Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Nature ; 575(7781): 169-174, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31666696

RESUMO

Two dry surfaces can instantly adhere upon contact with each other through intermolecular forces such as hydrogen bonds, electrostatic interactions and van der Waals interactions1,2. However, such instant adhesion is challenging when wet surfaces such as body tissues are involved, because water separates the molecules of the two surfaces, preventing interactions3,4. Although tissue adhesives have potential advantages over suturing or stapling5,6, existing liquid or hydrogel tissue adhesives suffer from several limitations: weak bonding, low biological compatibility, poor mechanical match with tissues, and slow adhesion formation5-13. Here we propose an alternative tissue adhesive in the form of a dry double-sided tape (DST) made from a combination of a biopolymer (gelatin or chitosan) and crosslinked poly(acrylic acid) grafted with N-hydrosuccinimide ester. The adhesion mechanism of this DST relies on the removal of interfacial water from the tissue surface, resulting in fast temporary crosslinking to the surface. Subsequent covalent crosslinking with amine groups on the tissue surface further improves the adhesion stability and strength of the DST. In vitro mouse, in vivo rat and ex vivo porcine models show that the DST can achieve strong adhesion between diverse wet dynamic tissues and engineering solids within five seconds. The DST may be useful as a tissue adhesive and sealant, and in adhering wearable and implantable devices to wet tissues.


Assuntos
Adesividade , Adesivos/química , Coração , Pulmão , Próteses e Implantes , Estômago , Molhabilidade , Resinas Acrílicas/química , Animais , Quitosana/química , Reagentes de Ligações Cruzadas/química , Dessecação , Gelatina/química , Coração/anatomia & histologia , Hidrogéis/química , Ligação de Hidrogênio , Pulmão/anatomia & histologia , Pulmão/química , Camundongos , Ratos , Eletricidade Estática , Estômago/anatomia & histologia , Estômago/química , Suínos , Fatores de Tempo , Água/análise , Água/química , Dispositivos Eletrônicos Vestíveis
2.
Nat Mater ; 20(2): 229-236, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32989277

RESUMO

Reliable functions of bioelectronic devices require conformal, stable and conductive interfaces with biological tissues. Integrating bioelectronic devices with tissues usually relies on physical attachment or surgical suturing; however, these methods face challenges such as non-conformal contact, unstable fixation, tissue damage, and/or scar formation. Here, we report an electrical bioadhesive (e-bioadhesive) interface, based on a thin layer of a graphene nanocomposite, that can provide rapid (adhesion formation within 5 s), robust (interfacial toughness >400 J m-2) and on-demand detachable integration of bioelectronic devices on diverse wet dynamic tissues. The electrical conductivity (>2.6 S m-1) of the e-bioadhesive interface further allows bidirectional bioelectronic communications. We demonstrate biocompatibility, applicability, mechanical and electrical stability, and recording and stimulation functionalities of the e-bioadhesive interface based on ex vivo porcine and in vivo rat models. These findings offer a promising strategy to improve tissue-device integration and enhance the performance of biointegrated electronic devices.


Assuntos
Adesivos , Técnicas Biossensoriais , Condutividade Elétrica , Hidrogéis , Adesivos/química , Adesivos/farmacologia , Animais , Hidrogéis/química , Hidrogéis/farmacologia , Ratos , Suínos
3.
Sci Transl Med ; 16(752): eado9003, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38896601

RESUMO

Current clinically used electronic implants, including cardiac pacing leads for epicardial monitoring and stimulation of the heart, rely on surgical suturing or direct insertion of electrodes to the heart tissue. These approaches can cause tissue trauma during the implantation and retrieval of the pacing leads, with the potential for bleeding, tissue damage, and device failure. Here, we report a bioadhesive pacing lead that can directly interface with cardiac tissue through physical and covalent interactions to support minimally invasive adhesive implantation and gentle on-demand removal of the device with a detachment solution. We developed 3D-printable bioadhesive materials for customized fabrication of the device by graft-polymerizing polyacrylic acid on hydrophilic polyurethane and mixing with poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) to obtain electrical conductivity. The bioadhesive construct exhibited mechanical properties similar to cardiac tissue and strong tissue adhesion, supporting stable electrical interfacing. Infusion of a detachment solution to cleave physical and covalent cross-links between the adhesive interface and the tissue allowed retrieval of the bioadhesive pacing leads in rat and porcine models without apparent tissue damage. Continuous and reliable cardiac monitoring and pacing of rodent and porcine hearts were demonstrated for 2 weeks with consistent capture threshold and sensing amplitude, in contrast to a commercially available alternative. Pacing and continuous telemetric monitoring were achieved in a porcine model. These findings may offer a promising platform for adhesive bioelectronic devices for cardiac monitoring and treatment.


Assuntos
Marca-Passo Artificial , Animais , Suínos , Ratos , Monitorização Fisiológica/métodos , Ratos Sprague-Dawley , Eletrodos Implantados , Adesivos , Impressão Tridimensional , Modelos Animais
4.
Adv Mater ; : e2303301, 2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37310046

RESUMO

Soft robotic technologies for therapeutic biomedical applications require conformal and atraumatic tissue coupling that is amenable to dynamic loading for effective drug delivery or tissue stimulation. This intimate and sustained contact offers vast therapeutic opportunities for localized drug release. Herein, a new class of hybrid hydrogel actuator (HHA) that facilitates enhanced drug delivery is introduced. The multi-material soft actuator can elicit a tunable mechanoresponsive release of charged drug from its alginate/acrylamide hydrogel layer with temporal control. Dosing control parameters include actuation magnitude, frequency, and duration. The actuator can safely adhere to tissue via a flexible, drug-permeable adhesive bond that can withstand dynamic device actuation. Conformal adhesion of the hybrid hydrogel actuator to tissue leads to improved mechanoresponsive spatial delivery of the drug. Future integration of this hybrid hydrogel actuator with other soft robotic assistive technologies can enable a synergistic, multi-pronged treatment approach for the treatment of disease.

5.
Nat Commun ; 13(1): 4496, 2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35922421

RESUMO

Fibrous capsule (FC) formation, secondary to the foreign body response (FBR), impedes molecular transport and is detrimental to the long-term efficacy of implantable drug delivery devices, especially when tunable, temporal control is necessary. We report the development of an implantable mechanotherapeutic drug delivery platform to mitigate and overcome this host immune response using two distinct, yet synergistic soft robotic strategies. Firstly, daily intermittent actuation (cycling at 1 Hz for 5 minutes every 12 hours) preserves long-term, rapid delivery of a model drug (insulin) over 8 weeks of implantation, by mediating local immunomodulation of the cellular FBR and inducing multiphasic temporal FC changes. Secondly, actuation-mediated rapid release of therapy can enhance mass transport and therapeutic effect with tunable, temporal control. In a step towards clinical translation, we utilise a minimally invasive percutaneous approach to implant a scaled-up device in a human cadaveric model. Our soft actuatable platform has potential clinical utility for a variety of indications where transport is affected by fibrosis, such as the management of type 1 diabetes.


Assuntos
Longevidade , Próteses e Implantes , Sistemas de Liberação de Medicamentos , Fibrose , Reação a Corpo Estranho , Humanos
6.
Nat Biomed Eng ; 5(10): 1131-1142, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34373600

RESUMO

Tissue adhesives do not normally perform well on tissues that are covered with blood or other bodily fluids. Here we report the design, adhesion mechanism and performance of a paste that haemostatically seals tissues in less than 15 s, independently of the blood-coagulation rate. With a design inspired by barnacle glue (which strongly adheres to wet and contaminated surfaces owing to adhesive proteins embedded in a lipid-rich matrix), the paste consists of a blood-repelling hydrophobic oil matrix containing embedded microparticles that covalently crosslink with tissue surfaces on the application of gentle pressure. It slowly resorbs over weeks, sustains large pressures (approximately 350 mm Hg of burst pressure in a sealed porcine aorta), makes tough (interfacial toughness of 150-300 J m-2) and strong (shear and tensile strengths of, respectively, 40-70 kPa and 30-50 kPa) interfaces with blood-covered tissues, and outperforms commercial haemostatic agents in the sealing of bleeding porcine aortas ex vivo and of bleeding heart and liver tissues in live rats and pigs. The paste may aid the treatment of severe bleeding, even in individuals with coagulopathies.


Assuntos
Hemostáticos , Thoracica , Adesivos Teciduais , Animais , Ratos , Suínos , Aderências Teciduais
7.
Sci Adv ; 7(14)2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33811080

RESUMO

Surgical repair of lumen defects is associated with periprocedural morbidity and mortality. Endovascular repair with tissue adhesives may reduce host tissue damage, but current bioadhesive designs do not support minimally invasive deployment. Voltage-activated tissue adhesives offer a new strategy for endoluminal repair. To facilitate the clinical translation of voltage-activated adhesives, an electroceutical patch (ePATCH) paired with a minimally invasive catheter with retractable electrodes (CATRE) is challenged against the repair of in vivo and ex vivo lumen defects. The ePATCH/CATRE platform demonstrates the sealing of lumen defects up to 2 millimeters in diameter on wet tissue substrates. Water-tight seals are flexible and resilient, withstanding over 20,000 physiological relevant stress/strain cycles. No disruption to electrical signals was observed when the ePATCH was electrically activated on the beating heart. The ePATCH/CATRE platform has diverse potential applications ranging from endovascular treatment of pseudo-aneurysms/fistulas to bioelectrodes toward electrophysiological mapping.

8.
Biomimetics (Basel) ; 4(1)2019 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-31105193

RESUMO

The mechanical reinforcement of the ventricular wall after a myocardial infarction has been shown to modulate and attenuate negative remodeling that can lead to heart failure. Strategies include wraps, meshes, cardiac patches, or fluid-filled bladders. Here, we review the literature describing these strategies in the two broad categories of global restraint and local reinforcement. We further subdivide the global restraint category into biventricular and univentricular support. We discuss efforts to optimize devices in each of these categories, particularly in the last five years. These include adding functionality, biomimicry, and adjustability. We also discuss computational models of these strategies, and how they can be used to predict the reduction of stresses in the heart muscle wall. We discuss the range of timing of intervention that has been reported. Finally, we give a perspective on how novel fabrication technologies, imaging techniques, and computational models could potentially enhance these therapeutic strategies.

9.
Int J Numer Method Biomed Eng ; 35(9): e3213, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31062508

RESUMO

Myocardial infarction, or heart attack, is the leading cause of mortality globally. Although the treatment of myocardial infarct has improved significantly, scar tissue that persists can often lead to increased stress and adverse remodeling of surrounding tissue and ultimately to heart failure. Intra-myocardial injection of biomaterials represents a potential treatment to attenuate remodeling, mitigate degeneration, and reverse the disease process in the tissue. In vivo experiments on animal models have shown functional benefits of this therapeutic strategy. However, a poor understanding of the optimal injection pattern, volume, and material properties has acted as a barrier to its widespread clinical adoption. In this study, we developed two quasistatic finite element simulations of the left ventricle to investigate the mechanical effect of intra-myocardial injection. The first model employed an idealized left ventricular geometry with rule-based cardiomyocyte orientation. The second model employed a subject-specific left ventricular geometry with cardiomyocyte orientation from diffusion tensor magnetic resonance imaging. Both models predicted cardiac parameters including ejection fraction, systolic wall thickening, and ventricular twist that matched experimentally reported values. All injection simulations showed cardiomyocyte stress attenuation, offering an explanation for the mechanical reinforcement benefit associated with injection. The study also enabled a comparison of injection location and the corresponding effect on cardiac performance at different stages of the cardiac cycle. While the idealized model has lower fidelity, it predicts cardiac function and differentiates the effects of injection location. Both models represent versatile in silico tools to guide optimal strategy in terms of injection number, volume, site, and material properties.


Assuntos
Insuficiência Cardíaca/terapia , Modelos Cardiovasculares , Animais , Materiais Biocompatíveis/administração & dosagem , Engenharia Biomédica , Simulação por Computador , Imagem de Tensor de Difusão , Análise de Elementos Finitos , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Hidrogéis/administração & dosagem , Imageamento Tridimensional , Injeções/métodos , Miocárdio/patologia , Miócitos Cardíacos/patologia , Remodelação Ventricular/fisiologia
10.
Adv Healthc Mater ; 8(16): e1900228, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31322319

RESUMO

Delivery of therapeutic-laden biomaterials to the epicardial surface of the heart presents a promising method of treating a variety of diseased conditions by offering targeted, localized release with limited systemic recirculation and enhanced myocardial tissue uptake. A vast range of biomaterials and therapeutic agents using this approach been investigated. However, the fundamental factors that govern transport of the drug molecules from the biomaterials to the tissue are not well understood. Here, the transport of a drug analog from a biomaterial reservoir to the epicardial surface is characterized using experimental techniques and microscale modeling. Using the experimentally determined parameters, a multiscale model of transport is developed. The model is then used to study the effect of important design parameters such as loading conditions, biomaterial geometry, and orientation relative to the cardiac fibers on drug delivery to the myocardium. The simulations highlight the significance of the cardiac fiber anisotropy as a crucial factor in governing drug distribution on the epicardial surface and limiting factor for penetration into the myocardium. The multiscale model can be useful for rapid iteration of different device concepts and for determination of designs for epicardial drug delivery that may be optimal and most promising for the ultimate therapeutic goal.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Miocárdio/metabolismo , Materiais Biocompatíveis/química , Biologia Computacional/métodos , Pericárdio/metabolismo , Tomografia Computadorizada de Emissão
11.
Sci Rep ; 8(1): 14076, 2018 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-30232391

RESUMO

Optogenetic technologies have been the subject of great excitement within the scientific community for their ability to demystify complex neurophysiological pathways in the central (CNS) and peripheral nervous systems (PNS). The excitement surrounding optogenetics has also extended to the clinic with a trial for ChR2 in the treatment of retinitis pigmentosa currently underway and additional trials anticipated for the near future. In this work, we identify the cause of loss-of-expression in response to transdermal illumination of an optogenetically active peroneal nerve following an anterior compartment (AC) injection of AAV6-hSyn-ChR2(H134R) with and without a fluorescent reporter. Using Sprague Dawley Rag2-/- rats and appropriate controls, we discover optogenetic loss-of-expression is chiefly elicited by ChR2-mediated immunogenicity in the spinal cord, resulting in both CNS motor neuron death and ipsilateral muscle atrophy in both low and high Adeno-Associated Virus (AAV) dosages. We further employ pharmacological immunosuppression using a slow-release tacrolimus pellet to demonstrate sustained transdermal optogenetic expression up to 12 weeks. These results suggest that all dosages of AAV-mediated optogenetic expression within the PNS may be unsafe. Clinical optogenetics for both PNS and CNS applications should take extreme caution when employing opsins to treat disease and may require concurrent immunosuppression. Future work in optogenetics should focus on designing opsins with lesser immunogenicity.


Assuntos
Channelrhodopsins/efeitos adversos , Proteínas de Ligação a DNA/genética , Atrofia Muscular/prevenção & controle , Proteínas Nucleares/genética , Optogenética/métodos , Nervo Fibular/metabolismo , Medula Espinal/imunologia , Tacrolimo/administração & dosagem , Animais , Sobrevivência Celular/efeitos dos fármacos , Channelrhodopsins/genética , Channelrhodopsins/imunologia , Proteínas de Ligação a DNA/metabolismo , Dependovirus/genética , Vetores Genéticos/administração & dosagem , Neurônios Motores/citologia , Neurônios Motores/efeitos dos fármacos , Atrofia Muscular/induzido quimicamente , Proteínas Nucleares/metabolismo , Nervo Fibular/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Medula Espinal/efeitos dos fármacos , Medula Espinal/metabolismo , Sinapsinas/genética , Tacrolimo/farmacologia
12.
Ann Biomed Eng ; 46(10): 1534-1547, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29766347

RESUMO

Efficient coupling of soft robotic cardiac assist devices to the external surface of the heart is crucial to augment cardiac function and represents a hurdle to translation of this technology. In this work, we compare various fixation strategies for local and global coupling of a direct cardiac compression sleeve to the heart. For basal fixation, we find that a sutured Velcro band adheres the strongest to the epicardium. Next, we demonstrate that a mesh-based sleeve coupled to the myocardium improves function in an acute porcine heart failure model. Then, we analyze the biological integration of global interface material candidates (medical mesh and silicone) in a healthy and infarcted murine model and show that a mesh interface yields superior mechanical coupling via pull-off force, histology, and microcomputed tomography. These results can inform the design of a therapeutic approach where a mesh-based soft robotic DCC is implanted, allowed to biologically integrate with the epicardium, and actuated for active assistance at a later timepoint. This strategy may result in more efficient coupling of extracardiac sleeves to heart tissue, and lead to increased augmentation of heart function in end-stage heart failure patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca/cirurgia , Coração , Procedimentos Cirúrgicos Robóticos , Animais , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Modelos Animais de Doenças , Insuficiência Cardíaca/patologia , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Suínos
13.
Nat Biomed Eng ; 2(6): 416-428, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-31011199

RESUMO

The clinical translation of regenerative therapy for the diseased heart, whether in the form of cells, macromolecules or small molecules, is hampered by several factors: the poor retention and short biological half-life of the therapeutic agent, the adverse side effects from systemic delivery, and difficulties with the administration of multiple doses. Here, we report the development and application of a therapeutic epicardial device that enables sustained and repeated administration of small molecules, macromolecules and cells directly to the epicardium via a polymer-based reservoir connected to a subcutaneous port. In a myocardial infarct rodent model, we show that repeated administration of cells over a four-week period using the epicardial reservoir provided functional benefits in ejection fraction, fractional shortening and stroke work, compared to a single injection of cells and to no treatment. The pre-clinical use of the therapeutic epicardial reservoir as a research model may enable insights into regenerative cardiac therapy, and assist the development of experimental therapies towards clinical use.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos/instrumentação , Pericárdio , Próteses e Implantes , Medicina Regenerativa/instrumentação , Animais , Células Cultivadas , Desenho de Equipamento , Feminino , Infarto do Miocárdio/terapia , Pericárdio/fisiologia , Pericárdio/cirurgia , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA