Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 28(5): 7314-7322, 2020 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-32225962

RESUMO

High-harmonic generation (HHG) in crystals offers a simple, affordable and easily accessible route to carrier-envelope phase (CEP) measurements, which scales favorably towards longer wavelengths. We present measurements of HHG in ZnO using few-cycle pulses at 3.1µm. Thanks to the broad bandwidth of the driving laser pulses, spectral overlap between adjacent harmonic orders is achieved. The resulting spectral interference pattern provides access to the relative harmonic phase, and hence, the CEP.

2.
Phys Rev Lett ; 124(13): 133202, 2020 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-32302186

RESUMO

The spatially dependent phase distribution of focused few-cycle pulses, i.e., the focal phase, is much more complex than the well-known Gouy phase of monochromatic beams. As the focal phase is imprinted on the carrier-envelope phase (CEP), for accurate modeling and interpretation of CEP-dependent few-cycle laser-matter interactions, both the coupled spatially dependent phase and intensity distributions must be taken into account. In this Letter, we demonstrate the significance of the focal phase effect via comparison of measurements and simulations of CEP-dependent photoelectron spectra. Moreover, we demonstrate the impact of this effect on few-cycle light-matter interactions as a function of their nonlinear intensity dependence to answer the general question: if, when, and how much should one be concerned about the focal phase?

3.
Opt Lett ; 42(24): 5150-5153, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-29240160

RESUMO

A high-precision, single-shot, and real-time carrier-envelope phase (CEP) measurement at 1.8 µm laser wavelength based on stereographic photoelectron spectroscopy is presented. A precision of the CEP measurement of 120 mrad for each and every individual laser shot for a 1 kHz pulse train with randomly varying CEP is demonstrated. Simultaneous to the CEP measurement, the pulse lengths are characterized by evaluating the spatial asymmetry of the measured above-threshold ionization (ATI) spectra of xenon and referenced to a standard pulse-duration measurement based on frequency-resolved optical gating. The validity of the CEP measurement is confirmed by implementing phase tagging for a CEP-dependent measurement of ATI in xenon with high energy resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA