1.
J Appl Lab Med ; 5(2): 290-299, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32445383

RESUMO

BACKGROUND: Asfotase alfa (STRENSIQ®, Alexion Pharmaceuticals, Inc.) is the only approved treatment for patients with pediatric-onset hypophosphatasia, a disease caused by a mutation in the tissue-nonspecific alkaline phosphatase (TNSALP) gene. ALP is often used as signaling system in routine immunoassays. Because asfotase alfa contains the active site of the full ALP enzyme, it can catalyze the substrate as the antibody-conjugated ALP would within an assay. Therefore, its presence in a treated patient's sample may generate false positive or false negative results. We investigated whether the presence of asfotase alfa within a sample induced interference in immunoassays that utilize ALP or alternative detection systems. METHODS: Asfotase alfa was added to samples at concentrations from 0.08-5 µg/mL and analysed on various immunoassays following manufacturer's instructions. RESULTS: Asfotase alfa was detected in all ALP assays but ALKP1 (RayBiotech). We observed no changes in normetanephrine and noradrenaline (IBL) at any asfotase alfa concentration. However, asfotase alfa notably interfered in an oxytocin (ENZO) assay in nonextracted samples. Extraction using a C18 column eliminated the interference. No interference was observed on automated analyzers using alternative detection system (COBAS fT4 and TSH; Advia Centaur FSH, fT4; Architect LH; FSH). Immulite 2000 fT4, TSH, testosterone and hCG (ALP-based) showed no interference. However, the presence of asfotase alfa resulted in a dose-dependent increase of Troponin I signal. CONCLUSION: The presence of asfotase alfa must be taken into consideration when analyzing blood samples in treated patients to avoid any risk of misinterpretation of false positive/negative results. It is essential that assays be tested for this possible interference.


Assuntos
Fosfatase Alcalina/sangue , Hipofosfatasia/sangue , Hipofosfatasia/diagnóstico , Imunoensaio/métodos , Imunoensaio/normas , Imunoglobulina G/efeitos adversos , Proteínas Recombinantes de Fusão/efeitos adversos , Fosfatase Alcalina/efeitos adversos , Fosfatase Alcalina/farmacocinética , Análise de Variância , Biomarcadores/sangue , Ativação Enzimática , Reações Falso-Positivas , Humanos , Hipofosfatasia/etiologia , Proteínas Recombinantes de Fusão/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA