Interlayer bonding quality is the key to the stability and durability of dam concrete. In this study, interlayer splitting tensile strength, relative permeability coefficient, and electric flux of dam concrete at different temperatures were tested. The relationships between equivalent age and strength coefficient, relative permeability coefficient ratio, and electric flux ratio were established. Meanwhile, a comprehensive early-warning and control system of dam interlayer bonding quality based on the above relationships was proposed. The results showed that the interlayer mechanical properties, impermeability, and anti-chloride ion permeability of dam concrete decreased with the increase of temperature. Moreover, the equivalent age was linearly correlated with strength coefficient, relative permeability coefficient ratio, and electric flux ratio of concrete. The correlation coefficients were 0.986, 0.973, and 0.924, respectively. In addition, the interlayer bonding quality of dam concrete can be effectively controlled by the early-warning system established according to the relationship between equivalent age and interlayer properties parameters.