Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Nucl Phys A ; 10212022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35967889

RESUMO

Excitation function of the 54Fe(p,α)51Mn reaction was measured from 9.5 to 18 MeV E 0 , p + by activating a foil stack of 54Fe electrodeposited on copper substrates. Residual radionuclides were quantified by HPGe gamma ray spectrometry. Both 51Mn (t 1/2 = 46.2 min, 〈 E ß + 〉 = 963.7 keV , I ß + = 97 % ; E γ = 749.1 keV, I γ = 0.265%) and its radioactive daughter, 51Cr (t 1/2 = 27.704d, E γ = 320.1 keV, I γ = 9.91%), were used to indirectly quantify formation of 51Mn. Results agree within uncertainty to the only other measurement in literature and predictions of default TALYS theoretical code. Final relative uncertainties are within ±12%.

2.
J Hand Surg Am ; 46(3): 187-199, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33243590

RESUMO

PURPOSE: Our primary purpose was to evaluate the reliability of telephone administration of the Patient-Reported Outcomes Measurement Information System (PROMIS) Upper Extremity (UE) Computer Adaptive Test (CAT) version 2.0 in a hand and upper extremity population, and secondarily to make comparisons with the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand (QuickDASH). METHODS: Patients more than 1 year out from hand surgeries performed at a single tertiary institution were enrolled. Half of the patients completed telephone PROMIS UE CAT and QuickDASH surveys first, followed by computer-based surveys 1 to 10 days later, and the other half completed them in the reverse order. Telephone surveys were readministered 2 to 6 weeks later to evaluate test-retest reliability. Concordance correlation coefficients (CCCs) were used to assess agreement between telephone and computer-based scores, and intraclass correlation coefficients (ICCs) were used to assess test-retest reliability. The proportion of patients with discrepancies in follow-up scores that exceeded estimates of the minimal clinically important difference (MCID) was evaluated. RESULTS: For the 89 enrolled patients, the PROMIS UE CAT CCC was 0.82 (83% confidence interval [83% CI], 0.77-0.86; good), which was significantly lower than 0.92 (83% CI, 0.89-0.94; good to excellent) for the QuickDASH. The PROMIS UE CAT ICC did not differ significantly from the QuickDASH (0.85 and 0.91, respectively). Differences in telephone versus computer scores exceeded 5 points (MCID estimate) for the PROMIS UE CAT in 34% of patients versus 5% of patients exceeding 14 points (MCID estimate) for the QuickDASH. CONCLUSIONS: Significantly better reliability was observed for the QuickDASH than the PROMIS UE CAT when comparing telephone with computer-based score acquisition. Over one-third of patients demonstrated a clinically relevant difference in scores between the telephone and the computer-administered tests. We conclude that the PROMIS UE CAT should only be administered through computer-based methods. CLINICAL RELEVANCE: These findings suggest that differences in collection methods for the PROMIS UE CAT may systematically affect the scores obtained, which may erroneously influence the interpretation of postoperative scores for hand surgery patients.


Assuntos
Avaliação da Deficiência , Medidas de Resultados Relatados pelo Paciente , Computadores , Humanos , Reprodutibilidade dos Testes , Telefone , Extremidade Superior/cirurgia
3.
J Pediatr Orthop ; 39(8): 400-405, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31393297

RESUMO

BACKGROUND: The Shilla procedure was designed to correct and control early-onset spinal deformity while harnessing a child's remaining spinal growth. It allows for controlled axial skeletal growth within the construct, avoiding the need for frequent surgeries to lengthen implants. We hypothesized that curve characteristics evolve over time after initial apex fusion and placement of the Shilla implants. The purpose of this study was to identify trends in curve evolution after Shilla implantation and understand how these changes influence ultimate outcome. METHODS: A single-center, retrospective review of all patients with Shilla implants in place for ≥5 years yielded 21 patients. Charts and radiographs were reviewed to compare coronal curve characteristics preoperatively, postoperatively, and at last follow-up to note changes in the apex of the primary curve. Also noted were the development of adjacent compensatory curves, the overall vertical spinal growth, and the need for definitive spinal fusion once skeletal maturity was reached. RESULTS: Of the 21 patients, the curve apex migrated caudally in 12 patients (57%) and cephalad in 1 patient (5%), with a mean migration of 2.7 vertebral levels. Two patients (10%) developed new, significant compensatory curves (1 caudal and 1 cephalad). All patients demonstrated spinal growth in T1-S1 length following index surgery (mean, 45 mm). At skeletal maturity, 10 patients underwent definitive posterior spinal fusion and instrumentation, and 3 underwent implant removal alone. CONCLUSIONS: This study constitutes the longest follow-up of Shilla patients evaluating curve and implant behavior. Results of this review suggest that the apex of the fused primary curve shifts in approximately 62% of patients, with nearly all of these (92%) involving a distal migration. Compensatory curves did develop after Shilla placement as well. Overall, these findings represent adding-on distal to the apex after Shilla instrumentation rather than a crankshaft phenomenon about the apex. A better understanding of spinal growth mechanics and outcomes after Shilla placement may improve our ability to appropriately select patients and instrumentation levels. LEVEL OF EVIDENCE: Level III.


Assuntos
Escoliose , Fusão Vertebral , Coluna Vertebral , Adolescente , Criança , Feminino , Seguimentos , Humanos , Masculino , Próteses e Implantes , Radiografia/métodos , Estudos Retrospectivos , Escoliose/diagnóstico , Escoliose/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fusão Vertebral/estatística & dados numéricos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Resultado do Tratamento
4.
J Oncol Pharm Pract ; 24(5): 389-392, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28355971

RESUMO

Pembrolizumab, a selective anti-PD-1 humanized monoclonal antibody, reactivates T cells to fight cancer. Immune-related adverse events such as autoimmune colitis, pneumonitis, hepatitis, nephritis, hypophysitis, and thyroiditis may occur during, or weeks to months after therapy. Pemprolizumab-induced synovitis is rarely reported. With the wide use of immunotherapy to treat cancers, physicians need to be aware of this rare immune-related adverse event and provide immediate treatment to avoid permanent joint damage.


Assuntos
Anticorpos Monoclonais Humanizados/efeitos adversos , Antineoplásicos/efeitos adversos , Sinovite/induzido quimicamente , Anticorpos Monoclonais Humanizados/administração & dosagem , Antineoplásicos/uso terapêutico , Feminino , Humanos , Imunoterapia , Melanoma/tratamento farmacológico , Pessoa de Meia-Idade
5.
J Shoulder Elbow Surg ; 26(9): 1670-1675, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28478900

RESUMO

BACKGROUND: Although the safety of the beach-chair position (BCP) is widely accepted, rare devastating neurologic complications have been reported and attributed to cerebral hypoperfusion. Cerebral oxygenation (regional oxygen saturation [rSO2]) can be monitored noninvasively using near-infrared spectroscopy. The purpose of this study was to determine the effect of BCP angle on cerebral oxygenation in patients undergoing shoulder surgery in the BCP. METHODS: Fifty patients undergoing shoulder arthroscopy were prospectively enrolled to participate. Following induction of general anesthesia, each patient's rSO2 was recorded at 0° of elevation and again at 30°, 45°, 60°, and 80° of elevation. Mean rSO2 values and mean differences in rSO2 were reported. RESULTS: An average total decrease of 5% in rSO2 was seen when comparing 0° with 80° (P < .001). There were statistically significant differences in rSO2 values at beach-chair angles of 0° versus 30° (P <.001), 30° versus 45° (P = .007), and 45° versus 60° (P <.001) but not between 60° and 80° (P = .12). The decrease in rSO2 was similar between each progressive increase in the beach-chair angle, leading to a linear decline in rSO2 as the BCP increased (regression slope of -0.060%/°, P <.001). No patient's cerebral oxygenation dropped greater than 20% from baseline. Neither body mass index nor American Society of Anesthesiologists score had a significant impact on the relation of rSO2 to BCP angle. CONCLUSIONS: The average drop in rSO2 is significantly less than the threshold of 20% used as an identifier for a cerebral deoxygenation event. This study illustrates the direct effect the BCP angle has on cerebral oxygenation.


Assuntos
Artroplastia do Ombro , Cérebro/metabolismo , Oxigênio/metabolismo , Posicionamento do Paciente , Adulto , Idoso , Anestesia Geral , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Espectroscopia de Luz Próxima ao Infravermelho , Adulto Jovem
6.
Sci Rep ; 11(1): 15749, 2021 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-34344931

RESUMO

Many radioisotopes with potential medical applications are difficult to produce routinely, especially those on the proton-rich side of the valley of stability. Current production methods typically use light-ion (protons or deuteron) reactions on materials of similar mass to the target radioisotope, which limits the elemental target material available and may require the use of targets with poor thermal properties (as is the case for the production of radiobromine). These reactions may also create significant amounts of proton-rich decay products which require chemical separation from the desired product in a highly radioactive environment. A promising alternative method using heavy-ion fusion-evaporation reactions for the production of the medically relevant bromine radioisotopes 76Br (t1/2 = 16.2 h) and 77Br (t1/2 = 57.0 h) is presented. Heavy-ion beams of 28Si and 16O were used to bombard natural chromium and copper targets just above the Coulomb barrier at the University of Notre Dame's Nuclear Science Laboratory to produce these bromine and precursor radioisotopes by fusion-evaporation reactions. Production yields for these reactions were measured and compared to PACE4 calculations. In addition to using more robust targets for irradiation, a simple physical-chemical separation method is proposed that will lead to very high radiopurity yields. A summary of accelerator facility requirements needed for routine production of these radioisotopes is also presented.

7.
Appl Radiat Isot ; 178: 109935, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34555596

RESUMO

The radionuclide 149Tb (t1/2 = 4.1 h) is a potential theranostic isotope which can simultaneously be used for targeted-alpha-particle therapy and positron-emission tomography. Feasibility experiments were performed to test a near-symmetric heavy-ion reaction of 63Cu bombardment on monoisotopic 89Y. The indirect reaction was studied to avoid isomer production. Offline gamma spectroscopy was used to quantify thick-target physical yields and experimental results show modest agreement to the fusion-evaporation code PACE4. A near-symmetric fission yield was also observed.


Assuntos
Cobre/química , Radioisótopos/química , Térbio/química , Isótopos de Ítrio/química , Meia-Vida , Espectrometria gama
8.
Appl Radiat Isot ; 157: 109023, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32063336

RESUMO

As part of an effort to develop aqueous isotope harvesting techniques at radioactive beam facilities, 48V and a cocktail of primary- and secondary-beam ions created by the fragmentation reaction of a 160 MeV/nucleon 58Ni beam were stopped in an aqueous target cell. After collection, 48V was separated from the mixture of beam ions using cation-exchange chromatography. The extraction efficiency from the aqueous solution was (47.0 ± 2.5)%, and the isolated 48V had a radiochemical purity of 95.8%. This proof-of-concept work shows that aqueous isotope harvesting could provide significant quantities of rare isotopes which are currently unavailable at conventional facilities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA