Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Transplant ; 25(7): e14086, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34275181

RESUMO

BACKGROUND: New drugs may further decrease the need for lung transplant (LTx) in pediatric patients with cystic fibrosis (CF), but few studies highlight pediatric non-CF LTx characteristics and outcomes. METHODS: The ISHLT registry was used to report morbidity, graft failure, and survival for primary pediatric (<18 years) LTx performed 1990-2017. Recipient/donor characteristics and long-term outcomes were analyzed for CF and non-CF recipients. Survival was assessed using Kaplan-Meier curves. RESULTS: Of 2232 primary LTx, (43% in males), 918 (41%) were performed for non-CF indications; most commonly pulmonary hypertension (43%). Non-CF patients were younger (median age 11 vs. 15, p < .001), and more frequently on inotropes and/or extracorporeal membrane oxygenation (15% vs. 2.4%, p < .001) at transplant, compared to CF recipients. In-hospital major complications more commonly affected CF LTx recipients (57% vs. 48%, p = .003), but 30-day mortality was higher in the non-CF group (9% non-CF vs. 5% CF, p < .001). One-, five-, and ten-year mortality was 18%, 50%, and 65% for CF recipients, respectively, and 21%, 45%, and 58% for non-CF recipients (p = .01 at 10 years). Five-year survival was significantly better for non-CF females versus CF females (56% vs. 48%, p = .013), but was similar between groups for males (55% vs. 54%, p = .305). While age was a late outcomes risk factor, pulmonary hypertension and later transplants eras were protective. CONCLUSIONS: Early mortality is higher and late mortality is lower in non-CF LTx. Current non-CF LTx outcomes leave room for improvement. Further study is needed to evaluate the effects of center volume and pediatric-specific experience on outcomes.


Assuntos
Fibrose Cística/mortalidade , Fibrose Cística/cirurgia , Transplante de Pulmão/mortalidade , Padrões de Prática Médica/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Feminino , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Lactente , Masculino , Sistema de Registros , Estudos Retrospectivos , Análise de Sobrevida
2.
Cardiol Young ; 29(6): 833-834, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31159905

RESUMO

We present the case of a 17-year-old boy with a cardiac venous malformation. This case highlights the diagnostic challenges of such tumours and demonstrates the potential efficacy of a watch-and-wait management approach.


Assuntos
Cardiopatias Congênitas/diagnóstico , Malformações Vasculares/diagnóstico , Veias/anormalidades , Adolescente , Diagnóstico Diferencial , Ecocardiografia Transesofagiana/métodos , Ventrículos do Coração , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Veias/diagnóstico por imagem
3.
Pediatr Cardiol ; 39(6): 1242-1248, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29774392

RESUMO

Destination ventricular assist device therapy (DT-VAD) is well accepted in select adults with medically refractory heart failure (HF) who are not transplant candidates; however, its use in younger patients with progressive diseases is unclear. We sought to evaluate the cost-effectiveness of DT-VAD in Duchenne muscular dystrophy (DMD) patients with advanced HF. We created a Markov-state transition model (5-year horizon) to compare survival, costs, and quality of life (QOL) between medical management and DT-VAD in DMD with advanced HF. Model input parameters were derived from the literature. We used sensitivity analyses to explore uncertainty around model assumptions. DT-VAD had higher costs ($435,602 vs. $125,696), survival (3.13 vs. 0.60 years), and quality-adjusted survival (1.99 vs. 0.26 years) than medical management. The incremental cost-effectiveness ratio (ICER) for DT-VAD was $179,086 per quality-adjusted life year (QALY). In sensitivity analyses that were widely varied to account for uncertainty in model assumptions, the DT-VAD strategy generally remained more costly and effective than medical management. Only when VAD implantation costs were <$113,142 did the DT-VAD strategy fall below the $100,000/QALY willingness-to-pay threshold commonly considered to be "cost-effective." In this exploratory analysis, DT-VAD for patients with DMD and advanced HF exceeded societal expectations for cost-effectiveness but had an ICER similar to the accepted practice of DT-VAD in adult HF patients. While more experience and research in this population is needed, our analysis suggests that DT-VAD for advanced HF in DMD should not be dismissed solely based on cost.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/economia , Distrofia Muscular de Duchenne/complicações , Análise Custo-Benefício , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/economia , Humanos , Distrofia Muscular de Duchenne/economia , Distrofia Muscular de Duchenne/cirurgia , Qualidade de Vida , Taxa de Sobrevida
4.
Pediatr Cardiol ; 36(3): 625-32, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25381624

RESUMO

The aim of the study is to explore the indications for cardiac catheterization while on extracorporeal membrane oxygenation (ECMO) and the various catheter interventions performed as well as assess the safety profile and determine the short- and intermediate-term survival. ECMO is a lifesaving intervention for pediatric patients with respiratory and/or cardiovascular failure. There is limited recent literature discussing the survival and outcomes of patients undergoing cardiac catheterization while on ECMO. A retrospective review of consecutive patients undergoing catheterization while on ECMO from 2004 to 2013 was performed. Thirty-six patients who underwent 40 cardiac catheterizations were identified. Indications for catheterization included hemodynamic/anatomic assessment of postoperative (16) and non-operative patients (7), planned catheter interventions (CI) (12), and cardiomyopathy assessment (5). CI were performed during 18 (45 %) catheterizations, including stenting of vessels/surgical shunts (9), balloon atrial septostomy (4), device closure of septal defects/vessels (3), thrombolysis of vessels (2), endomyocardial biopsy (2), and temporary pacer wire placement (1). Unexpected diagnostic information was found in 21 (52 %), and 13 patients were referred for surgical intervention. Successful decannulation was achieved in 86 % of patients. Survival to discharge was 72 % and intermediate survival was 69 % (median = 29 months). Survival was 88 % (15/17) among patients who underwent CI. There were six procedural complications (15 %); five vascular and one non-vascular. There were no complications related to patient transport. Cardiac catheterization and interventions while on ECMO are safe, with a survival to discharge of 72 %. Diagnostic information obtained from catheterization leads to management decisions which may impact survival.


Assuntos
Cateterismo Cardíaco/métodos , Oxigenação por Membrana Extracorpórea/métodos , Hemodinâmica , Alta do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/prevenção & controle , Taxa de Sobrevida , Cateterismo Cardíaco/mortalidade , Pré-Escolar , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Humanos , Lactente , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Resultado do Tratamento
5.
Circulation ; 127(16): 1702-11, 2013 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-23538380

RESUMO

BACKGROUND: Recent data suggest that the Berlin Heart EXCOR Pediatric ventricular assist device is superior to extracorporeal membrane oxygenation for bridge to heart transplantation. Published data are limited to 1 in 4 children who received the device as part of the US clinical trial. We analyzed outcomes for all US children who received the EXCOR to characterize device outcomes in an unselected cohort and to identify risk factors for mortality to facilitate patient selection. METHODS AND RESULTS: This multicenter, prospective cohort study involved all children implanted with the Berlin Heart EXCOR Pediatric ventricular assist device at 47 centers from May 2007 through December 2010. Multiphase nonproportional hazards modeling was used to identify risk factors for early (<2 months) and late mortality. Of 204 children supported with the EXCOR, the median duration of support was 40 days (range, 1-435 days). Survival at 12 months was 75%, including 64% who reached transplantation, 6% who recovered, and 5% who were alive on the device. Multivariable analysis identified lower weight, biventricular assist device support, and elevated bilirubin as risk factors for early mortality and bilirubin extremes and renal dysfunction as risk factors for late mortality. Neurological dysfunction occurred in 29% and was the leading cause of death. CONCLUSIONS: Use of the Berlin Heart EXCOR has risen dramatically over the past decade. The EXCOR has emerged as a new treatment standard in the United States for pediatric bridge to transplantation. Three-quarters of children survived to transplantation or recovery; an important fraction experienced neurological dysfunction. Smaller patient size, renal dysfunction, hepatic dysfunction, and biventricular assist device use were associated with mortality, whereas extracorporeal membrane oxygenation before implantation and congenital heart disease were not.


Assuntos
Transplante de Coração , Coração Auxiliar , Tamanho Corporal , Causas de Morte , Criança , Pré-Escolar , Comorbidade , Ensaios de Uso Compassivo , Desenho de Equipamento , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Feminino , Cardiopatias Congênitas/sangue , Cardiopatias Congênitas/cirurgia , Cardiopatias/sangue , Cardiopatias/cirurgia , Transplante de Coração/estatística & dados numéricos , Hemorragia/epidemiologia , Humanos , Hiperbilirrubinemia/epidemiologia , Lactente , Nefropatias/epidemiologia , Hepatopatias/epidemiologia , Masculino , Mortalidade , Insuficiência de Múltiplos Órgãos/epidemiologia , Modelos de Riscos Proporcionais , Risco , Acidente Vascular Cerebral/epidemiologia , Taxa de Sobrevida , Resultado do Tratamento , Listas de Espera
6.
Neurocrit Care ; 21(1): 133-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24203460

RESUMO

BACKGROUND: The aim of this study is to determine the utility of non-invasive bedside neuromonitoring, including cerebral regional oxygen saturation (rSO2) measured by near-infrared spectroscopy and serum biomarkers, in identifying children at risk from adverse neurological outcome after heart surgery. METHODS: Prospective observational study including 39 consecutive children undergoing heart surgery with cardiopulmonary bypass (CPB) and normal neurologic exam prior to surgery. Cerebral rSO2 was measured at baseline (prior to surgery) and then continuously during surgery and for the first 16 h post-operatively. Neuromarkers [neuron-specific enolase (NSE), S100ß, glial fibrillary acidic protein (GFAP), and brain-derived neurotrophic factor (BDNF)] were measured in serum at baseline, immediately after CPB and at 16 h post-operatively. Adverse neurological outcome was defined as an abnormal pediatric cerebral performance category (PCPC) scale score at 12 months after surgery. RESULTS: Sixteen children (41 %) had an abnormal PCPC scale score at the 12-month evaluation after surgery. In children with unfavorable neurological outcomes, mean cerebral rSO2 values were lower and the area-under-the-curve below a threshold of 40 and 20% below baseline were also increased. No significant differences were found in serum neuromarkers between groups at the time points that were assessed. CONCLUSIONS: Bedside determination of cerebral rSO2 may have some utility in identifying children at risk for adverse neurological outcome after heart surgery in children. Additional studies that are sufficiently powered to control for the many covariates in this patient population will be required to fully interrogate this important question. The role of serum neuromarkers in the immediate post-operative period do not appear to be helpful in this question, though more thorough interrogation of delayed periods may ultimately demonstrate some utility in answering this question.


Assuntos
Encéfalo/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Monitorização Neurofisiológica/métodos , Complicações Pós-Operatórias/diagnóstico , Biomarcadores/sangue , Encéfalo/metabolismo , Humanos , Lactente , Monitorização Neurofisiológica Intraoperatória/métodos , Oximetria , Oxigênio/metabolismo , Prognóstico , Espectroscopia de Luz Próxima ao Infravermelho , Resultado do Tratamento
7.
Chest ; 165(5): e137-e142, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38724152

RESUMO

CASE PRESENTATION: A newborn girl presented to the hospital on the first day of life because of respiratory failure. She was born at home at 37 weeks' gestation with minimal prenatal care and was found to be small for gestational age. The patient was found to have partial sternal agenesis and sternal cleft, cutis aplasia, left facial hemangioma, micrognathia, wide-spaced nipples, and low-set ears. The mother's and baby's urine toxicology screening were positive for amphetamines. Chest radiographs on admission showed bilateral hazy opacities. CT scan of the chest showed an absent sternum with midline chest wall concavity. The patient was monitored preoperatively in the cardiac ICU for risks of arrythmia, respiratory failure, altered cardiac output, and acute cardiopulmonary decompensation.


Assuntos
Esterno , Humanos , Feminino , Esterno/anormalidades , Esterno/diagnóstico por imagem , Recém-Nascido , Anormalidades Múltiplas/diagnóstico , Tomografia Computadorizada por Raios X , Hemangioma/diagnóstico , Hemangioma/complicações , Hemangioma/diagnóstico por imagem , Anormalidades Musculoesqueléticas/diagnóstico por imagem , Anormalidades Musculoesqueléticas/diagnóstico
8.
J Heart Lung Transplant ; 43(6): 889-900, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38713124

RESUMO

BACKGROUND: There is no FDA-approved left ventricular assist device (LVAD) for smaller children permitting routine hospital discharge. Smaller children supported with LVADs typically remain hospitalized for months awaiting heart transplant-a major burden for families and a challenge for hospitals. We describe the initial outcomes of the Jarvik 2015, a miniaturized implantable continuous flow LVAD, in the NHLBI-funded Pumps for Kids, Infants, and Neonates (PumpKIN) study, for bridge-to-heart transplant. METHODS: Children weighing 8 to 30 kg with severe systolic heart failure and failing optimal medical therapy were recruited at 7 centers in the United States. Patients with severe right heart failure and single-ventricle congenital heart disease were excluded. The primary feasibility endpoint was survival to 30 days without severe stroke or non-operational device failure. RESULTS: Of 7 children implanted, the median age was 2.2 (range 0.7, 7.1) years, median weight 10 (8.2 to 20.7) kilograms; 86% had dilated cardiomyopathy; 29% were INTERMACS profile 1. The median duration of Jarvik 2015 support was 149 (range 5 to 188) days where all 7 children survived including 5 to heart transplant, 1 to recovery, and 1 to conversion to a paracorporeal device. One patient experienced an ischemic stroke on day 53 of device support in the setting of myocardial recovery. One patient required ECMO support for intractable ventricular arrhythmias and was eventually transplanted from paracorporeal biventricular VAD support. The median pump speed was 1600 RPM with power ranging from 1-4 Watts. The median plasma free hemoglobin was 19, 30, 19 and 30 mg/dL at 7, 30, 90 and 180 days or time of explant, respectively. All patients reached the primary feasibility endpoint. Patient-reported outcomes with the device were favorable with respect to participation in a full range of activities. Due to financial issues with the manufacturer, the study was suspended after consent of the eighth patient. CONCLUSION: The Jarvik 2015 LVAD appears to hold important promise as an implantable continuous flow device for smaller children that may support hospital discharge. The FDA has approved the device to proceed to a 22-subject pivotal trial. Whether this device will survive to commercialization remains unclear because of the financial challenges faced by industry seeking to develop pediatric medical devices. (Supported by NIH/NHLBI HHS Contract N268201200001I, clinicaltrials.gov 02954497).


Assuntos
Estudos de Viabilidade , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Pré-Escolar , Criança , Masculino , Lactente , Feminino , Estudos Prospectivos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/fisiopatologia , Miniaturização , Desenho de Prótese , Resultado do Tratamento , Estados Unidos
9.
Ann Thorac Surg ; 115(5): 1223-1228, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36702292

RESUMO

BACKGROUND: Despite the demonstrated utility of surgeon-fashioned polytetrafluoroethylene (PTFE) valved conduits, methods for educating surgeons to reproducibly construct these conduits are lacking. We present a surgeon education process and early outcomes for children receiving surgeon-fashioned PTFE valved conduits during the initial learning curve. METHODS: The educational curriculum included 4 hours of proctored instruction/supervised valve construction, followed by 2 hours of individual practice. A surgeon with prior mastery of the technique provided templated designs, videos, and follow-up consultation. A retrospective medical record review (2017-2022) described early outcomes and valve function for patients receiving surgeon-fashioned PTFE right ventricle-to-pulmonary artery conduits. RESULTS: Two surgeons were educated using the method described. Fifteen valved conduits were implanted in 14 patients (median patient age, 38 months; conduit size range, 10-24 mm). At discharge, no patient had more than mild stenosis or regurgitation, and 12 of 15 valves (80%) had none or trivial regurgitation. Median follow-up was 14 months (range, 1-52 months). At the last follow-up, median peak conduit gradient of the 15 valves was low (18 mm Hg), 1 (7%) had moderate stenosis, and 1 (7%) had mild-moderate regurgitation. Two conduits were replaced concomitantly during repair of associated lesions at 14 and 38 months (sizes 10 and 12 mm, respectively). There were no deaths and no infectious complications. CONCLUSIONS: Four hours of proctored surgeon education plus deliberate practice is an effective method for teaching valved PTFE conduit construction and is associated with excellent early valve function. This study provides educational methods and initial evidence of safety for congenital surgeons wishing to learn and adopt this technique.


Assuntos
Cardiopatias Congênitas , Próteses Valvulares Cardíacas , Cirurgiões , Criança , Humanos , Pré-Escolar , Estudos Retrospectivos , Constrição Patológica/complicações , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/complicações , Politetrafluoretileno , Resultado do Tratamento
10.
Pediatr Crit Care Med ; 13(6): e363-71, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22940857

RESUMO

OBJECTIVES: To determine whether activated partial thromboplastin times are a better heparin management tool than activated clotting times in pediatric extracorporeal membrane oxygenation. DESIGN: A single-center retrospective analysis of perfusion and patient records. SETTING: Academic pediatric tertiary care center. PATIENTS: Pediatric patients (<21 yrs old) requiring extracorporeal membrane oxygenation support initiated at Children's Hospital of Pittsburgh. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Point-of-care activated clotting time and activated partial thromboplastin time values, clinical laboratory activated partial thromboplastin time values, weight-normalized heparin administration (units/kg/hr), and reported outcomes were collected for pediatric patients treated for cardiac and/or respiratory failure with extracorporeal membrane oxygenation. Spearman's ranked correlations were performed for each coagulation test compared to heparin dosage. The Bland-Altman test was used to determine the validity of the point-of-care activated partial thromboplastin time. Hazard analysis was conducted for outcomes and complications for patients whose heparin management was based on the clinical laboratory activated partial thromboplastin time or the activated clotting time. Only the clinical laboratory activated partial thromboplastin time showed a correlation (ρ = 0.40 vs. ρ = -0.04 for activated clotting time) with the heparin administration (units/kg/hr). Point-of-care activated partial thromboplastin time and activated partial thromboplastin time values correlated well (ρ = 0.76), with <5% of samples showing a difference outside 2 SDs, but differences in their absolute values (Δactivated partial thromboplastin time = 100 secs) preclude them from being interchangeable measures. Furthermore, despite no effective change in the mean activated clotting time, cardiac patients showed a significantly improved correlation to heparin dose for all coagulation tests (e.g., point-of-care activated partial thromboplastin time ρ = 0.60). Management of patients with the clinical laboratory activated partial thromboplastin time did not significantly affect patient survival rates but did significantly reduce bleeding complications and significantly increased clotting in the extracorporeal membrane oxygenation circuit. A hazard analysis demonstrated that bleeding complications were associated with an increased risk of mortality, whereas clotting complications in the extracorporeal membrane oxygenation circuit were not. CONCLUSIONS: The activated clotting time is not an accurate monitoring tool for heparin management in pediatricextracorporeal membrane oxygenation. The point-of-care activated partial thromboplastin time correlates well with the clinical laboratory activated partial thromboplastin time but cannot be substituted for the clinical laboratory activated partial thromboplastin time values. Management of pediatric extracorporeal membrane oxygenation patients with the clinical laboratory activated partial thromboplastin time reduced bleeding complications which are associated with increases in mortality.


Assuntos
Anticoagulantes/administração & dosagem , Oxigenação por Membrana Extracorpórea , Hemorragia/prevenção & controle , Heparina/administração & dosagem , Tempo de Tromboplastina Parcial , Tempo de Coagulação do Sangue Total , Adolescente , Criança , Pré-Escolar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/terapia , Hemorragia/etiologia , Humanos , Lactente , Sistemas Automatizados de Assistência Junto ao Leito , Insuficiência Respiratória/terapia , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas
11.
J Clin Apher ; 27(5): 274-7, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22811253

RESUMO

Intravascular hemolysis and resulting plasma-free hemoglobin elevation has been associated with acute kidney injury via several mechanisms. Proximal tubular injury due to iron compound deposition and nitric oxide sequestration with subsequent impairment of the microcirculation and hypoperfusion are specific adverse effects of intravascular hemolysis that may contribute to acute kidney injury. Therefore, removal of plasma-free hemoglobin and restoration of normal nitric oxide vasodilatory mechanisms may play a beneficial role in treating acute kidney injury secondary to acute intravascular hemolysis. We report herein the case of a 13-year-old patient with severe intravascular hemolysis and acute kidney injury and describe the role of plasma exchange with plasma replacement in his successful recovery.


Assuntos
Injúria Renal Aguda/complicações , Coração Auxiliar , Hemólise , Troca Plasmática/métodos , Injúria Renal Aguda/metabolismo , Adolescente , Creatinina/sangue , Haptoglobinas/química , Hospitalização , Humanos , Masculino , Microcirculação , Óxido Nítrico/química , Óxido Nítrico/metabolismo
12.
Cardiol Young ; 22(3): 251-62, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22008697

RESUMO

OBJECTIVE: To investigate the effect of pulsatility of venous flow waveform in the inferior and superior caval vessels on the performance of functional and "failing" Fontan patients based on two primary performance measures - the conduit power loss and the distribution of inferior caval flow (hepatic factors) to the lungs. METHODS: Doppler angiography flows were acquired from two typical extra-cardiac conduit "failing" Fontan patients, aged 13 and 25 years, with ventricle dysfunction. Using computational fluid dynamics, haemodynamic efficiencies of "failing", functional, and in vitro-generated mechanically assisted venous flow waveforms were evaluated inside an idealised total cavopulmonary connection with a caval offset. To investigate the effect of venous pulsatility alone, cardiac output was normalised to 3 litres per minute in all cases. To quantify the pulsatile behaviour of venous flows, two new performance indices were suggested. RESULTS: Variations in the pulsatile content of venous waveforms altered the conduit efficiency notably. High-frequency and low-amplitude oscillations lowered the pulsatile component of the power losses in "failing" Fontan flow waveforms. Owing to the offset geometry, hepatic flow distribution depended strongly on the ratio of time-dependent caval flows and the pulsatility content rather than mixing at the junction. "Failing" Fontan flow waveforms exhibited less balanced hepatic flow distribution to lungs. CONCLUSIONS: The haemodynamic efficiency of single-ventricle circulation depends strongly on the pulsatility of venous flow waveforms. The proposed performance indices can be calculated easily in the clinical setting in efforts to better quantify the energy efficiency of Fontan venous waveforms in pulsatile settings.


Assuntos
Angiografia Coronária/métodos , Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Fluxo Pulsátil/fisiologia , Pressão Ventricular/fisiologia , Adolescente , Adulto , Angiografia Coronária/instrumentação , Hemodinâmica , Humanos
13.
Semin Thorac Cardiovasc Surg ; 34(1): 262-272, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33333164

RESUMO

There is evidence that reducing opioid exposure in children undergoing cardiac surgery may enhance postoperative recovery. We aimed to describe a minimal opioid postoperative management protocol in children undergoing cardiac surgery and our early outcomes with this strategy. We reviewed the medical records of children (6 months-18 years) who underwent elective cardiac surgery through a median sternotomy with cardiopulmonary bypass at our institution between 2016 and 2018. All patients were managed postoperatively using a standardized protocol. 101 children (median age 5 years) were included and 85% were extubated in the operating room. Although most patients (96%) received opioids postoperatively, opioid requirements decreased steadily over time, with 88%, 58%, and 18% of children receiving opioids on postoperative day 1, 2, and 3, respectively; 41% received no opioids after postoperative day 1. The median cumulative opioid exposure was 0.25 morphine milligram equivalents per kg (interquartile range, 0.10-0.75). Greater than mild pain was rare (<10%) at each time point. The rates of operative mortality and major complication were 0% and 3%, respectively. The median postoperative length of stay was 3 days, and 13% required readmission within 30 days. Age, cardiopulmonary bypass time, and number of benzodiazepine doses were independently associated with cumulative opioid exposure. Any complication, chest tube time, and higher STAT Category were independently associated with prolonged postoperative length of stay. A minimal opioid postoperative management protocol can be safe and effective in children undergoing cardiac surgery. Future prospective studies are needed to determine optimal practice and patient selection.


Assuntos
Analgésicos Opioides , Procedimentos Cirúrgicos Cardíacos , Extubação , Analgésicos Opioides/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Pré-Escolar , Humanos , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
14.
Ann Thorac Surg ; 114(5): 1762-1770, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-34742732

RESUMO

BACKGROUND: As a formative step toward development of adult congenital heart disease (ACHD) risk-adjusted metrics, we describe The Society of Thoracic Surgeons (STS) ACHD population, procedural frequency, and early mortality. METHODS: Adults (≥18 years) with CHD (2014-2019) were identified in the STS Adult Cardiac Surgery (ASCD) and the Congenital Heart Surgery (CHSD) Databases. After deduplication, variable mapping, data concatenation, and harmonization of preprocedure factors, procedures were grouped, and unadjusted mortality was catalogued for the overall cohort and the cohort excluding patients with an isolated bicuspid aortic valve (BAV). RESULTS: Among 171 186 ACSD and 18 281 CHSD records, 152 731 unique records met inclusion criteria. Twenty-eight congenital diagnoses accounted for 86% of the overall cohort, and prevalence of ACHD increased over the study time frame. ACHD patients underwent operations to treat both acquired and CHD. Most common procedures overall and after excluding isolated BAV were aortic valve replacement (AVR), ascending aortic surgery, and coronary artery bypass grafting (CABG). After excluding isolated BAV, major procedure combinations occurred in 46% (31% had 2 major procedures and 3% had ≥4), and the most prevalent combinations included AVR + CABG (n = 2352), AVR + subaortic stenosis repair (n = 1481), and AVR + ascending aortic surgery (n = 1239). Unadjusted 30-day mortality was procedure dependent, 2.8% overall and 3.6% with isolated BAV excluded. CONCLUSIONS: The ACHD surgical population is heterogenous, and patients undergo surgery for CHD-related and adult/acquired procedure combinations. Early mortality is variable and influenced by surgical complexity. Excluding isolated BAV patients and developing procedure-based ACHD mortality risk models may be ideal but will require empirically derived grouping and collaboration.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Cardiopatias Congênitas , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Adulto , Humanos , Doenças das Valvas Cardíacas/diagnóstico , Cardiopatias Congênitas/cirurgia , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
15.
Artif Organs ; 35(6): 602-13, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21463346

RESUMO

The PediaFlow pediatric ventricular assist device (VAD) is a magnetically levitated turbodynamic pump under development for circulatory support of small children with a targeted flow rate range of 0.3-1.5 L/min. As the design of this device is refined, ensuring high levels of blood biocompatibility is essential. In this study, we characterized platelet activation during the implantation and operation of a second generation prototype of the PediaFlow VAD (PF2) and also performed a series of surgical sham studies to examine purely surgical effects on platelet activation. In addition, a newly available monoclonal antibody was characterized and shown to be capable of quantifying ovine platelet activation. The PF2 was implanted in three chronic ovine experiments of 17, 30, and 70 days, while surgical sham procedures were performed in five ovines with 30-day monitoring. Blood biocompatibility in terms of circulating activated platelets was measured by flow cytometric assays with and without exogenous agonist stimulation. Platelet activation following sham surgery returned to baseline in approximately 2 weeks. Platelets in PF2-implanted ovines returned to baseline activation levels in all three animals and showed an ability to respond to agonist stimulation. Late-term platelet activation was observed in one animal corresponding with unexpected pump stoppages related to a manufacturing defect in the percutaneous cable. The results demonstrated encouraging platelet biocompatibility for the PF2 in that basal platelet activation was achieved early in the pump implant period. Furthermore, this first characterization of the effect of a major cardiothoracic procedure on temporal ovine platelet activation provides comparative data for future cardiovascular device evaluation in the ovine model.


Assuntos
Materiais Biocompatíveis/metabolismo , Coração Auxiliar , Ativação Plaquetária , Animais , Criança , Desenho de Equipamento , Humanos , Teste de Materiais , Implantação de Prótese , Ovinos
16.
Artif Organs ; 35(1): 9-21, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20626737

RESUMO

The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.


Assuntos
Coração Auxiliar , Teste de Materiais , Animais , Desenho de Equipamento , Hematócrito , Hemodinâmica , Hemólise , Humanos , Implantes Experimentais , Lactente , Recém-Nascido , Magnetismo , Miniaturização , Ativação Plaquetária , Ovinos
17.
Ann Thorac Surg ; 112(1): 132-138, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32768428

RESUMO

BACKGROUND: Contemporary practice patterns and outcomes for aortic valve replacement (AVR) among young and middle-aged adults are unknown given guideline modifications for surgical AVR (SAVR) and increasing transcatheter AVR (TAVR) acceptance. This study describes SAVR and TAVR use and outcomes using The Society of Thoracic Surgeons (STS) National Databases. METHODS: Adults 18 to 55 years of age in the Congenital Heart Surgery Database (CHSD) and the Adult Cardiac Surgery Database (ACSD) who underwent SAVR or TAVR from 2013 to 2018 were included. Perioperative characteristics and early outcomes were described by valve type. Multivariable regression identified determinants of death, length of hospital stay, and a composite end point of renal failure, persistent neurologic deficit, readmission, and reoperation. RESULTS: The study analyzed 1580 unique CHSD and 44,173 ACSD operations, 16% of which were performed in patients with congenital heart disease. Valve use included the following: TAVR, 1%; mechanical, 42%; bioprosthetic, 55%; autograft, 0.6%; homograft, 1.2%; and Ozaki, 0.4%. Over time, TAVR volumes increased by 167%. The 30-day mortality was as follows: TAVR, 3.8%; mechanical, 3.2%; bioprosthetic, 3.7%; autograft, 0.6%; homograft, 9%; and Ozaki, 3.4%. Stroke rate was lower for isolated SAVR vs isolated TAVR (0.9% vs 2.4%; P = .002). In multivariable analyses, mortality risk was lower with mechanical valves, congenital morbidity risk was higher with TAVR, and length of stay was shorter with TAVR. CONCLUSIONS: TAVR is increasingly used for adults younger than 55 years of age. Given the uniformly excellent results with SAVR, including both mortality and morbidity-particularly regarding stroke, our data favor SAVR in this population, but a prospective trial is needed. Ongoing efforts to harmonize variables and outcomes definitions between the ACSD and CHSD are valuable.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/tendências , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/tendências , Adulto , Bases de Dados Factuais , Feminino , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese/tendências , Adulto Jovem
18.
Pediatr Crit Care Med ; 11(5): 589-92, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20124943

RESUMO

OBJECTIVE: To characterize the effects of dexmedetomidine on the pulmonary artery pressure in patients after congenital cardiac surgery. DESIGN: Prospective observational pilot study. SETTING: Pediatric cardiac intensive care unit at a university hospital. PATIENTS: Twenty-two patients who received dexmedetomidine after cardiothoracic surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: An echocardiogram was performed at three time points: 1) baseline (T0); 2) 6 mins after dexmedetomidine loading (T1); and 3) 1 hr after initiation of dexmedetomidine infusion (T2). Transthoracic echocardiography was used to estimate pulmonary artery pressure based on tricuspid regurgitant velocity (4 x Velocity2) plus central venous pressure. Twenty-two patients aged 0.9 yrs old (interquartile range, 7.9) were enrolled at a median of 1 hr (1.5) after surgery. Dexmedetomidine loading, 0.62 microg/kg (0.5), was given in all patients followed by 0.5 microg/kg/hr (0.6) at T1 and 0.65 microg/kg/hr (0.5) at T2. None of the patients had any increase in pulmonary artery pressure. Overall, the pulmonary artery pressure decreased from 30 mm Hg (13) at T0 to 24 mm Hg (10) at T1 and 26 mm Hg (8) at T2 (p < .001). The pulmonary artery pressure/systemic systolic blood pressure ratio decreased from 33% (12) at T0 to 23% (15) at T1 and 25% (13) at T2 (p = .002). There was no difference in the left ventricular function, Fio2, oxygen %, Po2, CO2, and vasoactive agents. CONCLUSIONS: Administration of dexmedetomidine after congenital cardiac surgery was not associated with any increase in pulmonary artery pressure.


Assuntos
Agonistas de Receptores Adrenérgicos alfa 2/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Dexmedetomidina/farmacologia , Cardiopatias Congênitas/cirurgia , Hipnóticos e Sedativos/farmacologia , Artéria Pulmonar/efeitos dos fármacos , Agonistas de Receptores Adrenérgicos alfa 2/uso terapêutico , Criança , Pré-Escolar , Dexmedetomidina/uso terapêutico , Ecocardiografia , Feminino , Humanos , Hipnóticos e Sedativos/uso terapêutico , Lactente , Masculino , Projetos Piloto , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia
19.
Artif Organs ; 34(11): 1010-6, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21092044

RESUMO

Conduits available for right ventricular outflow tract (RVOT) reconstruction eventually become stenotic and/or insufficient due to calcification. In order to reduce the incidence of reoperations we have developed and used a bicuspid valved polytetrafluoroethylene (PTFE) conduit for the RVOT reconstruction. The purpose of this study is to investigate the hemodynamic performance of the new design using a pediatric in vitro right heart mock loop. PTFE conduit has been used for the complete biventricular repair of 20 patients (age 1.7±6 years) with cyanotic congenital defects. To account for the large variability of conduit sizes, 14, 16, 22, and 24-mm conduit sizes were evaluated using an in vitro flow loop comprised of a pulsatile pump with cardiac output (CO) of 1.2-3.2L/min, bicuspid valved RVOT conduit, pulmonary artery, venous compartments, and the flow visualization setup. We recorded the diastolic valve leakage and pre- and post-conduit pressures in static and pulsatile settings. In vitro valve function and overall hemodynamic performance was evaluated using high-speed cameras and ultrasonic flow probes. Three-dimensional flow fields for different in vivo conduit curvatures and inflow regimes were calculated by computational fluid dynamics (CFD) analysis to further aid the conduit design process. The average pressure drop over the valved conduits was 0.8±1.7mm Hg for the CO range tested. Typical values for regurgitant fraction, peak-to-peak pressure gradient, and effective office area were 23±2.1%, 13±2.4mm Hg, and 1.56±0.2 cm(2) , respectively. High-speed videos captured the intact valve motion with asymmetrical valve opening during the systole. CFD simulations demonstrated the flow skewness toward the major curvature of the conduit based on the pulmonic curvature. In vitro evaluation of the bicuspid valved PTFE conduit coincides well with acceptable early clinical performance (mild insufficiency), with relatively low pressure drop, and intact valve motion independent from the conduit curvature, orientation or valve location, but at the expense of increased diastolic flow regurgitation. These findings benchmark the baseline performance of the bicuspid valved conduit and will be used for future designs to improve valve competency.


Assuntos
Circulação Coronária , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Politetrafluoretileno , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Débito Cardíaco , Criança , Pré-Escolar , Simulação por Computador , Desenho Assistido por Computador , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Humanos , Lactente , Recém-Nascido , Teste de Materiais , Modelos Cardiovasculares , Desenho de Prótese , Circulação Pulmonar , Fluxo Pulsátil , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Gravação em Vídeo
20.
Ann Thorac Surg ; 109(2): e131-e133, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31301275

RESUMO

Aberrant right subclavian artery, or arteria lusoria, is a common congenital anomaly of the aortic arch and may be associated with dysphagia. Surgical treatment, particularly in children, remains controversial. Current surgical interventions include supraclavicular and thoracotomy approaches, as well as hybrid endovascular techniques. However, these techniques have significant limitations and varying degrees of success. This case report describes a 2-site operation whereby the arteria lusoria is transected via a left thoracotomy and subsequently re-implanted into the right common carotid artery via a median sternotomy. This approach has provided complete symptom resolution for dysphagia lusoria in 2 children.


Assuntos
Anormalidades Cardiovasculares/complicações , Transtornos de Deglutição/cirurgia , Artéria Subclávia/anormalidades , Toracotomia/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Anormalidades Cardiovasculares/diagnóstico , Anormalidades Cardiovasculares/cirurgia , Criança , Pré-Escolar , Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/etiologia , Seguimentos , Humanos , Imageamento Tridimensional , Masculino , Artéria Subclávia/cirurgia , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler Dupla
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA