Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 134(17): 1293-1302, 2016 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-27777298

RESUMO

In recent decades, significant progress has been made in the diagnosis and management of congenitally corrected transposition of the great arteries (ccTGA). Nevertheless, gradual dysfunction and failure of the right ventricle (RV) in the systemic circulation remain the main contributors to mortality and disability for patients with ccTGA, especially after adolescence. Anatomic repair of ccTGA effectively resolves the problem of failure of the systemic RV and has good early and midterm results. However, this strategy is applicable primarily in infants and children up to their teens and has associated risks and limitations, and new challenges can arise in the late postoperative period. Patients with ccTGA manifesting progressive systemic RV dysfunction beyond adolescence represent the major challenge. Several palliative options such as cardiac resynchronization therapy, tricuspid valve repair or replacement, pulmonary artery banding, and implantation of an assist device into the systemic RV can be used to improve functional status and to delay the progression of ventricular dysfunction in patients who are not suitable for anatomic correction of ccTGA. For adult patients with severe systemic RV failure, heart transplantation currently remains the only long-term lifesaving procedure, although donor organ availability remains one of the most limiting factors in this type of therapy. This review focuses on current surgical and medical strategies and interventional options for the prevention and management of systemic RV failure in adults and children with ccTGA.


Assuntos
Insuficiência Cardíaca , Ventrículos do Coração/fisiopatologia , Transposição dos Grandes Vasos , Adolescente , Adulto , Terapia de Ressincronização Cardíaca , Criança , Pré-Escolar , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Lactente , Masculino , Transposição dos Grandes Vasos/fisiopatologia , Transposição dos Grandes Vasos/cirurgia , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/terapia
2.
IEEE ASME Trans Mechatron ; 21(1): 584-590, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26951754

RESUMO

This paper describes an instrument that provides solutions to two open challenges in beating-heart intracardiac surgery - providing high-fidelity imaging of tool-tissue contact and controlling tool penetration into tissue over the cardiac cycle. Tool delivery is illustrated in the context of tissue removal for which these challenges equate to visualization of the tissue as it is being removed and to control of cutting depth. Cardioscopic imaging is provided by a camera and illumination system encased in an optical window. When the optical window is pressed against tissue, it displaces the blood between the camera and tissue allowing clear visualization. Control of cutting depth is achieved via precise extension of the cutting tool from a port in the optical window. Successful tool use is demonstrated in ex vivo and in vivo experiments.

3.
IEEE Trans Robot ; 31(1): 67-84, 2015 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-26380575

RESUMO

Concentric tube robots are catheter-sized continuum robots that are well suited for minimally invasive surgery inside confined body cavities. These robots are constructed from sets of pre-curved superelastic tubes and are capable of assuming complex 3D curves. The family of 3D curves that the robot can assume depends on the number, curvatures, lengths and stiffnesses of the tubes in its tube set. The robot design problem involves solving for a tube set that will produce the family of curves necessary to perform a surgical procedure. At a minimum, these curves must enable the robot to smoothly extend into the body and to manipulate tools over the desired surgical workspace while respecting anatomical constraints. This paper introduces an optimization framework that utilizes procedureor patient-specific image-based anatomical models along with surgical workspace requirements to generate robot tube set designs. The algorithm searches for designs that minimize robot length and curvature and for which all paths required for the procedure consist of stable robot configurations. Two mechanics-based kinematic models are used. Initial designs are sought using a model assuming torsional rigidity. These designs are then refined using a torsionally-compliant model. The approach is illustrated with clinically relevant examples from neurosurgery and intracardiac surgery.

4.
Circulation ; 128(11 Suppl 1): S263-70, 2013 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-24030417

RESUMO

BACKGROUND: Mechanisms and treatments of nonischemic functional mitral regurgitation (NIMR) are not fully established, in part, because of a lack of proper large animal models. We developed a novel technique of NIMR creation in a swine model by making multiple small incisions in the mitral annulus. METHODS AND RESULTS: Ex vivo experiments using isolated swine hearts (n=10) showed a 15% increase in annular area (6.8-7.8 cm(2)) after 16 incisions were made along the posterior mitral annulus of a pressurized left ventricle. In an in vivo swine model (n=7; 46.4 ± 2.2 kg), NIMR was created by making fourteen to twenty-six 2-mm incisions in the atrial aspect of the mitral annulus using a cardioport video-assisted imaging system in the beating heart. Animals were euthanized at 4 weeks (n=4) and 6 weeks (n=3). Three-dimensional (3D) echocardiography was obtained before and immediately after NIMR creation and at euthanasia; vena contracta area, mitral annular dimension, left ventricular volume, and inter-papillary muscle distance were measured. The mitral annular incisions resulted in mild to moderate mitral regurgitation and an increased vena contracta area. NIMR creation altered mitral valve geometry by decreasing mitral annular nonplanarity and increasing annular area, primarily in the anteroposterior dimension. NIMR creation did not significantly change left ventricular volume or inter-papillary muscle distance. Longer follow-up period did not significantly affect these outcomes. CONCLUSIONS: NIMR can successfully be created in a beating heart swine model and results in dilatation and 3D changes in mitral annular geometry. This model can enhance the experimental validation of new valve repair devices and techniques.


Assuntos
Modelos Animais de Doenças , Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/cirurgia , Animais , Doença Crônica , Dilatação Patológica/patologia , Dilatação Patológica/cirurgia , Técnicas de Cultura de Órgãos , Suínos
5.
Nat Biomed Eng ; 7(2): 110-123, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36509912

RESUMO

Severe diaphragm dysfunction can lead to respiratory failure and to the need for permanent mechanical ventilation. Yet permanent tethering to a mechanical ventilator through the mouth or via tracheostomy can hinder a patient's speech, swallowing ability and mobility. Here we show, in a porcine model of varied respiratory insufficiency, that a contractile soft robotic actuator implanted above the diaphragm augments its motion during inspiration. Synchronized actuation of the diaphragm-assist implant with the native respiratory effort increased tidal volumes and maintained ventilation flow rates within the normal range. Robotic implants that intervene at the diaphragm rather than at the upper airway and that augment physiological metrics of ventilation may restore respiratory performance without sacrificing quality of life.


Assuntos
Insuficiência Respiratória , Robótica , Suínos , Animais , Qualidade de Vida , Ventiladores Mecânicos , Insuficiência Respiratória/terapia , Próteses e Implantes
6.
Sci Adv ; 9(43): eadi5559, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37878705

RESUMO

In minimally invasive endovascular procedures, surgeons rely on catheters with low dexterity and high aspect ratios to reach an anatomical target. However, the environment inside the beating heart presents a combination of challenges unique to few anatomic locations, making it difficult for interventional tools to maneuver dexterously and apply substantial forces on an intracardiac target. We demonstrate a millimeter-scale soft robotic platform that can deploy and self-stabilize at the entrance to the heart, and guide existing interventional tools toward a target site. In two exemplar intracardiac procedures within the right atrium, the robotic platform provides enough dexterity to reach multiple anatomical targets, enough stability to maintain constant contact on motile targets, and enough mechanical leverage to generate newton-level forces. Because the device addresses ongoing challenges in minimally invasive intracardiac intervention, it may enable the further development of catheter-based interventions.


Assuntos
Robótica , Catéteres , Átrios do Coração , Desenho de Equipamento
7.
Int J Rob Res ; 31(9): 1081-1093, 2012 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-23750066

RESUMO

Achieving superior outcomes through the use of robots in medical applications requires an integrated approach to the design of the robot, tooling and the procedure itself. In this paper, this approach is applied to develop a robotic technique for closing abnormal communication between the atria of the heart. The goal is to achieve the efficacy of surgical closure as performed on a stopped, open heart with the reduced risk and trauma of a beating-heart catheter-based procedure. In the proposed approach, a concentric tube robot is used to percutaneously access the right atrium and deploy a tissue approximation device. The device is constructed using a metal microelectromechanical system (MEMS) fabrication process and is designed to both fit the manipulation capabilities of the robot as well as to reproduce the beneficial features of surgical closure by suture. The effectiveness of the approach is demonstrated through ex vivo and in vivo experiments.

8.
Interact Cardiovasc Thorac Surg ; 34(1): 128-136, 2022 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-34999794

RESUMO

OBJECTIVES: We have previously shown in experimental settings that a leaflet foldoplasty device reduces redundant leaflet area to re-establish mitral valve (MV) coaptation. The current study investigates the in vivo device retention and functional durability following foldoplasty. METHODS: The prototype is of superelastic nitinol formed into a 3-dimensional shape. It is unfolded to engage a specified area of leaflet tissue and then folded to exclude this tissue from the coaptation surface. Design modifications were made and tested in benchtop studies to determine the optimal design for durable retention within the leaflet. To evaluate in vivo performance, posterior leaflet chordae were severed in Yorkshire pigs to produce complete posterior leaflet prolapse and severe mitral regurgitation. Design modifications were then used for MV repair. Five animals that underwent repair using the optimal design were observed for 2 weeks postoperative to evaluate the functional result and implant retention. RESULTS: Device position and orientation were maintained at 2 weeks while preserving the functional MV repair in all 5 animals. Coaptation height was 5.5 ± 1.5 mm, which was not significantly different from a baseline of 4.9 ± 0.8 mm. The degree of leaflet excursion was 41.0 ± 16.0 compared to a baseline of 58.7 ± 27.5. CONCLUSIONS: Device foldoplasty is a new concept for MV repair based on the reduction of redundant leaflet tissue area. This study demonstrates the feasibility of safe maintenance of this repair without early dislodgement or embolization.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Animais , Procedimentos Cirúrgicos Cardíacos/métodos , Estudos de Viabilidade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Suínos
9.
Cardiovasc Eng Technol ; 13(1): 120-128, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34263419

RESUMO

PURPOSE: In clinical practice, many patients with right heart failure (RHF) have elevated pulmonary artery pressures and increased afterload on the right ventricle (RV). In this study, we evaluated the feasibility of RV augmentation using a soft robotic right ventricular assist device (SRVAD), in cases of increased RV afterload. METHODS: In nine Yorkshire swine of 65-80 kg, a pulmonary artery band was placed to cause RHF and maintained in place to simulate an ongoing elevated afterload on the RV. The SRVAD was actuated in synchrony with the ventricle to augment native RV output for up to one hour. Hemodynamic parameters during SRVAD actuation were compared to baseline and RHF levels. RESULTS: Median RV cardiac index (CI) was 1.43 (IQR, 1.37-1.80) L/min/m2 and 1.26 (IQR 1.05-1.57) L/min/m2 at first and second baseline. Upon PA banding RV CI fell to a median of 0.79 (IQR 0.63-1.04) L/min/m2. Device actuation improved RV CI to a median of 0.87 (IQR 0.78-1.01), 0.85 (IQR 0.64-1.59) and 1.11 (IQR 0.67-1.48) L/min/m2 at 5 min (p = 0.114), 30 min (p = 0.013) and 60 (p = 0.033) minutes respectively. Statistical GEE analysis showed that lower grade of tricuspid regurgitation at time of RHF (p = 0.046), a lower diastolic pressure at RHF (p = 0.019) and lower mean arterial pressure at RHF (p = 0.024) were significantly associated with higher SRVAD effectiveness. CONCLUSIONS: Short-term augmentation of RV function using SRVAD is feasible even in cases of elevated RV afterload. Moderate or severe tricuspid regurgitation were associated with reduced device effectiveness.


Assuntos
Insuficiência Cardíaca , Robótica , Insuficiência da Valva Tricúspide , Animais , Insuficiência Cardíaca/terapia , Ventrículos do Coração/cirurgia , Humanos , Artéria Pulmonar/cirurgia , Suínos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
10.
J Heart Valve Dis ; 20(2): 184-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21560820

RESUMO

BACKGROUND AND AIM OF THE STUDY: Experimental models of tricuspid valve regurgitation (TR) are used to study novel annuloplasty techniques (including prosthetic rings), and they can also serve as physiologic models to investigate TR pathophysiology. The study aim was to develop an appropriate simple and reproducible experimental model of TR from annular dilatation. METHODS: Acute TR was successfully created through multiple small 3- to 5-mm incisions in the annulus using a custom-made optical port with an instrument shaft (the Cardioport) that accepts a standard endoscopic imaging system. The Cardioport was inserted, via a thoracotomy, through the right atrium of seven Yorkshire pigs, and directed towards the tricuspid valve annulus to create the annular incisions. Tricuspid valve anatomy and function were evaluated using 2D and 3D echocardiography. The presence and severity of TR, annulus diameter, and changes in heart rate and atrial pressures after making the annular incisions were documented. To monitor tricuspid annular dilatation and the progression of TR, follow up echocardiography and color Doppler examinations were performed at two and eight weeks postoperatively. RESULTS: The acute onset of TR was well tolerated, and there were no deaths or significant morbidity associated with the procedure. The annular diameter was increased from a preoperative mean of 23.1 +/- 1.7 mm, to 32.2 +/- 2.5 mm at two weeks postoperatively, and to 37.3 +/- 3.6 mm at eight weeks postoperatively. Overall, the TR progressed from mild (grade I) to severe (grade III) in all of the animals. CONCLUSION: This novel porcine model represents a relatively simple and a reproducible surgical technique for the creation of annular dilatation and TR, and may also serve as a chronic model of the latter condition.


Assuntos
Endoscopia , Insuficiência da Valva Tricúspide/etiologia , Valva Tricúspide/cirurgia , Gravação em Vídeo , Animais , Função Atrial , Doença Crônica , Dilatação , Modelos Animais de Doenças , Progressão da Doença , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Frequência Cardíaca , Pressão , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Suínos , Toracotomia , Fatores de Tempo , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
11.
IEEE Trans Robot ; 26(5): 888-896, 2010 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-29375279

RESUMO

The manipulation of fast moving, delicate tissues in beating heart procedures presents a considerable challenge to the surgeon. A robotic force tracking system can assist the surgeon by applying precise contact forces to the beating heart during surgical manipulation. Standard force control approaches cannot safely attain the required bandwidth for this application due to vibratory modes within the robot structure. These vibrations are a limitation even for single degree of freedom systems driving long surgical instruments. These bandwidth limitations can be overcome by incorporating feed-forward motion terms in the control law. For intracardiac procedures, the required motion estimates can be derived from 3D ultrasound imaging. Dynamic analysis shows that a force controller with feed-forward motion terms can provide safe and accurate force tracking for contact with structures within the beating heart. In vivo validation confirms that this approach confers a 50% reduction in force fluctuations when compared to a standard force controller and a 75% reduction in fluctuations when compared to manual attempts to maintain the same force.

12.
Adv Sci (Weinh) ; 8(1): 2000726, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33437567

RESUMO

Patients suffering from heart failure often require circulatory support using ventricular assist devices (VADs). However, most existing VADs provide nonpulsatile flow, involve direct contact between the blood flow and the device's lumen and moving components, and require a driveline to connect to an external power source. These design features often lead to complications such as gastrointestinal bleeding, device thrombosis, and driveline infections. Here, a concept of magnetically active cardiac patches (MACPs) that can potentially function as non-blood contacting, untethered pulsatile VADs inside a magnetic actuationsystem is reported. The MACPs, which are composed of permanent magnets and 3D-printed patches, are attached to the epicardial surfaces, thus avoiding direct contact with the blood flow. They provide powerful actuation assisting native heart pumping inside a magnetic actuation system. In ex vivo experiments on a healthy pig's heart, it is shown that the ventricular ejection fractions are as high as 37% in the left ventricle and 63% in the right ventricle. Non-blood contacting, untethered VADs can eliminate the risk of serious complications associated with existing devices, and provide an alternative solution for myocardial training and therapy for patients with heart failure.

13.
Sci Robot ; 5(38)2020 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-33022595

RESUMO

The complex motion of the beating heart is accomplished by the spatial arrangement of contracting cardiomyocytes with varying orientation across the transmural layers, which is difficult to imitate in organic or synthetic models. High-fidelity testing of intracardiac devices requires anthropomorphic, dynamic cardiac models that represent this complex motion while maintaining the intricate anatomical structures inside the heart. In this work, we introduce a biorobotic hybrid heart that preserves organic intracardiac structures and mimics cardiac motion by replicating the cardiac myofiber architecture of the left ventricle. The heart model is composed of organic endocardial tissue from a preserved explanted heart with intact intracardiac structures and an active synthetic myocardium that drives the motion of the heart. Inspired by the helical ventricular myocardial band theory, we used diffusion tensor magnetic resonance imaging and tractography of an unraveled organic myocardial band to guide the design of individual soft robotic actuators in a synthetic myocardial band. The active soft tissue mimic was adhered to the organic endocardial tissue in a helical fashion using a custom-designed adhesive to form a flexible, conformable, and watertight organosynthetic interface. The resulting biorobotic hybrid heart simulates the contractile motion of the native heart, compared with in vivo and in silico heart models. In summary, we demonstrate a unique approach fabricating a biomimetic heart model with faithful representation of cardiac motion and endocardial tissue anatomy. These innovations represent important advances toward the unmet need for a high-fidelity in vitro cardiac simulator for preclinical testing of intracardiac devices.


Assuntos
Materiais Biomiméticos , Coração Artificial , Animais , Biomimética , Simulação por Computador , Imagem de Tensor de Difusão , Análise de Elementos Finitos , Ventrículos do Coração/anatomia & histologia , Humanos , Imageamento Tridimensional , Modelos Anatômicos , Modelos Cardiovasculares , Contração Miocárdica/fisiologia , Robótica/instrumentação , Silicones , Sus scrofa , Função Ventricular
14.
JACC Basic Transl Sci ; 5(3): 229-242, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32215347

RESUMO

Left ventricular failure is strongly associated with secondary mitral valve regurgitation. Implantable soft robotic devices are an emerging technology that enables augmentation of a native function of a target tissue. We demonstrate the ability of a novel soft robotic ventricular assist device to dynamically augment left ventricular contraction, provide native pulsatile flow, simultaneously reshape the mitral valve apparatus, and eliminate the associated regurgitation in an Short-term large animal model of acute left ventricular systolic dysfunction.

15.
Int J Comput Assist Radiol Surg ; 14(4): 577-586, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30798510

RESUMO

PURPOSE: The goal of this study was to develop an algorithm that enhances the temporal resolution of two-dimensional color Doppler echocardiography (2D CDE) by reordering all the acquired frames and filtering out the frames corrupted by out-of-plane motion and arrhythmia. METHODS: The algorithm splits original frame sequence into the fragments based on the correlation with a reference frame. Then, the fragments are aligned temporally and merged into a resulting sequence that has higher temporal resolution. We evaluated the algorithm with 10 animal epicardial 2D CDE datasets of the right ventricle and compared it with the existing approaches in terms of resulting frame rate, image stability and execution time. RESULTS: We identified the optimal combination of alternatives for each step, which resulted in an increase in frame rate from 14 ± 0.87 to 238 ± 93 Hz. The average execution time was 7.23 ± 0.48 s in comparison with 0.009 ± 0.001 s for ECG gating and 1167.37 ± 587.85 s for flow reordering. Our approach demonstrated a significant (p < 0.01) increase in image stability compared with ECG gating and flow reordering. CONCLUSION: This work presents an offline algorithm for temporal enhancement of 2D CDE. Unlike previous frame reordering approaches, it can filter out-of-plane or corrupted frames, increasing the quality of the results, which substantially increases diagnostic value of 2D CDE. It can be used for high-frame-rate intraoperative imaging of intraventricular and valve regurgitant flows and is potentially modifiable for real-time use on ultrasound machines.


Assuntos
Algoritmos , Arritmias Cardíacas/diagnóstico , Ecocardiografia Doppler em Cores/métodos , Ventrículos do Coração/diagnóstico por imagem , Aumento da Imagem/métodos , Humanos , Reprodutibilidade dos Testes
16.
J Thorac Cardiovasc Surg ; 157(1): 126-132, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30557939

RESUMO

OBJECTIVE: Aortic valve repair is currently in transition from surgical improvisation to a reproducible operation and an option for many patients with aortic regurgitation. Our research efforts at improving reproducibility include development of methods for intraoperatively testing and visualizing the valve in its diastolic state. METHODS: We developed a device that can be intraoperatively secured in the transected aorta allowing the aortic root to be pressurized and the closed valve to be inspected endoscopically. Our device includes a chamber that can be pressurized with crystalloid solution and ports for introduction of an endoscope and measuring gauges. We show use of the device in explanted porcine hearts to visualize the aortic valve and to measure leaflet coaptation height in normal valves and in valves that have undergone valve repair procedures. RESULTS: The procedure of introducing and securing the device in the aorta, pressurizing the valve, and endoscopically visualizing the closed valve is done in less than 1 minute. The device easily and reversibly attaches to the aortic root and allows direct inspection of the aortic valve under conditions that mimic diastole. It enables the surgeon to intraoperatively study the valve immediately before repair to determine mechanisms of incompetence and immediately after the repair to assess competence. We also show its use in measuring valve leaflet coaptation height in the diastolic state. CONCLUSIONS: This device enables more relevant prerepair valve assessment and also enables a test of postrepair valve competence under physiological pressures.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/instrumentação , Monitorização Intraoperatória/instrumentação , Animais , Valva Aórtica/patologia , Valva Aórtica/fisiologia , Insuficiência da Valva Aórtica/fisiopatologia , Anuloplastia da Valva Cardíaca/métodos , Humanos , Monitorização Intraoperatória/métodos , Suínos
17.
Eur J Cardiothorac Surg ; 53(5): 939-944, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29220425

RESUMO

OBJECTIVES: During mitral valve repair using the foldoplasty technique, correct judgement of the necessary dimensions and orientation of the leaflet fold is a critical but challenging step that can affect the chances of successful repair. In this study, we investigated whether a leaflet plication clip can be used to guide suture foldoplasty for posterior leaflet prolapse of the mitral valve. METHODS: Complete posterior leaflet prolapse was created in both in vivo and ex vivo pig hearts by severing the chordae supporting the middle scallop. A plication clip was applied to perform leaflet foldoplasty. Sutures were then placed using the clip as a template and the clip was removed. Leaflet width after flail creation, clip application and suture placement was determined in an ex vivo test. In vivo repair and evaluation was then performed in 7 pigs to determine the repair efficacy under normal physiological loading, at 1 and 6 h after recovery from cardiopulmonary bypass. RESULTS: Leaflet width after suture placement was comparable to the clip alone (7.0 ± 1.4 vs 9.0 ± 1.6) and both were significantly less than the flail width 15.7± 2.5 mm. In vivo, average coaptation height following repair was restored to 4.7 ± 1.4 mm and 4.2 ± 1.3 mm at 1 and 6 h, respectively, after recovery compared with the baseline height of 5.5 ± 0.9 mm. Mitral regurgitation was reduced from moderate-severe to mild or less, and addition of a De-Vega annuloplasty in the last 3 animals abolished residual leaks to trivial or none. CONCLUSIONS: Application of the adjustable leaflet plication clip facilitated accurate determination of the correct position, width, height and orientation of the foldoplasty. Any necessary clip repositioning was made prior to the placement of sutures avoiding the need to redo the sutures. This approach could potentially help improve the ease and reproducibility of the foldoplasty repair.


Assuntos
Anuloplastia da Valva Mitral/instrumentação , Valva Mitral/cirurgia , Animais , Desenho de Equipamento , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Suínos
18.
Int J Cardiovasc Imaging ; 34(7): 1041-1055, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29428969

RESUMO

The present study aimed to present a workflow algorithm for automatic processing of 2D echocardiography images. The workflow was based on several sequential steps. For each step, we compared different approaches. Epicardial 2D echocardiography datasets were acquired during various open-chest beating-heart surgical procedures in three porcine hearts. We proposed a metric called the global index that is a weighted average of several accuracy coefficients, indices and the mean processing time. This metric allows the estimation of the speed and accuracy for processing each image. The global index ranges from 0 to 1, which facilitates comparison between different approaches. The second step involved comparison among filtering, sharpening and segmentation techniques. During the noise reduction step, we compared the median filter, total variation filter, bilateral filter, curvature flow filter, non-local means filter and mean shift filter. To clarify the endocardium borders of the right heart, we used the linear sharpen. Lastly, we applied watershed segmentation, clusterisation, region-growing, morphological segmentation, image foresting segmentation and isoline delineation. We assessed all the techniques and identified the most appropriate workflow for echocardiography image segmentation of the right heart. For successful processing and segmentation of echocardiography images with minimal error, we found that the workflow should include the total variation filter/bilateral filter, linear sharpen technique, isoline delineation/region-growing segmentation and morphological post-processing. We presented an efficient and accurate workflow for the precise diagnosis of cardiovascular diseases. We introduced the global index metric for image pre-processing and segmentation estimation.


Assuntos
Ecocardiografia/métodos , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Animais , Automação , Procedimentos Cirúrgicos Cardíacos , Cuidados Intraoperatórios , Modelos Animais , Razão Sinal-Ruído , Suínos , Fluxo de Trabalho
19.
JCI Insight ; 3(13)2018 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-29997301

RESUMO

Cytokines play an important role in dysregulated immune responses to infection, pancreatitis, ischemia/reperfusion injury, burns, hemorrhage, cardiopulmonary bypass, trauma, and many other diseases. Moreover, the imbalance between inflammatory and antiinflammatory cytokines can have deleterious effects. Here, we demonstrated highly selective blood-filtering devices - antibody-modified conduits (AMCs) - that selectively eliminate multiple specific deleterious cytokines in vitro. AMCs functionalized with antibodies against human vascular endothelial growth factor A or tumor necrosis factor α (TNF-α) selectively eliminated the target cytokines from human blood in vitro and maintained them in reduced states even in the face of ongoing infusion at supraphysiologic rates. We characterized the variables that determine AMC performance, using anti-human TNF-α AMCs to eliminate recombinant human TNF-α. Finally, we demonstrated selective cytokine elimination in vivo by filtering interleukin 1 ß from rats with lipopolysaccharide-induced hypercytokinemia.


Assuntos
Anticorpos/sangue , Anticorpos/imunologia , Citocinas/sangue , Citocinas/imunologia , Animais , Humanos , Interleucina-1beta , Lipopolissacarídeos/farmacologia , Masculino , Ratos , Ratos Sprague-Dawley , Proteínas Recombinantes , Fator de Necrose Tumoral alfa/sangue , Fator de Necrose Tumoral alfa/genética , Fator A de Crescimento do Endotélio Vascular/sangue , Fator A de Crescimento do Endotélio Vascular/genética
20.
Ann Biomed Eng ; 46(10): 1534-1547, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29766347

RESUMO

Efficient coupling of soft robotic cardiac assist devices to the external surface of the heart is crucial to augment cardiac function and represents a hurdle to translation of this technology. In this work, we compare various fixation strategies for local and global coupling of a direct cardiac compression sleeve to the heart. For basal fixation, we find that a sutured Velcro band adheres the strongest to the epicardium. Next, we demonstrate that a mesh-based sleeve coupled to the myocardium improves function in an acute porcine heart failure model. Then, we analyze the biological integration of global interface material candidates (medical mesh and silicone) in a healthy and infarcted murine model and show that a mesh interface yields superior mechanical coupling via pull-off force, histology, and microcomputed tomography. These results can inform the design of a therapeutic approach where a mesh-based soft robotic DCC is implanted, allowed to biologically integrate with the epicardium, and actuated for active assistance at a later timepoint. This strategy may result in more efficient coupling of extracardiac sleeves to heart tissue, and lead to increased augmentation of heart function in end-stage heart failure patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca/cirurgia , Coração , Procedimentos Cirúrgicos Robóticos , Animais , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Modelos Animais de Doenças , Insuficiência Cardíaca/patologia , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA