Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 496
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39216096

RESUMO

BACKGROUND: One third of patients undergoing transcatheter aortic-valve implantation (TAVI) have an indication for oral anticoagulation owing to concomitant diseases. Interruption of oral anticoagulation during TAVI may decrease the risk of bleeding, whereas continuation may decrease the risk of thromboembolism. METHODS: We conducted an international, open-label, randomized, noninferiority trial involving patients who were receiving oral anticoagulants and were planning to undergo TAVI. Patients were randomly assigned in a 1:1 ratio to periprocedural continuation or interruption of oral anticoagulation. The primary outcome was a composite of death from cardiovascular causes, stroke from any cause, myocardial infarction, major vascular complications, or major bleeding within 30 days after TAVI. RESULTS: A total of 858 patients were included in the modified intention-to-treat population: 431 were assigned to continuation and 427 to interruption of oral anticoagulation. A primary-outcome event occurred in 71 patients (16.5%) in the continuation group and in 63 (14.8%) in the interruption group (risk difference, 1.7 percentage points; 95% confidence interval [CI], -3.1 to 6.6; P = 0.18 for noninferiority). Thromboembolic events occurred in 38 patients (8.8%) in the continuation group and in 35 (8.2%) in the interruption group (risk difference, 0.6 percentage points; 95% CI, -3.1 to 4.4). Bleeding occurred in 134 patients (31.1%) in the continuation group and in 91 (21.3%) in the interruption group (risk difference, 9.8 percentage points; 95% CI, 3.9 to 15.6). CONCLUSIONS: In patients undergoing TAVI with a concomitant indication for oral anticoagulation, periprocedural continuation was not noninferior to interruption of oral anticoagulation during TAVI with respect to the incidence of a composite of death from cardiovascular causes, stroke, myocardial infarction, major vascular complications, or major bleeding at 30 days. (Funded by the Netherlands Organization for Health Research and Development and the St. Antonius Research Fund; POPular PAUSE TAVI ClinicalTrials.gov number, NCT04437303.).

2.
N Engl J Med ; 389(15): 1380-1389, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37634135

RESUMO

BACKGROUND: The role of catheter ablation in patients with symptomatic atrial fibrillation and end-stage heart failure is unknown. METHODS: We conducted a single-center, open-label trial in Germany that involved patients with symptomatic atrial fibrillation and end-stage heart failure who were referred for heart transplantation evaluation. Patients were assigned to receive catheter ablation and guideline-directed medical therapy or medical therapy alone. The primary end point was a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation. RESULTS: A total of 97 patients were assigned to the ablation group and 97 to the medical-therapy group. The trial was stopped for efficacy by the data and safety monitoring board 1 year after randomization was completed. Catheter ablation was performed in 81 of 97 patients (84%) in the ablation group and in 16 of 97 patients (16%) in the medical-therapy group. After a median follow-up of 18.0 months (interquartile range, 14.6 to 22.6), a primary end-point event had occurred in 8 patients (8%) in the ablation group and in 29 patients (30%) in the medical-therapy group (hazard ratio, 0.24; 95% confidence interval [CI], 0.11 to 0.52; P<0.001). Death from any cause occurred in 6 patients (6%) in the ablation group and in 19 patients (20%) in the medical-therapy group (hazard ratio, 0.29; 95% CI, 0.12 to 0.72). Procedure-related complications occurred in 3 patients in the ablation group and in 1 patient in the medical-therapy group. CONCLUSIONS: Among patients with atrial fibrillation and end-stage heart failure, the combination of catheter ablation and guideline-directed medical therapy was associated with a lower likelihood of a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation than medical therapy alone. (Funded by Else Kröner-Fresenius-Stiftung; CASTLE-HTx ClinicalTrials.gov number, NCT04649801.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Alemanha , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Encaminhamento e Consulta , Resultado do Tratamento
3.
Eur Heart J ; 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39378245

RESUMO

BACKGROUND AND AIMS: Risk stratification of sudden cardiac death after myocardial infarction and prevention by defibrillator rely on left ventricular ejection fraction (LVEF). Improved risk stratification across the whole LVEF range is required for decision-making on defibrillator implantation. METHODS: The analysis pooled 20 data sets with 140 204 post-myocardial infarction patients containing information on demographics, medical history, clinical characteristics, biomarkers, electrocardiography, echocardiography, and cardiac magnetic resonance imaging. Separate analyses were performed in patients (i) carrying a primary prevention cardioverter-defibrillator with LVEF ≤ 35% [implantable cardioverter-defibrillator (ICD) patients], (ii) without cardioverter-defibrillator with LVEF ≤ 35% (non-ICD patients ≤ 35%), and (iii) without cardioverter-defibrillator with LVEF > 35% (non-ICD patients >35%). Primary outcome was sudden cardiac death or, in defibrillator carriers, appropriate defibrillator therapy. Using a competing risk framework and systematic internal-external cross-validation, a model using LVEF only, a multivariable flexible parametric survival model, and a multivariable random forest survival model were developed and externally validated. Predictive performance was assessed by random effect meta-analysis. RESULTS: There were 1326 primary outcomes in 7543 ICD patients, 1193 in 25 058 non-ICD patients ≤35%, and 1567 in 107 603 non-ICD patients >35% during mean follow-up of 30.0, 46.5, and 57.6 months, respectively. In these three subgroups, LVEF poorly predicted sudden cardiac death (c-statistics between 0.50 and 0.56). Considering additional parameters did not improve calibration and discrimination, and model generalizability was poor. CONCLUSIONS: More accurate risk stratification for sudden cardiac death and identification of low-risk individuals with severely reduced LVEF or of high-risk individuals with preserved LVEF was not feasible, neither using LVEF nor using other predictors.

4.
Ann Intern Med ; 176(6): 737-742, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37247416

RESUMO

BACKGROUND: Osteoarthritis is a major contributor to pain and disability worldwide. Given that inflammation plays an important role in the development of osteoarthritis, anti-inflammatory drugs may slow disease progression. OBJECTIVE: To examine whether colchicine, 0.5 mg daily, reduces incident total knee replacements (TKRs) and total hip replacements (THRs). DESIGN: Exploratory analysis of the LoDoCo2 (Low-Dose Colchicine 2) randomized, controlled, double-blind trial. (Australian New Zealand Clinical Trials Registry: ACTRN12614000093684). SETTING: 43 centers in Australia and the Netherlands. PATIENTS: 5522 patients with chronic coronary artery disease. INTERVENTION: Colchicine, 0.5 mg, or placebo once daily. MEASUREMENTS: The primary outcome was time to first TKR or THR since randomization. All analyses were performed on an intention-to-treat basis. RESULTS: A total of 2762 patients received colchicine and 2760 received placebo during a median follow-up of 28.6 months. During the trial, TKR or THR was performed in 68 patients (2.5%) in the colchicine group and 97 (3.5%) in the placebo group (incidence rate, 0.90 vs. 1.30 per 100 person-years; incidence rate difference, -0.40 [95% CI, -0.74 to -0.06] per 100 person-years; hazard ratio, 0.69 [CI, 0.51 to 0.95]). In sensitivity analyses, similar results were obtained when patients with gout at baseline were excluded and when joint replacements that occurred in the first 3 and 6 months of follow-up were omitted. LIMITATION: LoDoCo2 was not designed to investigate the effect of colchicine in osteoarthritis of the knee or hip and did not collect information specifically on osteoarthritis. CONCLUSION: In this exploratory analysis of the LoDoCo2 trial, use of colchicine, 0.5 mg daily, was associated with a lower incidence of TKR and THR. Further investigation of colchicine therapy to slow disease progression in osteoarthritis is warranted. PRIMARY FUNDING SOURCE: None.


Assuntos
Artroplastia de Quadril , Osteoartrite do Joelho , Osteoartrite , Humanos , Colchicina/efeitos adversos , Incidência , Austrália/epidemiologia , Método Duplo-Cego , Progressão da Doença , Osteoartrite/tratamento farmacológico , Osteoartrite do Joelho/tratamento farmacológico , Osteoartrite do Joelho/cirurgia
5.
Circulation ; 145(5): 321-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779221

RESUMO

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
6.
N Engl J Med ; 382(2): 120-129, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31733180

RESUMO

BACKGROUND: Whether the direct factor Xa inhibitor rivaroxaban can prevent thromboembolic events after transcatheter aortic-valve replacement (TAVR) is unclear. METHODS: We randomly assigned 1644 patients without an established indication for oral anticoagulation after successful TAVR to receive rivaroxaban at a dose of 10 mg daily (with aspirin at a dose of 75 to 100 mg daily for the first 3 months) (rivaroxaban group) or aspirin at a dose of 75 to 100 mg daily (with clopidogrel at a dose of 75 mg daily for the first 3 months) (antiplatelet group). The primary efficacy outcome was the composite of death or thromboembolic events. The primary safety outcome was major, disabling, or life-threatening bleeding. The trial was terminated prematurely by the data and safety monitoring board because of safety concerns. RESULTS: After a median of 17 months, death or a first thromboembolic event (intention-to-treat analysis) had occurred in 105 patients in the rivaroxaban group and in 78 patients in the antiplatelet group (incidence rates, 9.8 and 7.2 per 100 person-years, respectively; hazard ratio with rivaroxaban, 1.35; 95% confidence interval [CI], 1.01 to 1.81; P = 0.04). Major, disabling, or life-threatening bleeding (intention-to-treat analysis) had occurred in 46 and 31 patients, respectively (4.3 and 2.8 per 100 person-years; hazard ratio, 1.50; 95% CI, 0.95 to 2.37; P = 0.08). A total of 64 deaths occurred in the rivaroxaban group and 38 in the antiplatelet group (5.8 and 3.4 per 100 person-years, respectively; hazard ratio, 1.69; 95% CI, 1.13 to 2.53). CONCLUSIONS: In patients without an established indication for oral anticoagulation after successful TAVR, a treatment strategy including rivaroxaban at a dose of 10 mg daily was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than an antiplatelet-based strategy. (Funded by Bayer and Janssen Pharmaceuticals; GALILEO ClinicalTrials.gov number, NCT02556203.).


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/uso terapêutico , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Feminino , Próteses Valvulares Cardíacas , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Rivaroxabana/efeitos adversos , Tromboembolia/mortalidade
7.
N Engl J Med ; 383(19): 1838-1847, 2020 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-32865380

RESUMO

BACKGROUND: Evidence from a recent trial has shown that the antiinflammatory effects of colchicine reduce the risk of cardiovascular events in patients with recent myocardial infarction, but evidence of such a risk reduction in patients with chronic coronary disease is limited. METHODS: In a randomized, controlled, double-blind trial, we assigned patients with chronic coronary disease to receive 0.5 mg of colchicine once daily or matching placebo. The primary end point was a composite of cardiovascular death, spontaneous (nonprocedural) myocardial infarction, ischemic stroke, or ischemia-driven coronary revascularization. The key secondary end point was a composite of cardiovascular death, spontaneous myocardial infarction, or ischemic stroke. RESULTS: A total of 5522 patients underwent randomization; 2762 were assigned to the colchicine group and 2760 to the placebo group. The median duration of follow-up was 28.6 months. A primary end-point event occurred in 187 patients (6.8%) in the colchicine group and in 264 patients (9.6%) in the placebo group (incidence, 2.5 vs. 3.6 events per 100 person-years; hazard ratio, 0.69; 95% confidence interval [CI], 0.57 to 0.83; P<0.001). A key secondary end-point event occurred in 115 patients (4.2%) in the colchicine group and in 157 patients (5.7%) in the placebo group (incidence, 1.5 vs. 2.1 events per 100 person-years; hazard ratio, 0.72; 95% CI, 0.57 to 0.92; P = 0.007). The incidence rates of spontaneous myocardial infarction or ischemia-driven coronary revascularization (composite end point), cardiovascular death or spontaneous myocardial infarction (composite end point), ischemia-driven coronary revascularization, and spontaneous myocardial infarction were also significantly lower with colchicine than with placebo. The incidence of death from noncardiovascular causes was higher in the colchicine group than in the placebo group (incidence, 0.7 vs. 0.5 events per 100 person-years; hazard ratio, 1.51; 95% CI, 0.99 to 2.31). CONCLUSIONS: In a randomized trial involving patients with chronic coronary disease, the risk of cardiovascular events was significantly lower among those who received 0.5 mg of colchicine once daily than among those who received placebo. (Funded by the National Health Medical Research Council of Australia and others; LoDoCo2 Australian New Zealand Clinical Trials Registry number, ACTRN12614000093684.).


Assuntos
Anti-Inflamatórios/uso terapêutico , Colchicina/uso terapêutico , Doença das Coronárias/tratamento farmacológico , Idoso , Anti-Inflamatórios/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Doença Crônica , Colchicina/efeitos adversos , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Incidência , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais
8.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-32757521

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Idoso , Cardiomiopatias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Feminino , Seguimentos , Cardiopatias/terapia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
9.
Am Heart J ; 260: 1-8, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36796573

RESUMO

BACKGROUND: Physiological assessment of intermediate coronary lesions to guide coronary revascularization is currently recommended by international guidelines. Vessel fractional flow reserve (vFFR) has emerged as a new approach to derive fractional flow reserve (FFR) from 3D-quantitative coronary angiography (3D-QCA) without the need for hyperemic agents or pressure wires. STUDY DESIGN AND OBJECTIVES: The FAST III is an investigator-initiated, open label, multicenter randomized trial comparing vFFR guided versus FFR guided coronary revascularization in approximately 2228 patients with intermediate coronary lesions (defined as 30%-80% stenosis by visual assessment or QCA). Intermediate lesions are physiologically assessed using on-line vFFR or FFR and treated if vFFR or FFR ≤0.80. The primary end point is a composite of all-cause death, any myocardial infarction, or any revascularization at 1-year post-randomization. Secondary end points include the individual components of the primary end point and cost-effectiveness will be investigated. CONCLUSIONS: FAST III is the first randomized trial to explore whether a vFFR guided revascularization strategy is non-inferior to an FFR guided strategy in terms of clinical outcomes at 1-year follow-up in patients with intermediate coronary artery lesions.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Estudos Prospectivos , Seguimentos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia
10.
Am Heart J ; 266: 168-175, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37806333

RESUMO

The optimal treatment strategy for coronary bifurcation lesions by percutaneous coronary intervention (PCI) is complex and remains a subject of debate. Current guidelines advise a stepwise provisional approach with optional two-stent strategy. However, a two-stent strategy, both upfront and stepwise provisional, is technically demanding. Therefore, there is increasing interest in the use of drug-eluting balloons (DEB) in bifurcation lesions, mainly after a provisional approach with unsatisfactory result of the side branch. Some small pilot studies already showed that the use of DEB in bifurcation lesions is safe and feasible. However, a randomized comparison of this hybrid DEB strategy with a two-stent strategy is currently lacking. TRIAL DESIGN: The Hybrid DEB study is a prospective, multicenter, randomized controlled trial investigating noninferiority of a hybrid DEB approach, using a combination of a drug-eluting stent (DES) in the main vessel and DEB in the side branch, compared to stepwise provisional two-stent strategy in patients with true bifurcation lesions. A total of 500 patients with de novo true coronary bifurcation lesions, treated with a stepwise provisional approach and an unsatisfactory result of the side branch after main vessel stenting (≥ 70% stenosis and/or < thrombolysis in myocardial infarction III flow), will be randomized in a 1:1 ratio to receive either treatment with a DEB or with a DES in the side branch. The primary endpoint is a composite endpoint of the occurrence of all-cause death, periprocedural or spontaneous myocardial infarction and/or target vessel revascularization at the anticipated median 2-year follow-up. CONCLUSION: The Hybrid DEB study will compare in a multicenter, randomized fashion a hybrid DEB approach with a stepwise provisional two-stent strategy in patients with true bifurcation lesions. TRIAL REGISTRATION: ClinicalTrials.gov no. NCT05731687.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Stents Farmacológicos/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Estudos Prospectivos , Angiografia Coronária/efeitos adversos , Stents/efeitos adversos , Infarto do Miocárdio/etiologia , Resultado do Tratamento , Doença da Artéria Coronariana/complicações
11.
Catheter Cardiovasc Interv ; 102(2): 273-280, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37221985

RESUMO

BACKGROUND: NobleStitch EL is a novel suture-based technique used for patent foramen ovale (PFO) closure and an alternative to traditional double-disc devices without the need for antithrombotic therapy. However, successful closure rates are still unknown, and certain anatomies may be unfavorable for successful closure. AIMS: We assessed the efficacy of the NobleStitch EL and sought to identify patient-related anatomical features associated with successful suture-based closure. METHODS: We included 55 patients who underwent PFO closure with the NobleStitch EL in The Netherlands and Switzerland. Successful closure was defined as residual right-to-left shunt grade ≤1 with Valsalva maneuver at a cardiac ultrasound. Predefined possible anatomical determinants for effective closure included PFO length, atrial septal aneurysm, PFO entry- and exit diameter. RESULTS: Successful closure was achieved in 33 patients (60%). The PFO length was shorter in patients with successful closure compared to unsuccessful closure with a median length of 9.6 mm (IQR 8.0-15.0) versus 13.3 mm (IQR 11.4-18.6) on preprocedural ultrasound (p = 0.041) and 9.9 mm (IQR 8.0-13.1) versus 12.5 mm (IQR 9.7-15.4) on angiography (p = 0.049). Additionally, the PFO exit diameter and PFO volume were smaller in patients with successful closure than unsuccessful closure, with a mean diameter of 7.0 ± 3.1 mm versus 9.5 ± 3.8 mm (p = 0.015) and a median volume of 381 mm3 (IQR 286-894) versus 985 mm3 (IQR 572-1550) (p = 0.016). CONCLUSION: In our study cohort, the successful PFO closure rate using NobleStitch EL was relatively low (60%). With this alternative procedure, patients with a small PFO driven by a short PFO tunnel length and small exit diameter seem to be eligible for successful suture-based closure.


Assuntos
Forame Oval Patente , Acidente Vascular Cerebral , Humanos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia Transesofagiana , Cateterismo Cardíaco , Suturas
12.
Eur Heart J ; 43(15): 1465-1474, 2022 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-34791171

RESUMO

AIMS: Automated external defibrillators (AEDs) are placed in public, but the majority of out-of-hospital cardiac arrests (OHCA) occur at home. METHODS AND RESULTS: In residential areas, 785 AEDs were placed and 5735 volunteer responders were recruited. For suspected OHCA, dispatchers activated nearby volunteer responders with text messages, directing two-thirds to an AED first and one-third directly to the patient. We analysed survival (primary outcome) and neurologically favourable survival to discharge, time to first defibrillation shock, and cardiopulmonary resuscitation (CPR) before Emergency Medical Service (EMS) arrival of patients in residences found with ventricular fibrillation (VF), before and after introduction of this text-message alert system. Survival from OHCAs in residences increased from 26% to 39% {adjusted relative risk (RR) 1.5 [95% confidence interval (CI): 1.03-2.0]}. RR for neurologically favourable survival was 1.4 (95% CI: 0.99-2.0). No CPR before ambulance arrival decreased from 22% to 9% (RR: 0.5, 95% CI: 0.3-0.7). Text-message-responders with AED administered shocks to 16% of all patients in VF in residences, while defibrillation by EMS decreased from 73% to 39% in residences (P < 0.001). Defibrillation by first responders in residences increased from 22 to 40% (P < 0.001). Use of public AEDs in residences remained unchanged (6% and 5%) (P = 0.81). Time from emergency call to defibrillation decreased from median 11.7 to 9.3 min; mean difference -2.6 (95% CI: -3.5 to -1.6). CONCLUSION: Introducing volunteer responders directed to AEDs, dispatched by text-message was associated with significantly reduced time to first defibrillation, increased bystander CPR and increased overall survival for OHCA patients in residences found with VF.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Desfibriladores , Cardioversão Elétrica , Humanos , Parada Cardíaca Extra-Hospitalar/terapia , Fibrilação Ventricular/terapia
13.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36030464

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos
14.
N Engl J Med ; 380(16): 1499-1508, 2019 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-30883054

RESUMO

BACKGROUND: Patients with recent-onset atrial fibrillation commonly undergo immediate restoration of sinus rhythm by pharmacologic or electrical cardioversion. However, whether immediate restoration of sinus rhythm is necessary is not known, since atrial fibrillation often terminates spontaneously. METHODS: In a multicenter, randomized, open-label, noninferiority trial, we randomly assigned patients with hemodynamically stable, recent-onset (<36 hours), symptomatic atrial fibrillation in the emergency department to be treated with a wait-and-see approach (delayed-cardioversion group) or early cardioversion. The wait-and-see approach involved initial treatment with rate-control medication only and delayed cardioversion if the atrial fibrillation did not resolve within 48 hours. The primary end point was the presence of sinus rhythm at 4 weeks. Noninferiority would be shown if the lower limit of the 95% confidence interval for the between-group difference in the primary end point in percentage points was more than -10. RESULTS: The presence of sinus rhythm at 4 weeks occurred in 193 of 212 patients (91%) in the delayed-cardioversion group and in 202 of 215 (94%) in the early-cardioversion group (between-group difference, -2.9 percentage points; 95% confidence interval [CI], -8.2 to 2.2; P = 0.005 for noninferiority). In the delayed-cardioversion group, conversion to sinus rhythm within 48 hours occurred spontaneously in 150 of 218 patients (69%) and after delayed cardioversion in 61 patients (28%). In the early-cardioversion group, conversion to sinus rhythm occurred spontaneously before the initiation of cardioversion in 36 of 219 patients (16%) and after cardioversion in 171 patients (78%). Among the patients who completed remote monitoring during 4 weeks of follow-up, a recurrence of atrial fibrillation occurred in 49 of 164 patients (30%) in the delayed-cardioversion group and in 50 of 171 (29%) in the early-cardioversion group. Within 4 weeks after randomization, cardiovascular complications occurred in 10 patients and 8 patients, respectively. CONCLUSIONS: In patients presenting to the emergency department with recent-onset, symptomatic atrial fibrillation, a wait-and-see approach was noninferior to early cardioversion in achieving a return to sinus rhythm at 4 weeks. (Funded by the Netherlands Organization for Health Research and Development and others; RACE 7 ACWAS ClinicalTrials.gov number, NCT02248753.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Tempo para o Tratamento , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Digoxina/uso terapêutico , Cardioversão Elétrica/efeitos adversos , Serviço Hospitalar de Emergência , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recidiva , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 100(4): 636-645, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36040717

RESUMO

BACKGROUND: Midterm data comparing clinical outcomes after successful implantation of self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. We aimed to compare 2-year outcomes after successful transcatheter aortic valve implantation (TAVI) with the Edwards balloon-expandable or the Medtronic self-expanding THV. METHODS: Two-year outcomes were analyzed according to the implanted THV in the GALILEO trial. Major adverse cardiac and cerebrovascular events (MACCE) was a composite of all-cause death or thromboembolic events including stroke, myocardial infarction, symptomatic valve thrombosis, systemic embolism, deep-vein thrombosis, or pulmonary embolism. RESULTS: Among 1644 patients recruited in 136 centers across 16 countries between 2015 and 2018, 499 received a self-expanding and 757 patients received a balloon-expandable THV. Patients treated with a self-expanding THV were more likely to be female, and had higher surgical risk, lower hemoglobin levels, and more frequent valve-in-valve procedures than those with a balloon-expandable THV. After multivariable adjustment, there were no significant differences in major clinical outcomes between self-expanding versus balloon-expandable THV: MACCE (17.0% vs. 13.4%, adjusted-hazard ratios [HR] 1.18, 95% confidence intervals [CI]: 0.82-1.69); all-cause death (11.4% vs. 9.3%, adjusted-HR 1.26; 95% CI: 0.78-2.05); cardiovascular death (8.5% vs. 4.0%, adjusted-HR 1.53; 95% CI: 0.82-2.86), any stroke (5.1% vs. 3.7%, adjusted-HR 0.86; 95% CI: 0.43-1.73); major or life-threatening bleeding (5.9% vs. 6.8%, adjusted-HR 0.93; 95% CI: 0.53-1.63). CLINICAL TRIAL REGISTRATION: https://www. CLINICALTRIALS: gov. NCT02556203. CONCLUSIONS: Two-year follow-up data from the GALILEO trial indicate that successful TAVI either with self-expanding or balloon-expandable THVs according to physician discretion did not show difference in rates of MACCE.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Hemoglobinas , Humanos , Masculino , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
Europace ; 24(6): 910-920, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34791160

RESUMO

AIMS: The Routine vs. Aggressive risk factor driven upstream rhythm Control for prevention of Early persistent atrial fibrillation (AF) in heart failure (HF) (RACE 3) trial demonstrated that targeted therapy of underlying conditions improved sinus rhythm maintenance at 1 year. We now explored the effects of targeted therapy on the additional co-primary endpoints; sinus rhythm maintenance and cardiovascular outcome at 5 years. METHODS AND RESULTS: Patients with early persistent AF and mild-to-moderate stable HF were randomized to targeted or conventional therapy. Both groups received rhythm control therapy according to guidelines. The targeted group additionally received four therapies: angiotensin-converting enzyme inhibitors and/or angiotensin receptor blockers (ARBs), statins, mineralocorticoid receptor antagonists (MRAs), and cardiac rehabilitation. The presence of sinus rhythm and cardiovascular morbidity and mortality at 5-year follow-up were assessed. Two hundred and sixteen patients consented for long-term follow-up, 107 were randomized to targeted and 109 to conventional therapy. At 5 years, MRAs [76 (74%) vs. 10 (9%) patients, P < 0.001] and statins [81 (79%) vs. 59 (55%), P < 0.001] were used more in the targeted than conventional group. Angiotensin-converting enzyme inhibitors/ARBs and physical activity were not different between groups. Sinus rhythm was present in 49 (46%) targeted vs. 43 (39%) conventional group patients at 5 years (odds ratio 1.297, lower limit of 95% confidence interval 0.756, P = 0.346). Cardiovascular mortality and morbidity occurred in 20 (19%) in the targeted and 15 (14%) conventional group patients, P = 0.353. CONCLUSION: In patients with early persistent AF and HF superiority of targeted therapy in sinus rhythm maintenance could not be preserved at 5-year follow-up. Cardiovascular outcome was not different between groups. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov NCT00877643.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Inibidores de Hidroximetilglutaril-CoA Redutases , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Resultado do Tratamento
17.
Europace ; 24(3): 384-389, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34414430

RESUMO

AIMS: We hypothesize that in patients with paroxysmal atrial fibrillation (AF), verapamil is associated with lower AF progression compared to beta blockers or no rate control. METHODS AND RESULTS: In this pre-specified post hoc analysis of the RACE 4 randomized trial, the effect of rate control medication on AF progression in paroxysmal AF was analysed. Patients using Vaughan-Williams Class I or III antiarrhythmic drugs were excluded. The primary outcome was a composite of first electrical cardioversion (ECV), chemical cardioversion (CCV), or atrial ablation. Event rates are displayed using Kaplan-Meier curves and multivariable Cox regression analyses are used to adjust for baseline differences. Out of 666 patients with paroxysmal AF, 47 used verapamil, 383 used beta blockers, and 236 did not use rate control drugs. The verapamil group was significantly younger than the beta blocker group and contained more men than the no rate control group. Over a mean follow-up of 37 months, the primary outcome occurred in 17% in the verapamil group, 33% in the beta blocker group, and 33% in the no rate control group (P = 0.038). After adjusting for baseline characteristics, patients using verapamil have a significantly lower chance of receiving ECV, CCV, or atrial ablation compared to patients using beta blockers [hazard ratio (HR) 0.40, 95% confidence interval (CI) 0.19-0.83] and no rate control (HR 0.64, 95% CI 0.44-0.93). CONCLUSION: In patients with newly diagnosed paroxysmal AF, verapamil was associated with less AF progression, as compared to beta blockers and no rate control.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Humanos , Masculino , Resultado do Tratamento
18.
Eur Heart J ; 42(28): 2765-2775, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-33769515

RESUMO

AIMS: Recent randomized trials demonstrated a benefit of low-dose colchicine added to guideline-based treatment in patients with recent myocardial infarction or chronic coronary disease. We performed a systematic review and meta-analysis to obtain best estimates of the effects of colchicine on major adverse cardiovascular events (MACE). METHODS AND RESULTS: We searched the literature for randomized clinical trials of long-term colchicine in patients with atherosclerosis published up to 1 September 2020. The primary efficacy endpoint was MACE, the composite of myocardial infarction, stroke, or cardiovascular death. We combined the results of five trials that included 11 816 patients. The primary endpoint occurred in 578 patients. Colchicine reduced the risk for the primary endpoint by 25% [relative risk (RR) 0.75, 95% confidence interval (CI) 0.61-0.92; P = 0.005], myocardial infarction by 22% (RR 0.78, 95% CI 0.64-0.94; P = 0.010), stroke by 46% (RR 0.54, 95% CI 0.34-0.86; P = 0.009), and coronary revascularization by 23% (RR 0.77, 95% CI 0.66-0.90; P < 0.001). We observed no difference in all-cause death (RR 1.08, 95% CI 0.71-1.62; P = 0.73), with a lower incidence of cardiovascular death (RR 0.82, 95% CI 0.55-1.23; P = 0.34) counterbalanced by a higher incidence of non-cardiovascular death (RR 1.38, 95% CI 0.99-1.92; P = 0.060). CONCLUSION: Our meta-analysis indicates that low-dose colchicine reduced the risk of MACE as well as that of myocardial infarction, stroke, and the need for coronary revascularization in a broad spectrum of patients with coronary disease. There was no difference in all-cause mortality and fewer cardiovascular deaths were counterbalanced by more non-cardiovascular deaths.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Acidente Vascular Cerebral , Colchicina/efeitos adversos , Doença da Artéria Coronariana/tratamento farmacológico , Humanos , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
19.
Circulation ; 142(19): 1799-1807, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-32862716

RESUMO

BACKGROUND: Approximately 15% of saphenous vein grafts (SVGs) occlude during the first year after coronary artery bypass graft surgery (CABG) despite aspirin use. The POPular CABG trial (The Effect of Ticagrelor on Saphenous Vein Graft Patency in Patients Undergoing Coronary Artery Bypass Grafting Surgery) investigated whether ticagrelor added to standard aspirin improves SVG patency at 1 year after CABG. METHODS: In this investigator-initiated, randomized, double-blind, placebo-controlled, multicenter trial, patients with ≥1 SVGs were randomly assigned (1:1) after CABG to ticagrelor or placebo added to standard aspirin (80 mg or 100 mg). The primary outcome was SVG occlusion at 1 year, assessed with coronary computed tomography angiography, in all patients that had primary outcome imaging available. A generalized estimating equation model was used to perform the primary analysis per SVG. The secondary outcome was 1-year SVG failure, which was a composite of SVG occlusion, SVG revascularization, myocardial infarction in myocardial territory supplied by a SVG, or sudden death. RESULTS: Among 499 randomly assigned patients, the mean age was 67.9±8.3 years, 87.1% were male, the indication for CABG was acute coronary syndrome in 31.3%, and 95.2% of procedures used cardiopulmonary bypass. Primary outcome imaging was available in 220 patients in the ticagrelor group and 223 patients in the placebo group. The SVG occlusion rate in the ticagrelor group was 10.5% (51 of 484 SVGs) versus 9.1% in the placebo group (43 of 470 SVGs), odds ratio, 1.29 [95% CI, 0.73-2.30]; P=0.38. SVG failure occurred in 35 (14.2%) patients in the ticagrelor group versus 29 (11.6%) patients in the placebo group (odds ratio, 1.22 [95% CI, 0.72-2.05]). CONCLUSIONS: In this randomized, placebo-controlled trial, the addition of ticagrelor to standard aspirin did not reduce SVG occlusion at 1 year after CABG. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02352402.


Assuntos
Síndrome Coronariana Aguda , Aspirina/administração & dosagem , Angiografia Coronária , Ponte de Artéria Coronária , Oclusão de Enxerto Vascular , Veia Safena/fisiopatologia , Ticagrelor/administração & dosagem , Grau de Desobstrução Vascular/efeitos dos fármacos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/fisiopatologia , Síndrome Coronariana Aguda/cirurgia , Idoso , Aspirina/efeitos adversos , Método Duplo-Cego , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Ticagrelor/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA