Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Pharm Biomed Anal ; 48(5): 1397-403, 2008 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-18996667

RESUMO

Recent studies have shown a correlation between 5-lipoxygenase (5-LO) pathway up-regulation and cardiovascular risk. Despite the existence of several assays for products of the 5-LO pathway, a reliable method for clinical determination of 5-LO activity remains to be established. In the present communication, we report conditions that allow measurement of 5-hydroxyeicosatetraenoic acid (5-HETE) and leukotriene B(4) (LTB(4)) in peripheral blood mononuclear cells (PBMCs) isolated from the blood of atherosclerosis patients before and after stimulation by the calcium ionophore, A23187. LTB(4), a potent mediator of inflammation-linked cardiovascular disease, was measured using an existing competitive enzyme immunoassay (EIA) kit after making specific methodological improvements that allowed PBMCs to be used in this format for the first time. LTB(4) was also measured by LC/MS/MS along with 5-HETE, a direct by-product of the action of 5-LO on arachidonic acid and a molecule for which no commercial EIA kit exists. The LC/MS/MS assay was validated over a range of 0.025-25ng/mL for LTB(4) and 0.1-25ng/mL for 5-HETE. The EIA method has a validated range covering 0.025-4ng/mL. When both assays were applied to analyze LTB(4) from stimulated PBMCs isolated from 25 subjects with various degrees of atherosclerosis, a high correlation was obtained (r=0.9426, Pearson's correlation coefficient). A high correlation was also observed between the levels of LTB(4) and 5-HETE measured by LC/MS/MS after ionophore stimulation (r=0.9159). Details are presented for optimized sample collection, processing, storage, and analysis in accordance with the logistical demands of clinical analysis.


Assuntos
Araquidonato 5-Lipoxigenase/sangue , Araquidonato 5-Lipoxigenase/metabolismo , Técnicas Imunoenzimáticas/métodos , Leucócitos Mononucleares/enzimologia , Araquidonato 5-Lipoxigenase/genética , Calcimicina/metabolismo , Calcimicina/farmacologia , Cromatografia Líquida , Humanos , Ácidos Hidroxieicosatetraenoicos/genética , Ácidos Hidroxieicosatetraenoicos/metabolismo , Ionóforos/metabolismo , Ionóforos/farmacologia , Leucotrieno B4/análise , Leucotrieno B4/genética , Leucotrieno B4/metabolismo , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Temperatura , Fatores de Tempo
2.
J Clin Lipidol ; 10(3): 519-527.e4, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27206939

RESUMO

BACKGROUND: Potent CETP inhibitors reduce plasma concentrations of atherogenic lipoprotein biomarkers of cardiovascular risk. OBJECTIVES: To evaluate the effects of the cholesteryl ester transfer protein (CETP) inhibitor evacetrapib, as monotherapy or with statins, on atherogenic apolipoprotein B (apoB)-containing lipoproteins in mildly hypercholesterolemic patients. METHODS: VLDL and LDL particle concentrations and sizes (using nuclear magnetic resonance spectroscopy) and lipoprotein(a) concentration (using nephelometry) were measured at baseline and week 12 in a placebo-controlled trial of 393 patients treated with evacetrapib as monotherapy (30 mg/d, 100 mg/d, or 500 mg/d) or in combination with statins (100 mg plus simvastatin 40 mg/d, atorvastatin 20 mg/d, or rosuvastatin 10 mg/d; Clinicaltrials.gov Identifier: NCT01105975). RESULTS: Evacetrapib monotherapy resulted in significant placebo-adjusted dose-dependent decreases from baseline in Lp(a) (up to -40% with evacetrapib 500 mg), total LDL particle (LDL-P) (up to -54%), and small LDL particle (sLDL) (up to -95%) concentrations. Compared to statin alone, coadministration of evacetrapib and statins also resulted in significant reduction from baseline in Lp(a) (-31%), LDL-P (-22%), and sLDL (-60%) concentrations. The percentage of patients with concentrations above optimal concentrations for LDL-P (>1000 nmol/L) and sLDL (>600 nmol/L) decreased from 88% and 55% at baseline, respectively, to 20% and 12% at week 12, for patients treated with evacetrapib plus statins. Evacetrapib, alone or with statins, significantly increased LDL-P size. CONCLUSIONS: Evacetrapib, as monotherapy or with statins, significantly reduces the concentrations of atherogenic apoB-containing lipoproteins, including Lp(a), LDL-P, and sLDL.


Assuntos
Benzodiazepinas/farmacologia , LDL-Colesterol/sangue , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Hipercolesterolemia/sangue , Hipercolesterolemia/tratamento farmacológico , Lipoproteína(a)/sangue , Tamanho da Partícula , Benzodiazepinas/uso terapêutico , LDL-Colesterol/química , Interações Medicamentosas , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade
3.
J Pharm Biomed Anal ; 39(3-4): 685-90, 2005 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-15927431

RESUMO

The double antigen bridging immunoassay has been used extensively for detection of immunogenicity responses to therapeutic monoclonal antibodies. We have analyzed parameters affecting performance of this type of immunoassay including microtiter plate antigen coating concentration, enzyme-labeled antigen conjugate dilution and assay format (one-step versus two-step). We present results demonstrating that the format of the assay has a significant impact on the optimal parameters to maximize assay performance. A one-step assay format achieves maximal sensitivity across a broad range of coating concentrations and at a lower concentration of conjugate than that in a two-step format. In contrast, a two-step format requires very low coating concentrations and higher conjugate concentrations to achieve maximal sensitivity and suffers from significantly reduced sensitivity at higher coating concentrations. Together, these findings indicate that a one-step assay format can greatly reduce the effect of coating concentration variation on assay performance.


Assuntos
Anticorpos Monoclonais/química , Antígenos/química , Ensaio de Imunoadsorção Enzimática/instrumentação , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos Monoclonais/imunologia , Afinidade de Anticorpos , Antígenos/análise , Sítios de Ligação de Anticorpos , Ligação Competitiva , Relação Dose-Resposta a Droga , Peroxidase do Rábano Silvestre/análise , Humanos , Técnicas Imunoenzimáticas/métodos , Imunoglobulina G/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura
4.
J Pharm Biomed Anal ; 36(5): 1037-44, 2005 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-15620530

RESUMO

Quantification of biomarkers can provide important information about the safety and efficacy of candidate drugs. Unfortunately, limited sample volume and excess costs often limit analysis of multiple biomarkers. We developed, optimized, validated, and implemented a multiplex immunoassay for simultaneous measurement of multiple circulating cytokines: IL-1beta, TNFalpha, IL-6, IL-8, and IL-10. Multiplex immuoassays were performed using the Luminex LabMAP instrument. Capture antibodies for each cytokine were covalently bound to distinct microsphere subsets distinguished by differing dye ratios. The concentration of each individual cytokine determined by measuring orange fluorescence produced by a complex of a biotinylated cytokine-specific antibody and streptavidin-phycoerythrin. The lower limit of quantification for all assays was 20 pg/mL with the exception of IL-8 which was 100 pg/mL. The inter-assay precision was less than 25%CV for all analytes at all control levels both pre-study and in-study. The percent recovery ranged from 83 to 108% pre-study and 90 to 125% in-study. In a linearity assessment, a 15,000 pg/mL multi-analyte control could be diluted 1:50 and maintain expected accuracy. We measured the cytokine concentrations in more than 2000 serum samples from patients with sepsis. Multiplex results for IL-6 were compared to a conventional commercially available ELISA kit. The degree of agreement between the two methods as measured by the concordance correlation coefficient was 84.5%. Multiplex results were 2.36-fold higher than ELISA values on the average. After adjusting for this mean difference, the 95% empirical limits of agreement for the ratio of individual sample values were 0.33, 2.65. This multiplex immunoassay provided simultaneous measurement of circulating cytokines using 80% less patient specimen compared to traditional approaches and at a significantly decreased cost. Efficient use of this platform requires process improvements to fully maximize the positive impact of multiplex assays in clinical drug development.


Assuntos
Citocinas/sangue , Humanos , Imunoensaio/métodos , Imunoensaio/normas
5.
Lipids ; 45(8): 757-64, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20640528

RESUMO

ATP-binding cassette transporter A-1 (ABCA1) mediates the transfer of cellular cholesterol to lipid-poor apolipoproteins. Liver X receptors (LXRs) are regulators of cholesterol homeostasis that increase transcription of ABCA1. Synthetic LXR agonists developed to date have been shown to induce ABCA1 mRNA expression and increase reverse cholesterol transport. Unfortunately, there have been few options for quantitatively measuring ABCA1 protein levels, including a previously described competitive ELISA standardized to an ABCA1 peptide with a sensitivity of 80 ng/ml. To address this unmet need, we developed a novel sandwich ELISA standardized to full-length human recombinant ABCA1 protein with sensitivity of approximately 0.5 ng/ml. To determine if the sandwich ELISA had adequate sensitivity to detect LXR-induced increases in ABCA1, we utilized it to measure ABCA1 levels in untreated and LXR agonist-treated human (THP-1) macrophage cells and human peripheral blood mononuclear cells (PBMC). Data obtained from the ELISA demonstrated an approximately eightfold increase in ABCA1 levels in both macrophages as well as PBMC in response to LXR agonist treatment, and results were highly correlated with those obtained by immunoprecipitation and western blotting. Together, these results suggest that the sandwich ELISA may be a sensitive and effective method for quantitating ABCA1 protein levels.


Assuntos
Transportadores de Cassetes de Ligação de ATP/análise , Ensaio de Imunoadsorção Enzimática/métodos , Transportador 1 de Cassete de Ligação de ATP , Transportadores de Cassetes de Ligação de ATP/metabolismo , Western Blotting , Linhagem Celular , Células Cultivadas , Humanos , Imunoprecipitação , Leucócitos Mononucleares/metabolismo , Macrófagos/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA