Indian J Ophthalmol ; 68(12): 3077-3081, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33245060

RESUMO

We report a case series of patients who developed post-laser-assisted in situ keratomileusis (LASIK) ectasia or had a progression of keractesia during pregnancy. We reviewed the medical records of 12 patients (20 eyes) who had reported deterioration of vision during their pregnancy and were diagnosed with keractesia. All 12 patients had experienced symptoms of deterioration of vision between 2 months to 1 year of onset of their pregnancies. A total of 17 eyes of 10 patients had developed post-refractive surgery keractesia. Sixteen of these had undergone LASIK and one had undergone femtosecond lenticule extraction (FLEX). Three eyes of two patients had an exacerbation of keratoconus during pregnancy while one patient had associated hypothyroidism. The results indicate that the hormonal changes that take place in pregnant women can affect the biomechanical stability of the cornea and may trigger the onset of keractesia.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Córnea/cirurgia , Topografia da Córnea , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Lasers de Excimer , Miopia/diagnóstico , Miopia/cirurgia , Gravidez , Acuidade Visual
10.
Cont Lens Anterior Eye ; 43(3): 256-260, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31813766

RESUMO

PURPOSE: To report the role of Bulls eye drop applicator device in self-instillation of eye drops and in prevention of wastage of medicine. METHODS: A small pocket sized device "Bulls eye drop applicator" was developed, which is a simple, handy, mirror-based attachment which can be attached to any eye drop bottle to help in accurate self-instillation of the drops in the eye. The prototype of this device was tried in ten volunteer subjects (Group 1) and 15 patients (Group 2); they were asked to use lubricating eye drops (5 ml bottle) in one eye without the device (N) and in the other eye with the device (M). The numbers of attempts for the application of eye drops were noted and the residual eye drops in the returned bottles were measured for quantitative assessment. RESULTS: Ten volunteers and 11/15 patients completed the study. At the completion of the study, there were a total of 232 applications of eye drops in the Group 1 N (without device) and 1 M (with device). To achieve these 232 applications, there were 330 attempts without the device and 266 attempts of instillation were needed with the device (P < 0.0001). In Group 2, there were a total of 544 applications of eye drops; to achieve this, there were 879 attempts in Group 2 N and 685 attempts of instillation in Group 2 M (p < 0.0001). The cumulative quantity of residual drops in the returned bottles collected from Group 2 N was 5.1 ml and it was 19.7 ml in Group 2 M (p = 0.001). CONCLUSIONS: The number of attempts of instillation reduced significantly with the use of the eye drop applicator device. The use of eye drops applicator device reduced the wastage of drops from 42.2% to 14.6% in Group 1 N Vs Group 1 M and saving of about 35.7 % in Group 2 M compared to Group 2 N.


Assuntos
Anti-Hipertensivos/administração & dosagem , Glaucoma/tratamento farmacológico , Acuidade Visual , Administração Tópica , Desenho de Equipamento , Feminino , Humanos , Lubrificantes Oftálmicos/farmacologia , Masculino , Soluções Oftálmicas/farmacologia
11.
Int J Telemed Appl ; 2019: 5683085, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31057606

RESUMO

PURPOSE: This study describes the development of an attachment for a smart tablet to stream live video information of an eye examination through the slit lamp. METHODS: A tablet attachment was developed that enables the live streaming of video from the slit lamp from the rural vision centers of the LVPEI network. A video streaming solution like Skype Lite was used to transmit the same. The eyeSmart app was utilized for the documentation of the clinical information of the patients. RESULTS: A tablet attachment of eyeSmart Cyclops was developed and piloted in 3 vision centers of the LVPEI network. CONCLUSION: The use of real-time video transmission illustrates a novel teleophthalmology solution in low resource settings to screen rural populations. The ability to transmit live video enables gathering more information than static images.

12.
Oman J Ophthalmol ; 12(3): 177-180, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31902993

RESUMO

BACKGROUND: Contact lenses (CLs) remain the mainstay in improving vision in patients having keratoconus. With corneal collagen cross-linking (CXL) performed worldwide, whether the same CLs can be used or needs replacement needed to be assessed and considered. AIMS: The aim of this study was to evaluate the changes in CL fitting following CXL. SETTINGS AND DESIGN: This is a retrospective study conducted at a tertiary center. SUBJECTS AND METHODS: We analyzed the medical records of patients who underwent CXL and used CL. Data collected included demographics, pre- and post-CXL refraction, corneal topography, anterior-segment examination, and CL [rigid gas permeable(RGP)] fitting details and duration between CXL and RGP fitting. STATISTICAL ANALYSIS: Descriptive analysis and paired t-test were used to compare the pre- and post-CXL data on refraction, visual acuity, and CL parameters. The statistical significance was kept at P < 0.05. RESULTS: Thirty-four eyes (keratoconus = 32, pellucid marginal degeneration = 1, and post-LASIK ectasia = 1) of 27 patients who used CL before and after undergoing CXL were analyzed. Mean duration between CXL and RGP lens use was 2.53 months. Mean sphere and cylinder post-CXL was -4.11 ± 4.32 D and -3.54 ± 2.51 D, respectively. A mean change of 0.75 ± 3.72 D sphere and 0.71 ± 3.39 D cylinder was noted post-CXL. The post-CXL best spectacle-corrected visual acuity (CVA) was 0.52 ± 0.36 and with RGP lens it was 0.09 ± 0.18. There was no significant difference in pre- and post-CXL RGP lens CVA (0.07 ± 0.09 and 0.09 ± 0.18, respectively; P = 0.556). Pre-CXL, 3-point-touch fitting was in 24 eyes (70.59%) and central fluorescein pooling was in 10 eyes (29.41%). Post-CXL, 30 eyes (88.24%) had 3-point-touch and central fluorescein pooling was found in four eyes (11.76%). One patient had CL intolerance after CXL. Of the 32 keratoconus eyes, 62.5% (n = 20 eyes) were prescribed new lenses; 37.5% (n = 12 eyes) continued using own lenses. CONCLUSIONS: There was no significant difference in refraction, topography indices, and RGP lens parameters pre- and post-CXL. However, changes in RGP lens fitting characteristics suggest a possible change in shape or apex location of the cornea after CXL. RGP lenses remain the best option to improve visual acuity after CXL in corneal ectasia.

13.
Oman J Ophthalmol ; 12(3): 203-205, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31903000

RESUMO

We hereby report a case of infectious keratitis after laser in situ keratomileusis (LASIK) caused by Micrococcus luteus, a commensal, managed successfully in a nonimmunocompromised individual. A 25-year-old healthy male underwent uneventful bilateral simultaneous LASIK for myopia using disposable blades. Postoperatively, topical antibiotic and steroids were advised; he discontinued antibiotic on his own after using for a day. On the 5th postoperative day, he had pain, redness, decreased vision, and white spot in the left eye (LE) for 1-day duration. Uncorrected visual acuity (UCVA) of LE reduced to 20/80 from postoperative 20/20. Slit-lamp biomicroscopy revealed tiny infiltrate in the interface with reticular haze in the flap and stroma. Gram-positive cocci in pairs and tetrads were found on corneal smears that were collected after lifting the flap from infiltrate, stromal bed, and undersurface of the flap. M. luteus was isolated on culture. The infiltrate resolved with scarring with intensive topical antibiotics. UCVA was 20/25. To the best of our knowledge, this is a first case report of post-LASIK infectious keratitis caused by M. luteus.

14.
Int J Telemed Appl ; 2019: 8107064, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31929788

RESUMO

PURPOSE: The study aims to describe a novel method of utilization of the eyeSmart EMR (electronic medical record) app. It describes the demographic distribution, clinical presentation, query requested by the vision technician, and management advised to the patients by using "eyeSmart EMR" app from the vision centers located across a three-tier eye care network in India. METHODS: This is a retrospective review of all patients who required a tele-ophthalmology consultation from January 2017 to August 2018. The demographic, clinical details, and the impact of teleophthalmology using eyeSmart app, in the vision centers of a three-tier eye care network, was analyzed in detail. RESULTS: A total of 15,001 tele-ophthalmology consults were included which is from January 2017 to August 2018. The mean age was 38 ± 19 years and male to female ratio was 1 : 2. Video calls were performed for 6191 (41.27%) consults and the impact was measured. Additional clinical information was received in 65.61% consults through video call. Medical management was advised in 47.07% of patients and 30.30% were referred to higher centers for medical intervention and 0.59% were referred for surgical intervention, 16.23% were prescribed glasses. No intervention required for 0.69% of cases. Hence nil intervention was advised. CONCLUSION: The combination of using tablet and video calls with the help of eyeSmart EMR app is a novel method in teleophthalmology. It helps in connecting the patients at rural areas and the ophthalmologists in higher centers. The use of technology plays a vital role in the appropriate medical management of the patient.

15.
Indian J Ophthalmol ; 55(1): 21-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17189882

RESUMO

PURPOSE: To examine the hypothesis that initial smear examination results have a significant bearing on the management and outcome of suspected microbial keratitis. MATERIALS AND METHODS: One hundred and seventy consecutive patients with suspected microbial keratitis were included in a prospective nonrandomized comparative study and their detailed clinical and microbiological data (smears and cultures of corneal scrapings) were captured on a predesigned corneal ulcer database. Patients were divided into two groups: Group 1 included 68 patients with corneal scrapings negative in smears while Group 2 included 102 patients with corneal scrapings positive in smears. The two groups were compared for their clinico-microbiological profile, management and clinical outcome. The outcome was noted at three months. Fisher's exact test was applied for statistical analysis. RESULTS: Cultures were sterile in 57.3% of patients in Group 1 compared to 17.6% in Group 2. Scrapings that grew S. pneumoniae, gram-negative organisms, fungi and Acanthamoeba were more often positive in smears (18.6%, 11.8%, 19.6% and 2.9% respectively). While data on duration of prior treatment was not available, prior medication made no significant difference to smear results. More (79.3%) patients of Group 1 had small infiltrate size ( CONCLUSIONS: Initial smear examination helps in instituting specific therapy thereby improving the outcome in cases of microbial keratitis. Positive smears indicate greater severity of disease and prior medication may not be a significant cause of smear negativity.


Assuntos
Infecções Bacterianas/diagnóstico , Infecções Bacterianas/tratamento farmacológico , Ceratite/microbiologia , Micoses/diagnóstico , Micoses/tratamento farmacológico , Ceratite por Acanthamoeba/diagnóstico , Antibacterianos/uso terapêutico , Antifúngicos/uso terapêutico , Córnea/microbiologia , Córnea/parasitologia , Humanos , Ceratite/parasitologia , Técnicas Microbiológicas , Estudos Prospectivos
18.
Cornea ; 36(3): 300-303, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27811566

RESUMO

PURPOSE: To report the clinical and visual outcome of sutureless femtosecond laser-assisted anterior lamellar keratoplasty (FALK) for recurrent granular corneal dystrophy (GCD) in patients who had previously undergone penetrating keratoplasty and phototherapeutic keratectomy (PTK) performed for recurrent dystrophy in the grafted eyes. METHODS: Four eyes of 4 patients who underwent FALK for recurrence of GCD in previously grafted eyes and underwent PTK performed for initial recurrence in the grafts were included. Patients who had undergone FALK for other indications were excluded. The patients were evaluated for preoperative and postoperative best-corrected visual acuities (BCVA), and intraoperative and postoperative complications. Visual outcomes and complications, if any, were noted. RESULTS: FALK was uneventful in all 4 eyes. At last follow-up, BCVA improved by >2 lines in all eyes. Myopic shift in the refractive error was noted in 2 eyes. None of the eyes had any intraoperative or postoperative complications. One case had dissection margins cross the graft-host junction; however, no dehiscence occurred in this case. The grafts were clear at the last follow-up examinations. CONCLUSIONS: FALK is a safe and effective technique for the management of recurrence of GCD in post-penetrating keratoplasty and post-PTK eyes. BCVA improved by >2 lines after the FALK procedure. None of the patients in this series had any intraoperative or postoperative complications, which was indicative of the safety of the procedure.


Assuntos
Distrofias Hereditárias da Córnea/cirurgia , Cirurgia da Córnea a Laser/métodos , Transplante de Córnea/métodos , Ceratectomia Fotorrefrativa/efeitos adversos , Adulto , Idoso , Distrofias Hereditárias da Córnea/etiologia , Distrofias Hereditárias da Córnea/fisiopatologia , Feminino , Humanos , Complicações Intraoperatórias , Masculino , Complicações Pós-Operatórias , Recidiva , Doadores de Tecidos , Transplantados , Acuidade Visual/fisiologia
19.
Cornea ; 36(10): 1267-1269, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28749897

RESUMO

PURPOSE: To report the rare coexistence of keratoconus and Stevens-Johnson syndrome (SJS) managed with scleral contact lenses (ScCLs). METHODS: This is a retrospective case series. Five patients (9 eyes) who had coexisting SJS and corneal ectasia were identified from the database during the 2-year period. Diagnosis of SJS was based on a positive history of drug reactions, signs of ocular surface disease, and the presence of keratinization of lid margins. Keratoconus was diagnosed by slit-lamp biomicroscopy. RESULTS: Five eyes of 3 patients had coexisting SJS and keratoconus and were dispensed with ScCLs (PROSE, prosthetic replacement of the ocular surface ecosystem; Boston Foundation for Sight, Needham Heights, MA). All these patients had photophobia. Visual acuity improved in all these patients with ScCL wear. Two patients (4 eyes) were excluded from this study because they had SJS with generalized corneal thinning from limbus to limbus, corneal opacification, and pannus. One patient developed deep vessels in the cornea on prolonged ScCL wear. Reduction in the ScCL wear schedule and change of material with a higher Dk resulted in regression of vascularization. Case 3 developed conjunctival congestion and was uncomfortable wearing ScCLs, although visual acuity was 20/40. He discontinued using ScCL wear. CONCLUSIONS: Keratoconus, a noninflammatory condition of the cornea coexisted with inflammatory SJS. Managing such patients with ScCLs may improve vision and comfort.


Assuntos
Lentes de Contato , Ceratocone/terapia , Esclera , Síndrome de Stevens-Johnson/terapia , Adolescente , Adulto , Humanos , Ceratocone/epidemiologia , Masculino , Ajuste de Prótese , Estudos Retrospectivos , Síndrome de Stevens-Johnson/epidemiologia , Acuidade Visual/fisiologia
20.
Indian J Ophthalmol ; 64(2): 140-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27050350

RESUMO

PURPOSE: The purpose is to assess the clinical and visual outcome after phototherapeutic keratectomy (PTK) procedure in eyes with prior penetrating keratoplasty (PKP) for granular corneal dystrophy (GCD) and the time of performance of repeat PTK for recurrence. METHODS: PTK was performed for visually significant recurrence: A reduction in best-corrected visual acuity (BCVA) by >2 lines over BCVA before recurrence was considered as visually significant recurrence. Three eyes had amniotic membrane patch performed with PTK. The main outcome measures were a recurrence of GCD, clinical course, and visual outcome. Intervals between repeat PTK procedures were noted. RESULTS: Six patients (n = 10 eyes; males: 4, mean age 39 ± 13.97 years) underwent PTK. The mean pachymetry before first PTK was 527.1 ± 34 microns. The mean duration between PKP and first PTK was 85.1 months (range: 37-108 months). Two and three PTK procedures were done for seven and five eyes, respectively. Mean duration between first and second and second and third PTK was 62.12 ± 34.41 and 42.8 ± 13.54 months respectively. The average cut depth was 43.66 ± 19.57, 75 ± 43.30 and 39 ± 19.79 microns after the first, second and third PTK procedures, respectively. All eyes had a corneal haze. Pre first PTK mean BCVA was 20/200 and improved significantly after the first two PTK procedures to 20/40 and after the third PTK procedure to 20/32 (P < 0.001). Five eyes had hyperopia. One acute graft rejection was managed successfully at 5 months with medical therapy. CONCLUSION: Multiple PTK procedures can be performed safely with improved visual acuity in grafts without compromising graft survival.


Assuntos
Distrofias Hereditárias da Córnea/cirurgia , Ceratoplastia Penetrante , Lasers de Excimer/uso terapêutico , Ceratectomia Fotorrefrativa/métodos , Adulto , Distrofias Hereditárias da Córnea/diagnóstico , Distrofias Hereditárias da Córnea/fisiopatologia , Topografia da Córnea , Feminino , Seguimentos , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Tonometria Ocular , Acuidade Visual/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA