1.
Opt Express ; 31(26): 44328-44339, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38178506

RESUMO

We have developed a low-cost micro-diffuse reflectance infrared Fourier transform spectroscopic (micro-DRIFTS) setup for measuring the reflectance of small area diffuse samples. The system performance is characterized and then demonstrated on small area vertically aligned carbon nanotube (VACNT) samples. We find that our system can measure samples with a spatial resolution of approximately 140 µm with sensitivities of 10s of ppm in the 2 µm - 18 µm spectral window. Our uncertainty budget is presented along with how our measured reflectance can be equated to directional-hemispherical reflectance.

2.
Opt Express ; 29(14): 22533-22552, 2021 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-34266014

RESUMO

We have developed a planar absolute radiometer for room temperature (PARRoT) that will replace the legacy C-series calorimeter as the free-space continuous-wave laser power detector standard at the National Institute of Standards and Technology (NIST). This instrument will lower the combined relative expanded measurement uncertainty (k = 2) from 0.84 % to 0.13 %. PARRoT's performance was validated by comparing its response against a transfer standard silicon trap detector traceable to NIST's primary standard laser optimized cryogenic radiometer (LOCR) and against the C-series calorimeter. On average, these comparisons agreed to better than 0.008 % and 0.05 %, respectively.

3.
Opt Express ; 24(23): 25911-25921, 2016 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-27857330

RESUMO

The absolute responsivity of a planar cryogenic radiometer fabricated from micromachined silicon and having carbon nanotubes, as the absorber and thermistor were measured in the visible and far infrared (free-field terahertz) wavelength range by means of detector-based radiometry. The temperature coefficient of the thermistor near 4.8 K and noise equivalent power were evaluated along with independent characterization of the window transmittance and specular reflectance of the nanotube absorber. Measurements of absolute power by means of electrical substitution are compared to the German national standard and the uncertainty of the radiometer responsivity as a function of wavelength is summarized.

4.
Opt Express ; 20(21): 23798-810, 2012 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-23188345

RESUMO

Typically, transition edge sensors resolve photon number of up to 10 or 20 photons, depending on the wavelength and TES design. We extend that dynamic range up to 1000 photons, while maintaining sub-shot noise detection process uncertainty of the number of detected photons and beyond that show a monotonic response up to ≈ 6 · 10(6) photons in a single light pulse. This mode of operation, which heats the sensor far beyond its transition edge into the normal conductive regime, offers a technique for connecting single-photon-counting measurements to radiant-power measurements at picowatt levels. Connecting these two usually incompatible operating regimes in a single detector offers significant potential for directly tying photon counting measurements to conventional cryogenic radiometric standards. In addition, our measurements highlight the advantages of a photon-number state source over a coherent pulse source as a tool for characterizing such a detector.


Assuntos
Fotometria/instrumentação , Transdutores , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons
5.
Rev Sci Instrum ; 88(2): 024707, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28249484

RESUMO

As part of the development of a spectrally uniform room-temperature absolute radiometer, we have studied the electrical noise of several bulk chip thermistors in order to estimate the noise floor and optical dynamic range. Understanding the fundamental limits of the temperature sensitivity leads inevitably to studying the noise background of the complex electro-thermal system. To this end, we employ a measurement technique based on alternating current synchronous demodulation. Results of our analysis show that the combination of a low-current noise Junction Field Effect Transistor (JFET) preamplifier together with chip thermistors is optimal for our purpose, yielding a root mean square noise temperature of 2.8 µK in the frequency range of 0.01 Hz to 1 Hz.