Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Acta Orthop Belg ; 90(1): 17-25, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669644

RESUMO

Today, acetabular surgeons in training have to learn ilioinguinal and anterior intrapelvic approaches (AIP). The aim of this study was to describe the 5-years learning curve of a surgeon. Objective was to assess clinical and radiological results; and to assess factors which could influence this learning curve. Between November 2015 and May 2020, patients with an acetabular fracture operated by the surgeon during the 5-years learning curve with an anterior approach were included in this single-center retrospective study based on a prospective database. Epidemiological, operative, clinical, radiological and complications data's were collected. To assess learning-curve effect the series was divided into two groups: first 2.5-years and last 2-years. Subgroup analysis were performed according to the surgical approach, to the reduction quality and the prognostic factors. In total, 46 patients were included, 23 in period 1 and 23 in period 2. 16 patients (35%) had ilioinguinal approach and 30 patients (65%) had modified Stoppa-Cole approach. At mean follow-up of 24 months, 38 patients (83%) were reviewed. Anatomical reduction (< 1 mm) was achieved in 28 patients (60.9%) with a 9% rate of perioperative complications and 37% rate of post-operative complications. In conclusion, this study gives a realistic overview of the learning curve of anterior approaches in acetabular fractures surgery. Our results should encourage surgeons, while keeping in mind how much this surgery can be challenging, with high rate of complications and difficulty to obtain a systematic anatomical reduction.


Assuntos
Acetábulo , Fraturas Ósseas , Curva de Aprendizado , Humanos , Acetábulo/lesões , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Masculino , Feminino , Estudos Retrospectivos , Fraturas Ósseas/cirurgia , Pessoa de Meia-Idade , Adulto , Fixação Interna de Fraturas/métodos , Complicações Pós-Operatórias/epidemiologia , Idoso
2.
Int Orthop ; 44(6): 1209-1215, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32328739

RESUMO

PURPOSES: The aim of this study was to evaluate: 1. the outcome of pelvic ring fractures treated by closed reduction and percutaneous fixation, 2. the prognostic factors associated with a poor quality reduction, 3. the prognostic factors associated with ilio-sacral screws misplacement and 4. the prognostic factors associated with nonunion. METHODS: Data from medical charts for all patients admitted with unstable posterior pelvic ring injuries from 2009 to 2013 were extracted. A total of 165 patients with a mean age of 40 years were included. One hundred and five patients were reviewed at a mean of 32 months of follow-up. The prognostic factors analyzed were clinical and radiological factors. Tile B and Tile C pelvic ring fractures were compared and analyzed separately. Then specific statistical analysis was performed using a logistic regression model to eliminate confusion factors. RESULTS: An excellent or good clinical result was achieved for 94 patients (90%). An excellent or good reduction was achieved for 141 patients (85%). Nonunion rate, smoking patients, bad reductions, age of patients and ISS score were significantly higher in Tile C group. To eliminate confusion factors we used a multivariate analysis logistic regression model. Only unstable vertical bilateral posterior injuries (Tile C2 and C3) were independent prognostic factors for unsatisfactory reduction (p = 0.001; OR = 4.72; CI 95% [2.08-16.72]). Screw misplacement was recorded for 30 patients (16%) and sacral dysmorphia was an associated prognostic factor (p = 0.0001; OR = 15.6; CI95% [3.41-98.11]). Nonunion was recorded for ten patients (6%) and smoking was an associated prognostic factor (p = 0.01, OR = 5.12; CI95% [1.1-24.1]). CONCLUSIONS: Posterior pelvic ring fractures treated by closed reduction and percutaneous fixation are associated with excellent/good clinical results if excellent/good reduction and bone healing are achieved without screw misplacement. Bilateral unstable vertical posterior pelvic ring injuries, and sacral dysmorphia are risk factors for bad quality reduction and screw misplacement respectively.


Assuntos
Ossos Pélvicos/lesões , Adulto , Parafusos Ósseos/efeitos adversos , Feminino , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Radiografia , Procedimentos de Cirurgia Plástica , Estudos Retrospectivos , Sacro/cirurgia
3.
Eur Spine J ; 25(6): 1738-44, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26210308

RESUMO

PURPOSE: We report a single-center, prospective, randomized study for pedicle screw insertion in opened and percutaneous spine surgeries, using a computer-assisted surgery (CAS) technique with three-dimensional (3D) intra-operative images intensifier (without planification on pre-operative CT scan) vs conventional surgical procedure. MATERIAL AND METHOD: We included 143 patients: Group C (conventional, 72 patients) and Group N (3D Fluoronavigation, 71 patients). We measured the pedicle screw running time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary by two independent radiologists on a post-operative CT scan. RESULTS: 3D Fluoronavigation appeared less accurate in percutaneous procedures (24 % of misplaced pedicle screws vs 5 % in Group C) (p = 0.007), but more accurate in opened surgeries (5 % of misplaced pedicle screws vs 17 % in Group C) (p = 0.025). For one vertebra, the average surgical running time reached 8 min in Group C vs 21 min in Group N for percutaneous surgeries (p = 3.42 × 10(-9)), 7.33 min in Group C vs 16.33 min in Group N (p = 2.88 × 10(-7)) for opened surgeries. The 3D navigation device delivered less radiation in percutaneous procedures [0.6 vs 1.62 mSv in Group C (p = 2.45 × 10(-9))]. For opened surgeries, it was twice higher in Group N with 0.21 vs 0.1 mSv in Group C (p = 0.022). CONCLUSION: The rate of misplaced pedicle screws with conventional techniques was nearly the same as most papers and a little bit higher with CAS. Surgical running time and radiation exposure were consistent with many studies. Our work hypothesis is partially confirmed, depending on the type of surgery (opened or closed procedure).


Assuntos
Imageamento Tridimensional/métodos , Procedimentos Ortopédicos/métodos , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Parafusos Pediculares , Estudos Prospectivos
4.
Trauma Case Rep ; 42: 100731, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36386428

RESUMO

Case: We report a case of a 79-years old man who sustained a Fragility Fracture of the Pelvis (FFP) classified type IVb according to Rommens and Hofmann. After a delayed diagnosis with persistence of pain and loss of mobility, a bilateral sacroplasty was performed. Although pain relief was achieved, a fracture progression (FP) occurred with bilateral neurologic compression of L5 and S1 nerve roots with pain recurrence. A percutaneous ilio-lumbar reduction was attempted with cemented augmentation and bilateral ilio-sacral screwing. Reduction was not achieved and screws finally pulled-out. The patient died one year after institutionalization with a significant loss of mobility and autonomy. Conclusions: Misunderstanding in management of FFP according to Rommens and Hofmann recommendations can lead to bad results with fracture progression, implants failure, pain recurrence, loss of function, loss of autonomy and finally death of the patient.

5.
J Wrist Surg ; 8(3): 215-220, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31192043

RESUMO

Purpose Giant cell tumor of the distal radius are frequent lesions, and different types of surgeries have been described. Functional results, after conservative treatment or arthrodesis, often find a decreased strength and range of motion. The sacrifice of the distal radioulnar joint could be one of the causes. We report the case of a 26-year-old patient who presented with a Campanacci Grade III giant cell tumor of the distal radius. We managed his case by the association of en bloc resection and allograft reconstruction with the preservation of distal radioulnar joint. Hypothesis This procedure could improve functional results, without increasing the risk of recurrence at 2 years follow-up. Case Report The originality of our technique was the possibility of distal radioulnar joint conservation. We preserved a long portion of cortex bone all through the ulnar side of the distal radius. We then used an allograft of distal radius, fixed by a reconstruction anatomical plate. Results At 2 years follow-up, the range of motion was 100° with 60° of palmar flexion, 40° of extension, 75° of pronation, and 70° of supination. Radial and ulnar inclination were 10 and 15°, respectively. MTS (Musculoskeletal Tumor Society Score) 1993 was 88% and DASH score was 6. Concerning grip strength, it was measured at 85% in comparison with the other side. Pronation and supination strengths were 80 and 73%, respectively, in comparison with the other side. At follow-up, standard X-rays showed no recurrence. The allograft was well integrated. Conclusion Conservative treatment of the distal radioulnar joint allowed an almost ad integrum recovery, concerning strengths and range of motion. It allows a better functional recovery, without increasing the risk of recurrence.

6.
Case Rep Orthop ; 2019: 7626454, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31011459

RESUMO

We hereby describe a minimally invasive resection of a T1 pedicular osteoid osteoma next to the vertebral canal. The patient had an 18-month report of painful radiculopathy. We performed the surgery under 3D imaging guidance using navigation with an all-in-one device. Full procedure irradiation was 1.17 mSv for a 181-picture acquisition. Complete operative time incision to closure was 58 minutes. Despite sparing the vertebral stability without any fixation, the tumor resection was well-margined, thanks to the focused guidance. After surgery, the patient had complete relief of his symptoms at the 6-month follow-up. 3D imaging system coupled to navigation made the procedure safe without consuming time. The single Surgivisio® device allows comfortable 3D minimally invasive spine navigation surgery with the ergonomics of a C-arm.

7.
Clin Biomech (Bristol, Avon) ; 23(7): 900-10, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18522864

RESUMO

BACKGROUND: Optimizing patellar tracking in total knee arthroplasty is a surgical priority. Despite this, a comparison of the effects of different component placements on patellar tracking is not available; the biomechanical impact of the patellar resection angle has not been studied; and the similarity between intraoperative and postoperative effects, fundamental to improving patellar tracking, is unknown. Our objective was to compare the impact of the major controllable femoral, tibial and patellar component positions on patellar kinematics during both passive and loaded flexion. METHODS: We tested eight cadaveric knee specimens in two rigs, simulating intraoperative and weightbearing flexion. Optoelectronic marker arrays were attached to the femur, tibia and patella to record kinematics throughout the range of motion. We modified posterior-stabilized fixed-bearing knee components to allow for five types of variations in component placement in addition to the neutral position: femoral component rotation, tibial component rotation, patellar resection angle, patellar component medialization and additional patellar thickness, for a total of 11 individual variations. FINDINGS: The major determinants of patellar tilt and shift were patellar component medialization, patellar resection angle and femoral component rotation. The relative order of these variables depended on the structure (bone or component), kinematic parameter (tilt or shift) and flexion angle (early or late flexion). Effects of component changes were consistent between the intraoperative and weightbearing rigs. INTERPRETATION: To improve patellar tracking, and thereby the clinical outcome, surgeons should focus on patellar component medialization, patellar resection angle and femoral component rotation. These have been linked with anterior knee pain as well. Neither tibial component rotation nor patellar thickness should be adjusted to improve patellar tracking.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Modelos Biológicos , Exame Físico/métodos , Amplitude de Movimento Articular , Simulação por Computador , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Clin Biomech (Bristol, Avon) ; 23(1): 60-70, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17950965

RESUMO

BACKGROUND: During knee replacement surgery, surgeons optimize intraoperative patellar tracking with the aim of optimizing postoperative tracking. This link has not been investigated to date. Our research questions were: (1) How well do patellar kinematics correlate between passive and weightbearing flexion across numerous changes in component placement? (2) How do the kinematics differ between the two loading configurations? METHODS: Eight cadaveric knee joints with modified knee components that allowed 11 different femoral, tibial and patellar placements were tested in two experimental rigs simulating intraoperative and weightbearing dynamic flexion. Baseline placement had all components in neutral position. Pearson correlation coefficients were calculated for absolute baseline kinematics and for relative kinematics due to changes in component position (i.e., the 10 altered positions vs. baseline). FINDINGS: Correlations between intraoperative and weightbearing rigs for absolute baseline kinematics were unpredictable, ranging from poor to excellent (mean 0.56 for tilt and mean 0.50 for shift). Correlations between rigs for changes in tilt and shift, i.e. relative kinematics, were strong (>0.8) or very strong (>0.9), with the exception of shift in early flexion (0.54). Differences in relative kinematics, which averaged 2.2 degrees in tilt (standard deviation 1.8 degrees ) and 1.6mm in shift (standard deviation 1.7mm), were notably smaller and less variable than differences in absolute kinematics, which averaged 4.2 degrees in tilt (standard deviation 3.6 degrees ) and 4.3mm in shift (standard deviation 3.9mm). INTERPRETATION: The results of this study suggest that, while absolute kinematics may differ between conditions, if a surgeon adjusts a component position to improve patellar kinematics intraoperatively, the effects of such a geometric change will likely carry through to the postoperative joint.


Assuntos
Artroplastia do Joelho , Patela/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Cirurgia Assistida por Computador , Suporte de Carga
9.
Orthop Traumatol Surg Res ; 104(3): 359-362, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29458201

RESUMO

Preoperative planning for the management of acetabular fracture is founded on geometric models allowing virtual repositioning of the bone fragments, but not taking account of soft tissue and the realities of the surgical procedure. The present technical note reports results using the first simulator to be based on a patient-specific biomechanical model, simulating the action of forces on the fragments and also the interactions between soft issue and bone: muscles, capsules, ligaments, and bone contacts. In all 14 cases, biomechanical simulation faithfully reproduced the intraoperative behavior of the various bone fragments and reduction quality. On Matta's criteria, anatomic reduction was achieved in 12 of the 14 patients (86%; 0.25mm±0.45 [range: 0-1]) and in the 12 corresponding simulations (86%; 0.42mm±0.51 [range: 0-1]). Mean semi-automatic segmentation time was 156min±37.9 [range: 120-180]. Mean simulation time was 23min±9 [range: 16-38]. The model needs larger-scale prospective validation, but offers a new tool suitable for teaching purposes and for assessment of surgical results in acetabular fracture. LEVEL OF EVIDENCE: IV: retrospective study.


Assuntos
Acetábulo/cirurgia , Fraturas Ósseas/cirurgia , Redução Aberta/métodos , Cirurgia Assistida por Computador/métodos , Acetábulo/lesões , Adulto , Fenômenos Biomecânicos , Simulação por Computador , Feminino , Fixação Interna de Fraturas , Humanos , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Estudos Retrospectivos , Adulto Jovem
10.
Proc Inst Mech Eng H ; 221(7): 813-20, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18019467

RESUMO

The variability in width, height, and spatial orientation of a spinal pedicle makes pedicle screw insertion a delicate operation. The aim of the current paper is to describe a computer-assisted surgical navigation system based on fluoroscopic X-ray image calibration and three-dimensional optical localizers in order to reduce radiation exposure while increasing accuracy and reliability of the surgical procedure for pedicle screw insertion. Instrumentation using transpedicular screw fixation was performed: in a first group, a conventional surgical procedure was carried out with 26 patients (138 screws); in a second group, a navigated surgical procedure (virtual fluoroscopy) was performed with 26 patients (140 screws). Evaluation of screw placement in every case was done by using plain X-rays and post-operative computer tomography scan. A 5 per cent cortex penetration (7 of 140 pedicle screws) occurred for the computer-assisted group. A 13 per cent penetration (18 of 138 pedicle screws) occurred for the non computer-assisted group. The radiation running time for each vertebra level (two screws) reached 3.5 s on average in the computer-assisted group and 11.5 s on average in the non computer-assisted group. The operative time for two screws on the same vertebra level reaches 10 min on average in the non computer-assisted group and 11.9 min on average in the computer-assisted group. The fluoroscopy-based (two-dimensional) navigation system for pedicle screw insertion is a safe and reliable procedure for surgery in the lower thoracic and lumbar spine.


Assuntos
Fluoroscopia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fusão Vertebral/métodos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Interface Usuário-Computador , Adolescente , Adulto , Idoso , Gráficos por Computador , Simulação por Computador , Feminino , Humanos , Laminectomia/instrumentação , Laminectomia/métodos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Robótica/métodos , Software , Fusão Vertebral/instrumentação , Resultado do Tratamento
11.
Orthop Traumatol Surg Res ; 103(5): 633-638, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28428032

RESUMO

BACKGROUND: The Letournel classification of acetabular fracture shows poor reproducibility in inexperienced observers, despite the introduction of 3D imaging. We therefore developed a method of semi-automatic segmentation based on CT data. The present prospective study aimed to assess: (1) whether semi-automatic bone-fragment segmentation increased the rate of correct classification; (2) if so, in which fracture types; and (3) feasibility using the open-source itksnap 3.0 software package without incurring extra cost for users. HYPOTHESIS: Semi-automatic segmentation of acetabular fractures significantly increases the rate of correct classification by orthopedic surgery residents. METHODS: Twelve orthopedic surgery residents classified 23 acetabular fractures. Six used conventional 3D reconstructions provided by the center's radiology department (conventional group) and 6 others used reconstructions obtained by semi-automatic segmentation using the open-source itksnap 3.0 software package (segmentation group). Bone fragments were identified by specific colors. Correct classification rates were compared between groups on Chi2 test. Assessment was repeated 2 weeks later, to determine intra-observer reproducibility. RESULTS: Correct classification rates were significantly higher in the "segmentation" group: 114/138 (83%) versus 71/138 (52%); P<0.0001. The difference was greater for simple (36/36 (100%) versus 17/36 (47%); P<0.0001) than complex fractures (79/102 (77%) versus 54/102 (53%); P=0.0004). Mean segmentation time per fracture was 27±3min [range, 21-35min]. The segmentation group showed excellent intra-observer correlation coefficients, overall (ICC=0.88), and for simple (ICC=0.92) and complex fractures (ICC=0.84). CONCLUSION: Semi-automatic segmentation, identifying the various bone fragments, was effective in increasing the rate of correct acetabular fracture classification on the Letournel system by orthopedic surgery residents. It may be considered for routine use in education and training. LEVEL OF EVIDENCE: III: prospective case-control study of a diagnostic procedure.


Assuntos
Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Fraturas Ósseas/classificação , Fraturas Ósseas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Internato e Residência , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Ortopedia/educação , Estudos Prospectivos , Reprodutibilidade dos Testes , Software/economia , Tomografia Computadorizada por Raios X
12.
Orthop Traumatol Surg Res ; 103(3): 335-339, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28235575

RESUMO

BACKGROUND: Epidemiological studies of acetabular fractures (AFs) are scarce and, to our knowledge, the most recent one from France, by Letournel and Judet, dates back to 1993. Studies have suggested a decrease in high-energy AFs contrasting with an increase in low-energy AFs due to the longer life expectancy. However, a French case-series study failed to confirm these data. We therefore conducted a 10-year retrospective study in a level-1 trauma centre to: (1) characterise the epidemiological profile of AF; (2) and to describe the treatment strategy. HYPOTHESIS: The epidemiological profile of AF in France is consonant with data from European case-series studies. METHOD: All patients managed for AF between 2005 and 2014 were included in this single-centre retrospective study. All patients were re-evaluated at our centre or another facility 6 months after the fracture. The epidemiological data were compared in the three treatment groups: non-operative, open reduction and internal fixation (ORIF), and total hip arthroplasty (THA). RESULTS: Between 2005 and 2014, 414 patients were admitted for AF. Mean age was 49.4 years (range: 15-101 years). Treatment was non-operative in 231 (56%) older patients, most of whom had low-energy fractures involving the anterior wall. THA with or without acetabular reinforcement and screw-plate fixation was performed in 27 (7%) older patients, most of whom had posterior-wall fractures and experienced postoperative complications (26/27 patients, 96%). ORIF was used in 156 (38%) younger patients, most of whom had high-energy fractures of greater complexity. CONCLUSION: Our results reflect the current indications in AF management. The epidemiological characteristics in our population are comparable to those reported in the few recent European epidemiological studies. To our knowledge, this is the largest French epidemiological study since the landmark work by Letournel and Judet. LEVEL OF EVIDENCE: Level IV, retrospective study.


Assuntos
Acetábulo/lesões , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/cirurgia , Acetábulo/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/estatística & dados numéricos , Placas Ósseas , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/estatística & dados numéricos , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Redução Aberta/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Centros de Traumatologia , Resultado do Tratamento , Adulto Jovem
13.
Orthop Traumatol Surg Res ; 103(4): 523-526, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28330796

RESUMO

PROBLEM AND HYPOTHESIS: Over time, some patients with unilateral or bilateral lumbosacral injuries experience chronic low back pain. We studied the sagittal and frontal balance in a population with these injuries to determine whether mismatch in the pelvic and lumbar angles are associated with chronic low back pain. PATIENTS AND METHODS: Patients with posterior pelvic ring fractures (Tile C1, C2, C3 and A3.3) that had healed were included. Foreign patients and those with an associated spinal or acetabular fracture or nonunion were excluded. The review consisted of subjective questionnaires, a clinical examination, and standing A/P and lateral stereoradiographic views. The pelvic tilt (PT), sacral slope (SS), pelvic incidence (PI), measured lumbar lordosis (LLm), T9 sagittal offset, leg discrepancy (LD) and lateral curvature (LC). The expected lumbar lordosis (LLe) was calculated using the formula LLe=PI+9°. We defined lumbopelvic mismatch (LPM) as the difference between LLm and LLe being equal or greater than 25% of LLe. RESULTS: Fifteen patients were reviewed after an average follow-up of 8.8 years [5.4-15]. There were four Tile C1, five Tile C2, five Tile C3 and one Tile A3.3 fracture. Ten of the 15 patients had low back pain. The mean angles were: LLm 49.6° and LLe 71.9° (P=0.002), PT 21.3°, SS 44.1°, PI 62.9° in patients with low back pain and LLm 57.4° and LLe 63.2° (P=0.55), PT 13°, SS 43.1°, PI 54.2° in those without. LPM was present in 9 patients, 8 of who had low back pain (P=0.02). Six patients, all of whom had low back pain, had a mean LC of 7.5° [4.5-23] (P=0.02). The mean LD was 0.77cm. DISCUSSION: The findings of this small study suggest that patients who experience low back pain after their posterior arch of the pelvic ring fracture has healed, have a lumbopelvic mismatch. Early treatment of these patients should aim to reestablish the anatomy of the pelvic base relative to the frontal and sagittal balance. LEVEL OF EVIDENCE: IV.


Assuntos
Dor Lombar/etiologia , Doenças da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/etiologia , Complicações Pós-Operatórias/etiologia , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fusão Vertebral/efeitos adversos , Adulto Jovem
14.
Injury ; 46(6): 1059-63, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25769199

RESUMO

PURPOSE: Global mortality of polytraumatised patients presenting pelvic ring fractures remains high (330%), despite improvements in treatment algorithms in Level I Trauma Centers. Many classifications have been developed in order to identify and analyse these pelvic ring lesions. However, it remains difficult to predict intra-pelvic haemorrhage. The aim of this study was to identify pelvic ring anatomical lesions associated with significant blood loss, susceptible to lead to life-threatening haemorrhage. MATERIAL AND METHOD: This study focused on a retrospective analysis of patients' medical files, all of whom were admitted to one of the shock rooms of Grenoble University Hospital, France, between January 2004 and December 2008. Treatment was given according to the institutional algorithm of the Alps Trauma Center and Emergency North Alpine Network Trauma System (TRENAU). Different hemodynamical parameters at arrival were measured, and the fractures were classified according to Young and Burgess, Tile, Letournel and Denis. One hundred and ninety seven patients were analysed. They were subdivided into two groups, embolised (Group E) and non-embolised (Group NE). RESULTS: Group NE included 171 patients with a mean age of 40.2 ± 8.7 years (15-90). Group E included 26 patients with a mean age of 41.6 ± 5.3 years (18-67). Twenty-six patients died during the initial treatment phase. Eleven belonged to Group E and 15 to Group NE. Mortality was significantly higher in Group E (42.3% vs 8.8% in Group NE) (p < 0.05). There were significantly many more Tile C unstable fractures in Group E (p = 0.0014), and anterior lesions, according to Letournel, with pubic symphysis disruption were significantly more likely to lead to active bleeding treated by selective embolisation (p = 0.0014). Posterior pelvic ring lesions with iliac wing fracture and transforaminal sacral fractures (Denis 2) were also more frequently associated with bleeding treated by embolisation (p = 0.0088 and p = 0.0369 respectively). DISCUSSION/CONCLUSION: It appears that in our series the primary identification and classification of osteo-ligamentous lesions (according to Letournel and Denis' classifications) allows to anticipate the importance of bleeding and to adapt the management of patients accordingly, in order to quickly organise angiography with embolisation.


Assuntos
Angiografia , Embolização Terapêutica/métodos , Fraturas Ósseas/patologia , Hemorragia/patologia , Pelve/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angiografia/métodos , Feminino , Fraturas Ósseas/complicações , Fraturas Ósseas/terapia , França/epidemiologia , Hemorragia/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/lesões , Ossos Pélvicos/patologia , Garantia da Qualidade dos Cuidados de Saúde , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Índices de Gravidade do Trauma
15.
Comput Aided Surg ; 3(6): 297-305, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-10379979

RESUMO

The aim of this study was to improve the reliability of pedicle screw insertion. Transpedicle screw insertion may cause neurological, vascular, and mechanical complications. Previous studies of surgical procedures have shown a significant rate of incorrect placement of the screw ranging from 10 to 40%. A new technique that combines preoperative computed tomography (CT) imaging with intraoperative passive navigation was used to perform 64 pedicle screw insertions in the thoracolumbar region. At the same time, 64 pedicle screw insertions were performed manually in the same region and on the same vertebral levels. Surgery was followed in all cases by postoperative radiographs and computed tomography examination, which allowed measurements of screw position relative to pedicle position to be performed. A comparison between the two groups showed that six screws in 64 vertebra (9%) had incorrect placement with the computer-assisted technique whereas 28 screws in 64 vertebra (44%) had incorrect placement with manual insertion. The intraoperative accuracy provided by the computer after registration was better than 1 mm. The good results obtained are similar to those reported in the literature. The cortex penetration observed with the computer-assisted technique was not imputed to computer failure. Errors by the surgeon in acquiring data in the pre- and perioperative steps may explain the six incorrect screw placements. This clinical experience confirms that the accuracy and the reliability of this computer-assisted technique are good.


Assuntos
Parafusos Ósseos , Coluna Vertebral/cirurgia , Terapia Assistida por Computador/métodos , Humanos , Cuidados Pré-Operatórios , Pseudoartrose/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Espondilolistese/cirurgia , Tomografia Computadorizada por Raios X
16.
Comput Aided Surg ; 6(4): 204-11, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11835615

RESUMO

This study presents early results of clinical experience with the application of Computer Assisted Surgery (CAS) to percutaneous iliosacral screwing, with comparison to a historical series of patients treated using percutaneous fluoroscopy. Four patients were instrumented using a CAS system, with 10 screws being inserted. Thirty patients were treated by percutaneous fluoroscopic screwing, with 51 screws being inserted. The follow-up assessment included the following criteria; operative time, parameters of radiation exposure, neurological examination, screw placement evaluation on CT-scan, antalgic drug consumption, pain, Majeed grading, and loosening of implants. In the CAS group, the average radiation time was 0.35 min per patient and 0.14 min per screw. No trajectories outside the bone and no postoperative neurological deficits were found. In the fluoroscopic group, the average radiation time was 1.03 min per patient and 0.6 min per screw. Twelve screws had outside-bone trajectories, and iatrogenic neurological deficits were found in seven patients. The average operative time was 50 min in the CAS group and 35 min in the fluoroscopic group. The present CAS technique shows better placement of iliosacral screws, with no outside-bone trajectories and lower radiation exposure.


Assuntos
Parafusos Ósseos , Ossos Pélvicos/cirurgia , Cirurgia Assistida por Computador , Ultrassonografia , Adulto , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/diagnóstico por imagem , Fatores de Tempo
17.
J Telemed Telecare ; 4 Suppl 1: 85-7, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9640749

RESUMO

Fifteen elderly patients participated in a teleconsultation with an orthopaedic surgeon, which was then followed by a conventional, face-to-face consultation. The comparison between the surgeon's ratings for both types of consultation suggested that the telemedicine consultation was satisfactory in terms of the quality of image and sound, the clinical examination and general simplicity. The telemedicine consultations did not generate a need for any additional clinical investigations, although in two cases a face-to-face consultation was necessary to clarify clinical signs (shortening of a limb and scar tissue). The surgeon's rating of his decision level was superior in the face-to-face situation in four cases, and for 11 patients it was equal. Similarly, the surgeon's level of confidence in decision making was superior in the conventional situation for five patients and equal for 10 patients. Patient attitudes towards teleconsulting were favourable. There was a high level of patient satisfaction. Teleconsulting between orthopaedic surgeons and elderly patients therefore appears to be possible, provided that certain technical, clinical and psychological considerations are addressed.


Assuntos
Serviços de Saúde para Idosos , Ortopedia/métodos , Centros de Reabilitação , Consulta Remota , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , França , Humanos , Masculino
18.
Stud Health Technol Inform ; 81: 515-20, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11317800

RESUMO

This study presents early results of the clinical experience of computer assisted surgery (CAS) applied to percutaneous iliosacral screwing. The results of these 10 first cases (4 patients) are compared to an historical series of 51 cases (30 patients). The CAS technique shows better screw placement without outside bone screw and a very low radiation exposure.


Assuntos
Parafusos Ósseos , Fluoroscopia , Ílio/cirurgia , Sacro/cirurgia , Tomografia Computadorizada por Raios X , Ultrassonografia , Interface Usuário-Computador , Adolescente , Adulto , Idoso , Artrodese , Feminino , Humanos , Ílio/lesões , Ílio/patologia , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Sacro/lesões , Sacro/patologia
19.
Rev Chir Orthop Reparatrice Appar Mot ; 86(4): 360-9, 2000 Jun.
Artigo em Francês | MEDLINE | ID: mdl-10880935

RESUMO

PURPOSE OF THE STUDY: Percutaneous iliosacral screws are used advantageously to fix unstable pelvic girdle avoiding the morbidity of open access for conventional screw fixation. The insertion technique must be precise due to the risk of injury to the lumbosacral nerve trunk, the cauda equina roots, and the first sacral nerve. We undertook a study of the implantation site of iliosacral screws looking for a means of standardizing the drilling procedure on the basis of 3D computed tomography (CT) data. MATERIAL AND METHODS: A CT series with 3D reconstruction was performed on 11 pelvis bones. We retained pelvis parameters and characterized the axis and narrow zone of the sacral wing. The insertion routes of 6.5 mm cancelous bone screws were simulated: two iliosacral routes fixing S1, and two iliosacroiliac routes fixing S1 and S2. The values of the pelvic parameters and the positions of the screws were compared with the Spearman correlation test and graphic regression. RESULTS: The pelvic incidence was a mean 47 degrees. The length of the sacral wing was a mean 73 mm. The narrow zone of the wing was 47 mm from the lateral iliac fossa. In the narrow zone, the wing section showed an oval shape: 22 mm largest diameter, 11 mm smallest diameter. The wing was oriented 84 degrees in the paracoronal plane perpendicular to the plane of the sacral plate, 67 degrees in the para-axial plane parallel to the sacral plate, and 37 degrees in the sagittal plane of the subject. The length of the upper S1 screw was a mean 80 mm. This upper screw was inclined 89 degrees in the para-coronal plant, 61 degrees in the para-axial plane and 28 degrees in the sagittal plane. The length of the lower S1 screw as a mean 80 mm. This lower screw was inclined 74 degrees in the para-coronal plane, 91 degrees in the para-axial plane and 110 degrees in the sagittal plane. The fixation screws could be inserted in 12 out of 22 cases. Correlations were found with height of the subject, length of the wing and the screw, and screw inclination. The inclination of the upper S1 screw in the para-coronal plane was correlated with the larger diameter of the sacral wing. DISCUSSION: The pelvis parameters measured were comparable with data in the literature. The very small dimensions of the narrow zone dictate a very precise drilling for the narrow zone. This narrow zone determines the inclination of the screw insertion. In the sagittal plane the standard deviation was very large making it impossible to interpret the data. The route of the upper screw runs obliquely forward in the plane parallel to the sacral plate. The lower screw runs upwardly in the plane perpendicular to the sacral plate. It does not appear possible to insert fixation screws in a routine procedure. Preoperative assessment would be necessary before percutaneous insertion. CONCLUSION: The 3D CT reconstructions of the sacral wing can be used to determine the precise optimal position of the two iliosacral screws. The principle orientations can be deducted from the plane of the sacral plate. Approximate indications can help reduce operative time and exposure to irradiation (patient and surgeon). Percutaneous iliosacroiliac screw fixation cannot be proposed for all patients.


Assuntos
Parafusos Ósseos , Simulação por Computador , Fixação Interna de Fraturas/métodos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Implantação Dentária Endóssea/métodos , Feminino , Fixação Interna de Fraturas/instrumentação , Fraturas Espontâneas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Ossos Pélvicos/anatomia & histologia , Ossos Pélvicos/lesões , Pelvimetria , Valores de Referência , Análise de Regressão , Sacro/anatomia & histologia , Sacro/diagnóstico por imagem , Sacro/cirurgia , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X
20.
Rev Chir Orthop Reparatrice Appar Mot ; 90(2): 122-31, 2004 Apr.
Artigo em Francês | MEDLINE | ID: mdl-15107699

RESUMO

PURPOSE OF THE STUDY: The purpose of this study was to analyze lesions to the lumbosacral plexus related to pelvic injury and its treatment. MATERIAL AND METHODS: Forty-four patients presented 50 posterior osteoligamentary lesions of the pelvic girdle. All patients except eight had other injuries. Mean ISS was 27/75. Posterior lesions were: iliosacral disjunction (n=23), extra-foraminal fracture of the sacrum (n=4), transforaminal fracture (n=22), intra-foraminal fracture (n=1). Vertical posterior displacement was > 1 cm for 24 posterior lesions. Orthopedic reduction was performed at admission for all patients. Fluoroscopy-guided percutaneous lag screw fixation was performed in all cases, on the average eight days after the accident. Neurological involvement was evaluated at admission, after surgery, and at last follow-up. Data were recorded for skeletal muscles, lower limb dermatomes, tendon reflexes, and anal tone. Screw emplacement was checked on the CT-scan. Outcome was assessed subjectively with the Majeed score, a self-administered visual analog scale, and use of antalgesic drugs according to the WHO classification. RESULTS: The neurological examination could not be performed for ten patients at admission. Postoperatively, there was a neurological deficit associated with 26 osteoligamentary lesions (23 lesions of the lumbosacral trunk, 14 lesions of the S1 spinal nerve, 3 lesions of the pudendal nerve, 12 lesions of the superior gluteal nerve, and 10 lesions of the femoral nerve). Patients with neurological involvement had experienced more severe trauma. The iliosacral screw was partially extra-osseous in thirteen cases, with an associated iatrogenic neurological deficit in seven. At mean follow-up of 20 Months (range 4-50) there persisted ten major sequelae including eight cases of hallux extensor deficit. DISCUSSION: Neurological involvement is underestimated during the acute phase of trauma. After recovery, only the manifestations of major injuries persist. The prognosis is poor in the event of a stretched lumbosacral trunk or gluteal nerve due to iliosacral disjunction. Prognosis is good for nerve contusion due to sacral fracture because of early reduction. The femoral nerve is generally injured by compression due to a peri-fracture hematoma; recovery is the rule. Iliosacral screwing requires rigorous technique by a skilled and experienced surgeon. CONCLUSION: About 52% of posterior osteoligamentary injuries are associated with neurological symptoms. After recovery, permanent deficit persists in 21.7%. The most common sequelae are hallux extensor and gluteus medius palsy due to stretching of the lumbosacral trunk.


Assuntos
Parafusos Ósseos , Fraturas Fechadas/cirurgia , Plexo Lombossacral/lesões , Procedimentos Ortopédicos/métodos , Pelve/lesões , Adolescente , Adulto , Idoso , Feminino , Humanos , Doença Iatrogênica , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA