Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 308
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(2): 149, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355823

RESUMO

OBJECTIVE: The study aims to evaluate the shear bond and flexural strength fatigue behavior of yttrium-stabilized zirconia (4YSZ) repaired using different resin composites. MATERIALS AND METHODS: Cylindric specimens of 4YSZ were obtained for the bond strength (Ø = 6 mm, 1.5 mm of thickness) and biaxial flexural strength (Ø = 15 mm, 1 mm of thickness) fatigue tests and divided into 3 groups according to the repair resin composite: EVO (nanohybrid), BULK (bulk-fill), and FLOW (flowable). The zirconia surface was air-abraded with alumina particles, a 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer was applied, and the resin composite was build-up over the zirconia. Fatigue shear bond strength and flexural fatigue strength tests were performed (n = 15). One-way ANOVA and Tukey post hoc tests were carried out for both outcomes, besides scanning electron microscopy and finite element analysis. RESULTS: The repair material affected the fatigue shear bond strength of zirconia ceramic. The BULK group (18.9 MPa) depicted higher bond strength values than FLOW (14.8 MPa) (p = 0.04), while EVO (18.0 MPa) showed similar results to both groups. No effect was observed for the mechanical behavior (p = 0.53). The stress distribution was similar for all groups. CONCLUSION: The repair of yttrium-stabilized zirconia (4YSZ) ceramics with bulk-fill resin composites was the best option for high fatigue bond strength. However, the fatigue mechanical performance was similar regardless of the applied repair material. CLINICAL RELEVANCE: The repair of yttrium-stabilized zirconia (4YSZ) monolithic restorations may be performed with nanohybrid and bulk-fill resin composites in order to promote longevity in the treatment.


Assuntos
Colagem Dentária , Metacrilatos , Colagem Dentária/métodos , Propriedades de Superfície , Teste de Materiais , Resinas Compostas/química , Zircônio/química , Cerâmica/química , Resistência ao Cisalhamento , Ítrio/química , Cimentos de Resina/química , Análise do Estresse Dentário
2.
J Prosthet Dent ; 131(5): 811.e1-811.e10, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38480018

RESUMO

STATEMENT OF PROBLEM: The influence of computer-aided manufacturing (CAM) parameters and settings on the outcomes of milled indirect restorations is poorly understood. PURPOSE: The purpose of this scoping review was to summarize the current CAM systems, parameters, and setting changes, and their effects on different outcomes of milled indirect restorations and aspects related to their manufacture. MATERIAL AND METHODS: The protocol of this review is available online (https://osf.io/x28ps/). Studies that used at least 2 different parameters (CAM units, number of axes, digital spacers, or protocols with different rotatory instruments, grit-sizes, milling speed, or others) for milling indirect restorations were included. A structured search up to July 2023 was performed by 2 independent reviewers for articles written in English in LILACS, MEDLINE via PubMed, EMBASE, Web of Science, and Scopus. RESULTS: Of 1546 studies identified, 22 were included in the review. Discrepancies were found between the planned and actual measured cement space, with a decreasing linear relationship impacting restoration adaptation at different points. The CEREC MC XL milling machine was the most used system in the included studies, with variations in bur types, milling modes, and number of burs uses affecting internal fit and surface trueness. The results demonstrated the better adaptation of restorations made with 5-axis over 3-axis milling machines. Lithium disilicate and zirconia were the most commonly used materials, and crowns and inlays were popular designs. Marginal and internal adaptation were the primary outcomes assessed using the various techniques. CONCLUSIONS: The study presented a comprehensive exploration of CAM systems and parameters, and their influence on indirect restorations. The planned cement space was not properly reproduced by the milling. Bur characteristics can affect restoration fit and trueness. The 5-axis units seem to result in better-adapted restorations compared with 3- and 4-axis units.


Assuntos
Desenho Assistido por Computador , Planejamento de Prótese Dentária , Humanos , Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos , Adaptação Marginal Dentária
3.
J Prosthodont ; 33(4): 389-395, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37201944

RESUMO

PURPOSE: This study evaluated the fatigue failure load (FFL) and the number of cycles for fatigue failure (CFF) of traditional (porcelain layer up) and reversed (zirconia layer up) designs of porcelain-veneered zirconia samples prepared with heat-pressing or file-splitting techniques. MATERIALS AND METHODS: Zirconia discs were prepared and veneered with heat-pressed or machined feldspathic ceramic. The bilayer discs were bonded onto a dentin-analog according to the bilayer technique and sample design: traditional heat-pressing (T-HP), reversed heat-pressing (R-HP), traditional file-splitting with fusion ceramic (T-FC), reversed file-splitting with fusion ceramic R-FC), traditional file-splitting with resin cement (T-RC), and reversed file-splitting with resin cement (R-RC). The fatigue tests were performed using the stepwise approach at 20 Hz, 10,000 cycles/step, step-size of 200 N starting at 600 N, and proceeding until failure detection or up to 2600 N if enduring. The failure modes (from radial and/or cone cracks) were analyzed in a stereomicroscope. RESULTS: The reversed design decreased the FFL and CFF of bilayers prepared with heat-pressing and file-splitting with fusion ceramic. The T-HP and T-FC reached the highest results, which were statistically similar between them. The bilayers prepared by the file-splitting with resin cement (T-RC and R-RC) were similar to the R-FC and R-HP groups regarding FFL and CFF. Almost all reverse layering samples failed by radial cracks. CONCLUSIONS: The reverse layering design did not improve the fatigue behavior of porcelain veneered zirconia samples. The three bilayer techniques behaved similarly when used in the reversed design.


Assuntos
Cerâmica , Porcelana Dentária , Cerâmica/uso terapêutico , Cerâmica/química , Porcelana Dentária/química , Coroas , Cimentos de Resina , Teste de Materiais , Propriedades de Superfície , Análise do Estresse Dentário , Zircônio/química , Falha de Restauração Dentária
4.
Clin Oral Investig ; 27(3): 1071-1078, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36030454

RESUMO

OBJECTIVES: To evaluate the longevity of metal-ceramic single crowns cemented onto resin composite prosthetic cores using a self-adhesive resin cement in a prospective clinical descriptive study. METHODS: A total of 152 teeth were endodontically treated and received resin composite prosthetic cores and metal-ceramic crowns cemented with a self-adhesive resin cement. The patients included in the sample were recalled for clinical and radiography evaluation in an up-to-106-month period after the final cementation procedures, with an average of 62 months of follow-up. 91.5% of the sample (142 teeth) were evaluated regarding the treatment survival rate, analyzed considering the loss of crown retention (crown debonding) and tooth loss as the primary outcome. In addition, post debonding, and root fracture occurrences were also recorded as secondary outcomes to evaluate the success rate of the prosthetic treatment. The aesthetic parameters were also evaluated according to the FDI criteria. The Kaplan-Meier method and Cox regression with 95% confidence interval were applied for the statistical analysis. RESULTS: Regarding the primary outcome, the metal-ceramic crowns cemented with self-adhesive resin cement presented a high survival rate (91.5%), with 8 crown debondings and 3 tooth losses (1 due to caries and 2 due to periodontal disease) occurring after the evaluation period. For secondary outcomes, 9 root fractures and 4 post debondings occurred, generating a success rate of 72%. All crowns had a score 1 on the FDI criteria, indicating that they were clinically excellent or very good regarding the aesthetic parameters. CONCLUSION: The metal-ceramic crowns luted with a self-adhesive resin cement presented a survival rate of 91.5% after an average of 62 months of follow-up. Furthermore, the restorations remained aesthetically satisfactory over time, without changes that would indicate prosthetic retreatment. A success rate of 72% was obtained considering the secondary outcome, mainly related to intraradicular retainer failures (root fractures or post debonding). CLINICAL SIGNIFICANCE: The self-adhesive resin cement is clinically indicated for cementation of metal-ceramic crowns onto resin composite prosthetic cores.


Assuntos
Cimentos Dentários , Cimentos de Resina , Humanos , Seguimentos , Estética Dentária , Resinas Compostas , Coroas , Cimentação/métodos , Cerâmica , Teste de Materiais , Falha de Restauração Dentária
5.
Clin Oral Investig ; 27(5): 2197-2206, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36894666

RESUMO

OBJECTIVES: The objective of this study is to evaluate the longevity of two fiber post cementation strategies in a prospective, multicenter, non-inferiority, double-blind randomized controlled trial. METHODS: A total of 152 teeth, with adequate endodontic treatment and loss of coronal structure and bilateral simultaneous posterior occlusal contacts, were randomly allocated to receive glass fiber posts cemented with a conventional cementation strategy (CRC group: adhesive system + resin cement) (Adper Single Bond + RelyX ARC; 3 M-ESPE) or a self-adhesive cementation strategy (SRC group: self-adhesive resin cement; RelyX U100/U200; 3 M-ESPE). The patients were recalled annually for clinical and radiographical evaluation with a 93% recall rate (142 teeth, with 74 at CR groups and 68 at SRC group). The primary outcome was survival rate, considering the fiber post debonding (loss of retention). The secondary outcome included the success rate of the prosthetic treatment with crown debonding, post fracture, and tooth loss (not related to post failure). Both outcomes were evaluated annually. The Kaplan-Meier method and Cox regression with 95% confidence interval were used for the statistical analysis. RESULTS: For the primary outcome (failures directly related to fiber posts cementation strategy), there were 4 fiber post debondings (2 per group), 8 root fractures (3 for SRC group and 5 for CRC group), and one mixed failure (debonding combined with root fracture for CRC), with both strategies presenting similar survival rates (p = 0.331), with 88.9% for the CRC group and 90.9% for the SRC group. For the secondary outcome (failures not related to fiber post cementation strategies), there were 8 crown debondings, 3 post fractures, and 3 tooth losses, with no statistically difference between groups (p = 0.701), with 77% for SRC and 82% for CRC. CONCLUSION: Fiber post cementation strategies with conventional or self-adhesive resin cement presents similar tooth survival and success rates. TRIAL REGISTRATION: NCT01461239 CLINICAL RELEVANCE: Both adhesive cementation strategies led to high survival and success rates and are indicated for fiber post cementation, even after a long follow-up period (up to 106 months).


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Humanos , Cimentos de Resina/química , Cimentação/métodos , Cimentos Dentários/química , Taxa de Sobrevida , Estudos Prospectivos , Vidro/química , Teste de Materiais , Análise do Estresse Dentário , Dentina
6.
Clin Oral Investig ; 27(6): 2957-2968, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36781479

RESUMO

OBJECTIVES: To evaluate the effect of the remaining tooth structure and different CAD/CAM materials on the fatigue performance and failure mode of endodontically treated premolars restored with endocrowns. MATERIALS AND METHODS: Ninety maxillary premolars were endodontically treated and assigned into 6 groups (n = 15) according to the number of remaining axial walls (four, three, and two) and restorative materials (ultra-translucent zirconia 5Y-PSZ [KATANA UTML] and lithium disilicate [IPS e.max-CAD]). The specimens were subjected to cyclic fatigue loading test (initial load 200 N; 20 Hz). An incremental step load of 100 N per 10,000 cycles was applied until failure. The fatigue failure load (FFL) and number of failure cycles (CFFs) data were statistically analyzed with two-way ANOVA and Kaplan-Meier test (α = 0.05). Failed specimens were examined under a stereomicroscope 25 × and failure modes were determined. RESULTS: FFL and CFF were significantly influenced by restorative material (p < 0.05). 5Y-PSZ endocrowns showed significantly higher FFL when compared with lithium disilicate. The number of remaining walls did not affect the fatigue behavior or failure mode of the specimens. Of the lithium disilicate restorations, 51% had repairable failures, while 95% 5Y-PSZ restorations had non-repairable failures. CONCLUSIONS: Zirconia endocrowns showed better FFL than lithium disilicate endocrowns, regardless of the number of remaining axis walls. Lithium disilicate and 5Y-PSZ endocrowns showed FFL higher than the normal masticatory loads. CLINICAL RELEVANCE: Restoring endodontically treated premolars with endocrown could be a promising treatment, regardless of the remaining axial walls. However, precaution should be taken in material selection since it affects the fatigue resistance and failure mode.


Assuntos
Cerâmica , Coroas , Cerâmica/química , Dente Pré-Molar , Teste de Materiais , Falha de Restauração Dentária , Análise do Estresse Dentário , Propriedades de Superfície , Porcelana Dentária/química , Materiais Dentários , Desenho Assistido por Computador
7.
Clin Oral Investig ; 27(9): 5539-5548, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37490118

RESUMO

OBJECTIVE: To evaluate the effects of cusp inclination of the prosthetic preparation's occlusal surface and type of restorative material on the fatigue behavior, failure mode, and stress distribution of occlusal veneers. MATERIALS AND METHODS: Glass fiber-reinforced epoxy resin prosthetic preparations for occlusal veneers with three different occlusal surface cusp inclination degrees (0°, 15°, and 30°) were produced and assigned into six testing groups (n = 11) according to the cusp inclination (0°, 15°, or 30°) and type of restorative material (lithium disilicate-LD or resin composite-RC). Despite different substrate preparation cusp inclination degrees, the restorations were designed maintaining 30° inclination between the cusps at the occlusal surface and a thickness of 0.7 mm at the central groove region of the restorations to be machined in a CAD/CAM system. After cementation, the specimens were stored for about 7 days (under water at 37 °C), and subsequently submitted to a load to failure test (n = 2) and an intermittent cyclic fatigue test (n = 9) (initial load: 100 N; step size: 50 N; cycles/step: 10,000; loading frequency: 20 Hz; loading piston: 6-mm-diameter stainless steel) until observing cracks. The data were analyzed by two-way ANOVA, Kaplan-Meier, and Mantel-Cox post hoc tests. Finite element analysis (FEA) and fractographic analyses were performed. RESULTS: The fatigue performance of LD and RC occlusal veneers was evaluated based on different prosthetic preparation cusp inclinations. The 0° inclination showed the best fatigue performance for both materials (LD: 944N, RC: 861N), while the 15° and 30° inclinations had lower values (LD: 800N and 533N, RC: 739N and 717N, respectively). The study also found that for a 0° inclination, LD occlusal veneers performed better than RC ones (LD: 944 N > RC: 861N), while for a 30° inclination, RC occlusal veneers had better fatigue performance than LD ones (LD: 533N < RC: 717N). No significant difference was observed between the materials for a 15° inclination (LD: 800N = RC: 739N). The FEA results showed a higher tensile stress concentration on lithium disilicate than on resin composite occlusal veneers. All lithium disilicate occlusal veneers showed radial crack failures, while resin composite occlusal veneers showed Hertzian cone cracks and radial cracks combined. CONCLUSION: Considering mechanical perspective only, RC occlusal veneers should be indicated when prosthetic preparation cusps inclinations are 30°. When 0° prosthetic preparation cusps inclinations are observed, LD occlusal veneers will behave mechanically better. When a 15° cusp inclination is preserved, both restorative materials behave similarly.


Assuntos
Cerâmica , Porcelana Dentária , Teste de Materiais , Análise do Estresse Dentário , Resinas Compostas , Desenho Assistido por Computador , Falha de Restauração Dentária , Propriedades de Superfície
8.
Clin Oral Investig ; 27(2): 787-796, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36576566

RESUMO

OBJECTIVES: Photo- and dual-polymerized resin-based luting agent was evaluated for elastic moduli effects on ultra-thin lithium disilicate (LD) glass-ceramic strengthening, structural reliability, and stress distribution. MATERIALS AND METHODS: One hundred-sixty LD discs (IPS e.max CAD, Ivoclar/Vivadent) were produced in ultra-thin thicknesses (half with 0.3 mm and the other half with 0.5 mm). The ultra-thin ceramic disks were coated with two different cement types (Variolink Veneer - V and Panavia F 2.0 - P). Two positive control groups were tested following hydrofluoric (HF) acid etching (LDt3, LDt5) and two negative control groups were tested for untreated ceramic (LD 3, LD 5). Biaxial flexural strength (BFS), characteristic strength (σ0) and Weibull modulus (m) were the response variables (n = 20) at the ceramic/resin cement interface (z = 0). Finite element analysis (FEA) was used to calculate maximum principal stress. Data were analyzed using two-way ANOVA, and Tukey's test. Scanning electron microscopy (SEM) was used to analyze the failed specimens using fractography and surface morphology. RESULTS: The BFS of LD at either thickness was not affected by cement types, as also demonstrated by FEA. Structural reliability significantly improved in the positive control group (LDt5). CONCLUSION: The cementation of ultra-thin LD with a resin-cement of varying elastic moduli did not influence BFS. LD surface modification by HF acid-etching increased the reliability. CLINICAL RELEVANCE: Ultra-thin anterior veneer designs made from lithium disilicate have been widely proposed and the apparent success of LD ultra-thin veneers was not influenced by the cement choice in the current studies albeit the elastic moduli luting agents used were of similar values.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Resistência à Flexão , Módulo de Elasticidade , Reprodutibilidade dos Testes , Teste de Materiais , Propriedades de Superfície , Porcelana Dentária/química , Cerâmica/química , Cimentos Dentários , Ácido Fluorídrico/química
9.
J Prosthet Dent ; 130(2): 241.e1-241.e8, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37328406

RESUMO

STATEMENT OF PROBLEM: New computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate glass-ceramics have been marketed. However, information concerning their biomechanical behavior is lacking. PURPOSE: The purpose of this in vitro study was to compare the fit and fatigue behavior of two recently introduced CAD-CAM lithium disilicate materials with the standard IPS e.max CAD ceramic and to investigate the effect of the thermal treatment for crystallization on crown fit. MATERIAL AND METHODS: Monolithic crowns (n=15) were milled from 3 CAD-CAM lithium disilicates: IPS e.max CAD (Ivoclar AG), Rosetta SM (Hass), and T-lithium (Shenzhen Upcera Dental Technology). Marginal and internal fit were evaluated using the replica technique before and after crystallization, and the fatigue behavior of the luted crowns was evaluated by the step-stress method. One-way ANOVA and the Tukey test were used to compare fit among the materials. Fatigue failure load was evaluated by the Kaplan-Meier and Mantel-Cox tests. The effect of crystallization on fit was evaluated with the paired t test (α=.05). RESULTS: Marginal fit was different between IPS e.max CAD (74 µm) and Rosetta SM (63 µm) (P=.02). T-lithium was similar to the other ceramics (68 µm) (P>.05). Occlusal internal space was similar among all materials (P=.69). Fatigue failure loads of Rosetta SM (1160 N) and T-lithium (1063 N) were similar to IPS e.max CAD (1082 N) (P>.05). The fatigue failure load of Rosetta SM was higher than that of T-lithium (P=.04). Crystallization reduced the axial internal space of all materials (P<.05) without significantly affecting marginal fit (P>.05). CONCLUSIONS: The fit and fatigue behavior of Rosetta SM and T-lithium were similar to that of IPS e.max CAD. Crystallization reduced the internal space of the crowns.


Assuntos
Cerâmica , Lítio , Cerâmica/química , Planejamento de Prótese Dentária/métodos , Propriedades de Superfície , Adaptação Marginal Dentária , Técnica de Moldagem Odontológica , Análise do Estresse Dentário , Teste de Materiais , Porcelana Dentária/química , Coroas , Desenho Assistido por Computador
10.
J Prosthet Dent ; 129(4): 637.e1-637.e9, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36907802

RESUMO

STATEMENT OF PROBLEM: Intraoral scanners (IOSs) are widely used for partial-coverage adhesive restorations, but data on their performance in such preparations with complex geometries are sparse. PURPOSE: The purpose of this in vitro study was to investigate whether the partial-coverage adhesive preparation design and finish line depth affect the trueness and precision of different IOSs. MATERIAL AND METHODS: Seven partial-coverage adhesive preparation designs (4 different onlays, 2 endocrowns, and 1 occlusal veneer) were tested on copies of the same tooth placed in a typodont mounted on a mannequin. Each preparation was scanned 10 times with 6 different IOSs (total 420 scans) under the same light conditions. Trueness and precision, defined according to the International Organization for Standardization (ISO) 5725-1 standard, were analyzed with a best-fit algorithm by superimposition. The obtained data were analyzed by a 2-way analysis of variance to examine the effects of partial-coverage adhesive preparation design, IOS, and their interactions (α=.05). RESULTS: Significant differences were found among different preparation designs and IOSs (P<.05) in terms of both trueness and precision. Significant differences were also found among mean positive and negative values (P<.05). Moreover, crosslinks observed between the preparation area and the adjacent teeth correlated with the finish line depth. CONCLUSIONS: Complex partial adhesive preparation designs affect the trueness and precision of IOSs, resulting in significant differences among them. Interproximal preparations should take into account the IOS's resolution and placing the finish line close to adjacent structures should be avoided.


Assuntos
Desenho Assistido por Computador , Imageamento Tridimensional , Técnica de Moldagem Odontológica , Modelos Dentários , Arco Dental
11.
J Prosthet Dent ; 129(3): 456-463, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34238537

RESUMO

STATEMENT OF PROBLEM: Various strategies have been proposed to reduce the cement space of foundation restorations for endodontically treated teeth. However, they may add more operative steps, or the dentist must keep different sizes of drills and posts in stock. A 2-piece universal adjustable post system has been developed to overcome this problem, but whether the system has acceptable fatigue survival performance is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the fatigue survival and stress distribution of endodontically treated teeth without a ferrule and restored with different glass fiber post strategies versus a recently introduced universal 2-piece fiber post system. MATERIAL AND METHODS: Bovine incisor roots were randomly assigned to 3 groups as per the post used (n=13): adapted glass fiber post with post space preparation of the same size, composite resin-custom glass fiber post (CTM), and universal 2-piece glass fiber-reinforced composite resin post (UNI). The posts were adhesively luted, the composite resin core was added, and a composite resin crown was produced with computer-aided design and computer-aided manufacturing (CAD-CAM), and then adhesively luted to each core. A fatigue test was performed with the stepwise stress method (10 000 cycles/step; 20 Hz; load=100 N to 750 N; step=50 N) until fracture, and the failure mode analyzed. The stress distribution was evaluated by finite element analysis with the maximum principal stress criteria by following the parameters of the in vitro test. The solids were considered homogeneous, linear, and isotropic, except for the glass fiber post (orthotropic), and a load of 450 N at 30 degrees was applied. The fatigue failure load and the number of cycles for failure were analyzed with Kaplan-Meier and Mantel-Cox (log rank test) (α=.05). The finite element analysis results were analyzed with colorimetric graphs. RESULTS: The highest fatigue failure load and the number of cycles for failure were found in the UNI system, whereas the lowest results were found in the CTM group. All groups exhibited repairable failures. The finite element analysis showed the lowest stress in root dentin in the UNI system. The CTM system had the largest stress regions at the dentin and dentin-core interface. CONCLUSIONS: The use of a 2-piece universal glass fiber post system resulted in more fatigue behavior compared with composite resin-custom glass fiber posts.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Animais , Bovinos , Cerâmica , Resinas Compostas , Análise do Estresse Dentário , Vidro , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Dente não Vital/terapia
12.
Clin Oral Investig ; 26(4): 3697-3706, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35028732

RESUMO

OBJECTIVES: To modify the surface of denture base material by coating it with cinnamon-laden nanofibers to reduce Candida albicans (C. albicans) adhesion and/or proliferation. MATERIALS AND METHODS: Heat-cured poly(methyl methacrylate) (PMMA) specimens were processed and coated, or not, with cinnamon-laden polymeric nanofibers (20 or 40 wt.% of cinnamon relative to the total polymer weight). Scanning electron microscopy (SEM) and Fourier-transform infrared spectroscopy (FTIR) analyses of the nanofibers were performed. Antifungal activity was assessed through agar diffusion and colony-forming unit (CFU/mL) assays. Representative SEM morphological analysis was carried out to observe the presence/absence of C. albicans on the fibers. Alamar blue assay was used to determine cell toxicity. Analysis of variance and the Tukey's test were used to analyze the data (α = 0.05). RESULTS: SEM imaging revealed nanofibers with adequate (i.e., bead-free) morphological characteristics and uniform microstructure. FTIR confirmed cinnamon incorporation. The cinnamon-laden nanofibers led to growth inhibition of C. albicans. Viable fungal counts support a significant reduction on CFU/mL also directly related to cinnamon concentration (40 wt.%: mean log 6.17 CFU/mL < 20 wt.%: mean log 7.12 CFU/mL), which agrees with the SEM images. Cinnamon-laden nanofibers at 40 wt.% led to increased cell death. CONCLUSIONS: The deposition of 20 wt.% cinnamon-laden nanofibers onto PMMA surfaces led to a significant reduction of the adhesive and/or proliferative ability of C. albicans, while maintaining epithelial cells' viability. CLINICAL RELEVANCE: The high recurrence rates of denture stomatitis are associated with patient non-adherence to treatments and contaminated prostheses use. Here, we provide the non-patients' cooperation sensible method, which possesses antifungal action, hence improving treatment effectiveness.


Assuntos
Nanofibras , Polimetil Metacrilato , Antifúngicos/farmacologia , Candida albicans , Cinnamomum zeylanicum , Bases de Dentadura/microbiologia , Humanos , Polimetil Metacrilato/química , Polimetil Metacrilato/farmacologia , Propriedades de Superfície
13.
Clin Oral Investig ; 26(3): 2513-2526, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34643807

RESUMO

OBJECTIVES: This study evaluated the effect of deep margin elevation (DME) and restorative materials (leucite-reinforced glass-ceramics [C] vs. indirect resin composite [R]) on the fatigue behavior and stress distribution of maxillary molars with 2-mm deep proximal margins restored with MOD inlay. METHODS: Fifty-two extracted human third molars were randomly assigned into four groups (n = 13): C; DME + C; R; and DME + R. Inlays were fabricated in CAD-CAM and bonded to all teeth. The fatigue behavior was assessed with the stepwise stress test (10,000 cycles/step; step = 50 N; 20 Hz; initial load = 200 N). Fatigue failure loads and the number of cycles were analyzed with 2-way ANOVA and Tukey's test (p < 0.05) and Kaplan-Meier survival plots. The stress distribution was assessed with finite element analysis. The models were considered isotropic, linear, and homogeneous, and presented bonded contacts. A tripod axial load (400 N) was applied to the occlusal surface. The stress distribution was analyzed with the maximum principal stress criterion. RESULTS: For fatigue, there was no difference for DME factor (p > 0.05). For the material factor, the load and number of cycles for failure were statistically higher in the R groups (p < 0.05). The finite element analysis showed that resin composite inlays concentrated more stress in the tooth structure, while ceramic inlays concentrated more stress in the restoration. Non-reparable failures were more frequent in the resin composite inlays groups. CONCLUSIONS: DME was not negative for fatigue and biomechanical behaviors. Resin composite inlays were more resistant to the fatigue test, although the failure mode was more aggressive. CLINICAL SIGNIFICANCE: DME does not impair mechanical behavior. Resin composite inlays failed at higher loads but with a more aggressive failure mode.


Assuntos
Porcelana Dentária , Restaurações Intracoronárias , Resinas Compostas/química , Porcelana Dentária/química , Análise do Estresse Dentário , Humanos , Teste de Materiais , Dente Molar , Estresse Mecânico
14.
Clin Oral Investig ; 26(6): 4479-4486, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35435492

RESUMO

OBJECTIVE: The aim of this study was to evaluate the effect of four different finishing procedures on the fatigue strength of a fully stabilized zirconia (5Y-FSZ) material. MATERIALS AND METHODS: Disc-shaped specimens of a 5Y-FSZ (Katana UTML, Kuraray Noritake) were made (ISO 6872-2015), grinded with 600- and 1200-grit silicon carbide paper, sintered as recommended, and randomly assigned into four groups according to the finishing technique: C (control, as-sintered), P (polished with polishing rubbers), G (glaze application - powder/liquid technique), and PG (polished with polishing rubbers + glaze application - powder/liquid). Then fatigue strength (staircase method), X-ray diffraction (XRD), and scanning electron microscopy (SEM) analyses were performed. RESULTS: The C group presented the lowest fatigue strength, while the PG group presented the highest. The P and G groups presented intermediate behavior, presenting similar statistical results. XRD showed similar crystalline phase patterns for all groups. SEM images revealed some changes in the zirconia surface, with the P group presenting some scratches on the surface, while the scratches in the PG group were filled with the glaze material. CONCLUSION: None of the techniques analyzed in this study impaired the fatigue strength of fully stabilized zirconia. Importantly, the polishing rubbers combined with glaze application (PG group) improved its fatigue strength. CLINICAL RELEVANCE: The polishing rubbers followed by glaze application improve the fatigue strength in ultra-translucent zirconia.


Assuntos
Teste de Materiais , Zircônio , Cerâmica/química , Polimento Dentário , Humanos , Microscopia Eletrônica de Varredura , Pós , Propriedades de Superfície , Zircônio/química
15.
J Esthet Restor Dent ; 34(8): 1197-1205, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35560703

RESUMO

OBJECTIVE: This investigation evaluated the effect of two sintering modes of a translucent zirconia (Y-TZP) on its surface roughness, topography, phase-transformation (t → m), translucency and biaxial flexure fatigue strength. MATERIALS AND METHODS: To do so, 50 Y-TZP discs (Ø = 15 mm; thickness = 1.2 mm; IPS e.max ZirCAD LT) were prepared and divided into two groups: Standard mode (SM) and Fast mode (FM). Staircase fatigue testing was performed (piston-on-three balls set-up, ISO 6872:2015), as well as surface roughness, profilometry, scanning electron microscopy (SEM-FEG), energy dispersive X-ray spectroscopy (EDX), phase transformation (t → m) using X-ray diffraction analysis (XRD), translucency parameter analysis (TP and TP00 ) and fractography. RESULTS: The results showed no statistical significant differences for roughness parameters (p > 0.05, SM: Ra = 0.13 ± 0.02, Rz = 1.21 ± 0.26 and RSm = 24.91 ± 2.19; FM: Ra = 0.14 ± 0.03, Rz = 1.32 ± 0.25 and RSm = 24.68 ± 2.16) or flexural fatigue strength (SM: 512 (464-560) MPa; FM: 542 (472-611) MPa) between the groups. In addition, similarity in surface morphological features (SEM and profilometry), composition and phases (EDX and XRD) was observed between the firing protocols. Fractography showed that the failure origin occurred on the tensile side. Sintering mode did not affect the TP (F = 0.001, p = 0.97) and TP00 (F = 0.12, p = 0.72). CONCLUSIONS: Therefore, the fast-sintering mode is suggested as a viable alternative to the standard mode since it does not influence the evaluated surface morphology, microstructure, fatigue strength and translucency of a translucent monolithic zirconia. CLINICAL SIGNIFICANCE: The fast sintering mode is a viable alternative for zirconia without compromising its topography, microstructure, mechanical performance or translucency.


Assuntos
Cerâmica , Ítrio , Ítrio/química , Cerâmica/química , Teste de Materiais , Propriedades de Superfície , Zircônio/química , Materiais Dentários/química
16.
J Prosthet Dent ; 128(3): 496.e1-496.e8, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35985853

RESUMO

STATEMENT OF PROBLEM: Information regarding the masking ability of ceramic crowns over different implant abutment materials is scarce. PURPOSE: The purpose of this in vitro study was to evaluate the masking ability of different monolithic or bilayer ceramic materials with different thicknesses over substrates indicated for implant restorations by using opaque and translucent evaluation pastes. MATERIAL AND METHODS: Disk-shaped specimens, shade A1 (VITA Classic; Ø10×1.5 to 2.5 mm), of different ceramics (a bilayer system [yttria-stabilized zirconia infrastructure+porcelain veneer: Zir+Pc] and monolithic systems [lithium disilicate under low, medium, or high translucency: LtLD, MtLD, or HtLD, respectively, and a high-translucent yttria-stabilized zirconia: HtZir]) were made (n=4). The color difference (ΔE00) was assessed by using the CIEDE2000 formula and considering the different ceramic systems over 5 implant abutment materials (A1 shade Zir [Zir A1]; white Zir [White Zir]; A1 low-translucency lithium disilicate [LD]; polyetheretherketone [PEEK]; and titanium [Ti]) when using 2 different evaluation pastes (translucent or opaque). The control comparison was the restorative material positioned over the Zir A1 substrate with a translucent evaluation paste. Statistical analysis was made by using a 2-way ANOVA and Tukey post hoc tests (α=.05) for ΔE00 data considering the restorative material and luting agent factors as their association. Additionally, ΔE00 data were qualitatively analyzed considering the acceptability and perceptibility thresholds. The translucency parameter (TP00) of each restorative material was evaluated, and data were submitted to 1-way ANOVA and Tukey post hoc tests (α=.05). RESULTS: The most predictable masking ability was seen with Zir+Pc regardless of the evaluation paste used. Nevertheless, under 1.5-mm thickness, Zir+Pc did not adequately mask Ti (ΔE00>1.77). Most monolithic ceramics did not mask discolored substrates (PEEK or Ti, ΔE00>1.77). The exception was HtZir, which presented acceptable masking ability over PEEK at 2.5-mm thickness with both evaluation pastes (ΔE00<1.77). Regardless of the restorative material thickness, Zir+Pc showed the lowest (P<.05) TP00 values (TP00=3.45 at 1.5-mm thickness; TP00=2.00 at 2.5-mm thickness), and HtLD presented the highest (P<.05, TP00=23.50 at 1.5-mm thickness; TP00=13.36 at 2.5-mm thickness). HtZir showed similar TP00 to MtLD at 1.5-mm thickness and similar TP00 to Zir+Pc when used at 2.5-mm thickness (P>.05). CONCLUSIONS: Monolithic ceramics should be used with caution over discolored implant abutments. Bilayer systems (Zir+Pc) were the most predictable approach to adequately masking discolored substrates such as PEEK or Ti. An increased restoration thickness provided higher masking ability for all restorative materials tested.


Assuntos
Implantes Dentários , Porcelana Dentária , Benzofenonas , Cerâmica/uso terapêutico , Cor , Coroas , Cimentos Dentários , Materiais Dentários , Teste de Materiais , Polímeros , Propriedades de Superfície , Titânio , Ítrio , Zircônio
17.
J Prosthet Dent ; 128(6): 1335.e1-1335.e8, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36404161

RESUMO

STATEMENT OF PROBLEM: Zirconia has been reported to be suitable for multiunit monolithic restorations. However, as the connector region is the weakest part of the system, studies are needed to determine the optimal connector geometry. PURPOSE: The purpose of this in vitro study was to evaluate the load-bearing capacity under fatigue of implant-supported fixed partial prostheses made of monolithic zirconia with different connector cross-sectional geometries. MATERIAL AND METHODS: Three-unit monolithic fixed partial prostheses (from mandibular second premolar to the second molar) were fabricated in zirconia (Zenostar T) by computer-aided design and computer-aided manufacture (CAD-CAM). Different connector cross-sectional geometries, with an area of 9 mm2, were tested (n=10): round, square with rounded angles, or trapezoid with rounded angles. The prostheses were screwed over 2 implants and inserted into acrylic resin bases. The specimens were submitted to a mechanical fatigue test until failure, with load applied to the pontic using the stepwise stress methodology (initial load of 100 N for 5000 cycles, followed by an increase to 200 N for 20 000 cycles, with a subsequent increase of 50 N each step). For data analysis, fatigue failure load (FFL) and cycles for fatigue failure (CFF) were recorded. Failed structures were analyzed by fractography. The Kaplan-Meier test followed by a log-rank Mantel-Cox post hoc test was used to analyze FFL and CFF (α=.05). Weibull analysis was also performed. RESULTS: The round (1065 N) and trapezoid (1010 N) groups presented higher FFL values than the square one (870 N) (P≤.05). For CFF, the round connector (358 777) was better than the square (280 310) (P=.006), and the trapezoid (337 773) was statistically similar to both (P>.05). No difference among groups was observed in Weibull modulus either for CFF or FFL data. All failures were catastrophic, originating at the base of the connector and propagating toward the occlusal surface of the pontic (region under loading). CONCLUSIONS: The connector cross-sectional geometry significantly influenced the mechanical fatigue performance of implant-supported fixed partial prostheses made of monolithic zirconia.


Assuntos
Cerâmica , Implantes Dentários , Cerâmica/química , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Zircônio/química , Desenho Assistido por Computador , Suporte de Carga , Falha de Restauração Dentária , Porcelana Dentária/química
18.
J Esthet Restor Dent ; 33(7): 1017-1028, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34105868

RESUMO

OBJECTIVE: To evaluate the effect of surface treatments on optical, colorimetric, and surface characteristics of lithium disilicate glass-ceramic. MATERIALS AND METHODS: Specimens (n = 5, IPS e.max CAD) were randomly allocated to the following treatments: mirror-polished: SiC papers; as-cut: mimicking CAD-CAM milling; ground: 90-120 µm-grit diamond bur; ground polished: ground, finished (46-30 µm-grit diamond bur), polished (diamond cups, brush and diamond paste); ground glazed: ground, glazed; ground polished glazed: association of methods. CIELAB color coordinates were obtained by a spectrophotometer. CIEDE2000 color differences (ΔE00 ) and the translucency parameter (TP00 ) were calculated. Light transmittance was assessed with a colorimeter. Surface characteristics (topography and roughness) were analyzed. Statistical differences for each condition and outcome were detected using one-way ANOVA with Tukey's post-hoc test (α = 0.05). RESULTS: TP00 data show statistical reduction after grinding (p < 0.05), which was only restored with polishing (solely or with glazing). ΔE00 shows that grinding results in perceptible variations in color (above 0.81), which were restored after all post-processing protocols (exception to only glaze application in contact with a black background). Light transmittance data corroborated such performance. Polishing and glazing reduced roughness and improved surface topography. CONCLUSION: Grinding statistically increased roughness, reduced translucency, light transmittance through the ceramic, and resulted on color differences. On contrary, polishing (followed or not by glazing) reduced roughness and enhanced ceramic translucency and light transmittance. Glaze also reduced roughness, but it still presented reduced translucency. The positioning (facing up or down) of the ceramic treated surface influenced the considered outcomes. CLINICAL SIGNIFICANCE: Grinding with diamond burs results in a deleterious impact to the optical, colorimetric and surface characteristics of lithium disilicate ceramic. Thus, polishing (followed or not by glazing) is recommended for optical and topographical enhancements when lithium disilicate monolithic restorations require occlusal adjustments.


Assuntos
Colorimetria , Polimento Dentário , Cerâmica , Porcelana Dentária , Teste de Materiais , Propriedades de Superfície
19.
J Prosthet Dent ; 126(1): 119-127, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32636073

RESUMO

STATEMENT OF PROBLEM: Data comparing the fatigue performance of adhesively luted glass or polycrystalline ceramic systems for computer-aided design and computer-aided manufacturing (CAD-CAM) are scarce. PURPOSE: The purpose of this in vitro study was to evaluate and compare the fatigue performance of monolithic crowns manufactured from glass or polycrystalline CAD-CAM ceramic systems adhesively luted to a dentin analog. MATERIALS AND METHODS: Fifty-four pairs of standardized preparations of dentin analog (NEMA Grade G10) and simplified ceramic crowns of 1.5-mm thickness were obtained with 3 ceramic materials: lithium disilicate (LD) glass-ceramic (IPS e.max CAD); zirconia-reinforced lithium silicate (ZLS) glass-ceramic (Vita Suprinity); and translucent yttrium fully stabilized polycrystalline zirconia (Trans YZ) (Prettau Anterior). The simplified crowns (n=15) were adhesively cemented onto the preparations and subjected to step-stress fatigue test (initial load of 400 N, 20 Hz, 10 000 cycles, followed by 100-N increment steps until failure). Collected data (fatigue failure load [FFL] and cycles for failure [CFF]) were submitted to survival analysis with the Kaplan-Meier and Mantel-Cox post hoc tests (α=.05) and to Weibull analysis (Weibull modulus and its respective 95% confidence interval). Failed crowns were submitted to fractography analysis. The surface characteristics of the internal surface (roughness, fractal dimension) of additional crowns were accessed, and the occlusal cement thickness obtained in each luted system was measured. RESULTS: Trans YZ crowns presented the highest values of FFL, CFF, and survival rates, followed by ZLS and LD (mean FFL: 1740 N>1187 N>987 N; mean CFF: 149 000>92 613>73 667). Weibull modulus and cement thickness were similar for all tested materials. LD presented the roughest internal surface, followed by ZLS (mean Ra: 226 nm>169 nm>93 nm). The LD and ZLS internal surfaces also showed higher fractal dimension, pointing to a more complex surface topography (mean fractal dimension: 2.242=2.238>2.147). CONCLUSIONS: CAD-CAM monolithic crowns of Trans YZ show the best fatigue performance. In addition, ZLS crowns also showed better performance than LD crowns.


Assuntos
Cerâmica , Porcelana Dentária , Desenho Assistido por Computador , Coroas , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície
20.
J Prosthet Dent ; 121(2): 292-297, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30093126

RESUMO

STATEMENT OF PROBLEM: Studies that evaluate the survival rate and load to fracture of premolars restored with inlays produced using different methods are lacking. PURPOSE: The purpose of this in vitro study was to compare the survival rate and fracture load of premolars restored with inlays fabricated using different methods. MATERIAL AND METHODS: Thirty maxillary premolars were selected, embedded, and prepared to receive inlays fabricated using different methods (n=10): LaCom-digital scanning with Lava C.O.S. scanner (3M ESPE), followed by milling of composite resin block (Lava Ultimate; 3M ESPE) in a milling unit; CeCom-digital scanning with Cerec 3D Bluecam scanner (Dentsply Sirona), followed by milling of a Lava Ultimate block in Cerec (Dentsply Sirona); PresDis-impression with polyvinyl siloxane, inlay made using the lost wax technique, and IPS e.max Press (Ivoclar Vivadent AG) pressed ceramic (lithium disilicate). A dual-polymerizing resin cement system was used to lute the inlays. Inlays were mechanically cycled (2 Hz, 106 mechanical pulses, 80 N) after 24 hours, and the specimens were stored in distilled water at 37°C for 11 months. Then, a fatigue test was conducted using a 10-Hz frequency and 400-N load on the inner inclines of the cusps. The test was complete when the specimen fractured or when the specimen reached 1.5×106 cycles. The specimens that survived fatigue testing were submitted to a single-load fracture test in a universal testing machine and analyzed using a stereoscope for failure classification. Survival rates were estimated using the Kaplan-Meier method and log-rank test (Mantel-Cox). Fracture load data were analyzed using 1-way ANOVA (α=.05). RESULTS: No significant differences were detected among the groups for the survival rate (P=.87) or for the load to fracture (P=.78). Most failures were longitudinal, catastrophic fractures. CONCLUSIONS: Premolars restored with inlays fabricated using the tested methods had similar survival rates and loads to fracture.


Assuntos
Resinas Compostas/química , Desenho Assistido por Computador , Falha de Restauração Dentária , Restaurações Intracoronárias , Dente Pré-Molar , Técnica de Moldagem Odontológica , Porcelana Dentária/química , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA