Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Singapore Med J ; 61(3): 137-141, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32488274

RESUMO

INTRODUCTION: This study aimed to investigate the causes, clinical management and outcomes of clinically significant pericardial effusions, and evaluate the practice of pericardiocentesis within an academic medical centre in Singapore, a multiethnic country in Southeast Asia. METHODS: Consecutive patients undergoing pericardiocentesis at a single Asian academic medical centre were identified. Patient demographics, echocardiographic findings, investigations, pericardiocentesis procedural details and clinical progress were tracked using a comprehensive electronic medical records system. RESULTS: Of 149 patients who underwent pericardiocentesis, malignancy (46.3%) was the most common cause of pericardial effusions, followed by iatrogenic postsurgical complications (17.4%). 77.3% of effusions were large and 69.8% demonstrated tamponade physiology. Pericardiocentesis guided by echocardiography and fluoroscopy was successful in 99.3% of patients and had a complication rate of 2.0%. Likelihood of effusion recurrence and survival to discharge was determined by the aetiology of the pericardial effusion. 24.6% of malignant effusions recurred, and the survival rate 12 months after drainage of a malignant pericardial effusion was 45.0%. Short-term mortality was highest among patients presenting with tamponade due to acute aortic syndromes and those with myocardial rupture due to ischaemic heart disease. CONCLUSION: Cancer and iatrogenic complications were the most common causes of pericardial effusion in this large cohort of Singapore patients. Pericardiocentesis has a high success rate and relatively low complication rate. Prognosis and clinical course after pericardiocentesis are determined by the underlying cause of the pericardial effusion.


Assuntos
Derrame Pericárdico/etiologia , Derrame Pericárdico/cirurgia , Pericardiocentese/métodos , Centros Médicos Acadêmicos , Adulto , Idoso , Povo Asiático , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Singapura/epidemiologia , Resultado do Tratamento
2.
Singapore Med J ; 60(11): 560-564, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31781776

RESUMO

Ebstein's anomaly is a congenital malformation characterised by tricuspid valve pathology with right heart enlargement. Cases of Ebstein's anomaly can vary widely in severity, anatomy and presentation. In this article, we presented three cases of Ebstein's anomaly and discussed the presentation as well as electrocardiographic (ECG) changes. Patients may first present to their primary care physicians with cardiac symptoms such as reduced effort tolerance together with an abnormal ECG. ECG changes suggestive of right heart enlargement are important in the initial consideration and eventual formal diagnosis of the condition.


Assuntos
Anomalia de Ebstein/diagnóstico por imagem , Eletrocardiografia , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico por imagem , Feminino , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Radiografia Torácica , Valva Tricúspide/diagnóstico por imagem
3.
Singapore Med J ; 60(5): 260-264, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30488081

RESUMO

Right ventricle to pulmonary artery (RV-PA) conduits have been used for the surgical repair of congenital heart defects. These conduits frequently become stenosed or develop insufficiency with time, necessitating reoperations. Percutanous pulmonary valve implantation (PPVI) can delay the need for repeated surgeries in patients with congenital heart defects and degenerated RV-PA conduits. We presented our first experience with PPVI and described in detail the procedural methods and the considerations that are needed for this intervention to be successful. Immediate and short-term clinical outcomes of our patients were reported. Good haemodynamic results were obtained, both angiographically and on echocardiography. PPVI provides an excellent alternative to repeat open-heart surgery for patients with congenital heart defects and degenerated RV-PA conduits. This represents a paradigm shift in the management of congenital heart disease, which is traditionally managed by open-heart surgery.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adulto , Cateterismo Cardíaco/instrumentação , Veia Femoral , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Desenho de Prótese , Singapura , Adulto Jovem
4.
Med Eng Phys ; 50: 1-11, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29102273

RESUMO

There has not been much progress in the development of transcatheter tricuspid valves to treat tricuspid regurgitation because of the difficulty in anchoring a stented valve onto the complex tricuspid annulus. Hence, the concept of heterotopic implantation of the transcatheter tricuspid valve onto the cavo-atrial junction was proposed. However, to date there has been no detailed in vitro investigation of the hemodynamic performance of this new device. The study utilises both 2-D and 3-D particle image velocimetry (PIV) to interrogate the flow patterns in the vicinity of the extra-cardiac tricuspid valves in an in vitro physiological flow loop, specifically at four measurement locations in the cavo-atrial anatomy. Comparison of the 2-D and 3-D PIV results revealed that accuracy of 2-D PIV would be acceptable at time point and at measurement locations where the velocity was mostly planar with minimal or low out-of-plane flow such as at the outlet of the superior vena cava valve at the point of valve closure. The results also showed that the RSS in the vicinity of the valves were relatively low (∼150 dynes/cm2) with the exception of that in the leakage jet at the upstream of the valve. The leakage in the leaflets could be a result of the use of aortic valve leaflets which was more suited for the higher pressured environment of the left side of the heart. The stent design could also be customised for implantation in the vena cava. In summary, these issues could be eradicated with improvements to the leaflet and stent design which would enhance the haemodynamics of the post-implantation flow performance.


Assuntos
Próteses Valvulares Cardíacas , Hemodinâmica , Reologia , Humanos , Imageamento Tridimensional , Desenho de Prótese , Estresse Mecânico , Insuficiência da Valva Tricúspide/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA