RESUMO
This Letter reports on the quadratic electro-optic effect of polymers, observed in a silicon slot-waveguide at low voltages. We demonstrate that in narrow slots, the electro-optic response with respect to refractive index change is strong enough for on-chip wavelength tuning and intensity modulation using voltages as low as 1 V. A silicon slot-waveguide embedded by a nonlinear optical polymer, consisting of the dye Disperse Red 1 in poly(methyl methacrylate), serves as the phase shifter in a racetrack ring resonator. As deduced from the experimental data, the third-order susceptibility of the utilized electro-optic polymer is about 2·10-19 m2/V2. The demonstrated low-voltage operation and inherently thermal stability show the potential for silicon-organic hybrid devices using the quadratic electro-optic effect.
RESUMO
A Fabry-Perot ultrasound sensor with nonhygroscopic dielectric mirrors made out of Ta2O5 and SiO2 for use in photoacoustic tomography is described. The sensor offers flat frequency response up to 36 MHz, low noise-equivalent pressure (70 Pa), and near-omnidirectional response up to 20 MHz as well as optical transparency for near-infrared illumination. A numerical model was developed to predict its frequency response, and the results were validated experimentally. An image of the human palm was acquired to demonstrate in vivo imaging capabilities.
Assuntos
Desenho de Equipamento , Óxidos , Técnicas Fotoacústicas/instrumentação , Dióxido de Silício , Tantálio , Ultrassonografia/instrumentação , Espectroscopia Dielétrica/instrumentação , Mãos/irrigação sanguínea , Mãos/diagnóstico por imagem , HumanosRESUMO
Photoacoustic imaging through skull bone causes strong attenuation and distortion of the acoustic wavefront, which diminishes image contrast and resolution. As a result, transcranial photoacoustic measurements in humans have been challenging to demonstrate. In this study, we investigated the acoustic transmission through the human skull to design an ultrasound sensor suitable for transcranial PA imaging and sensing. We measured the frequency dependent losses of human cranial bones ex vivo, compared the performance of a range of piezoelectric and optical ultrasound sensors, and imaged skull phantoms using a PA tomograph based on a planar Fabry-Perot sensor. All transcranial photoacoustic measurements show the typical effects of frequency and thickness dependent attenuation and aberration associated with acoustic propagation through bone. The performance of plano-concave optical resonator ultrasound sensors was found to be highly suitable for transcranial photoacoustic measurements.
RESUMO
Optical-resolution photoacoustic microscopy (OR-PAM) combines high spatial resolution and strong absorption-based contrast in tissue, which has enabled structural and spectroscopic imaging of endogenous chromophores, primarily hemoglobin. Conventional piezoelectric ultrasound transducers are typically placed far away from the photoacoustic source due to their opacity, which reduces acoustic sensitivity. Optical ultrasound sensors are an alternative as their transparency allows them to be positioned close to the sample with minimal source-detector distances. In this work, a backward-mode OR-PAM system based on a planar Fabry-Pérot ultrasound sensor and coaxially aligned excitation and interrogation beams was developed. Two 3D imaging modes, using raster-scanning for enhanced image quality and continuous-scanning for fast imaging, were implemented and tested on a leaf skeleton phantom. In fast imaging mode, a scan-rate of 100,000 A-lines/s was achieved. 3D images of a zebrafish embryo were acquired in vivo in raster-scanning mode. The transparency of the FP sensor in the visible and near-infrared wavelength region makes it suitable for combined functional and molecular imaging applications using OR-PAM and multi-photon fluorescence microscopy.