Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Angew Chem Int Ed Engl ; 58(37): 13149-13154, 2019 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-31323171

RESUMO

Despite a growing interest in CHF2 in medicinal chemistry, there is a lack of efficient methods for the insertion of CHF18 F into druglike compounds. Herein described is a photoredox flow reaction for 18 F-difluoromethylation of N-heteroaromatics that are widely used in medicinal chemistry. Following the two-step synthesis for a new 18 F-difluoromethylation reagent, the photoredox reaction is completed within two minutes and proceeds by C-H activation, circumventing the need for pre-functionalization of the substrate. The method is operationally simple and affords straightforward access to radiolabeled N-heteroaromatics with high molar activity suitable for biological in vivo studies and clinical application.


Assuntos
Radioisótopos de Flúor/química , Hidrocarbonetos Aromáticos/química , Halogenação , Hidrocarbonetos Aromáticos/síntese química , Metilação , Oxirredução , Tomografia por Emissão de Pósitrons/métodos , Radioquímica
2.
Front Chem ; 12: 1411312, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39076612

RESUMO

Gallium-68-labeled FAPI-46 has recently been proposed as a novel positron emission tomography imaging probe to diagnose and monitor a wide variety of cancers. Promising results from several ongoing clinical trials have led to a soaring demand for this radiotracer. Typical [68Ga]Ga-FAPI-46 labeling protocols do not cope with multiple generator elutions, leaving radiopharmacies unable to scale-up the production and meet the demand. Here, we propose a robust and efficient automated radiosynthesis of [68Ga]Ga-FAPI-46 on the Trasis miniAllinOne synthesizer, featuring a prepurification step which allows multiple generator elutions and ensures compatibility with a wide range of gallium-68 generators. Our approach was to optimize the prepurification step by first testing five different cationic cartridge chemistries. Only the strong cationic exchange (SCX) cartridges tested had sufficient affinities for quantitative trapping of >99.9%, while the weak cationics did not exceed 50%. Packaging, rinsing, or flowing of the selected SCX cartridges was not noticeable, but improvements in fluidics managed to save time. Based on our previous development experience of [68Ga]Ga-FAPI-46, radiolabeling optimization was also carried out at different temperatures during 10 min. At temperatures above 100°C, radiochemical yield (RCY) > 80% was achieved without significantly increasing the chemical impurities (<5.5 µg mL-1). The optimized sequence was reproducibly conducted with three different brands of widely used generators (RCY >88%). A comparison with radiosyntheses carried out without prepurification steps was also conclusive in terms of RCY, radiochemical yield, and chemical purity. Finally, high-activity tests using elutions from three generators were also successful for these parameters. [68Ga]Ga-FAPI-46 was consistently obtained in good radiochemical yields (>89%, n = 3), and the final product quality was compliant with internal specifications based on European Pharmacopoeia. This process is suitable for GMP production and allows scaling-up of routine productions, higher throughput, and, ultimately, better patient care.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA