Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Glaucoma ; 15(5): 371-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16988598

RESUMO

PURPOSE: Nonpupil block mechanisms and appositional angle closure after laser iridotomy (LI) have been reported as common findings in Asians. We evaluated the presence of these findings in a cohort of Brazilian patients using ultrasound biomicroscopy (UBM). METHODS: This observational case-control study included 22 open angle eyes and 31 eyes with occludable angles on gonioscopy (defined by 2 examiners). UBM radial scans through a typical ciliary process were obtained in both light and dark conditions, at 6 and 12-o'clock positions. Long ciliary processes with no ciliary sulcus were determined on the basis of a reference line drawn perpendicular to the iris plane passing through a point located 750 mum from scleral spur. Trabecular ciliary processes distance was measured on 6-o'clock UBM images. RESULTS: After LI, 52% of occludable angle eyes had appositional angle closure in both 6 and 12-o'clock UBM images. We also observed this finding in 14% and 23% of the control eyes (in 6 and 12-o'clock UBM images, respectively). A long ciliary process with no ciliary sulcus was observed in 61% of occludable angle eyes, and also in 32% of control eyes (6-o'clock UBM images). Control eyes had longer trabecular ciliary processes distance than occludable angle eyes (P<0.001). CONCLUSIONS: The UBM finding of long ciliary processes associated with the absence of ciliary sulcus is not necessarily related to an anterior positioning of the ciliary processes. Whether UBM appositional angle closure after LI is associated with further angle closure process and/or poor intra-ocular pressure control remains to be evaluated.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Corpo Ciliar/diagnóstico por imagem , Glaucoma de Ângulo Fechado/diagnóstico por imagem , Iris/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Biometria , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Artigo em Inglês | MEDLINE | ID: mdl-25741525

RESUMO

We evaluated the ability of spectral-domain optic coherence tomography (SD-OCT) to differentiate large physiological optic disc cupping (LPC) from glaucomatous cupping in eyes with intraocular pressure (IOP) within the normal range. We prospectively enrolled patients with glaucoma or presumed LPC. Participants had optic discs with confirmed or suspected glaucomatous damage (defined as a vertical cup-to-disc ratio≥0.6), and all eyes had known untreated IOP<21 mmHg. For glaucomatous eyes, a reproducible glaucomatous visual field (VF) defect was required. LPC eyes required normal VF and no evidence of progressive glaucomatous neuropathy (follow-up≥30 months). Peripapillary retinal nerve fiber layer (pRNFL) and macular ganglion cell complex (GCC) thicknesses were obtained using SD-OCT. For all studied parameters of pRNFL and GCC thicknesses, eyes with glaucoma (n=36) had significantly thinner values compared to eyes with LPC (n=71; P<0.05 for all comparisons). In addition, pRNFL parameters had sensitivity of 66.7% and specificity of 83.1%, and GCC parameters had sensitivity of 61.2% and specificity of 81.7%. The combination of the two analyses increased the sensitivity to 80.6%. In conclusion, while evaluating patients with large optic disc cupping and IOP in the statistically normal range, SD-OCT had only limited diagnostic ability to differentiate those with and without glaucoma. Although the diagnostic ability of the pRNFL and the GCC scans were similar, these parameters yielded an increase in sensitivity when combined, suggesting that both parameters could be considered simultaneously in these cases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA