Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Oral Rehabil ; 51(9): 1712-1720, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38873694

RESUMO

OBJECTIVE: The aim of this study was to present optimized device-specific low-dose cone-beam computed tomography (CBCT) protocols with sufficient image quality for pre-surgical diagnostics and three-dimensional (3D) modelling of cleft defects. METHODS: Six paediatric skulls were acquired, and an artificial bony cleft was created. A high-resolution CBCT scan acted as a reference standard (Accuitomo 170, Morita, Kyoto, Japan) for comparing eight low-dose protocols of Newtom VGi-evo (QR Verona, Cefla, Verona, Italy), which included Eco and Regular protocols with different field of views (FOVs). Delineation of lamina dura, cementoenamel junction (CEJ), trabecular bone and bony bridge were assessed. A 3D model of the defect was also evaluated. RESULT: The dose area product of low-dose protocols ranged from 31 to 254 mGy*cm2. Despite the dose difference of up to eight times between applied protocols, trabecular bone and CEJ exhibited appropriate image quality in all scans. However, Regular small FOV protocols (5 × 5 and 8 × 5 cm2), for both lamina dura and bony bridge, demonstrated a significant improvement in image quality compared to Eco FOV counterparts. Based on 3D defect analysis, no significant difference existed between low-dose protocols and the reference standard. CONCLUSION: The findings highlight the possibility of achieving a considerable reduction (up to eight times) in the radiation dose using low-dose CBCT protocols while maintaining sufficient image quality for assessing anatomical structures and 3D modelling in cleft cases.


Assuntos
Fenda Labial , Fissura Palatina , Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional , Doses de Radiação , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Fissura Palatina/diagnóstico por imagem , Imageamento Tridimensional/métodos , Fenda Labial/diagnóstico por imagem , Criança , Crânio/diagnóstico por imagem , Masculino
2.
Support Care Cancer ; 31(2): 149, 2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36737557

RESUMO

PURPOSE: To assess radiographic presentation of anatomical structures, bony changes and soft tissue calcifications on panoramic radiographs of oncologic patients under high dose antiresorptive drug therapy (ART) before exposure to dental extraction. METHODS: Panoramic radiographs of 57 patients under ART, taken previously to tooth extraction, and 57 control patients were evaluated by two oral radiologists regarding bone pattern, anatomical structures visibility, estimation of cortical width, mandibular cortical index (MCI), and presence of soft tissue calcifications. Parameters were compared between ART and age- and gender-matched healthy control groups. Bone patterns were further assessed by regions with or without tooth extractions and according to uneventful healing or MRONJ development. All comparisons were made using chi-square test with significance level set at 5%. RESULTS: Mandible and posterior maxilla presented more sclerotic bone patterns in patients under ART, regardless of tooth extraction and MRONJ development status (p < 0.05). Heterogeneous bone pattern was identified in two regions that both were subsequently affected by MRONJ. Anatomical structure visibility and presence of soft tissue calcifications was not different among groups (p > 0.05). ART patients showed significantly more C0 (thickening) and C1 MCI (p < 0.05). CONCLUSION: Sclerotic bone pattern and thicker mandibular cortices may represent a consequence of ART rather than MRONJ specific findings. Prospective studies on larger patient samples radiographically followed-up during the ART treatment are advised, with specific attention to heterogenous trabecular bone pattern as a possible MRONJ predictor.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Humanos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/etiologia , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/tratamento farmacológico , Estudos Prospectivos , Percepção , Conservadores da Densidade Óssea/uso terapêutico
3.
Clin Oral Investig ; 26(2): 1625-1636, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34424401

RESUMO

OBJECTIVES: This study aimed to describe and compare CBCT imaging prescription in clinical practice among orthodontists from five countries in Europe and America. Additionally, it investigated factors associated with the prescribing and the use of guidelines for CBCT imaging. MATERIALS AND METHODS: A cross-sectional survey was carried out using an online questionnaire sent to all registered orthodontists in Belgium, Brazil, Canada, Romania, and the United States of America (USA). The data were analyzed by descriptive statistics, bivariate tests, and Poisson regression. RESULTS: The final sample consisted of 1284 participants. CBCT was prescribed by 84.4% of the participants for selected cases (84.9%), mainly for impacted teeth (92.4%), presurgical planning (54.1%), and root resorption (51.9%). High cost was most frequently the limiting factor for CBCT prescription (55.4%). Only 45.2% of those who were using CBCT imaging reported adhering to guidelines. CBCT imaging prescription was associated with the orthodontists' countries (p < .009, except for Belgium, p = .068), while the use of guidelines was associated with the respondents' country and additional training on CBCT imaging (p < .001). CONCLUSIONS: Orthodontists refer patients for CBCT for selected indications (impacted teeth, root resorption, presurgical planning, dentofacial deformities, as suggested by the international guidelines, and also for upper airway and temporomandibular joint evaluation). Many do not adhere to specific guidelines. There are substantial variations between the countries about the orthodontists' referral for CBCT and guideline usage, irrespective of gender. CBCT prescription may be limited by financial barriers, adhering to specific guidelines and prior CBCT training. CLINICAL RELEVANCE: CBCT prescription among orthodontists must be based on prescription criteria and current guidelines. It is advised to improve CBCT education and training to enhance CBCT selection, referral, analysis, and interpretation in orthodontic practice.


Assuntos
Ortodontia , Dente Impactado , Tomografia Computadorizada de Feixe Cônico , Estudos Transversais , Humanos , Ortodontistas , Inquéritos e Questionários , Estados Unidos
4.
Oral Dis ; 27(2): 312-319, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32623770

RESUMO

OBJECTIVE: To attempt defining differential radiographic diagnostic characteristics for osteonecrotic lesions using 2D as opposed to 3D images. MATERIALS AND METHODS: This was a cross-sectional study. Subjects presenting mandibular osteonecrotic lesions (osteomyelitis, osteoradionecrosis, and medication-related osteonecrosis of the jaws) were selected and compared to a group of age- and gender-matched controls, all having both cone-beam computed tomographic images (CBCT) and panoramic radiographs (PANO). Both imaging modalities (predictor variables) were evaluated by two radiologists that scored lesion presence, eight additional radiological features, and a composite severity index (outcome variables). For each pathologic condition, characteristic features were assessed in PANO and CBCT by the Wilcoxon signed-rank test. Regression tree analysis revealed the predictive value of PANO and CBCT (α = 5%). RESULTS: Overall, the predictive value of PANO reached 74%, while for CBCT it became 90%. Regarding the composite severity index, CBCT enabled to detect more subtle lesions. Also, CBCT imaging allowed showing more distinct radiographic diagnostic features as compared to PANO imaging, more specifically when distinguishing osteomyelitis from both other lesions. CONCLUSIONS: Cone-beam computed tomography enabled showing more differences in radiological features between distinct osteonecrosis disease entities. CBCT imaging might be a better contributor for the detection of early lesions and to monitor further pathological developments in the mandible.


Assuntos
Osteomielite , Osteonecrose , Osteorradionecrose , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico , Estudos Transversais , Humanos , Mandíbula , Osteomielite/diagnóstico por imagem , Osteonecrose/induzido quimicamente , Osteonecrose/diagnóstico por imagem , Osteorradionecrose/diagnóstico por imagem , Radiografia Panorâmica
5.
Semin Musculoskelet Radiol ; 24(5): 479-487, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33036036

RESUMO

This critical review discusses the clinical challenges for patient-specific and indication-oriented dentomaxillofacial cone beam computed tomography (CBCT). Large variations among units and protocols may lead to variable degrees of diagnostic and three-dimensional model accuracy, impacting both specific diagnostic tasks and treatment planning. Particular indications, whether diagnostic or therapeutic, may give rise to very specific challenges with regard to CBCT unit and parameter setup, considering the required image quality, segmentation accuracy, and artifact level. Considering that dental materials are in the field of view needed for diagnosis or treatment planning, artifact expression is a dominant factor in proper CBCT selection. The heterogeneity of dental CBCT units and performances may highly impact the scientific results. Thus research findings cannot be simply generalized as published evidence, and a demonstrated clinical applicability for a specific indication should not be simply extrapolated from one CBCT unit to another.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Radiografia Dentária/métodos , Doenças Estomatognáticas/diagnóstico por imagem , Artefatos , Humanos
6.
Acta Odontol Scand ; 75(8): 573-576, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28754080

RESUMO

OBJECTIVE: To evaluate the performance of conventional radiography and photostimulable phosphor (PSP) plate in the detection of simulated internal root resorption (IRR) lesions in early stages. MATERIALS AND METHODS: Twenty single-rooted teeth were X-rayed before and after having a simulated IRR early lesion. Three imaging systems were used: Kodak InSight dental film and two PSPs digital systems, Digora Optime and VistaScan. The digital images were displayed on a 20.1″ LCD monitor using the native software of each system, and the conventional radiographs were evaluated on a masked light box. Two radiologists were asked to indicate the presence or absence of IRR and, after two weeks, all images were re-evaluated. Cohen's kappa coefficient was calculated to assess intra- and interobserver agreement. The three imaging systems were compared using the Kruskal-Wallis test. RESULTS: For interexaminer agreement, overall kappa values were 0.70, 0.65 and 0.70 for conventional film, Digora Optima and VistaScan, respectively. Both the conventional and digital radiography presented low sensitivity, specificity, accuracy, positive and negative predictive values with no significant difference between imaging systems (p = .0725). CONCLUSIONS: The performance of conventional and PSP was similar in the detection of simulated IRR lesions in early stages with low accuracy.


Assuntos
Radiografia Dentária Digital/métodos , Reabsorção da Raiz/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Humanos
7.
Am J Orthod Dentofacial Orthop ; 151(6): 1073-1082, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28554453

RESUMO

INTRODUCTION: The aim of this in-vitro study was to evaluate the influence of cone-beam computed tomography scans on the diagnosis of chemically simulated external root resorption. METHODS: One hundred extracted anterior teeth were selected. Subsurface demineralization was induced on a limited area of the apical third of the root of 49 teeth. Each tooth was placed in an empty socket of a partially edentulous dry mandible. Cone-beam computed tomography images were obtained according to 3 protocols: (1) half scan, 0.40-mm voxel size; (2) full scan, 0.40-mm voxel size; and (3) full scan, 0.125-mm voxel size. Three observers evaluated the images. Sensitivity, specificity, accuracy, and area under the curve were compared with the Cochran Q and Mann-Whitney U tests. RESULTS: Protocol 3 had the highest sensitivity (81.63%), accuracy (80.67%), and area under the curve (0.807). There were statistically significant differences between protocol 3 and the other 2 protocols (P <0.001). The specificity of protocol 1 (84.97%) was greater than that of protocols 2 (69.93%) and 3 (79.74%); however, a statistically significant difference was found only between protocols 1 and 2 (P = 0.005). CONCLUSIONS: A more dedicated, high-resolution scan should be acquired when one intends to investigate the early stage of external root resorption during orthodontic treatment. However, this does not imply that all orthodontic patients should be subjected to high-dose cone-beam computed tomography scans.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Reabsorção da Raiz/diagnóstico por imagem , Humanos , Técnicas In Vitro , Interpretação de Imagem Radiográfica Assistida por Computador , Reabsorção da Raiz/diagnóstico , Sensibilidade e Especificidade , Propriedades de Superfície
8.
Braz Oral Res ; 37: e059, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37341232

RESUMO

The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.


Assuntos
Cavidade Pulpar , Tratamento do Canal Radicular , Humanos , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Dente Molar/diagnóstico por imagem , Período Pós-Operatório
9.
Braz Dent J ; 33(3): 1-7, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35766712

RESUMO

The present study aimed to compare the filled volume by gutta-percha and sealer in the apical region of the main canal and ramifications, after instrumentation at two different working lengths using nano-computed tomography (nano-CT). Twenty-two premolars with apical ramifications were selected after micro-computed tomography evaluation and were randomly divided into groups for further endodontic instrumentation at two different working lengths: G1 - Root canals shaped 1 mm short of the apical foramen (n=11), and G2 - Root canals shaped at the apical foramen (n=11). After completing root treatment, nano-CT images were acquired, and the filled volume by gutta-percha and sealer in the main canal apical 0-4 mm and 0-1 mm ranges, and apical ramifications were objectively measured by an operator specialized in both radiology and endodontics, blinded for both groups. The Mann-Whitney test was applied to compare both groups regarding the filling of the main canal apical ranges and apical ramifications with a significance level of 5% (α ≤ 0.05). It was observed that root canals shaped at the apical foramen had a larger volume of the main canal filled than root canals shaped 1 mm short of the apical foramen, at both apical ranges (0-4 and 0-1 mm) (p<0.05). Regarding the filling of the apical ramifications, there was no significant difference between groups (p>0.05). In conclusion, the root canals shaped at apical foramen exhibited increased filling volume of the main canal in the apical region. However, neither of both working lengths influenced filling of the apical ramifications.


Assuntos
Guta-Percha , Materiais Restauradores do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular/métodos , Microtomografia por Raio-X
10.
Dentomaxillofac Radiol ; 50(4): 20200367, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33555198

RESUMO

OBJECTIVE: This article aims to appraise how scientific evidence related to CBCT has changed over the years, based on levels of evidence and diagnostic efficacy. METHODS: A general search strategy was used in different databases (Pubmed, Embase, and Web of Science) to identify systematic reviews (SRs) on CBCT until November of 2020. The SRs included were divided according to different specialties of dentistry. A critical review of the articles was made, describing the level of evidence and efficacy. RESULTS: In total, 75 articles were selected. There was an increase in the number of SRs on CBCT from 2014 onwards, as 83% of the SRs on this topic were published after 2013, and 72% between 2016 and to date. Twenty SRs (27%) performed meta-analysis. Only 28% of the SRs provided a detailed description of CBCT protocols. According to SR evidence, almost all specialties of dentistry have advanced concomitantly with the introduction of CBCT. The majority of SRs were related to clinical applications (level 2 of efficacy), followed by technical parameters (level 1 of efficacy). Only some CBCT models were mentioned in the SRs selected. CONCLUSION: Over the course of 20 years, SRs related to CBCT applications for a broad range of dental specialties have been published, with the vast majority of studies at levels 1 and 2 of diagnostic efficacy. Not all CBCT models available on the market have been scientifically validated. At all times, one should remain cautious as such not to simply extrapolate in vitro results to the clinical setting. Also, considering the wide variety of CBCT devices and protocols, reported results should not be overstated or generalized, as outcomes often refer to specific CBCT devices and protocols.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico , Humanos
11.
Artigo em Inglês | MEDLINE | ID: mdl-33495123

RESUMO

OBJECTIVE: The objectives of this study were to assess observers' preference for standard screens (SSs) or medical displays (MDs) in visualizing difficult-to-diagnose radiographic dental abnormalities and their preference for dental filter tools when utilized with MD systems. STUDY DESIGN: A retrospective data set of 60 in vivo radiographs consisting of intraoral (n = 20), panoramic (n = 20), and cone beam computed tomography (n = 20) images was created. Three image display monitors, including an SS, an MD, and an MD with 3 dental filter configurations (bone-low density enhancement filter, tooth-high density enhancement filter, and a combined filter representing regular MD), were utilized to assess 4 observers' monitor preferences in detecting radiographically subtle dental abnormalities. The data were analyzed by using binomial distribution. A P value ≤.05 was considered statistically significant. RESULTS: Although observers expressed preference for MD for visualizing some abnormalities when examining intraoral and panoramic radiographs, MD was not preferred for detection of any abnormalities with cone beam computed tomography. There were no significant differences in preference for SS or MD overall (P ≥ .2024). Observers expressed significant preference for the filters in visualizing all but 2 abnormalities (P ≤ .0252). CONCLUSIONS: The use of MD monitors enabled with dental filter tools may be preferred for visualizing certain subtle abnormalities.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiografia Dentária Digital , Humanos , Intensificação de Imagem Radiográfica , Radiografia Panorâmica , Estudos Retrospectivos
12.
Am J Orthod Dentofacial Orthop ; 138(2): 133.e1-7; discussion 133-5, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20691344

RESUMO

INTRODUCTION: The aim of this study was to compare the presence of alveolar defects (dehiscence and fenestration) in patients with Class I and Class II Division 1 malocclusions and different facial types. METHODS: Seventy-nine Class I and 80 Class II patients with no previous orthodontic treatment were evaluated using cone-beam computed tomography. The sample included 4319 teeth. All teeth were analyzed by 2 examiners who evaluated sectional images in axial and cross-sectional views to check for the presence or absence of dehiscence and fenestration on the buccal and lingual surfaces. RESULTS: Dehiscence was associated with 51.09% of all teeth, and fenestration with 36.51%. The Class I malocclusion patients had a greater prevalence of dehiscence: 35% higher than those with Class II Division 1 malocclusion (P <0.01). There was no statistically significant difference between the facial types. CONCLUSIONS: Alveolar defects are a common finding before orthodontic treatment, especially in Class I patients, but they are not related to the facial types.


Assuntos
Perda do Osso Alveolar/etiologia , Processo Alveolar/patologia , Má Oclusão Classe II de Angle/complicações , Má Oclusão Classe I de Angle/complicações , Técnicas de Movimentação Dentária/efeitos adversos , Adulto , Perda do Osso Alveolar/patologia , Remodelação Óssea , Tomografia Computadorizada de Feixe Cônico , Face/anatomia & histologia , Ossos Faciais/anatomia & histologia , Humanos , Má Oclusão Classe I de Angle/diagnóstico por imagem , Má Oclusão Classe I de Angle/terapia , Má Oclusão Classe II de Angle/diagnóstico por imagem , Má Oclusão Classe II de Angle/terapia , Mandíbula , Maxila , Adulto Jovem
13.
Proteomics Clin Appl ; 14(3): e1900040, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31950592

RESUMO

The increasing storage of information, data, and forms of knowledge has led to the development of new technologies that can help to accomplish complex tasks in different areas, such as in dentistry. In this context, the role of computational methods, such as radiomics and Artificial Intelligence (AI) applications, has been progressing remarkably for dentomaxillofacial radiology (DMFR). These tools bring new perspectives for diagnosis, classification, and prediction of oral diseases, treatment planning, and for the evaluation and prediction of outcomes, minimizing the possibilities of human errors. A comprehensive review of the state-of-the-art of using radiomics and machine learning (ML) for imaging in oral healthcare is presented in this paper. Although the number of published studies is still relatively low, the preliminary results are very promising and in a near future, an augmented dentomaxillofacial radiology (ADMFR) will combine the use of radiomics-based and AI-based analyses with the radiologist's evaluation. In addition to the opportunities and possibilities, some challenges and limitations have also been discussed for further investigations.


Assuntos
Atenção à Saúde/métodos , Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Saúde Bucal , Humanos
14.
Dentomaxillofac Radiol ; 49(5): 20190385, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32155087

RESUMO

OBJECTIVES: To create a new phantom design to evaluate the real impact of artefacts caused by titanium on bone structures in cone beam CT images considering different positions and quantity of metals in the dental arch, with and without metal artefact reduction (MAR). METHODS: A three cylindrical polymethyl methacrylate (PMMA) plate phantom was designed containing eight perforations arranged to simulate the lower dental arch in the intermediate plate. Three titanium cylinders were positioned in different locations and quantities to test different clinical conditions and to quantify the impact of the metal artefact around five bone cylinders. Scans were carried out in seven different protocols (Control, A-F) in two cone beam CT devices (OP300 Maxio and Picasso Trio). Eight regions of interest around each cortical and trabecular bone were used to measure the grey value standard deviation corresponding the artefact expression in the Image J software. Both the artefact expression and the MAR effect were assessed using the Wilcoxon, Friedman (Dunn) and Kruskal-Wallis tests (significance level of 5%). RESULTS: For both devices, MAR was statistically efficient only for the protocols E, and F. Protocol F (three metals on the adjacent area of the analysis region) showed higher artefact expression when compared to the others. CONCLUSION: In conclusion, the new phantom design allowed the quantification of the metal artefact expression caused by titanium. The metal artefact expression is higher when more metal objects are positioned in the adjacent bone structures. MAR may not be effective to reduce artefact expression on the adjacencies of those objects for the devices studied.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico , Arco Dental , Metais , Imagens de Fantasmas
15.
Dentomaxillofac Radiol ; 49(8): 20200145, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32501720

RESUMO

OBJECTIVES: The aim of this study was to evaluate and summarise features of currently and formerly available cone beam CT (CBCT) devices from 1996 to 2019. Additionally, a recommendation for standardised reporting of CBCT characteristics was provided. METHODS AND MATERIALS: Information about the features of all available CBCT devices was obtained from the manufacturers' available data. Moreover, site visits to newly developed CBCT machines' manufacturers were performed in order to obtain relevant information. RESULTS: A total of 279 CBCT models from 47 manufacturers located in 12 countries (Brazil, China, Denmark, Finland, France, Germany, Italy, Japan, Republic of Korea, Slovakia, Thailand, and USA) could be listed. Overall, wide variations in CBCT features and technical specifications were identified. CONCLUSIONS: CBCT in dentomaxillofacial radiology is a generic term applicable to a broad range of CBCT machines and features. Experimental outcomes and literature statements regarding radiation doses, imaging performance and diagnostic applicability of dental CBCT cannot be simply transferred from one CBCT model to another considering a wide variation in technical characteristics and clinical diagnostic performance. The information tabulated in the present study will be later provided on the International Association of DentoMaxilloFacial Radiology website (www.iadmfr.one).


Assuntos
Tomografia Computadorizada de Feixe Cônico , Brasil , China , França , Japão , República da Coreia
16.
Dentomaxillofac Radiol ; 48(1): 20180072, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30004256

RESUMO

OBJECTIVES: To evaluate different materials in simulating soft tissues and to analyze the influence of these materials on the mean (MPIV) and standard deviation of pixel intensity values comparing them to a gold-standard in CBCT images. METHODS: Images of three piglet heads with their soft tissues intact (gold-standard) and different simulant materials were acquired: ice, modelling wax, and ballistic gelatin, with the same thickness of the original soft tissues. The pixel intensities were measured in dental, bone and soft tissues regions, in the mandible and maxilla, for all the groups. Analysis of variance, Dunnet's, Pearson's and linear regression tests were performed. RESULTS: The simulators did not significantly change the MPIV of teeth in comparison with the gold-standard (p = 0.1017). Only ice (p = 0.0156) affected the MPIV of bone. Wax (p = 0.001) and ice (p = 0.0076), but not ballistic gelatin (p = 0.5814), altered the MPIV of soft tissue regions. When assessing the influence of the location (mandible or maxilla) among the simulants, the differences were significant only for the soft tissue regions. Standard deviation was not influenced by simulants (p > 0.05), but ballistic gelatin presented the lower variability. CONCLUSIONS: The ballistic gelatin was the best soft tissue simulant since it had the lowest influence on the pixel intensity values for all regions.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Maxila , Gelatina , Humanos , Mandíbula/diagnóstico por imagem , Maxila/diagnóstico por imagem
17.
Artigo em Inglês | MEDLINE | ID: mdl-31072782

RESUMO

OBJECTIVES: The aim of this study was to compare the performance of panoramic radiography (PAN), extraoral bitewing radiography (EBW), and cone beam computed tomography (CBCT) in the assessment of mandibular third molars. STUDY DESIGN: PAN and EBW were obtained to visualize 34 third molars. The teeth were evaluated by using PAN and EBW according to their positions, the presence of radiographic signs of proximity of the roots to the mandibular canal, the relationship of the roots to the canal, and the relationship of the second and third molars. Third molar position and root relationship with the canal were also assessed with CBCT. RESULTS: PAN and EBW showed significantly closer relationships compared with CBCT between the tooth and the mandibular canal (P ≤ .002). With regard to all other parameters, no differences were seen between PAN and EBW (P ≥ .072), although EBW, in comparison with PAN, showed a decreased overlap between the proximal surfaces of the second and third molars and a greater trend toward approximating root apices and the canal. CONCLUSIONS: In comparison with PAN, EBW showed a tendency to project the roots closer to the mandibular canal, but there was a decrease in the proximal surfaces overlapping the second molar. The relationship between the third molar and the mandibular canal appeared closer in PAN and EBW than in CBCT.


Assuntos
Dente Serotino , Dente Impactado , Tomografia Computadorizada de Feixe Cônico , Humanos , Mandíbula , Dente Molar , Dente Serotino/diagnóstico por imagem , Radiografia Interproximal , Radiografia Panorâmica , Raiz Dentária , Dente Impactado/diagnóstico por imagem
18.
Artigo em Inglês | MEDLINE | ID: mdl-30528550

RESUMO

OBJECTIVE: The aim of this study was to assess the performance of 2 metal artifact reduction (MAR) algorithms in cone beam computed tomography (CBCT) imaging, considering different materials, metal positions, and fields of view (FOVs). STUDY DESIGN: Nine phantoms containing cylinders of amalgam, copper-aluminum (Cu-Al) alloy, and titanium were scanned by using Picasso Trio and ProMax 3D CBCT units with small and medium FOVs. Scans were made with and without MAR algorithms. The standard deviation (SD) of voxel gray values was measured in the neighborhood of the cylinders. Differences in SD were statistically evaluated for effects of MAR and the other parameters, with a significance level of 5%. RESULTS: Significant differences between images with MAR and those without MAR for both devices (P ≤ .0001) were observed. Amalgam showed the largest artifact expression, followed by Cu-Al and titanium. After correction, differences remained only in Picasso Trio images (P = .002). Considering positions, no significant difference in the performance of the MAR algorithm was observed in either device. Considering FOVs, significant differences were observed for ProMax 3D (P = .005), with less artifact expression in the medium FOV after MAR correction. CONCLUSIONS: MAR algorithms were effective for artifact reduction despite variation in performance according to device, FOV, and material properties. The position of the metal cylinder within the FOV had no significant effect.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Materiais Dentários , Algoritmos , Metais , Imagens de Fantasmas
19.
Dentomaxillofac Radiol ; 47(3): 20170285, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29161909

RESUMO

OBJECTIVES: This report aims to describe the development of age-specific phantoms for use in paediatric dentomaxillofacial radiology research. These phantoms are denoted DIMITRA paediatric skull phantoms as these have been primarily developed and validated for the DIMITRA European research project (Dentomaxillofacial paediatric imaging: an investigation towards low-dose radiation induced risks). METHODS: To create the DIMITRA paediatric phantoms, six human paediatric skulls with estimated ages ranging between 4 and 10 years- old were selected, protected with non-radiopaque tape and immersed in melted Mix-D soft tissue equivalent material, by means of a careful procedure (layer-by-layer). Mandibles were immersed separately and a Mix-D tongue model was also created. For validation purposes, the resulting paediatric phantoms were scanned using a cone-beam CT unit with different exposure parameter settings. RESULTS: Preliminary images deriving from all scans were evaluated by two dentomaxillofacial radiologists, to check for air bubbles, artefacts and inhomogeneities of the Mix-D and a potential effect on the visualization of the jaw bone. Only skulls presenting perfect alignment of Mix-D surrounding the bone surfaces with adequate and realistic soft tissue thickness density were accepted. CONCLUSIONS: The DIMITRA anthropomorphic phantoms can yield clinically equivalent images for optimization studies in dentomaxillofacial research. In addition, the layer-by-layer technique proved to be practical and reproducible, as long as recommendations are carefully followed.


Assuntos
Face/diagnóstico por imagem , Maxila/diagnóstico por imagem , Modelos Teóricos , Imagens de Fantasmas , Radiografia Dentária , Crânio/diagnóstico por imagem , Fatores Etários , Pesquisa Biomédica , Criança , Pré-Escolar , Humanos , Técnicas In Vitro , Doses de Radiação
20.
Braz Dent J ; 29(2): 150-153, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29898060

RESUMO

X-ray microtomography (microCT) is a nondestructive technique used to assess bone morphometry. For an accurate analysis, it is necessary to segment the bone tissue from the background images, avoiding under- or overestimation of the real bone volume. Thus, segmentation methods for microCT can influence the accuracy of bone morphometry analysis. The purpose of this study was to compare two different image segmentation methods available on microCT software (subjective and objective) regarding to the human bone morphometric analysis. Sixteen samples containing a fixation screws covered by 0.5-1mm of bone were scanned using the SkyScan 1173 scanner. Three examiners segmented the microCT images subjectively and recorded the threshold values. Subsequently, an objective segmentation was also done. The 3D analysis was performed for both images using the values​ previously determined in CTAn software. Five bone morphometric parameters were calculated (BV/TV, Tb.Th, Tb.N, Tb.Sp, Conn.Den) and used as dependent variables. ANOVA showed no significant differences between the methods concerning BV/TV (p=0.424), Tb.N (p=0.672), Tb.Th (p=0.183), Tb.Sp (p=0.973) and Conn.Den (p=0.204). Intra- and interobserver agreement ranged from satisfactory to excellent (0.55-1 and 0.546-0.991, respectively). Therefore, results obtained with subjective threshorlding were similar to those obtained with objective segmentation. Since objective segmentation does not have human input and it is a truly objective method, it should be the first choice in microCT studies that concern homogeneity and high resolution human bone sample.


Assuntos
Imageamento Tridimensional/métodos , Maxila/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Feminino , Humanos , Técnicas In Vitro , Masculino , Maxila/anatomia & histologia , Pessoa de Meia-Idade , Boca Edêntula/diagnóstico por imagem , Variações Dependentes do Observador , Software , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA