Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Acta Paediatr ; 113(5): 973-979, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38305638

RESUMO

AIM: To evaluate the definition and causes of neonatal bradycardias. METHODS: This retrospective study included 135 term-born newborns referred for 24-hour Holter monitoring due to bradycardia. Bradycardia was defined as either a heart rate below 80 beats per minute (standard definition) or a heart rate below our recently published age-specific reference values for neonatal heart rate. RESULTS: The mean (SD) age was 6.1 (1.3) days. With standard definition, 107 newborns (79%) had bradycardia, whereas only 20 (15%) had a minimum heart rate lower than the age-specific reference. Younger newborns had lower heart rates. Each day increased the minimum, mean and maximum heart rate by 1.8 (95% CI: 1.0, 2.6), 4.2 (95% CI: 3.0, 5.3) and 2.1 beats per minute (95% CI: 0.3, 3.8), respectively. Male sex and maternal levothyroxine medication were negatively associated with the mean and maximum heart rate. None of the newborns had a cardiac cause for low heart rate. CONCLUSION: Among term newborns with bradycardias, younger age, male sex and maternal levothyroxine medication were associated with a lower heart rate on Holter monitoring. Given the age-related increase in heart rate, the 80 beats per minute limit as a universal threshold for abnormal heart rate in newborns appears inappropriate.


Assuntos
Bradicardia , Tiroxina , Humanos , Masculino , Recém-Nascido , Frequência Cardíaca/fisiologia , Bradicardia/induzido quimicamente , Tiroxina/uso terapêutico , Estudos Retrospectivos , Família
2.
Eur J Pediatr ; 182(5): 2359-2367, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36884089

RESUMO

To evaluate heart rate (HR), the presence of extrasystoles and other Holter findings among healthy newborns, and to collect data for new normal limits for Holter parameters in newborns. For this cross-sectional study, 70 healthy term newborns were recruited to undergo 24-h Holter monitoring. Linear regression analysis was used in HR analyses. The age-specific limits for HRs were calculated using linear regression analysis coefficients and residuals. The mean (SD) age of the infants was 6.4 (1.7) days during the recording. Each consecutive day of age raised the minimum and mean HR by 3.8 beats per minute (bpm) (95% CI: 2.4, 5.2; P < .001) and 4.0 bpm (95% CI: 2.8, 5.2; P < .001), respectively. Age did not correlate with maximum HR. The lowest calculated limit for minimum HR ranged from 56 bpm (aged 3 days) to 78 bpm (aged 9 days). A small number of atrial extrasystoles and ventricular extrasystoles were observed in 54 (77%) and 28 (40%) recordings, respectively. Short supraventricular or ventricular tachycardias were found in 6 newborns (9%). CONCLUSION:  The present study shows an increase of 20 bpm in both the minimum and mean HRs of healthy term newborns between the 3rd and 9th days of life. Daily reference values for HR could be adopted in the interpretation of HR monitoring results in newborns. A small number of extrasystoles are common in healthy newborns, and isolated short tachycardias may be normal in this age group. WHAT IS KNOWN: • The current definition of bradycardia in newborns is 80 beats per minute. • This definition does not fit into the modern clinical setting of continuously monitored newborns, where benign bradycardias are commonly observed. WHAT IS NEW: • A linear and clinically significant increase in heart rate was observed in infants between the ages of 3 and 9 days. • It appears as though lower normal limits for heart rate could be applied to the youngest newborns.


Assuntos
Complexos Cardíacos Prematuros , Eletrocardiografia Ambulatorial , Lactente , Humanos , Recém-Nascido , Frequência Cardíaca/fisiologia , Eletrocardiografia Ambulatorial/métodos , Estudos Transversais , Valores de Referência
3.
Acta Paediatr ; 111(5): 979-984, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35100437

RESUMO

AIM: To retrospectively assess the indications for and findings on 24-hour electrocardiographic (Holter) monitoring in newborns, focussing on bradycardias and extrasystoles. METHODS: Data included 337 term-born infants. Holter indications were categorised into bradycardias below 80 beats per minute, extrasystoles, any tachycardia and other. Heart rate below 60 beats per minute, pathological atrioventricular conduction, supraventricular or ventricular tachycardia, or either atrial premature contractions over 10% or ventricular premature contractions over 5% of total beats were defined as significant arrhythmia on Holter. RESULTS: The median age was 6 days (range: 2-62 days). Bradycardia (42%) or extrasystoles (32%) were the most common Holter indications. Fifty-three infants (16%) had significant arrhythmia on Holter. Heart disease or 12-lead electrocardiogram expressing extrasystoles or conduction abnormalities were associated with significant arrhythmias (p = 0.046 and p < 0.001, respectively). Twenty-seven of 109 infants (25%) with extrasystoles as a Holter indication had abnormal Holter results, but only seven (6.4%) had significant arrhythmia on Holter if the 12-lead electrocardiogram was normal. No pathology was found behind bradycardias below 80 beats per minute in the absence of heart disease. CONCLUSION: Among term newborns with extrasystoles or bradycardias, Holter monitoring could be targeted to infants with heart disease or abnormal electrocardiograms.


Assuntos
Bradicardia , Cardiopatias , Arritmias Cardíacas/diagnóstico , Bradicardia/diagnóstico , Complexos Cardíacos Prematuros , Criança , Eletrocardiografia/métodos , Humanos , Recém-Nascido , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA