Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Euro Surveill ; 27(4)2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35086612

RESUMO

IntroductionImmunoassays targeting different SARS-CoV-2-specific antibodies are employed for seroprevalence studies. The degree of variability between immunoassays targeting anti-nucleocapsid (anti-NP; the majority) vs the potentially neutralising anti-spike antibodies (including anti-receptor-binding domain; anti-RBD), particularly in mild or asymptomatic disease, remains unclear.AimsWe aimed to explore variability in anti-NP and anti-RBD antibody detectability following mild symptomatic or asymptomatic SARS-CoV-2 infection and analyse antibody response for correlation with symptomatology.MethodsA multicentre prospective cross-sectional study was undertaken (April-July 2020). Paired serum samples were tested for anti-NP and anti-RBD IgG antibodies and reactivity expressed as binding ratios (BR). Multivariate linear regression was performed analysing age, sex, time since onset, symptomatology, anti-NP and anti-RBD antibody BR.ResultsWe included 906 adults. Antibody results (793/906; 87.5%; 95% confidence interval: 85.2-89.6) and BR strongly correlated (ρ = 0.75). PCR-confirmed cases were more frequently identified by anti-RBD (129/130) than anti-NP (123/130). Anti-RBD testing identified 83 of 325 (25.5%) cases otherwise reported as negative for anti-NP. Anti-NP presence (+1.75/unit increase; p < 0.001), fever (≥ 38°C; +1.81; p < 0.001) or anosmia (+1.91; p < 0.001) were significantly associated with increased anti-RBD BR. Age (p = 0.85), sex (p = 0.28) and cough (p = 0.35) were not. When time since symptom onset was considered, we did not observe a significant change in anti-RBD BR (p = 0.95) but did note decreasing anti-NP BR (p < 0.001).ConclusionSARS-CoV-2 anti-RBD IgG showed significant correlation with anti-NP IgG for absolute seroconversion and BR. Higher BR were seen in symptomatic individuals, particularly those with fever. Inter-assay variability (12.5%) was evident and raises considerations for optimising seroprevalence testing strategies/studies.


Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Anticorpos Antivirais , Formação de Anticorpos , Estudos Transversais , Humanos , Imunoglobulina G , Londres , Estudos Prospectivos , Estudos Soroepidemiológicos , Glicoproteína da Espícula de Coronavírus
2.
Clin Infect Dis ; 72(12): 2103-2111, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-32246143

RESUMO

BACKGROUND: A locally developed case-based reasoning (CBR) algorithm, designed to augment antimicrobial prescribing in secondary care was evaluated. METHODS: Prescribing recommendations made by a CBR algorithm were compared to decisions made by physicians in clinical practice. Comparisons were examined in 2 patient populations: first, in patients with confirmed Escherichia coli blood stream infections ("E. coli patients"), and second in ward-based patients presenting with a range of potential infections ("ward patients"). Prescribing recommendations were compared against the Antimicrobial Spectrum Index (ASI) and the World Health Organization Essential Medicine List Access, Watch, Reserve (AWaRe) classification system. Appropriateness of a prescription was defined as the spectrum of the prescription covering the known or most-likely organism antimicrobial sensitivity profile. RESULTS: In total, 224 patients (145 E. coli patients and 79 ward patients) were included. Mean (standard deviation) age was 66 (18) years with 108/224 (48%) female sex. The CBR recommendations were appropriate in 202/224 (90%) compared to 186/224 (83%) in practice (odds ratio [OR]: 1.24 95% confidence interval [CI]: .392-3.936; P = .71). CBR recommendations had a smaller ASI compared to practice with a median (range) of 6 (0-13) compared to 8 (0-12) (P < .01). CBR recommendations were more likely to be classified as Access class antimicrobials compared to physicians' prescriptions at 110/224 (49%) vs. 79/224 (35%) (OR: 1.77; 95% CI: 1.212-2.588; P < .01). Results were similar for E. coli and ward patients on subgroup analysis. CONCLUSIONS: A CBR-driven decision support system provided appropriate recommendations within a narrower spectrum compared to current clinical practice. Future work must investigate the impact of this intervention on prescribing behaviors more broadly and patient outcomes.


Assuntos
Anti-Infecciosos , Gestão de Antimicrobianos , Idoso , Algoritmos , Antibacterianos/uso terapêutico , Anti-Infecciosos/uso terapêutico , Escherichia coli , Feminino , Humanos , Prescrição Inadequada , Padrões de Prática Médica
3.
BMC Infect Dis ; 21(1): 665, 2021 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-34238234

RESUMO

BACKGROUND: As SARS-CoV-2 testing expands, particularly to widespread asymptomatic testing, high sensitivity point-of-care PCR platforms may optimise potential benefits from pooling multiple patients' samples. METHOD: We tested patients and asymptomatic citizens for SARS-CoV-2, exploring the efficiency and utility of CovidNudge (i) for detection in individuals' sputum (compared to nasopharyngeal swabs), (ii) for detection in pooled sputum samples, and (iii) by modelling roll out scenarios for pooled sputum testing. RESULTS: Across 295 paired samples, we find no difference (p = 0.1236) in signal strength for sputum (mean amplified replicates (MAR) 25.2, standard deviation (SD) 14.2, range 0-60) compared to nasopharyngeal swabs (MAR 27.8, SD 12.4, range 6-56). At 10-sample pool size we find some drop in absolute strength of signal (individual sputum MAR 42.1, SD 11.8, range 13-60 vs. pooled sputum MAR 25.3, SD 14.6, range 1-54; p < 0.0001), but only marginal drop in sensitivity (51/53,96%). We determine a limit of detection of 250 copies/ml for an individual test, rising only four-fold to 1000copies/ml for a 10-sample pool. We find optimal pooled testing efficiency to be a 12-3-1-sample model, yet as prevalence increases, pool size should decrease; at 5% prevalence to maintain a 75% probability of negative first test, 5-sample pools are optimal. CONCLUSION: We describe for the first time the use of sequentially dipped sputum samples for rapid pooled point of care SARS-CoV-2 PCR testing. The potential to screen asymptomatic cohorts rapidly, at the point-of-care, with PCR, offers the potential to quickly identify and isolate positive individuals within a population "bubble".


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virologia , Testes Imediatos , SARS-CoV-2/isolamento & purificação , Escarro/virologia , Testes Diagnósticos de Rotina , Humanos , Limite de Detecção , Nasofaringe/virologia , Sensibilidade e Especificidade , Carga Viral
4.
BMC Med Inform Decis Mak ; 17(1): 168, 2017 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-29216923

RESUMO

BACKGROUND: Antimicrobial Resistance is threatening our ability to treat common infectious diseases and overuse of antimicrobials to treat human infections in hospitals is accelerating this process. Clinical Decision Support Systems (CDSSs) have been proven to enhance quality of care by promoting change in prescription practices through antimicrobial selection advice. However, bypassing an initial assessment to determine the existence of an underlying disease that justifies the need of antimicrobial therapy might lead to indiscriminate and often unnecessary prescriptions. METHODS: From pathology laboratory tests, six biochemical markers were selected and combined with microbiology outcomes from susceptibility tests to create a unique dataset with over one and a half million daily profiles to perform infection risk inference. Outliers were discarded using the inter-quartile range rule and several sampling techniques were studied to tackle the class imbalance problem. The first phase selects the most effective and robust model during training using ten-fold stratified cross-validation. The second phase evaluates the final model after isotonic calibration in scenarios with missing inputs and imbalanced class distributions. RESULTS: More than 50% of infected profiles have daily requested laboratory tests for the six biochemical markers with very promising infection inference results: area under the receiver operating characteristic curve (0.80-0.83), sensitivity (0.64-0.75) and specificity (0.92-0.97). Standardization consistently outperforms normalization and sensitivity is enhanced by using the SMOTE sampling technique. Furthermore, models operated without noticeable loss in performance if at least four biomarkers were available. CONCLUSION: The selected biomarkers comprise enough information to perform infection risk inference with a high degree of confidence even in the presence of incomplete and imbalanced data. Since they are commonly available in hospitals, Clinical Decision Support Systems could benefit from these findings to assist clinicians in deciding whether or not to initiate antimicrobial therapy to improve prescription practices.


Assuntos
Anti-Infecciosos , Biomarcadores , Sistemas de Apoio a Decisões Clínicas , Resistência Microbiana a Medicamentos , Medição de Risco/métodos , Máquina de Vetores de Suporte , Sistemas de Apoio a Decisões Clínicas/estatística & dados numéricos , Humanos , Medição de Risco/estatística & dados numéricos
5.
Nat Methods ; 10(7): 641-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23749303

RESUMO

We developed an integrated chip for real-time amplification and detection of nucleic acid using pH-sensing complementary metal-oxide semiconductor (CMOS) technology. Here we show an amplification-coupled detection method for directly measuring released hydrogen ions during nucleotide incorporation rather than relying on indirect measurements such as fluorescent dyes. This is a label-free, non-optical, real-time method for detecting and quantifying target sequences by monitoring pH signatures of native amplification chemistries. The chip has ion-sensitive field effect transistor (ISFET) sensors, temperature sensors, resistive heating, signal processing and control circuitry all integrated to create a full system-on-chip platform. We evaluated the platform using two amplification strategies: PCR and isothermal amplification. Using this platform, we genotyped and discriminated unique single-nucleotide polymorphism (SNP) variants of the cytochrome P450 family from crude human saliva. We anticipate this semiconductor technology will enable the creation of devices for cost-effective, portable and scalable real-time nucleic acid analysis.


Assuntos
Concentração de Íons de Hidrogênio , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Semicondutores , Análise de Sequência de DNA/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Integração de Sistemas
6.
Analyst ; 141(15): 4659-4666, 2016 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-27243147

RESUMO

This work describes the preparation of an array of individually addressable pH sensitive microneedles which are sensitized by electrodepositing iridium oxide. The impact of the deposition potential, storage conditions and interferents on the sensor characteristics such as slope, offset, intra- and inter-batch reproducibility is investigated. The device may be a useful tool for carrying out direct pH measurements of soft and heterogeneous samples such as tissues and organs. For example, we demonstrated that the microneedle array can be employed for real-time mapping of the cardiac pH distribution during cycles of global ischemia and reperfusion.

7.
Sensors (Basel) ; 14(7): 11629-39, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24988379

RESUMO

Emerging materials in the field of implantable sensors should meet the needs for biocompatibility; transparency; flexibility and integrability. In this work; we present an integrated approach for implementing flexible bio-sensors based on thin Parylene C films that serve both as flexible support substrates and as active H(+) sensing membranes within the same platform. Using standard micro-fabrication techniques; a miniaturized 40-electrode array was implemented on a 5 µm-thick Parylene C film. A thin capping film (1 µm) of Parylene on top of the array was plasma oxidized and served as the pH sensing membrane. The sensor was evaluated with the use of extended gate discrete MOSFETs to separate the chemistry from the electronics and prolong the lifetime of the sensor. The chemical sensing array spatially maps the local pH levels; providing a reliable and rapid-response (<5 s) system with a sensitivity of 23 mV/pH. Moreover; it preserves excellent encapsulation integrity and low chemical drifts (0.26-0.38 mV/min). The proposed approach is able to deliver hybrid flexible sensing platforms that will facilitate concurrent electrical and chemical recordings; with application in real-time physiological recordings of organs and tissues.


Assuntos
Eletrodos Implantados , Concentração de Íons de Hidrogênio , Eletrodos Seletivos de Íons , Análise em Microsséries/instrumentação , Polímeros/química , Transistores Eletrônicos , Xilenos/química , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento
8.
Sci Rep ; 14(1): 5428, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443427

RESUMO

Dietary interventions can reduce progression to type 2 diabetes mellitus (T2DM) in people with non-diabetic hyperglycaemia. In this study we aimed to determine the impact of a DNA-personalised nutrition intervention in people with non-diabetic hyperglycaemia over 26 weeks. ASPIRE-DNA was a pilot study. Participants were randomised into three arms to receive either (i) Control arm: standard care (NICE guidelines) (n = 51), (ii) Intervention arm: DNA-personalised dietary advice (n = 50), or (iii) Exploratory arm: DNA-personalised dietary advice via a self-guided app and wearable device (n = 46). The primary outcome was the difference in fasting plasma glucose (FPG) between the Control and Intervention arms after 6 weeks. 180 people were recruited, of whom 148 people were randomised, mean age of 59 years (SD = 11), 69% of whom were female. There was no significant difference in the FPG change between the Control and Intervention arms at 6 weeks (- 0.13 mmol/L (95% CI [- 0.37, 0.11]), p = 0.29), however, we found that a DNA-personalised dietary intervention led to a significant reduction of FPG at 26 weeks in the Intervention arm when compared to standard care (- 0.019 (SD = 0.008), p = 0.01), as did the Exploratory arm (- 0.021 (SD = 0.008), p = 0.006). HbA1c at 26 weeks was significantly reduced in the Intervention arm when compared to standard care (- 0.038 (SD = 0.018), p = 0.04). There was some evidence suggesting prevention of progression to T2DM across the groups that received a DNA-based intervention (p = 0.06). Personalisation of dietary advice based on DNA did not result in glucose changes within the first 6 weeks but was associated with significant reduction of FPG and HbA1c at 26 weeks when compared to standard care. The DNA-based diet was effective regardless of intervention type, though results should be interpreted with caution due to the low sample size. These findings suggest that DNA-based dietary guidance is an effective intervention compared to standard care, but there is still a minimum timeframe of adherence to the intervention before changes in clinical outcomes become apparent.Trial Registration: www.clinicaltrials.gov.uk Ref: NCT03702465.


Assuntos
Diabetes Mellitus Tipo 2 , Hiperglicemia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 2/prevenção & controle , DNA , Glucose , Hemoglobinas Glicadas , Projetos Piloto , Idoso
9.
J Comput Neurosci ; 34(3): 477-88, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23179855

RESUMO

Optogenetics offers an unprecedented ability to spatially target neuronal stimulations. This study investigated via simulation, for the first time, how the spatial pattern of excitation affects the response of channelrhodopsin-2 (ChR2) expressing neurons. First we described a methodology for modeling ChR2 in the NEURON simulation platform. Then, we compared four most commonly considered illumination strategies (somatic, dendritic, axonal and whole cell) in a paradigmatic model of a cortical layer V pyramidal cell. We show that the spatial pattern of illumination has an important impact on the efficiency of stimulation and the kinetics of the spiking output. Whole cell illumination synchronizes the depolarization of the dendritic tree and the soma and evokes spiking characteristics with a distinct pattern including an increased bursting rate and enhanced back propagation of action potentials (bAPs). This type of illumination is the most efficient as a given irradiance threshold was achievable with only 6 % of ChR2 density needed in the case of somatic illumination. Targeting only the axon initial segment requires a high ChR2 density to achieve a given threshold irradiance and a prolonged illumination does not yield sustained spiking. We also show that patterned illumination can be used to modulate the bAPs and hence spatially modulate the direction and amplitude of spike time dependent plasticity protocols. We further found the irradiance threshold to increase in proportion to the demyelination level of an axon, suggesting that measurements of the irradiance threshold (for example relative to the soma) could be used to remotely probe a loss of neural myelin sheath, which is a hallmark of several neurodegenerative diseases.


Assuntos
Potenciais de Ação/fisiologia , Retroalimentação Fisiológica/fisiologia , Luz , Modelos Neurológicos , Neurônios/fisiologia , Optogenética , Potenciais de Ação/efeitos da radiação , Animais , Cálcio/metabolismo , Channelrhodopsins , Neurônios/efeitos da radiação , Tempo de Reação/fisiologia
10.
Biomed Microdevices ; 15(5): 737-49, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23559403

RESUMO

In this paper, the development of a fully implantable wireless sensor able to provide continuous real-time accurate pressure measurements is presented. Surface Acoustic Wave (SAW) technology was used to deposit resonators on crystalline quartz wafers; the wafers were then assembled to produce a pressure sensitive device. Excitation and reading via a miniature antenna attached to the pressure sensor enables continuous external interrogation. The main advantages of such a configuration are the long term stability of quartz and the low power necessary for the interrogation, which allows 24/7 interrogation by means of a hand-held, battery powered device. Such data are of vital importance to clinicians monitoring and treating the effects of hypertension and heart failure. A prototype was designed and tested using both a bio-phantom test rig and an animal model. The pressure traces for both compare very well with a commercially available catheter tip pressure transducer. The work presented in this paper is the first known wireless pressure data from the left ventricle of the heart of a living swine.


Assuntos
Determinação da Pressão Arterial/instrumentação , Determinação da Pressão Arterial/métodos , Próteses e Implantes , Tecnologia sem Fio , Animais , Pressão Sanguínea , Desenho de Equipamento , Modelos Animais , Suínos , Transdutores de Pressão
11.
PLOS Digit Health ; 2(8): e0000333, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37647301

RESUMO

Mobile health applications, which employ wireless technology for healthcare, can aid behaviour change and subsequently improve health outcomes. Mobile health applications have been developed to increase physical activity, but are rarely grounded on behavioural theory and employ simple techniques for personalisation, which has been proven effective in promoting behaviour change. In this work, we propose a theoretically driven and personalised behavioural intervention delivered through an adaptive knowledge-based system. The behavioural system design is guided by the Behavioural Change Wheel and the Capability-Opportunity-Motivation behavioural model. The system exploits the ever-increasing availability of health data from wearable devices, point-of-care tests and consumer genetic tests to issue highly personalised physical activity and sedentary behaviour recommendations. To provide the personalised recommendations, the system firstly classifies the user into one of four diabetes clusters based on their cardiometabolic profile. Secondly, it recommends activity levels based on their genotype and past activity history, and finally, it presents the user with their current risk of developing cardiovascular disease. In addition, leptin, a hormone involved in metabolism, is included as a feedback biosignal to personalise the recommendations further. As a case study, we designed and demonstrated the system on people with type 2 diabetes, since it is a chronic condition often managed through lifestyle changes, such as physical activity increase and sedentary behaviour reduction. We trained and simulated the system using data from diabetic participants of the UK Biobank, a large-scale clinical database, and demonstrate that the system could help increase activity over time. These results warrant a real-life implementation of the system, which we aim to evaluate through human intervention.

12.
Cancers (Basel) ; 15(22)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38001698

RESUMO

Cancer remains a leading cause of death worldwide, despite many advances in diagnosis and treatment. Precision medicine has been a key area of focus, with research providing insights and progress in helping to lower cancer mortality through better patient stratification for therapies and more precise diagnostic techniques. However, unequal access to cancer care is still a global concern, with many patients having limited access to diagnostic tests and treatment regimens. Noninvasive liquid biopsy (LB) technology can determine tumour-specific molecular alterations in peripheral samples. This allows clinicians to infer knowledge at a DNA or cellular level, which can be used to screen individuals with high cancer risk, personalize treatments, monitor treatment response, and detect metastasis early. As scientific understanding of cancer pathology increases, LB technologies that utilize circulating tumour DNA (ctDNA) and circulating tumour cells (CTCs) have evolved over the course of research. These technologies incorporate tumour-specific markers into molecular testing platforms. For clinical translation and maximum patient benefit at a wider scale, the accuracy, accessibility, and affordability of LB tests need to be prioritized and compared with gold standard methodologies in current use. In this review, we highlight the range of technologies in LB diagnostics and discuss the future prospects of LB through the anticipated evolution of current technologies and the integration of emerging and novel ones. This could potentially allow a more cost-effective model of cancer care to be widely adopted.

13.
PLoS One ; 17(5): e0268289, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35544519

RESUMO

The negative effect of sedentary behaviour on type 2 diabetes markers is established, but the interaction with measures of physical activity is still largely unknown. Previous studies have analysed associations with single-activity models, which ignore the interaction with other behaviours. By including results from various analytical approaches, this review critically summarises the effects of sedentary behaviour on diabetes markers and the benefits of substitutions and compositions of physical activity. Ovid Medline, Embase and Cochrane Library databases were systematically searched. Studies were selected if sedentary behaviour and physical activity were measured by accelerometer in the general population, and if associations were reported with glucose, insulin, HOMA-IR, insulin sensitivity, HbA1c, diabetes incidence, CRP and IL-6. Forty-five studies were included in the review. Conclusive detrimental associations with sedentary behaviour were determined for 2-h insulin (6/12 studies found associations), fasting insulin (15/19 studies), insulin sensitivity (4/6 studies), diabetes (3/4 studies) and IL-6 (2/3 studies). Reallocating sedentary behaviour to light or moderate-to-vigorous activity has a beneficial effect for 2-h glucose (1/1 studies), fasting insulin (3/3 studies), HOMA-IR (1/1 studies) and insulin sensitivity (1/1 studies). Compositional measures of sedentary behaviour were found to affect 2-h glucose (1/1 studies), fasting insulin (2/3 studies), 2-h insulin (1/1 studies), HOMA-IR (2/2 studies) and CRP (1/1 studies). Different analytical methods produced conflicting results for fasting glucose, 2-h glucose, 2-h insulin, insulin sensitivity, HOMA-IR, diabetes, hbA1c, CRP and IL-6. Studies analysing data by quartiles report independent associations between sedentary behaviour and fasting insulin, HOMA-IR and diabetes only for high duration of sedentary time (7-9 hours/day). However, this review could not provide sufficient evidence for a time-specific cut-off of sedentary behaviour for diabetes biomarkers. While substituting sedentary behaviour with moderate-to-vigorous activity brings greater improvements for health, light activity also benefits metabolic health. Future research should elucidate the effects of substituting and combining different activity durations and modalities.


Assuntos
Diabetes Mellitus Tipo 2 , Resistência à Insulina , Biomarcadores , Glicemia/metabolismo , Exercício Físico , Glucose/metabolismo , Hemoglobinas Glicadas , Humanos , Insulina/metabolismo , Interleucina-6 , Comportamento Sedentário
14.
Biosensors (Basel) ; 12(7)2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35884340

RESUMO

This paper presents a fully automated point-of-care device for protein quantification using short-DNA aptamers, where no manual sample preparation is needed. The device is based on our novel aptamer-based methodology combined with real-time polymerase chain reaction (qPCR), which we employ for very sensitive protein quantification. DNA amplification through qPCR, sensing and real-time data processing are seamlessly integrated into a point-of-care device equipped with a disposable cartridge for automated sample preparation. The system's modular nature allows for easy assembly, adjustment and expansion towards a variety of biomarkers for applications in disease diagnostics and personalised medicine. Alongside the device description, we also present a new algorithm, which we named PeakFluo, to perform automated and real-time quantification of proteins. PeakFluo achieves better linearity than proprietary software from a commercially available qPCR machine, and it allows for early detection of the amplification signal. Additionally, we propose an alternative way to use the proposed device beyond the quantitative reading, which can provide clinically relevant advice. We demonstrate how a convolutional neural network algorithm trained on qPCR images can classify samples into high/low concentration classes. This method can help classify obese patients from their leptin values to optimise weight loss therapies in clinical settings.


Assuntos
Aptâmeros de Nucleotídeos , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Software
15.
ACS Sens ; 6(3): 709-715, 2021 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-33650854

RESUMO

Protein quantification is traditionally performed through enzyme-linked immunosorbent assay (ELISA), which involves long preparation times. To overcome this, new approaches use aptamers as an alternative to antibodies. In this paper, we present a new approach to quantify proteins with short DNA aptamers through polymerase chain reaction (PCR) resulting in shorter protocol times with comparatively improved limits of detection. The proposed method includes a novel way to quantify both the target protein and the corresponding short DNA-aptamers simultaneously, which also allows us to fully characterize the performance of aptasensors. Human leptin is used as a target protein to validate this technique, because it is considered an important biomarker for obesity-related studies. In our experiments, we achieved the lowest limit of detection of 100 pg/mL within less than 2 h, a limit affected by the dissociation constant of the leptin aptamer, which could be improved by selecting a more specific aptamer. Because of the simple and inexpensive approach, this technique can be employed for Lab-On-Chip implementations and for rapid "on-site" quantification of proteins.


Assuntos
Aptâmeros de Nucleotídeos , DNA/genética , Ensaio de Imunoadsorção Enzimática , Humanos , Leptina/genética , Reação em Cadeia da Polimerase
16.
IEEE J Biomed Health Inform ; 24(11): 3276-3284, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32149660

RESUMO

Intensive attention on personalised skin-health solutions is on account of incomparable love of skin and an urgent need for effective treatment. In the meanwhile, people have great expectations on how to utilise genetic knowledge of our body to provide a precise solution for different individuals, such as daily use of skin-health products, since the rapid development of genetic test services and skin-health science. However, the complexity of multi-modal data, the establishment of correlations between consumer genetic data and product ingredients are the main obstacles encountered today. Determining to settle such obstacles, a personalised recommendation expert system for selecting optimised skin-health product within the category based upon genetic phenotypes for each consumer was introduced in this article. Random Forests were implemented to achieve automatic product categorisation, the performance discussed and compared with SVM and Logistic Regression. Lastly, categorised skin-health product suggestion was made with an optimised recommendation model based on associated genetic phenotype information. Potential changes (up to 71.0% more phenotypic relevant ingredients) from experiments using real product data were demonstrated and compared with imitated cases of real-life human selections.


Assuntos
Sistemas Inteligentes , Pele , DNA , Humanos
17.
Sci Rep ; 10(1): 4553, 2020 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-32165708

RESUMO

Breast cancer (BC) is a common cancer in women worldwide. Despite advances in treatment, up to 30% of women eventually relapse and die of metastatic breast cancer. Liquid biopsy analysis of circulating cell-free DNA fragments in the patients' blood can monitor clonality and evolving mutations as a surrogate for tumour biopsy. Next generation sequencing platforms and digital droplet PCR can be used to profile circulating tumour DNA from liquid biopsies; however, they are expensive and time consuming for clinical use. Here, we report a novel strategy with proof-of-concept data that supports the usage of loop-mediated isothermal amplification (LAMP) to detect PIK3CA c.3140 A > G (H1047R), a prevalent BC missense mutation that is attributed to BC tumour growth. Allele-specific primers were designed and optimized to detect the p.H1047R variant following the USS-sbLAMP method. The assay was developed with synthetic DNA templates and validated with DNA from two breast cancer cell-lines and two patient tumour tissue samples through a qPCR instrument and finally piloted on an ISFET enabled microchip. This work sets a foundation for BC mutational profiling on a Lab-on-Chip device, to help the early detection of patient relapse and to monitor efficacy of systemic therapies for personalised cancer patient management.


Assuntos
Neoplasias da Mama/diagnóstico , Classe I de Fosfatidilinositol 3-Quinases/genética , Técnicas de Diagnóstico Molecular/instrumentação , Mutação de Sentido Incorreto , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Neoplasias da Mama/genética , Linhagem Celular Tumoral , Primers do DNA/genética , Detecção Precoce de Câncer , Feminino , Humanos , Dispositivos Lab-On-A-Chip , Biópsia Líquida , Células MCF-7 , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Projetos Piloto , Estudo de Prova de Conceito
18.
Lancet Microbe ; 1(7): e300-e307, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32964211

RESUMO

BACKGROUND: Access to rapid diagnosis is key to the control and management of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Laboratory RT-PCR testing is the current standard of care but usually requires a centralised laboratory and significant infrastructure. We describe our diagnostic accuracy assessment of a novel, rapid point-of-care real time RT-PCR CovidNudge test, which requires no laboratory handling or sample pre-processing. METHODS: Between April and May, 2020, we obtained two nasopharyngeal swab samples from individuals in three hospitals in London and Oxford (UK). Samples were collected from three groups: self-referred health-care workers with suspected COVID-19; patients attending emergency departments with suspected COVID-19; and hospital inpatient admissions with or without suspected COVID-19. For the CovidNudge test, nasopharyngeal swabs were inserted directly into a cartridge which contains all reagents and components required for RT-PCR reactions, including multiple technical replicates of seven SARS-CoV-2 gene targets (rdrp1, rdrp2, e-gene, n-gene, n1, n2 and n3) and human ribonuclease P (RNaseP) as sample adequacy control. Swab samples were tested in parallel using the CovidNudge platform, and with standard laboratory RT-PCR using swabs in viral transport medium for processing in a central laboratory. The primary analysis was to compare the sensitivity and specificity of the point-of-care CovidNudge test with laboratory-based testing. FINDINGS: We obtained 386 paired samples: 280 (73%) from self-referred health-care workers, 15 (4%) from patients in the emergency department, and 91 (23%) hospital inpatient admissions. Of the 386 paired samples, 67 tested positive on the CovidNudge point-of-care platform and 71 with standard laboratory RT-PCR. The overall sensitivity of the point-of-care test compared with laboratory-based testing was 94% (95% CI 86-98) with an overall specificity of 100% (99-100). The sensitivity of the test varied by group (self-referred healthcare workers 94% [95% CI 85-98]; patients in the emergency department 100% [48-100]; and hospital inpatient admissions 100% [29-100]). Specificity was consistent between groups (self-referred health-care workers 100% [95% CI 98-100]; patients in the emergency department 100% [69-100]; and hospital inpatient admissions 100% [96-100]). Point of care testing performance was similar during a period of high background prevalence of laboratory positive tests (25% [95% 20-31] in April, 2020) and low prevalence (3% [95% 1-9] in inpatient screening). Amplification of viral nucleocapsid (n1, n2, and n3) and envelope protein gene (e-gene) were most sensitive for detection of spiked SARS-CoV-2 RNA. INTERPRETATION: The CovidNudge platform was a sensitive, specific, and rapid point of care test for the presence of SARS-CoV-2 without laboratory handling or sample pre-processing. The device, which has been implemented in UK hospitals since May, 2020, could enable rapid decisions for clinical care and testing programmes. FUNDING: National Institute of Health Research (NIHR) Imperial Biomedical Research Centre, NIHR Health Protection Research Unit in Healthcare Associated Infections and Antimicrobial Resistance at Oxford University in partnership with Public Health England, NIHR Biomedical Research Centre Oxford, and DnaNudge.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Testes Imediatos , RNA Viral/genética , Sensibilidade e Especificidade
19.
Front Neurosci ; 13: 808, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31481864

RESUMO

Closed-loop or intelligent neuromodulation allows adjustable, personalized neuromodulation which usually incorporates the recording of a biomarker, followed by implementation of an algorithm which decides the timing (when?) and strength (how much?) of stimulation. Closed-loop neuromodulation has been shown to have greater benefits compared to open-loop neuromodulation, particularly for therapeutic applications such as pharmacoresistant epilepsy, movement disorders and potentially for psychological disorders such as depression or drug addiction. However, an important aspect of the technique is selection of an appropriate, preferably neural biomarker. Neurochemical sensing can provide high resolution biomarker monitoring for various neurological disorders as well as offer deeper insight into neurological mechanisms. The chemicals of interest being measured, could be ions such as potassium (K+), sodium (Na+), calcium (Ca2+), chloride (Cl-), hydrogen (H+) or neurotransmitters such as dopamine, serotonin and glutamate. This review focusses on the different building blocks necessary for a neurochemical, closed-loop neuromodulation system including biomarkers, sensors and data processing algorithms. Furthermore, it also highlights the merits and drawbacks of using this biomarker modality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA