1.
Pacing Clin Electrophysiol ; 42(7): 862-867, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30989679

RESUMO

BACKGROUND: Choosing the appropriate animal model for development of novel technologies requires an understanding of anatomy and physiology of these different models. There are little data about the characteristics of different animal models for the study of technologies used for epicardial ablation. We aimed to compare the incidence of ventricular arrhythmias during epicardial radiofrequency ablation between swine and canine models using novel epicardial ablation catheters. METHODS: We conducted a retrospective study using data obtained from epicardial ablation experiments performed on swine (Sus Scrofa) and canine (Canis familiaris) models. We compared the incidence of ventricular arrhythmias during ablation between swine and canine using multivariate regression analysis. Six swine and six canine animals underwent successful epicardial radiofrequency ablation. A total of 103 ablation applications were recorded. RESULTS: Ventricular arrhythmias requiring cardioversion occurred in 13.11% of radiofrequency ablation applications in swine and 9.75% in canine (relative risk: 117.6%, 95% confidence interval [CI]: 83.97-164.69, animal-based odds ratio [OR]: .55, 95% CI: .23-61.33; P = .184). When adjusting for application position, duration of ablation and power, the odds of developing potentially lethal ventricular arrhythmia in swine increased significantly compared to canine (OR: 3.60, 95% CI: 1.35-9.55; P = .010). CONCLUSIONS: The swine myocardium is more susceptible to developing ventricular arrhythmias compared to canine model during epicardial ablation. This issue should be carefully considered in future studies.


Assuntos
Ablação por Cateter/métodos , Modelos Animais de Doenças , Pericárdio/cirurgia , Taquicardia Ventricular/etiologia , Animais , Cães , Incidência , Estudos Retrospectivos , Suínos
2.
Pacing Clin Electrophysiol ; 42(3): 366-373, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30632622

RESUMO

BACKGROUND: Leadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers. METHODS: Patients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age- and sex-matched controls receiving single-chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA). RESULTS: Ninety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow-up duration of 62 (interquartile range 28-169) days. Both groups had 100% successful device implant rates. There were no differences in procedure-related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device-related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017). CONCLUSION: There are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device-related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.


Assuntos
Doenças Cardiovasculares/terapia , Desenho de Equipamento , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Torácicos , Estados Unidos
3.
J Cardiovasc Electrophysiol ; 29(9): 1308-1316, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29882395

RESUMO

BACKGROUND: Transvenous lead implantation has multiple drawbacks and complications that can be overcome by epicardial lead placement. We aimed to design percutaneously implanted epicardial leads that are anchored through the transverse sinus (TS). METHODS AND RESULTS: We designed a novel multielectrode pacing device with four bipole electrode pairs. The device is advanced through the TS, with both ends externalized out of the pericardium. We tested the prototype in one proof-of-concept and 5 additional acute canine experiments. The TS device recorded ventricular and atrial electrograms. The median amplitude of near-field ventricular electrograms was 3.3 mA (IQR 2.0-4.3) and of near-field atrial electrograms was 2.1 mA (IQR 1.3-2.2). The median ventricular threshold (N  =  30) was 1.1 mA (IQR 0.7-3.1) at a median pulse width of 0.5 ms (IQR 0.5-0.5). The median atrial threshold (N  =  10) was 2.4 mA (IQR 1.1-7.8) at a median pulse width of 0.5 ms (IQR 0.5-0.9). Right and left ventricular and atrial pacing morphologies were noted while pacing electrodes adjacent to these chambers. Simultaneous left (LV) and right ventricular (RV) pacing showed reduction in QRS duration from 116 ms (RV) and 105 ms (LV) to 91 ms. On necropsy, the device was located in the TS in all animals. There were TS abrasions in one animal, and no other acute complications. CONCLUSIONS: This study highlights a novel approach to epicardial pacing harnessing the unique anatomy of the transverse sinus as an anchoring point. Placement of this novel transverse sinus device was safe and feasible, with acceptable atrial and ventricular thresholds.


Assuntos
Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Eletrodos Implantados , Marca-Passo Artificial , Pericárdio/cirurgia , Animais , Cães , Humanos , Masculino , Pericárdio/diagnóstico por imagem , Pericárdio/fisiologia
4.
J Electrocardiol ; 51(6): 1103-1109, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30497739

RESUMO

AIMS: Non-cardiologists (NCs) are often responsible for the preliminary diagnosis and early management of patients presenting with ventricular tachycardia (VT) or supraventricular wide complex tachycardia (SWCT). At present, the Vereckei aVR and Brugada algorithms are the most widely recognized and frequently relied upon wide complex tachycardia (WCT) differentiation criteria by NCs. This study aimed to determine the diagnostic efficacy of the Vereckei aVR and Brugada algorithms when applied by NCs. METHODS: In a blinded fashion, three internal medicine residents prospectively interpreted WCTs using the Vereckei aVR and Brugada algorithms. The diagnostic performance of each method was evaluated according to their agreement with the correct rhythm diagnosis. RESULTS: Two-hundred sixty-nine WCTs (160 VT, 109 SWCT) from 186 patients were independently interpreted by each participant (807 separate interpretations per algorithm). The aVR and Brugada algorithms accurately classified 546 out of 807 (67.7%) and 622 out of 807 (77.1%) interpreted WCTs, respectively. Overall sensitivity and specificity of the aVR algorithm for VT was 92.1% and 31.8%, respectively. Overall sensitivity and specificity of the Brugada algorithm for VT was 89.4% and 59.0%, respectively. Both algorithms yielded modestly favorable overall positive predictive values (aVR 66.5%; Brugada 76.2%) and negative predictive values (73.3%; Brugada 79.1%). CONCLUSION: Non-cardiologist algorithm users correctly identified most "actual" VTs, but did not sufficiently revise VT probability to conclusively distinguish VT and SWCT. Newer WCT differentiation methods are needed to improve NC's ability to accurately differentiate WCTs.


Assuntos
Algoritmos , Eletrocardiografia/métodos , Medicina Interna/educação , Internato e Residência , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sensibilidade e Especificidade , Adulto Jovem
5.
Pacing Clin Electrophysiol ; 40(3): 310-322, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27943333

RESUMO

BACKGROUND: Echocardiographically detected patent foramen ovale (PFO) has been associated with stroke/transient ischemic attack (TIA) in patients with cardiac implantable electronic devices (CIEDs). We sought to evaluate the relationship between echocardiographic characteristics and risk of stroke/TIA and mortality in CIED patients with PFO. METHODS: In 6,086 device patients, PFO was detected in 319 patients. A baseline echocardiogram was present in 250 patients, with 186 having a follow-up echocardiogram. RESULTS: Of 250 patients with a baseline echocardiogram, 9.6% (n = 24) had a stroke/TIA during mean follow-up of 5.3 ± 3.1 years; and 42% (n = 105) died over 7.1 ± 3.7 years. Atrial septal aneurysm, prominent Eustachian valve, visible shunting across PFO, baseline or change in estimated right ventricular systolic pressure (RVSP)/tricuspid regurgitation (TR), or maximum RVSP were not associated with postimplant stroke/TIA (P > 0.05). An exploratory multivariate analysis using time-dependent Cox models showed increased hazard of death in patients with increase in TR ≥2 grades (hazard ratio [HR] 1.780, 95% confidence interval [CI] 1.447-2.189, P < 0.0001), or increase in RVSP by >10 mm Hg (HR 2.018, 95% CI 1.593-2.556, P < 0.0001), or maximum RVSP in follow-up (HR 1.432, 95% CI 1.351-1.516, P < 0.0001). A significant increase (P < 0.001) in TR was also noted during follow-up. CONCLUSIONS: In patients with CIED and PFO, structural and hemodynamic echocardiographic markers did not predict future stroke/TIA. However, a significantly higher TR or RVSP was associated with higher mortality.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Ecocardiografia/estatística & dados numéricos , Forame Oval Patente/mortalidade , Ataque Isquêmico Transitório/mortalidade , Marca-Passo Artificial/estatística & dados numéricos , Acidente Vascular Cerebral/mortalidade , Idoso , Causalidade , Comorbidade , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Minnesota/epidemiologia , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Estatística como Assunto , Taxa de Sobrevida
6.
Echocardiography ; 34(11): 1708-1711, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28942610

RESUMO

Among patients undergoing cardioversion for atrial fibrillation, the presence of left ventricular thrombus is a relatively uncommon and challenging clinical dilemma. While left atrial appendage thrombus is a contraindication to cardioversion, there is paucity of data regarding the safety of cardioversion in with the presence of left ventricular apical thrombus. Also, thrombus characteristics such as protrusion and mobility on echocardiography are known risk factors for systemic embolism. In this article, we present a case highlighting the management of atrial fibrillation in the setting of left ventricular dysfunction, acute heart failure, and echocardiographic evidence of acute left ventricular apical thrombus.


Assuntos
Fibrilação Atrial/terapia , Trombose Coronária/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Cardioversão Elétrica/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Doença Aguda , Idoso , Fibrilação Atrial/complicações , Trombose Coronária/complicações , Trombose Coronária/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Fatores de Risco , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia
7.
Indian Pacing Electrophysiol J ; 22(2): 87-90, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35272855
8.
Europace ; 18(2): 246-52, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25767086

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are commonly associated with transvenous lead-related thrombi that can cause pulmonary embolism (PE). METHODS AND RESULTS: We retrospectively evaluated all patients with transvenous CIED leads implanted at Mayo Clinic Rochester between 1 January 2000, and 25 October 2010. Pulmonary embolism outcomes during follow-up were screened using diagnosis codes and confirmed with imaging study reports. Of 5646 CIED patients (age 67.3 ± 16.3 years, 64% men, mean follow-up 4.69 years) 88 developed PE (1.6%), incidence 3.32 [95% confidence interval (CI) 2.68-4.07] per 1000 person-years [men: 3.04 (95% CI 2.29-3.96) per 1000 person-years; women: 3.81 (95% CI 2.72-5.20) per 1000 person-years]. Other than transvenous CIED lead(s), 84% had another established risk factor for PE such as deep vein thrombosis (28%), recent surgery (27%), malignancy (25%), or prior history of venous thromboembolism (15%). At the time of PE, 22% had been hospitalized for ≥ 48 h, and 59% had been hospitalized in the preceding 30 days. Pulmonary embolism occurred in 22% despite being on systemic anticoagulation therapy. Out of 88 patients with PE, 45 subsequently died, mortality rate 93 (95% CI 67-123) per 1000 person-years (hazard ratio 2.0, 95% CI 1.5-2.7, P < 0.0001). CONCLUSIONS: Though lead-related thrombus is commonly seen in patients with transvenous CIED leads, clinical PE occurs with a low incidence. It is possible that embolism of lead thrombus is uncommon or emboli are too small to cause consequential pulmonary infarction.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Embolia Pulmonar/epidemiologia , Trombose/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Modelos de Riscos Proporcionais , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Trombose/diagnóstico por imagem , Trombose/mortalidade , Fatores de Tempo , Adulto Jovem
10.
Indian Pacing Electrophysiol J ; 16(1): 19-30, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27485561

RESUMO

Although great strides have been made in the areas of ventricular pacing, it is still appreciated that dyssynchrony can be malignant, and that appropriately placed pacing leads may ameliorate mechanical dyssynchrony. However, the unknowns at present include: 1. The mechanisms by which ventricular pacing itself can induce dyssynchrony; 2. Whether or not various pacing locations can decrease the deleterious effects caused by ventricular pacing; 3. The impact of novel methods of pacing, such as atrioventricular septal, lead-less, and far-field surface stimulation; 4. The utility of ECG and echocardiography in predicting response to therapy and/or development of dyssynchrony in the setting of cardiac resynchronization therapy (CRT) lead placement; 5. The impact of ventricular pacing-induced dyssynchrony on valvular function, and how lead position correlates to potential improvement. This review examines the existing literature to put these issues into context, to provide a basis for understanding how electrical, mechanical, and functional aspects of the heart can be distorted with ventricular pacing. We highlight the central role of the mitral valve and its function as it relates to pacing strategies, especially in the setting of CRT. We also provide future directions for improved pacing modalities via alternative pacing sites and speculate over mechanisms on how lead position may affect the critical function of the mitral valve and thus overall efficacy of CRT.

11.
Indian Pacing Electrophysiol J ; 16(6): 187-191, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28401865

RESUMO

BACKGROUND: Bileaflet mitral valve prolapse (biMVP) is associated with frequent ventricular ectopy (VE) and malignant ventricular arrhythmia. We examined the effect of mitral valve (MV) surgery on VE burden in biMVP patients. METHODS: We included 32 consecutive patients undergoing MV surgery for mitral regurgitation secondary to biMVP between 1993 and 2012 at Mayo Clinic who had available pre- and post-operative Holter monitoring data. Characteristics of patients with a significant reduction in postoperative VE (group A, defined as >10% reduction in VE burden compared to baseline) were compared with the rest of study patients (group B). RESULTS: In the overall cohort, VE burden was unchanged after the surgery (41 interquartile range [16, 196] pre-surgery vs. 40 interquartile range [5186] beats/hour [bph] post-surgery; P = 0.34). However, in 17 patients (53.1%), VE burden decreased by at least 10% after the surgery. These patients (group A) were younger than the group B (59 ± 15 vs. 68 ± 7 years; P = 0.04). Other characteristics including pre- and postoperative left ventricular function and size were similar in both groups. Age <60 years was associated with a reduction in postoperative VE (odds ratio 5.8; 95% confidence interval, 1.1-44.7; P = 0.03). Furthermore, there was a graded relationship between age and odds of VE reduction with surgery (odds ratio 1.9; 95% confidence interval 1.04-4.3 per 10-year; P = 0.04). CONCLUSIONS: MV surgery does not uniformly reduce VE burden in patients with biMVP. However, those patients who do have a reduction in VE burden are younger, perhaps suggesting that early surgical intervention could modify the underlying electrophysiologic substrate.

12.
J Cardiovasc Electrophysiol ; 26(2): 158-63, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25425429

RESUMO

INTRODUCTION: Catheter ablation of ventricular arrhythmia (VA) at the fibrous aortic mitral continuity (AMC) has been described, yet the nature of the arrhythmogenic substrate remains unknown. METHODS: Procedural records of 528 consecutive patients undergoing ablation of VA at Mayo Clinic, Rochester, MN, were reviewed. The electrocardiographic and electrophysiologic characteristics of patients with successful ablation at the AMC were analyzed to characterize the underlying arrhythmogenic substrate. RESULTS: Of the 21 patients (mean age 53.2 ± 13.4 years, 47.6% male) who underwent ablation of VA at the AMC with acute success, prepotentials (PPs) were found at the ablation sites preceding the ventricular electrogram (VEGM) during arrhythmias in 13 (61.9%) patients and during sinus rhythm in 7 (53.8%) patients. VAs with PPs were associated with a significantly higher burden of premature ventricular complexes (PVCs; 26.1 ± 10.9% vs. 14.9 ± 10.1%, P = 0.03), shorter VEGM to QRS intervals (9.0 ± 28.5 milliseconds vs. 33.1 ± 8.8 milliseconds, P = 0.03), lower pace map scores (8.7 ± 1.6 vs. 11.4 ± 0.8, P = 0.001), and a trend toward shorter V-H intervals during VA (32.1 ± 38.6 milliseconds vs. 76.3 ± 11.1 milliseconds, P = 0.06) as compared to those without PP. A strong and positive correlation was found between V-H interval and QRS duration during arrhythmia in those with PPs (B = 2.11, R(2) = 0.97, t = 13.7, P < 0.001) but not in those without PPs. CONCLUSION: Local EGM characteristics and relative activation time of the His bundle suggest the possibility of conduction tissue as the origin for VA arising from the fibrous AMC. Specific identification and targeting of PPs when ablating VAs at this location may improve procedural success.


Assuntos
Valva Aórtica/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Valva Mitral/fisiopatologia , Taquicardia Ventricular/diagnóstico , Complexos Ventriculares Prematuros/diagnóstico , Potenciais de Ação , Adulto , Idoso , Valva Aórtica/cirurgia , Fascículo Atrioventricular/fisiopatologia , Ablação por Cateter , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Valva Mitral/cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
13.
Circulation ; 128(13): 1433-41, 2013 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-23946264

RESUMO

BACKGROUND: A patent foramen ovale (PFO) may permit arterial embolization of thrombi that accumulate on the leads of cardiac implantable electronic devices in the right-sided cardiac chambers. We sought to determine whether a PFO increases the risk of stroke/transient ischemic attack (TIA) in patients with endocardial leads. METHODS AND RESULTS: We retrospectively evaluated all patients who had endocardial leads implanted between January 1, 2000, and October 25, 2010, at Mayo Clinic Rochester. Echocardiography was used to establish definite PFO and non-PFO cohorts. The primary end point of stroke/TIA consistent with a cardioembolic etiology and the secondary end point of mortality during postimplantation follow-up were compared in PFO versus non-PFO patients with the use of Cox proportional hazards models. We analyzed 6075 patients (364 with PFO) followed for a mean 4.7 ± 3.1 years. The primary end point of stroke/TIA was met in 30/364 (8.2%) PFO versus 117/5711 (2.0%) non-PFO patients (hazard ratio, 3.49; 95% confidence interval, 2.33-5.25; P<0.0001). The association of PFO with stroke/TIA remained significant after multivariable adjustment for age, sex, history of stroke/TIA, atrial fibrillation, and baseline aspirin/warfarin use (hazard ratio, 3.30; 95% confidence interval, 2.19-4.96; P<0.0001). There was no significant difference in all-cause mortality between PFO and non-PFO patients (hazard ratio, 0.91; 95% confidence interval, 0.77-1.07; P=0.25). CONCLUSIONS: In patients with endocardial leads, the presence of a PFO on routine echocardiography is associated with a substantially increased risk of embolic stroke/TIA. This finding suggests a role of screening for PFOs in patients who require cardiac implantable electronic devices; if a PFO is detected, PFO closure, anticoagulation, or nonvascular lead placement may be considered.


Assuntos
Desfibriladores Implantáveis , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/epidemiologia , Ataque Isquêmico Transitório/epidemiologia , Marca-Passo Artificial , Acidente Vascular Cerebral/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Forame Oval Patente/terapia , Humanos , Ataque Isquêmico Transitório/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Taxa de Sobrevida/tendências
15.
J Cardiovasc Electrophysiol ; 25(1): 94-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24102678

RESUMO

Catheter ablation is an increasingly used and successful treatment choice for right ventricular outflow tract (RVOT) arrhythmias. While the role of endocavitary structures and the regional morphology of the ventricular inflow tract and the right atrium as a cause for difficulty with successful ablation are well described, similar issues within the RVOT are not well understood. It is also not commonly appreciated that one of the papillary muscles is located within the proximal RVOT. We report 3 patients in which ventricular arrhythmia was targeted and ablated in the conus papillary muscle. The anatomic features, potential role of the fascicular conduction system, and unique challenges with mapping arrhythmia arising from this structure are discussed.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Músculos Papilares/anatomia & histologia , Músculos Papilares/fisiologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
16.
J Cardiovasc Electrophysiol ; 25(7): 781-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24758340

RESUMO

BACKGROUND: Hemodynamic instability hinders activation and entrainment mapping during ventricular tachycardia ablation. The Impella 2.5 microaxial flow device (MFD; Abiomed Inc., Danvers, MA, USA) is used to prevent hemodynamic instability during electrophysiologic study. However, electromagnetic interference (EMI) generated by this device can preclude accurate electroanatomic mapping. METHODS: Impella was placed in the left ventricle of 7 canines for circulatory support. Electroanatomic mapping during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF) was performed using magnet- (CARTO3, Biosense Webster Inc., Diamond Bar, CA, USA) and impedance- (EnSite Velocity System/EnSite NavX, St. Jude Medical Inc., St. Paul, MN, USA) based systems. Distance from device to points with severe EMI precluding acquisition was compared to points with mild/no EMI. Two methods were used to reduce EMI: (1) titration of MFD performance, and (2) impedance-only mapping combined with manual annotation of activation. RESULTS: Severe EMI did not occur during impedance-based mapping. Severe EMI was observed using CARTO3 at 9.4% of all points attempted at maximum performance level (P8) of device. Severe EMI occurred at points closer to device (40.1 ± 16.8 mm) versus (55.5 ± 20.0 mm) for mild/no EMI, P < 0.0001. Severe EMI using CARTO3 was resolved by either (1) reduction of performance from P8 to P6 or (2) impedance-only mapping with manual annotation. CONCLUSION: Concurrent use of MFD caused EMI to prevent acquisition of points with magnet-based mapping. Predictors for EMI were distance from device and performance level. Temporary reductions to P6 or impedance-only mapping are 2 methods to resolve EMI.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/instrumentação , Coração Auxiliar , Implantação de Prótese/instrumentação , Fibrilação Ventricular/diagnóstico , Função Ventricular Esquerda , Animais , Estimulação Cardíaca Artificial , Modelos Animais de Doenças , Cães , Impedância Elétrica , Campos Eletromagnéticos , Falha de Equipamento , Hemodinâmica , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Fibrilação Ventricular/fisiopatologia
17.
J Cardiovasc Electrophysiol ; 25(9): 971-975, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24758402

RESUMO

INTRODUCTION: An increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation-related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes. METHODS: We searched the Mayo Clinic MV surgical database over a 19-year period (1993-2012) and the electrophysiologic procedures database over a 23-year period (1990-2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention. RESULTS: Indications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left-sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure. CONCLUSION: Circular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.


Assuntos
Ablação por Cateter/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Valva Mitral/lesões , Adulto , Idoso , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Adulto Jovem
20.
JACC Clin Electrophysiol ; 8(1): 88-100, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34454890

RESUMO

OBJECTIVES: This study sought to describe trends in cardiovascular implantable electronic device (CIED) insertion over the past 3 decades in Olmsted County. BACKGROUND: Trends in CIED insertion in the United States have not been extensively studied. METHODS: The Rochester Epidemiology Project is a medical records linkage system comprising the records of all residents of Olmsted County from 1966 to the present. CIED insertion between 1988 and 2018 was determined using International Classification of Diseases-Ninth Revision, International Classification of Diseases-10th Revision, and Current Procedural Terminology codes. Age- and sex-adjusted incidence rates, adjusted to the 2010 US White population, were calculated. Trends in incidence over time, across age groups, and between sex are estimated using Poisson regression models. RESULTS: The age- and sex-adjusted incidence of device implants for the study period were as follows: overall CIED: 82.4 (95% CI: 79.2-85.6); permanent pacemaker (PPM): 62.9 (95% CI: 60.0-65.7); implantable cardioverter-defibrillator (ICD): 14.0 (95% CI: 12.6-15.3); and cardiac resynchronization therapy (CRT): 5.6 (95% CI: 4.7-6.4) per 100,000 per year. The overall incidence of CIED insertion increased between 1988 to 1993 and 2000 to 2005 and then decreased between 2000 to 2005 and 2012 to 218 (P < 0.0001). PPM and ICD insertion incidence followed these trends, whereas the incidence of CRT insertion increased between 2000 to 2005 and 2012 to 2018. CIED insertion incidence increased with age (P < 0.0001). CIED insertion incidence was greater in men (116.3 vs 57.3 per 100,000 per year in men vs women; P < 0.0001). The overall survival of CRT recipients improved (P = 0.0044). CONCLUSIONS: The incidence values for PPM and ICD implants are decreasing, while the incidence of CRT implants is increasing. CIEDs are increasingly inserted in the elderly, men, and patients with higher comorbidities.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Eletrônica , Feminino , Humanos , Masculino , Fatores de Risco , Estados Unidos/epidemiologia