Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39400487

RESUMO

INTRODUCTION: Pulsed electric field (PEF) has emerged as a promising energy source for catheter ablation of atrial fibrillation (AF). However, data regarding the in-vivo effect of PEF energy on erythrocytes during AF ablation procedures are scarce. This study aimed to quantify the impact of PEF energy on erythrocyte damage during AF ablation by assessing specific hemolytic biomarkers. METHODS: A total of 60 patients (age: 68 years, males: 72%, serum creatinine: 91 µmol/L) with AF underwent catheter ablation of AF using PEF energy delivered by a multipolar pentaspline Farawave catheter (Farapulse, Boston Scientific, Inc.). Ablation beyond pulmonary vein isolation was performed at the operator's discretion. Peripheral venous blood was sampled for assessing the plasma levels of free hemoglobin (fHb), direct (conjugated) bilirubin, lactate dehydrogenase (LDH), and creatinine before, immediately after the ablation, and on the next day. RESULTS: Following the PEF ablation with duration of [median (interquartile range)] 75 (58, 95) min, with 74 (52, 92) applications and PVI only in 27% of patients, fHb, LDH, and direct bilirubin significantly increased, from 40 (18, 65) to 493 (327, 848) mg/L, from 3.1 (2.6, 3.6) to 6.8 (5.0, 7.9) µkat/L, and from 12 (9, 17) to 28 (16, 44) µmol/L, respectively (all p < .0001). A strong linear correlation was found between the peak fHb and the number of PEF applications (R = 0.81, p < .001). The major hemolysis (defined as fHb >500 mg/L) was predicted by the number of PEF applications with the corresponding area under the receiver operating characteristic curve of 0.934. The optimum cut-off value of >74 PEF applications predicted the major hemolysis with 89% sensitivity and 87% specificity. CONCLUSION: Catheter ablation of AF using PEF energy delivered from a pentaspline catheter is associated with significant intravascular hemolysis. More than 74 PEF applications frequently resulted in major hemolysis. However, the critical amount of PEF energy that may cause kidney injury in susceptible patients remains to be investigated.

2.
J Cardiovasc Electrophysiol ; 31(12): 3097-3103, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33107171

RESUMO

INTRODUCTION: The frequency of catheter ablation for atrial fibrillation (AF) has increased dramatically, stretching resources. Discharge on the same day as treatment may increase the efficiency and throughput. There are limited data regarding the safety of this strategy. METHODS: We performed a retrospective analysis of consecutive patients undergoing AF ablation in a tertiary center and in a district general hospital, and identified those discharged on the same day of treatment. The safety endpoint was any complication and/or presentation to hospital in the 48-h and at 30 days postdischarge. We performed an economic analysis to calculate potential cost saving. RESULTS: Among a total population of 2628 patients, we identified 727 subjects (61.1 ± 12.5 years, 69.6% male) undergoing day-case AF ablation. Cryoballoon technique was used in 79.2% of the day-cases, and 91.6% of the procedures were performed under conscious sedation. 1.8% (13) of the participants met the safety composite endpoint at 48-h, however only 0.7% (5) required at least 1 day of hospitalization. Bleeding or hematoma at the femoral access site (0.5%) and pericarditic chest pain (0.5%) were the main reasons for readmission. None experienced cardiac tamponade or other life-threatening complications in the 48-h postdischarge. Overall rate of complication and/or presentation to hospital at 30 days was 3.7%. Our day-case policy resulted in an annual cost-saving of approximately of £83 927 for our hospital. CONCLUSION: In this large multicentre cohort, same-day discharge in selected patients following AF ablation appears to be safe and cost-effective, with a very low rate of early readmission or post-discharge complication.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Assistência ao Convalescente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Análise Custo-Benefício , Feminino , Humanos , Masculino , Alta do Paciente , Estudos Retrospectivos , Resultado do Tratamento
3.
Int J Cardiol ; 413: 132333, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38972492

RESUMO

OBJECTIVE: Pregnancy can trigger maternal tachycardias, and the onset of recurrent or incessant focal atrial tachycardia (AT) can lead to tachycardia-induced cardiomyopathy. Medical interventions are commonly employed, but they carry potential fetal and maternal risks. Catheter ablation (CA), particularly with non-fluoroscopic navigation systems, may be considered as an alternative. This systematic review aims to explore the feasibility and outcomes of CA for focal AT during pregnancy. METHODS: A thorough literature search was conducted until September 30th, 2023, on PubMed, Embase, and Cochrane databases. Included articles described maternal focal ATs diagnosed through electrophysiological studies and treated with CA. Data derived from these studies were organized into tables and subsequently analyzed. RESULTS: Out of 278 papers reviewed, 15 articles involving 24 patients were retrieved. CA, utilizing radiofrequency energy achieved acute success in 95.8% of cases. Sixteen patients (66.7%) underwent complete fluoroless procedures, with two adverse events directly related to the procedure reported. Long-term follow-up revealed minimal AT recurrences, with a 0.06% arrhythmia burden in one case. CONCLUSION: Focal ATs during pregnancy can be incessant and refractory to medical intervention, precipitating an acute decline in left ventricular ejection fraction. In this setting, CA emerges as an efficacious treatment modality, particularly in cases of tachycardia-induced cardiomyopathies. Whenever feasible, it is advisable to perform these procedures with minimal or no fluoroscopy guidance. Larger studies are needed to establish the safety and the efficacy of CA for focal ATs during pregnancy, as current research consists of case reports or small case series.


Assuntos
Ablação por Cateter , Complicações Cardiovasculares na Gravidez , Taquicardia Supraventricular , Humanos , Gravidez , Ablação por Cateter/métodos , Feminino , Complicações Cardiovasculares na Gravidez/cirurgia , Complicações Cardiovasculares na Gravidez/fisiopatologia , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Resultado do Tratamento
4.
ESC Heart Fail ; 11(4): 2399-2404, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38504463

RESUMO

We report the case of a 36-year-old woman who presented to the emergency department complaining of palpitations and asthenia. Investigations showed frequent ventricular ectopy and severe left ventricular ejection fraction impairment. She was diagnosed with a peculiar condition defined multifocal ectopic premature Purkinje-related contractions syndrome, which in some cases can be associated with a dilated cardiomyopathy phenotype. Genetic testing showed a novel mutation in the SCN5A gene (c.673C > G). In the context of acute left ventricular dysfunction in a young patient, we discuss the clinical presentation of this rare condition and its clinical management, as well as its genetic substrate.


Assuntos
Mutação , Canal de Sódio Disparado por Voltagem NAV1.5 , Humanos , Feminino , Adulto , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Complexos Ventriculares Prematuros/genética , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia , DNA/genética , Ramos Subendocárdicos/fisiopatologia , Análise Mutacional de DNA , Fenótipo
5.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1700-1710, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39084744

RESUMO

BACKGROUND: Hybrid-convergent radiofrequency (RF) ablation targeting pulmonary veins (PVs) and left atrial posterior wall (LAPW) has shown better arrhythmic outcomes than an endocardial-only RF strategy, despite higher rates of complications. Comparisons with extensive pulsed field ablation (PFA) are currently lacking. OBJECTIVES: This study aimed to compare the efficacy and safety of the hybrid-convergent RF vs PFA of PVs and LAPW in long-standing persistent atrial fibrillation (LSPAF). METHODS: Ninety-three consecutive LSPAF patients, treated with 2-step hybrid-convergent RF ablation (hybrid group, n = 49) or with PFA of PVs and LAPW (PFA group, n = 44) were enrolled. Primary efficacy endpoint was defined as any atrial tachyarrhythmias (ATA) recurrence after the 3-month blanking period, over a follow-up time of 12 months. Periprocedural adverse events and late complications during follow-up were deemed primary safety outcomes. RESULTS: The hybrid and PFA groups had similar baseline characteristics; mean age was hybrid 63.8 ± 10.6 years vs PFA 66.0 ± 7.4 years; P = 0.105. PV and LAPW ablation were acutely successful in all patients. Step 1 hybrid-epicardial procedures were longer than PFA (166 [Q1-Q3: 140-205] minutes vs 107.5 [Q1-Q3: 82.5-12] minutes; P < 0.01). At 12-month follow-up, there was no difference in ATA recurrences between groups (hybrid 36.7% vs PFA 40.9%; P = 0.680; log-rank at survival analysis P = 0.539). After adjusting for confounders, a larger left atrial volume and recurrences during the blanking-period were predictors of ATA recurrences after ablation, regardless of procedural technique employed. PFA showed a better safety profile with a lower rate of major periprocedural complications compared with hybrid ablation (12% vs 0%; P = 0.028). CONCLUSIONS: Hybrid-convergent and PFA share comparable arrhythmic outcomes in LSPAF, but hybrid-convergent ablation carries higher periprocedural risks.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva , Átrios do Coração/cirurgia , Átrios do Coração/fisiopatologia
6.
JACC Clin Electrophysiol ; 10(1): 121-132, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897463

RESUMO

BACKGROUND: There is a paucity of data comparing vitamin K antagonists (VKAs) to direct oral anticoagulants (DOACs) at the time of cardiac implantable electronic device (CIED) surgery. Furthermore, the best management of DOACs (interruption vs continuation) is yet to be determined. OBJECTIVES: This study aimed to compare the incidence of device-related bleeds and thrombotic events based on anticoagulant type (DOAC vs VKA) and regimen (interrupted vs uninterrupted). METHODS: This was an observational multicenter study. We included patients on chronic oral anticoagulation undergoing CIED surgery. Patients were matched using propensity scoring. RESULTS: We included 1,975 patients (age 73.8 ± 12.4 years). Among 1,326 patients on DOAC, this was interrupted presurgery in 78.2% (n = 1,039) and continued in 21.8% (n = 287). There were 649 patients on continued VKA. The matched population included 861 patients. The rate of any major bleeding was higher with continued DOAC (5.2%) compared to interrupted DOAC (1.7%) and continued VKA (2.1%) (P = 0.03). The rate of perioperative thromboembolism was 1.4% with interrupted DOAC, whereas no thromboembolic events occurred with DOAC or VKA continuation (P = 0.04). The use of dual antiplatelet therapy, DOAC continuation, and male sex were independent predictors of major bleeding on a multivariable analysis. CONCLUSIONS: In this large real-world cohort, a continued DOAC strategy was associated with a higher bleeding risk compared to DOAC interruption or VKA continuation in patients undergoing CIED surgery. However, DOAC interruption was associated with increased thromboembolic risk. Concomitant dual antiplatelet therapy should be avoided whenever clinically possible. A bespoke approach is necessary, with a strategy of minimal DOAC interruption likely to represent the best compromise.


Assuntos
Inibidores da Agregação Plaquetária , Tromboembolia , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Anticoagulantes/efeitos adversos , Fibrinolíticos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Tromboembolia/epidemiologia , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Vitamina K , Feminino
7.
Heart Rhythm ; 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39307379

RESUMO

BACKGROUND: No data regarding subcutaneous-implantable cardioverter defibrillator (S-ICD) technology in patients actively engaging in sports activities are available. OBJECTIVE: This study aims to compare S-ICD performance between athletes and nonathletes. METHODS: The primary outcome of the study was the comparison of overall device-related complications between athletes and nonathletes. Appropriate shocks, inappropriate shocks, and individual device-related complications were secondary outcomes. RESULTS: A total of 1493 patients were extracted from the International Subcutaneous Implantable Cardioverter Defibrillator Registry (iSUSI) registry, of whom 152 (10.2%) were athletes, mostly engaging in dynamic sports (54.2%). Brugada syndrome, myocarditis, and arrhythmogenic right ventricular cardiomyopathy (ARVC) were more common in athletes (11.2% vs 3.3%, P < .001; 19.1% vs 9.0%, P < .001; 8.6% vs 2.8%, P < .001, respectively). During a median follow-up time of 25.5 (12.0-41.2) months, athletes were more likely to experience appropriate shocks (yearly rate: 7.2 [4.9-10.7] % vs 4.3 [3.6-5.1] %, P = .028), occurring more frequently during exercise (3.9% vs 0.6%, P < .001). This finding lost significance when adjusting for confounders (adjusted hazard ratio [aHR] 1.440 [0.909-2.281], P = .120). No differences were found in overall device-related complications (yearly rate: 3.3% vs 3.4%, P = .448) and inappropriate shocks (yearly rate: 5.3% vs 3.7%, P = 0.111). Myopotential oversensing (4.0% vs 1.3%, P = .011) was more common in athletes, as were lead infections (3.3% vs 0.9%, P =.008), with the latter clustering in the early postimplantation period. CONCLUSION: The S-ICD is a valid therapeutic option for preventing sudden cardiac death in athletes. Sports practice was not associated with an increased risk of complications or inappropriate shocks, although athletes are exposed to a higher risk of S-ICD infections in the early postoperative period.

8.
Front Cardiovasc Med ; 10: 1199475, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745092

RESUMO

Background: Third generation drug-eluting stents (DES) potentially offer better technical performance and reduced neointimal proliferation than previous generation DES. The XLIMIT non-inferiority trial evaluated the performance of the Xlimus (a novel sirolimus-eluting coronary stent system) in terms of endothelialization and tissue healing compared to the bioresorbable polymer Synergy DES. Methods: A total of 177 patients undergoing percutaneous coronary intervention (PCI) were randomized in a 2:1 ratio (2 Xlimus: 1 Synergy). The primary endpoints, defined as the in-stent neointimal volume weighted by the sum of the lengths of the implanted stent (ISNV) and the in-stent neointimal percent volume obstruction (%VO) were evaluated at 6-9 months by means of optical coherence tomography (OCT). Additional OCT parameters as well as clinical endpoints were also collected. Results: Most of the patients were males (77.4%), and the mean age was 64 years. One third of the population had stable angina/silent ischemia. A total of 300 stents (237 lesions) were analyzed: 198 (152 lesions) were in the Xlimus group, and 102 (85 lesions) in the Synergy group. The ISNV in the Xlimus group was 30.7 ± 24.5 mm3 while in the Synergy group it was 26.5 ± 26.7 mm3: the difference between the two means was 0.08 (-0, 04-0, 45), p = 0.018, thus meeting the non-inferiority hypothesis. The %VO was 16.3% ± 10.4% and 13.3% ± 10.8% in the Xlimus and Synergy groups, respectively: the difference between the two means was 3.0 (-0, 06-4, 2), (p = 0.01), thus meeting the non-inferiority hypothesis. No difference was found with respect to the secondary OCT endpoints as well as for clinical endpoints. Conclusions: The study results confirm that the biological interaction of the Xlimus and Synergy DES with the coronary artery is comparable, and that translates in very reassuring OCT parameters at follow-up: as such, the Xlimus is non-inferior to the Synergy. Clinical Trial Registration: ClinicalTrials.gov, identifier (NCT03745053).

9.
Front Cardiovasc Med ; 8: 750139, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35096989

RESUMO

The left atrium (LA) is emerging as a key element in the pathophysiology of several cardiac diseases due to having an active role in contrasting heart failure (HF) progression. Its morphological and functional remodeling occurs progressively according to pressure or volume overload generated by the underlying disease, and its ability of adaptation contributes to avoid pulmonary circulation congestion and to postpone HF symptoms. Moreover, early signs of LA dysfunction can anticipate and predict the clinical course of HF diseases before the symptom onset which, particularly, also applies to patients with increased risk of HF with still normal cardiac structure (stage A HF). The study of LA mechanics (chamber morphology and function) is moving from a research interest to a clinical application thanks to a great clinical, prognostic, and pathophysiological significance. This process is promoted by the technological progress of cardiac imaging which increases the availability of easy-to-use tools for clinicians and HF specialists. Two-dimensional (2D) speckle tracking echocardiography and feature tracking cardiac magnetic resonance are becoming essential for daily practice. In this context, a deep understanding of LA mechanics, its prognostic significance, and the available approaches are essential to improve clinical practice. The present review will focus on LA mechanics, discussing atrial physiology and pathophysiology of main cardiac diseases across the HF stages with specific attention to the prognostic significance. Imaging techniques for LA mechanics assessment will be discussed with an overlook on the dynamic (under stress) evaluation of the chamber.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA