Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur J Oral Sci ; 132(4): e12993, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38778467

RESUMO

This study aimed to investigate the bisphenol A (BPA) release from four CAD/CAM splint materials: three polycarbonate-based (DD BioSplint C, Splint Plus Biostar, Temp Premium Flexible) and one polymethylmethacrylate-based (Temp Basic) material. From each material, ten cylindrical samples (n = 40) were immersed in high-performance liquid chromatography (HPLC) grade water following ISO 10993-12 and incubated for 24 h in an incubation shaker at 37°C and 112 rpm. Following BPA derivatization, analysis was performed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). After 24 h of incubation, all investigated materials released significant amounts of BPA compared to water blanks. The material-dependent elution increased in the following order: DD BioSplint C < Splint Plus Biostar < Temp Basic < Temp Premium Flexible. Subtracting extraneous BPA, the concentrations ranged between 2.27 ng/mL and 12.65 ng/mL. After extrapolating the concentrations in relation to the average surface area of occlusal splints, the amount of BPA per mL exceeded the Tolerable Daily Intake (TDI) set by the European Union for a person weighing 70 kg by 1.32-6.16 times. Contrary to the release from previously investigated materials, BPA elution from CAD/CAM splint materials was highly elevated. Considering the increasing adaptation of CAD/CAM techniques, elution from them may represent a relevant BPA source in daily dental practice.


Assuntos
Compostos Benzidrílicos , Desenho Assistido por Computador , Fenóis , Compostos Benzidrílicos/análise , Compostos Benzidrílicos/química , Fenóis/análise , Cromatografia Líquida de Alta Pressão , Cimento de Policarboxilato/química , Polimetil Metacrilato/química , Espectrometria de Massas em Tandem , Teste de Materiais , Contenções , Materiais Dentários/química , Humanos
2.
J Oral Rehabil ; 51(4): 733-742, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38100245

RESUMO

BACKGROUND: Increased daytime sleepiness is a frequently reported symptom in patients with pronounced dysgnathia. OBJECTIVES: This study investigated possible correlations using home peripheral arterial tonometry (PAT) and oropharyngeal airway volume determination in patients with dysgnathia and daytime sleepiness. METHODS: Twenty patients (13 male, median age 27.6 ± 6.8 years) with abnormal sleep history and 10 skeletal neutral configured controls (6 male, median age 29.5 ± 4.2 years) with normal sleep history were examined. Patients and controls were evaluated for apnoea-hypopnoea index (AHI), respiratory disturbance index (RDI), oxygen desaturation index (ODI), snoring volume (dB), total sleep time (TST) and REM-percentage (REM). Airway volumetry was measured via CBCT. Individual user experience for PAT was assessed using the User Experience Questionnaire (UEQ). RESULTS: Patients had significantly higher respiratory scores than controls. AHI increased 4.6-fold (p = .006), RDI 2.5-fold (p = .008) and ODI 6.4-fold (p < .001). Oropharyngeal volumes showed a 30% decrease (p = .003). dB, TST and REM showed no significant differences. AHI (r = -.51; p = .005), ODI (r = -.60; p < .001) and RDI (r = -.45; p = .016) correlated negatively with pharyngeal volume. Wits appraisal correlated negatively with oropharyngeal volume (r = -.47; p = .010) and positively with AHI (r = .41; p = .03) and ODI (r = .49; p = .007). dB and TST (r = -.49; p = .008) and REM and RDI (r = -.43; p = .02) correlated negatively. UEQ-KPI (2.17 ± 0.24) confirmed excellent usability of PAT. CONCLUSION: Patients with mandibular retrognathia and abnormal sleep history showed significantly higher respiratory indices and smaller oropharyngeal volumes than neutrally configured controls. The dygnathia severity directly influenced the risk of obstructive sleep apnoea.


Assuntos
Distúrbios do Sono por Sonolência Excessiva , Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Humanos , Masculino , Adulto Jovem , Adulto , Síndromes da Apneia do Sono/diagnóstico , Sono , Faringe/diagnóstico por imagem , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia
3.
Heliyon ; 10(6): e28130, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38524618

RESUMO

Statement of problem: A working knowledge of the analytical capacities of contemporary registration methods is essential for prosthetic treatment; however, there is a paucity of studies which coherently investigate the capabilities and limitations of the various diagnostic procedures utilized for prosthetic occlusion. Purpose: The present prospective clinical study aimed to evaluate the similarities and differences among contemporary registration methods through comparative analysis. Material and methods: The habitual static occlusion of 19 healthy individuals (14 women; mean age ± standard deviation, 30.8 ± 4.8 years) was analyzed 3 times a day, using shimstock foil, occlusal foil, wax registration, silicone registration, and computerized registration. The procedures were repeated after 14 days. Statistical analyses included all registrations referencing the first measurement point to assess the mean values of antagonistic contacts and the differences between these measurements. Pearson's and Kendall's correlation analyses were performed as part of the coherent mixed logistic regression model, and marginal probabilities were calculated using the registration technique and repeated measurements. Results: Strong correlations were found among the various registration techniques. The largest effect sizes were observed among the wax, silicone, occlusion foil, and computerized registrations (r = 0.95, P < 0.001 to r = 0.62, P < 0.001), while the lowest effect sizes were found for shimstock correlations (τ = 0.41, P < 0.001 to τ = 0.27, P < 0.001). Occlusal changes per maxillary arch were observed referencing the first measurement time with wax registration (P < 0.001; 7.4%), shimstock foil (P < 0.001; 13.8%), computerized registration (P < 0.001; 20.3%), silicone registration (P = 0.009; 66.3%), and occlusion foil (P < 0.001; 98.8%). Occlusal changes per maxillary tooth were observed from the first incisor (P < 0.001; 5.7%) to the third molar (P < 0.001; 18.1%). Conclusions: The results of the present study revealed that there are strong overall correlations among the various contemporary registration techniques. The different affinities of the techniques used to register occlusal changes, however, showed differences in the measurement techniques, which should be neither over- nor underestimated. The differential tendencies of teeth to change should be considered, even if a hypervariable system is assumed.

4.
Clin Exp Dent Res ; 10(2): e864, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38433291

RESUMO

OBJECTIVES: Magnetron sputtering was evaluated to equip surfaces of orthodontic elastomeric ligatures with silver and bismuth nanofilms. MATERIAL AND METHODS: Antibacterial properties were evaluated by the adhesion of Streptococcus mutans. Polyurethane-based elastomeric ligatures were coated with silver and bismuth nanofilms via direct current magnetron sputtering. Surface roughness (Ra ) and surface-free energy (SFE) were assessed. Coated specimens were incubated with S. mutans for 2 h. Adhering bacteria were visualized by Hoechst staining and quantified by an ATP-based luminescence assay. One-way analysis of variance with Tukey post hoc testing and Pearson correlation analysis were performed (p < .05) to relate bacterial adhesion to surface roughness and surface-free energy. RESULTS: Elastomeric ligatures were successfully coated with silver and bismuth nanofilms. Ra was significantly reduced by silver coating. Silver and bismuth coatings showed significantly higher SFE than controls. Adhesion of S. mutans was significantly decreased by silver coating. No correlation between bacterial adhesion and SFE was found. Correlation between bacterial adhesion and Ra was positive but not statistically significant. CONCLUSIONS: Magnetron sputtering proved to be a feasible method to equip orthodontic elastomeric ligatures with silver and bismuth nanofilms. Silver coatings of elastomeric ligatures may reduce white spots and carious lesions in orthodontic patients. Future research is required to stabilize coatings.


Assuntos
Cárie Dentária , Prata , Humanos , Prata/farmacologia , Bismuto/farmacologia , Estudos de Viabilidade , Antibacterianos
5.
Head Face Med ; 20(1): 10, 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38365709

RESUMO

BACKGROUND: Real-time magnetic resonance imaging (rtMRI) is essential for diagnosing and comprehending temporomandibular joint (TMJ) movements. Current methods for tracking and analysis require manual landmark placement on each acquisition frame. Therefore, our study aimed to assess the inter- and intra-rater reliability of placing cephalometric landmarks in frames from a dynamic real-time TMJ MRI. MATERIAL AND METHODS: Four real-time MRIs of the right TMJ were taken during mandibular movement at ten frames per second. Seven dentists identified ten landmarks on two frames (intercuspal position-ICP-and maximum mouth opening-MMO) twice at a two-week interval, yielding 112 tracings. Six typical cephalometric measurements (angles and distances) were derived from these landmarks. The reliabilities of landmarks and measurements were evaluated using distance-based (dbICC), linear mixed effect model intraclass correlation (lmeICC), and standard ICC. RESULTS: The average inter-rater reliability for the landmarks stood at 0.92 (dbICC) and 0.93 (lmeICC). The intra-rater reliability scores were 0.97 and 0.98. Over 80% of the landmarks showed an ICC greater than 0.98 (inter-rater) and over 0.99 (intra-rater). The lowest landmark ICC was observed for the orbitale and the oblique ridge of the mandibular ramus. However, the cephalometric angle and distance measurements derived from these landmarks showed only moderate to good reliability, whereas the reliability in the frames with ICP was better than those with MMO. Measurements performed in the ICP frame were more reliable than measurements in the MMO frame. CONCLUSION: While dentists reliably localize isolated landmarks in real-time MRIs, the cephalometric measurements derived from them remain inconsistent. The better results in ICP than MMO are probably due to a more familiar jaw position. The higher error rate of the TMJ measurements in MMO could be associated with a lack of training in real-time MRI analysis in dentistry.


Assuntos
Imageamento por Ressonância Magnética , Articulação Temporomandibular , Humanos , Reprodutibilidade dos Testes , Articulação Temporomandibular/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mandíbula , Cefalometria/métodos , Variações Dependentes do Observador
6.
J Orofac Orthop ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568461

RESUMO

OBJECTIVES: Occupational hand eczema is a common inflammatory skin condition among healthcare professionals. Orthodontists are frequently exposed to a variety of irritating and allergenic substances, and therefore they belong to a predisposed group to develop hand eczema. However, current data on the prevalence and predisposing factors among orthodontists to provide adequate prophylaxis are lacking. METHODS: An anonymous online survey was conducted in Germany between January and February 2023 and distributed to 2402 orthodontists. The questionnaire addressed general information on current skin status, as well as occupational skin exposure and skin care. RESULTS: A total of 209 orthodontists responded to the survey. Seventy-four percent reported experiencing hand eczema-specific symptoms within the last 12 months, with 24% describing moderate and 10% describing severe symptoms. The average daily glove wearing time was stated to be 6 ± 2 h. The most frequently reported triggers at work were frequent hand washing (62.7%) and hand disinfection (59.1%). Among all the respondents, 22.6% stated not using either barrier cream or moisturizer. CONCLUSIONS: This study showed a high prevalence of hand eczema symptoms among orthodontists, which is probably due to frequent disinfection, hand washing, and contact with allergens such as acrylates. In this professional group especially, against a background of future increasing acrylate and epoxy resin exposures due to in-office three-dimensional printing processes, timely education and skin protection could decisively counteract the pathogenesis of hand eczema.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA