Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Sensors (Basel) ; 23(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36991990

RESUMO

An enhanced MEMS capacitive sensor is developed for photoacoustic gas detection. This work attempts to address the lack of the literature regarding integrated and compact silicon-based photoacoustic gas sensors. The proposed mechanical resonator combines the advantages of silicon technology used in MEMS microphones and the high-quality factor, characteristic of quartz tuning fork (QTF). The suggested design focuses on a functional partitioning of the structure to simultaneously enhance the collection of the photoacoustic energy, overcome viscous damping, and provide high nominal capacitance. The sensor is modeled and fabricated using silicon-on-insulator (SOI) wafers. First, an electrical characterization is performed to evaluate the resonator frequency response and nominal capacitance. Then, under photoacoustic excitation and without using an acoustic cavity, the viability and the linearity of the sensor are demonstrated by performing measurements on calibrated concentrations of methane in dry nitrogen. In the first harmonic detection, the limit of detection (LOD) is 104 ppmv (for 1 s integration time), leading to a normalized noise equivalent absorption coefficient (NNEA) of 8.6 ⋅ 10-8 Wcm-1 Hz-1/2, which is better than that of bare Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS), a state-of-the-art reference to compact and selective gas sensors.

2.
Sensors (Basel) ; 23(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36991846

RESUMO

This work investigates the behavior of commercial and custom Quartz tuning forkss (QTF) under humidity variations. The QTFs were placed inside a humidity chamber and the parameters were studied with a setup to record the resonance frequency and quality factor by resonance tracking. The variations of these parameters that led to a 1% theoretical error on the Quartz Enhanced Photoacoustic Spectroscopy (QEPAS) signal were defined. At a controlled level of humidity, the commercial and custom QTFs present similar results. Therefore, commercial QTFs appear to be a very good candidates for QEPAS as they are also affordable and small. When the humidity increases from 30 to 90 %RH, the variations in the custom QTFs' parameters remain suitable, while commercial QTFs show unpredictable behavior.

3.
Opt Express ; 30(4): 5531-5539, 2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35209513

RESUMO

Benzene is a gas known to be highly pollutant for the environment, for the water and cancerogenic for humans. In this paper, we present a sensor based on Quartz Enhanced Photoacoustic Spectroscopy dedicated to benzene analysis. Exploiting the infrared emission of a 14.85 µm quantum cascade laser, the sensor is working in an off-beam configuration, allowing easy alignment and stable measurements. The technique provides a very good selectivity to the sensor and a limit of detection of 30 ppbv in 1 s, i.e. a normalized noise equivalent absorption of 1.95 × 10-8 W.cm-1.Hz-1/2. The achieved performances of the sensor have enabled measurements on several air samples of a gas station showing a non-neglectable risk in case of long exposure.

4.
Sensors (Basel) ; 21(15)2021 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-34372292

RESUMO

In Quartz-Enhanced PhotoAcoustic Spectroscopy (QEPAS) gas sensors, the acoustic wave is detected by the piezoelectric Quartz Tuning Fork (QTF). Due to its high-quality factor, the QTF can detect very low-pressure variations, but its resonance can also be affected by the environmental variations (temperature, humidity, …), which causes an unwanted signal drift. Recently, we presented the RT-QEPAS technique that consistently corrects the signal drift by continuously measuring the QTF resonance. In this article, we present an improvement of RT-QEPAS to fasten the QTF characterization time by adding a passive electronic circuit, which causes the damping of the QTF resonance. The damping circuit is optimized analytically and through SPICE simulation. The results are supported by experimental observations, showing a 70 times improvement of the relaxation times compared to the lone QTF, which opens the way to a fast and drift-free QEPAS sensor.


Assuntos
Técnicas Fotoacústicas , Quartzo , Simulação por Computador , Análise Espectral , Vibração
5.
Sensors (Basel) ; 21(4)2021 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-33669992

RESUMO

We propose a new concept of photoacoustic gas sensing based on capacitive transduction which allows full integration while conserving the required characteristics of the sensor. For the sensor's performance optimization, trial and error method is not feasible due to economic and time constrains. Therefore, we focus on a theoretical optimization of the sensor reinforced by computational methods implemented in a Python programming environment. We present an analytic model to optimize the geometry of a cantilever used as a capacitive transducer in photoacoustic spectroscopy. We describe all the physical parameters which have to be considered for this optimization (photoacoustic force, damping, mechanical susceptibility, capacitive transduction, etc.). These parameters are characterized by opposite trends. They are studied and compared to obtain geometric values for which the signal output and signal-to-noise ratio are maximized.

6.
Opt Express ; 27(5): 7435-7446, 2019 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-30876307

RESUMO

An off-beam quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor was designed for ethylene detection using a distributed-feedback quantum cascade laser (QCL) operating in the mid-infrared around 11 µm. The acoustic microresonator configuration was experimentally optimized using an original open-cell photoacoustic setup with a MEMS microphone. Correction factors based on theoretical acoustic models were introduced in order to accurately describe the response of millimeter-sized acoustic resonators. The optimized QEPAS sensor exhibited a limit of detection of 60 ppb for 60 s integration, giving a NNEA of 4.8 × 10-8 W·cm-1·Hz-0.5.

7.
Sensors (Basel) ; 19(24)2019 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-31888305

RESUMO

The quartz tuning fork (QTF) is a piezoelectric transducer with a high quality factor that was successfully employed in sensitive applications such as atomic force microscopy or Quartz-Enhanced Photo-Acoustic Spectroscopy (QEPAS). The variability of the environment (temperature, humidity) can lead to a drift of the QTF resonance. In most applications, regular QTF calibration is absolutely essential. Because the requirements vary greatly depending on the field of application, different characterization methods can be found in the literature. We present a review of these methods and compare them in terms of accuracy. Then, we further detail one technique, called Beat Frequency analysis, based on the transient response followed by heterodyning. This method proved to be fast and accurate. Further, we demonstrate the resonance tracking of the QTF while changing the temperature and the humidity. Finally, we integrate this characterization method in our Resonance Tracking (RT) QEPAS sensor and show the significant reduction of the signal drift compared to a conventional QEPAS sensor.

8.
Opt Express ; 23(15): 19118-28, 2015 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-26367575

RESUMO

We report on the growth, fabrication, experimental study and application in an absorption gas setup of distributed feed-back antimonide diode lasers with buried grating. First, half laser structures were grown by molecular beam epitaxy on GaSb substrates and stopped at the top of the waveguide. A second order Bragg grating was then defined by interferometric lithography on the top of the structure and dry etched by Reactive Ion Etching. The grating was, afterwards, buried thanks to an epitaxial regrowth of the top cladding layer. Finally, the wafer was processed using standard photolithography and wet etched into 10 µm-wide laser ridges. A single frequency laser emission around 2.3 µm was recorded, a maximum output power of 25 mW and a total continuous tuning range reaching 4.2 nm at fixed temperature. A device has been used to detect methane gas and shows strong potential for gas spectroscopy. This process was also replicated for a target of 3 µm laser emission. These devices showed an output power of 2.5 mW and a SMSR of at least 23 dB, with a 2.5 nm continuous tuning range at fixed temperature.

9.
Opt Lett ; 37(13): 2502-4, 2012 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22743435

RESUMO

A system for gas sensing based on the quartz-enhanced photoacoustic spectroscopy technique has been developed. It makes use of a quantum well distributed feedback (DFB) laser diode emitting at 3.38 µm. This laser emits near room temperature in the continuous wave regime. A spectrophone, consisting of a quartz tuning fork and two steel microresonators were used. Second derivative wavelength modulation detection is used to perform low concentration measurements. The sensitivity and the linearity of the Quartz enhanced photoacoustic spectroscopy (QEPAS) sensor were studied. A normalized noise equivalent absorption coefficient of 4.06×10(-9) cm(-1)·W/Hz(1/2) was achieved.

10.
J Breath Res ; 16(1)2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34727537

RESUMO

Introduction. Exhaled breath acetone (ExA) has been investigated as a biomarker for heart failure (HF). Yet, barriers to its use in the clinical field have not been identified. The aim of this systematic review and meta-analysis was to assess the ExA heterogeneity and factors of variability in healthy controls (HC), to identify its relations with HF diagnosis and prognostic factors and to assess its diagnosis and prognosis accuracy in HF patients.Methods. A systematic search was conducted in PUBMED and Web of Science database. All studies with HC and HF patients with a measured ExA were included and studies providing ExA's diagnosis and prognosis accuracy were identified.Results. Out of 971 identified studies, 18 studies involving 833 HC and 1009 HF patients were included in the meta-analysis. In HC, ExA showed an important heterogeneity (I2= 99%). Variability factors were fasting state, sampling type and analytical method. The mean ExA was 1.89 times higher in HF patients vs. HC (782 [531-1032] vs. 413 [347-478] ppbv;p< 0.001). One study showed excellent diagnosis accuracy, and one showed a good prognosis value. ExA correlated with New York Heart Association (NYHA) dyspnea (p< 0.001) and plasma brain natriuretic peptide (p< 0.001). Studies showed a poor definition and reporting of included subjects.Discussion. Despite the between-study heterogeneity in HC, the evidence of an excellent diagnosis and prognosis value of ExA in HF from single studies can be extended to clinical populations worldwide. Factors of variability (ExA procedure and breath sampling) could further improve the diagnosis and prognosis values of this biomarker in HF patients.


Assuntos
Acetona , Insuficiência Cardíaca , Biomarcadores , Testes Respiratórios/métodos , Insuficiência Cardíaca/diagnóstico , Humanos , Prognóstico
11.
Artigo em Inglês | MEDLINE | ID: mdl-16500141

RESUMO

A new and compact photoacoustic sensor for trace gas detection in the 2-2.5 microm atmospheric window is reported. Both the development of antimonide-based DFB lasers with singlemode emission in this spectral range and a novel design of photoacoustic cell adapted to the characteristics of these lasers are discussed. The laser fabrication was made in two steps. The structure was firstly grown by molecular beam epitaxy then a metallic DFB grating was processed. The photoacoustic cell is based on a Helmholtz resonator that was designed in order to fully benefit from the highly divergent emission of the antimonide laser. An optimized modulation scheme based on wavelength modulation of the laser source combined with second harmonic detection has been implemented for efficient suppression of wall noise. Using a 2211 nm laser, sub-ppm detection limit has been demonstrated for ammonia.


Assuntos
Gases/análise , Lasers , Análise Espectral/instrumentação , Acústica , Amônia , Luz , Fotometria , Teoria Quântica , Análise Espectral/métodos , Transdutores
12.
Spectrochim Acta A Mol Biomol Spectrosc ; 60(14): 3431-6, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15561629

RESUMO

First investigations of photoacoustic (PA) spectroscopy (PAS) of methane using an antimonide semiconductor laser are reported. The laser fabrication is made in two steps. The structure is firstly grown by molecular beam epitaxy, then a metallic distributed-feedback (DFB) grating is processed. The laser operates at 2371.6 nm in continuous wave and at room temperature. It demonstrates single-mode emission with typical tuning coefficients of 0.04 nm mA(-1) and 0.2 nm K(-1). PA detection of methane was performed by coupling this laser into a radial PA cell. A detection limit of 20 ppm has been achieved in a preliminary configuration that was not optimised for the laser characteristics.


Assuntos
Antimônio , Técnicas de Química Analítica/métodos , Lasers , Técnicas de Química Analítica/instrumentação , Análise Espectral/instrumentação , Análise Espectral/métodos , Fatores de Tempo
13.
Appl Opt ; 45(20): 4957-65, 2006 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-16807605

RESUMO

GaInAsSb/GaAlAsSb/GaSb distributed-feedback (DFB) laser diodes based on a type I active region were fabricated by molecular beam epitaxy at the Centre d'Electronique et de Micro-Optoélectronique de Montpellier (CEM2). The DFB processing was done by Nanoplus Nanosystems and Technologies GmbH. The devices work in the continuous-wave regime above room temperature around an emission wavelength of 2.3 microm with a side-mode suppression ratio greater than 25 dB and as great as 10 mW of output power. The laser devices are fully characterized in terms of optical and electrical properties. Their tuning properties made them adaptable to tunable diode laser absorption spectroscopy because they exhibit more than 220 GHz of continuous tuning by temperature or current. The direct absorption of CH4 is demonstrated to be possible with high spectral selectivity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA