Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(3)2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33540572

RESUMO

This paper examines the potential deployment of a 10 mm × 10 mm × 1 mm cadmium telluride detector for strontium-90 measurement in groundwater boreholes at nuclear decommissioning sites. Geant4 simulation was used to model the deployment of the detector in a borehole monitoring contaminated groundwater. It was found that the detector was sensitive to strontium-90, yttrium-90, caesium-137, and potassium-40 decay, some of the significant beta emitters found at Sellafield. However, the device showed no sensitivity to carbon-14 decay, due to the inability of the weak beta emission to penetrate both the groundwater and the detector shielding. The limit of detection for such a sensor when looking at solely strontium-90 decay was calculated as 323 BqL-1 after a 1-h measurement and 66 BqL-1 after a 24-h measurement. A gallium-arsenide (GaAs) sensor with twice the surface area, but 0.3% of the thickness was modelled for comparison. Using this sensor, sensitivity was increased, such that the limit of detection for strontium-90 was 91 BqL-1 after 1 h and 18 BqL-1 after 24 h. However, this sensor sacrifices the potential to identify the present radionuclides by their end-point energy. Additionally, the feasibility of using flexible detectors based on solar cell designs to maximise the surface area of detectors has been modelled.

2.
Sensors (Basel) ; 21(17)2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34502622

RESUMO

The in-situ characterisation of strontium-90 contamination of groundwater at nuclear decommissioning sites would represent a novel and cost-saving technology for the nuclear industry. However, beta particles are emitted over a continuous spectrum and it is difficult identify radionuclides due to the overlap of their spectra and the lack of characteristic features. This can be resolved by using predictive modelling to perform a maximum-likelihood estimation of the radionuclides present in a beta spectrum obtained with a semiconductor detector. This is achieved using a linear least squares linear regression and relating experimental data with simulated detector response data. In this case, by simulating a groundwater borehole scenario and the deployment of a cadmium telluride detector within it, it is demonstrated that it is possible to identify the presence of 90Sr, 90Y, 137Cs and 235U decay. It is determined that the optimal thickness of the CdTe detector for this technique is in the range of 0.1 to 1 mm. The influence of suspended solids in the groundwater is also investigated. The average and maximum concentrations of suspended particles found at Sellafield do not significantly deteriorate the results. It is found that applying the linear regression over two energy windows improves the estimate of 90Sr activity in a mixed groundwater source. These results provide validation for the ability of in-situ detectors to determine the activity of 90Sr in groundwater in a timely and cost-effective manner.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA