Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Physiol ; 600(7): 1791-1806, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35060129

RESUMO

In Australia, a significant proportion of stillbirths remain unexplained. Recent research has highlighted nocturnal maternal behaviours as potentially modifiable contributors. This study determined whether sleep-related behaviours including sleep position and sleep-disordered breathing adversely affect fetuses overnight, in both uncomplicated pregnancies and those at increased risk due to hypertensive disorders or fetal growth restriction (FGR). All participants underwent polysomnography with time-synchronized fetal heart rate (FHR) monitoring (cardiotocography - CTG) in late pregnancy. CTGs were analysed for abnormal FHR events, including decelerations and reduced variability, by two blinded observers and exported into the sleep study to temporally align FHR events with sleep behaviours. For each FHR event, 10 control epochs with normal FHR were randomly selected for the same participant. Conditional logistic regression assessed the relationships between FHR events and sleep behaviours. From 116 participants, 52 had a total of 129 FHR events overnight; namely prolonged decelerations and prolonged periods of reduced variability. Significantly more FHR events were observed in women with FGR and/or a hypertensive disorder compared with uncomplicated pregnancies (P = 0.006). FHR events were twice as likely to be preceded by a change in body position within the previous 5 min, compared with control epochs (P = 0.007), particularly in hypertensive pregnancies both with and without FGR. Overall, FHR events were not temporally related to supine body position, respiratory events or snoring. Our results indicate that most fetuses tolerate sleep-related stressors, but further research is needed to identify the interplay of maternal and fetal conditions putting the fetus at risk overnight. KEY POINTS: Maternal sleep behaviours including supine position and sleep-disordered breathing are potential contributors to stillbirth but much of this work is based on self-reported data. Using time-synchronized polysomnography and cardiotocography, we found that nocturnal fetal heart rate decelerations were more likely to be preceded by a change in body position compared with epochs containing normal fetal heart rate, particularly in hypertensive pregnancies with or without fetal growth restriction. There was no temporal relationship between maternal sleeping position, snoring or apnoeic events and an abnormal fetal heart rate overnight. We conclude that most fetuses can tolerate sleep-related stressors with no evidence of fetal heart rate changes indicating compromised wellbeing. Further work needs to identify how sleep behaviours contribute to stillbirth risk and how these intersect with underlying maternal and fetal conditions.


Assuntos
Cardiotocografia , Frequência Cardíaca Fetal , Feminino , Retardo do Crescimento Fetal , Feto , Frequência Cardíaca , Frequência Cardíaca Fetal/fisiologia , Humanos , Gravidez , Sono
2.
BJOG ; 129(13): 2185-2194, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35445795

RESUMO

OBJECTIVES: To evaluate fetal heart rate (FHR) patterns during sleep in pregnancies complicated by preterm fetal growth restriction (FGR). To determine whether co-existing sleep-disordered breathing (SDB) impacts on acute FHR events or perinatal outcome. DESIGN: Observational case control study. SETTING AND POPULATION: Women with preterm FGR and gestation-matched well grown controls (estimated fetal weight above the 10th percentile with normal Doppler studies); tertiary maternity hospital, Australia. METHODS: A polysomnogram, a test used to measure sleep patterns and diagnose sleep disorders, and concurrent cardiotocography (CTG), were analysed for respiratory events and FHR changes. MAIN OUTCOME MEASURES: Frequency of FHR events overnight in FGR cases versus controls and in those with or without SDB. RESULTS: Twenty-nine patients with preterm FGR and 29 controls (median estimated fetal weight 1st versus 60th percentile, P < 0.001) underwent polysomnography with concurrent CTG at a mean gestation of 30.2 weeks. The median number of FHR events per night was higher among FGR cases than among controls (3.0 events, interquartile range [IQR] 1.0-4.0, versus 1.0 [IQR 0-1.0]; P < 0.001). Women with pregnancies complicated by preterm FGR were more likely than controls to be nulliparous, receive antihypertensive medications, be supine at sleep onset, and to sleep supine (32.9% of total sleep time versus 18.3%, P = 0.03). SDB was common in both FGR and control pregnancies (48% versus 38%, respectively, P = 0.55) but was generally mild and not associated with an increase in overnight FHR events or adverse perinatal outcome. CONCLUSIONS: Acute FHR events overnight are more common in pregnancies complicated by preterm FGR than in pregnancies with normal fetal growth. Mild SDB was common in late pregnancy and well tolerated, even by fetuses with preterm FGR. TWEETABLE ABSTRACT: Mild sleep-disordered breathing seems well tolerated even by highly vulnerable fetuses.


Assuntos
Retardo do Crescimento Fetal , Síndromes da Apneia do Sono , Recém-Nascido , Feminino , Gravidez , Humanos , Retardo do Crescimento Fetal/diagnóstico , Frequência Cardíaca Fetal/fisiologia , Peso Fetal , Estudos de Casos e Controles , Parto , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Sono , Ultrassonografia Pré-Natal , Idade Gestacional
3.
J Sleep Res ; 27(5): e12656, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29368415

RESUMO

Sleep-disordered breathing is more common in hypertensive disorders during pregnancy; however, most studies have not adequately accounted for the potential confounding impact of obesity. This study evaluated the frequency of sleep-disordered breathing in women with gestational hypertension and pre-eclampsia compared with body mass index- and gestation-matched normotensive pregnant women. Women diagnosed with gestational hypertension or pre-eclampsia underwent polysomnography shortly after diagnosis. Normotensive controls body mass index-matched within ±4 kg m-2 underwent polysomnography within ±4 weeks of gestational age of their matched case. The mean body mass index and gestational age at polysomnography were successfully matched for 40 women with gestational hypertension/pre-eclampsia and 40 controls. The frequency of sleep-disordered breathing in the cases was 52.5% compared with 37.5% in the control group (P = 0.18), and the respiratory disturbance index overall did not differ (P = 0.20). However, more severe sleep-disordered breathing was more than twice as common in women with gestational hypertension or pre-eclampsia (35% versus 15%, P = 0.039). While more than half of women with a hypertensive disorder of pregnancy meet the clinical criteria for sleep-disordered breathing, it is also very common in normotensive women of similar body mass index. This underscores the importance of adjusting for obesity when exploring the relationship between sleep-disordered breathing and hypertension in pregnancy. More severe degrees of sleep-disordered breathing are significantly associated with gestational hypertension and pre-eclampsia, and sleep-disordered breathing may plausibly play a role in the pathophysiology of pregnancy hypertension in these women. This suggests that more severe sleep-disordered breathing is a potential therapeutic target for reducing the prevalence or severity of hypertensive disorders in pregnancy.


Assuntos
Hipertensão Induzida pela Gravidez/fisiopatologia , Complicações na Gravidez/diagnóstico , Síndromes da Apneia do Sono/etiologia , Adulto , Índice de Massa Corporal , Estudos Transversais , Feminino , Humanos , Gravidez , Síndromes da Apneia do Sono/fisiopatologia
4.
J Clin Sleep Med ; 20(5): 709-717, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38169424

RESUMO

STUDY OBJECTIVES: The oxygen desaturation index (ODI) is an important measure of sleep-disordered breathing during polysomnography (PSG); however, the AASM Manual (V3) does not specify whether to include oxygen desaturations occurring during wake epochs. Additionally, an ODI obtained from PSG can differ from an ODI using home sleep apnea tests (HSATs) that do not measure sleep, hampering diagnostic and treatment decision reliability. This study aimed to (1) compare an ODI that included all desaturations with an ODI that excluded desaturations occurring during wake epochs in PSG and (2) compare ODIs obtained from PSG with HSAT. METHODS: 100 consecutive PSGs for investigation of obstructive sleep apnea were compared. ODIs were calculated including all desaturations (ODIall) and by excluding desaturations entirely during wake epochs (ODIsleep). Additionally, we compared ODIall with an ODI calculated using monitoring time as the denominator (ODIHSAT). RESULTS: The median (interquartile range) 3% ODI for ODIall was 22.8 (13.1, 44.1) events/h and ODIsleep was 17.6 (11.5, 35.2) events/h (median difference: -3.9 events/h [-8.2, -0.9]; 21.0% [8.7%, 33.2%]). This discrepancy was larger with increasing ODI and decreasing sleep efficiency. The ODIHSAT was 17.4 (11.3, 35.2) events/h and the median reduction in ODIHSAT vs ODIall was -4.5 (-10.9, -2.0) events/h (21.6%; 11.1%, 33.8). CONCLUSIONS: ODI was significantly reduced when desaturations in wake epochs were excluded, and when ODI was based on monitoring time rather than sleep time, with the potential for underestimation of disease severity. Results suggest that ODI can differ substantially depending on the calculation and study type used, and that there is a need for standardization to ensure consistent diagnosis and treatment outcomes. CITATION: Whenn CB, Wilson DL, Ruehland WR, Churchward TJ, Worsnop C, Tolson J. The impact of study type and sleep measurement on oxygen desaturation index calculation. J Clin Sleep Med. 2024;20(5):709-717.


Assuntos
Polissonografia , Apneia Obstrutiva do Sono , Humanos , Polissonografia/métodos , Polissonografia/estatística & dados numéricos , Masculino , Feminino , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Reprodutibilidade dos Testes , Saturação de Oxigênio/fisiologia , Adulto , Oxigênio/sangue , Sono/fisiologia
5.
J Sleep Res ; 22(6): 670-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23745721

RESUMO

Sleep-disordered breathing (SDB) is reported commonly during pregnancy and is associated with an increased risk of adverse maternal and fetal outcomes, but the majority of these data are based upon self-report measures not validated for pregnancy. This study examined the predictive value of screening questionnaires for SDB administered at two time-points in pregnancy, and attempted to develop an 'optimized predictive model' for detecting SDB in pregnancy. A total of 380 women were recruited from an antenatal clinic in the second trimester of pregnancy. All participants completed the Berlin Questionnaire and the Multivariable Apnea Risk Index (MAP Index) at recruitment, with a subset of 43 women repeating the questionnaires at the time of polysomnography at 37 weeks' gestation. Fifteen of 43 (35%) women were confirmed to have a respiratory disturbance index (RDI) > 5 h(-1) . Prediction of an RDI > 5 h(-1) was most accurate during the second trimester for both the Berlin Questionnaire (sensitivity 0.93, specificity 0.50, positive predictive value 0.50 and negative predictive value 0.93), and the MAP Index [area under the receiver operating characteristic (ROC) curve of 0.768]. A stepwise selection model identified snoring volume, a body mass index (BMI)≥32 kg m(-2) and tiredness upon awakening as the strongest independent predictors of SDB during pregnancy; this model had an area under the ROC curve of 0.952. We conclude that existing clinical prediction models for SDB perform inadequately as a screening tool in pregnancy. The development of a highly predictive model from our data shows promise for a quick and easy screening tool to be validated for future use in pregnancy.


Assuntos
Complicações na Gravidez/diagnóstico , Síndromes da Apneia do Sono/diagnóstico , Adulto , Índice de Massa Corporal , Estudos de Coortes , Feminino , Humanos , Modelos Logísticos , Programas de Rastreamento , Polissonografia , Valor Preditivo dos Testes , Gravidez , Complicações na Gravidez/fisiopatologia , Segundo Trimestre da Gravidez , Curva ROC , Risco , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/fisiopatologia , Ronco/complicações , Ronco/diagnóstico , Inquéritos e Questionários , Adulto Jovem
6.
Behav Sleep Med ; 11(3): 207-21, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23205562

RESUMO

This study compared self-reported sleep latency (SL) and total sleep time (TST) to objective measures on polysomnography (PSG) during pregnancy. Thirty-three women in the third trimester (T3) of pregnancy, 16 women in the first trimester (T1) of pregnancy, and 15 non-pregnant women underwent overnight PSG, and shortly after awakening reported their perceived SL and TST. Results showed that, on average, the T3 group slightly overestimated their TSTs, whereas the T1 and non-pregnant groups underestimated TSTs when compared with objective measurement. All groups overestimated SL, and perceived SL was closest to the first epoch of 10 min of uninterrupted sleep or the first epoch of slow-wave sleep, rather than the first epoch of sleep (the current definition used for diagnostic sleep studies). The wide variation in discrepancies between estimation and PSG measurement for both TST and SL shows that self-reports made by both pregnant and non-pregnant women tend to be unreliable, which has important implications both clinically and for the many studies based on self-reported sleep patterns in pregnancy.


Assuntos
Polissonografia , Primeiro Trimestre da Gravidez/fisiologia , Terceiro Trimestre da Gravidez/fisiologia , Gravidez/fisiologia , Autorrelato , Sono/fisiologia , Adulto , Feminino , Humanos
7.
Breastfeed Med ; 18(12): 951-955, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38100440

RESUMO

Background and Objective: There is a question as to whether melatonin levels in breast milk are impacted by the cooling rate postpasteurization. Past research that has used in the Australian donor bank's breast milk Holder Pasteurization technique has reported varying findings regarding melatonin levels postpasteurization. Where breast milk was cooled slowly, a significant reduction in breast milk melatonin levels was observed. Conversely, where a rapid cooling method was used, there was no significant reduction in melatonin levels. The aim of this study was to investigate whether the cooling process between the different pasteurization techniques impact on melatonin levels in breast milk postpasteurization. Materials and Methods: Twenty-seven nighttime breast milk samples were collected, with each sample divided into three; one remained unpasteurized, one was pasteurized and rapidly cooled to 4°C, and the other was pasteurized and cooled slowly to 4°C. Results: Melatonin levels were significantly reduced in both the rapidly cooled and slow cooled breast milk samples when compared to their unpasteurized counterpart (p < 0.001). There was no significant difference in melatonin levels between the two cooling methods (p = 0.91). Conclusion: This study showed that both the rapid and cooling pasteurization processes had a similar reduction in melatonin levels in breast milk. However, even after pasteurization melatonin was still present. Therefore, it is recommended that donor banks still take into consideration circadian timing hormones such as melatonin and the time of day breast milk is expressed.


Assuntos
Melatonina , Bancos de Leite Humano , Feminino , Humanos , Leite Humano , Pasteurização/métodos , Austrália , Aleitamento Materno
8.
Breastfeed Med ; 18(7): 549-552, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37257176

RESUMO

Background and Objective: Donor human milk banks are used when breast milk directly from mothers is unavailable or insufficient. Breast milk contains melatonin, which exhibits a 24-hour pattern. Melatonin promotes sleep onset and is barely detected in daytime milk but rises in the evening and peaks early in the morning. Melatonin supports the development of an infant's own circadian rhythm and is important for neurodevelopment. Currently, donor banks pasteurize breast milk using a Holder Pasteurization (HoP) technique where breast milk is treated at a high temperature (+62°) for 30 minutes before cooling to eliminate any pathogens before it is given to infants. It is not known how the pasteurization process affects the melatonin levels in breast milk. The aim of this study was to investigate whether the pasteurization process reduces melatonin levels in breast milk. Materials and Methods: Ten night-time breast milk samples were collected and each divided into two groups; one group remained unpasteurized and the other group was pasteurized using the HoP technique. Results: Melatonin levels between the unpasteurized and pasteurized groups were compared. Results showed that there was a significant reduction after pasteurization (mean ± standard deviation = 51.92 pg/mL ± 19.54 versus 39.66 pg/mL ± 13.05, p = 0.01). Conclusions: It is important to understand that pasteurization can reduce melatonin levels in breast milk because this hormone is considered important to support the neurodevelopment of infants, especially those born preterm. Further focus on the effect of pasteurization techniques on melatonin in donor breast milk is warranted.


Assuntos
Melatonina , Bancos de Leite Humano , Recém-Nascido , Lactente , Feminino , Humanos , Leite Humano , Pasteurização/métodos , Temperatura , Aleitamento Materno
9.
Sleep ; 45(4)2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35150285

RESUMO

Links between supine "going to sleep" position and stillbirth risk have led to campaigns regarding safe maternal sleep position. This study profiles the distribution of sleep positions overnight and relationships to sleep onset position during pregnancy, and the relationships between supine sleep, sleep-disordered breathing (SDB), and pregnancy outcomes. Data from three prospective cohort studies evaluating SDB in healthy and complicated pregnancies were pooled. All participants underwent one night of polysomnography in late pregnancy and birth outcome data were collected. 187 women underwent polysomnography at a median gestation of 34 weeks'. The left lateral position was preferred for falling asleep (52%) compared to supine (14%), but sleep onset position was the dominant sleep position overnight in only half (54%) of women. The median percentage of sleep time in the supine position was 24.2%; women who fell asleep supine spent more time supine overnight compared to those who began non-supine (48.0% (30.0,65.9) vs. 22.6% (5.7,32.2), p < .001). Women with growth-restricted fetuses were more likely to fall asleep supine than those with well-grown fetuses (36.6% vs. 7.5%, p < .001). Positional SDB was observed in 46% of those with an RDI ≥ 5. Sleep onset position was the dominant position overnight for half of the sample, suggesting that sleep onset position is not always a reliable indicator of body position overnight. Supine sleep was related to fetal growth restriction and birthweight at delivery, though causality cannot be inferred. It is critical that we pursue research into verifying the important relationship between supine sleep and increased stillbirth risk, and the mechanisms behind it.


Assuntos
Complicações na Gravidez , Síndromes da Apneia do Sono , Feminino , Humanos , Gravidez , Complicações na Gravidez/epidemiologia , Estudos Prospectivos , Sono , Síndromes da Apneia do Sono/complicações , Natimorto/epidemiologia , Decúbito Dorsal
10.
J Matern Fetal Neonatal Med ; 35(13): 2545-2554, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32669005

RESUMO

INTRODUCTION: An association between the increased risk of late stillbirth and the maternal supine sleeping position has been recently established. The risk of stillbirth following supine sleep has been suspected to occur as a result of aortocaval compression by the gravid uterus. A number of studies conducted during wakefulness have reported compromised cardiovascular function during supine rest, as demonstrated by reductions in cardiac output, blood pressure and utero-placental blood flow. It remains unclear whether similar effects are also present during sleep, due to the presence of key sleep-specific changes in cardiovascular function. OBJECTIVE: To investigate the changes in maternal cardiovascular function between the supine and left-lateral positions during wakefulness and non-rapid eye movement (NREM) sleep in late pregnancy. METHODS: Twenty-nine women with a singleton pregnancy between 24.7 and 36.7 weeks' gestation participated in a single overnight sleep study. Physiological measures (blood pressure, heart rate, heart rate variability - HRV, and pulse arrival time - PAT) were measured and recorded throughout the night using standard polysomnography equipment and the Portapres Model-2 device. As the present study evaluated cardiovascular changes during natural rest and sleep in pregnancy, participants were not given explicit instructions on which position to adopt. Body position was continuously recorded using a position monitor and verified with video recording. RESULTS: No changes in systolic, diastolic or mean arterial blood pressure were observed between the left-lateral and supine positions during wakefulness or sleep. However, heart rate was significantly higher in the supine position compared to the left during wakefulness (p= .03), with a similar trend present during sleep (p= .11). A significantly shorter PAT was measured in the supine position (compared to the left) during wakefulness (p= .01) and sleep (p= .01). No change in HRV measures was observed between the left and supine positions in either state. CONCLUSION: Blood pressure did not appear to differ significantly between the left-lateral and supine positions during wakefulness and sleep. The lack of blood pressure differences may reflect elevated sympathetic activity during rest and sleep in the supine position (compared to the left), suggesting that some degree of compensation for aortocaval compression may still be possible during sleep.


Assuntos
Natimorto , Vigília , Feminino , Humanos , Placenta , Gravidez , Sono/fisiologia , Decúbito Dorsal/fisiologia
11.
J Clin Sleep Med ; 18(5): 1385-1393, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35022129

RESUMO

STUDY OBJECTIVES: There is an internal contradiction in current American Academy of Sleep Medicine standards for arousal index (AI) calculation in polysomnography: Arousals in sleep and wake epochs are counted, but only sleep time is used in the denominator. This study aimed to investigate the impact of including arousals scored in wake epochs on the AI. METHODS: We compared AIs including (AIinc) vs excluding (AIexc) awake-epoch arousals from 100 consecutive polysomnograms conducted for investigation of possible obstructive sleep apnea. To determine the AI that most closely approximated "truth," AIinc and AIexc were compared to an AI calculated from continuous sleep analysis (AIcont) in a 20-polysomnogram subgroup of patients. RESULTS: The median (interquartile range) increase in AIinc was 5.2 events/h (3.5-8.1) vs AIexc (AIinc = 28.0 events/h [18.4-38.9] vs AIexc = 22.9 events/ h [13.1-31.3]), equating to an increase of 25.3% (15.6-40.8). As the AI increased, the difference increased (P < .001), with decreasing sleep efficiency and an increasing apnea-hypopnea index as the strongest predictors of the difference between AIexc and AIinc. The absolute AIexc-AIcont difference (7.7 events/h [5.1-13.6]) was significantly greater than the AIinc-AIcont difference (1.2 events/h [0.6-5.7]; z = -3.099; P = .002). CONCLUSIONS: There was a notable increase in AI when we included wake-epoch arousals, particularly in patients with more severe obstructive sleep apnea or reduced sleep efficiency. However, the AI including wake-epoch arousals best matched the "true" continuous sleep-scoring AI. Our study informs clinical and research practice, highlights epoch scoring pitfalls, and supports the current American Academy of Sleep Medicine standard arousal reporting approach for future standards. CITATION: Wilson DL, Tolson J, Churchward TJ, Melehan K, O'Donoghue FJ, Ruehland WR. Exclusion of EEG-based arousals in wake epochs of polysomnography leads to underestimation of the arousal index. J Clin Sleep Med. 2022;18(5):1385-1393.


Assuntos
Nível de Alerta , Apneia Obstrutiva do Sono , Eletroencefalografia , Humanos , Polissonografia , Sono , Apneia Obstrutiva do Sono/diagnóstico
12.
Aust N Z J Obstet Gynaecol ; 51(1): 38-46, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21299507

RESUMO

BACKGROUND: Anecdotal reports of sleep disturbance during pregnancy are abundant; however, objective measurement of sleep changes has so far produced conflicting results. AIMS: To objectively measure sleep architecture and investigate subjective sleep quality in the first and third trimester of pregnancy, when compared to the nonpregnant state. METHODS: Twenty-seven women in the third trimester of pregnancy, 21 women in the first trimester of pregnancy and 24 nonpregnant control women underwent overnight polysomnography and completed questionnaires regarding sleep quality and mood. RESULTS: Women in the third trimester of pregnancy had poorer sleep efficiency, more awakenings, less stage 4 sleep, more stage 1 sleep and fewer minutes in rapid eye movement sleep when compared to the control group. Cortical arousals were seen more often during pregnancy, particularly in response to respiratory events and limb movements. Sleep during the first trimester was affected to a lesser extent, with more wake time after sleep onset and less stage 4 sleep when compared to the controls. CONCLUSIONS: Sleep during pregnancy is compromised by higher amounts of wake and cortical arousals leading to sleep fragmentation, with greater amounts of light sleep and less deep sleep. Mood state did not have an effect on sleep. Given the impact of sleep on well-being, this study increases our understanding of the characteristics of sleep during pregnancy, to help recognise when severe sleep disruption may warrant referral to a specialist for appropriate diagnosis and treatment.


Assuntos
Córtex Cerebral/fisiopatologia , Complicações na Gravidez/fisiopatologia , Terceiro Trimestre da Gravidez/fisiologia , Transtornos do Despertar do Sono/fisiopatologia , Distúrbios do Início e da Manutenção do Sono/fisiopatologia , Sono/fisiologia , Adulto , Nível de Alerta/fisiologia , Feminino , Humanos , Polissonografia , Gravidez , Primeiro Trimestre da Gravidez/fisiologia , Fases do Sono/fisiologia , Sono REM/fisiologia , Vigília/fisiologia
13.
PLoS One ; 15(4): e0232287, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32339208

RESUMO

OBJECTIVE: Sleep-disordered breathing (SDB) is characterised by intermittent hypoxemia, sympathetic activation and widespread endothelial dysfunction, sharing pathophysiologic features with the hypertensive disorders of pregnancy. We sought to determine whether coexisting SDB would adversely impact the outcomes of women with gestational hypertension (GH) and preeclampsia (PE), and healthy matched controls. STUDY DESIGN: Women diagnosed with GH or PE along with BMI- and gestation-matched normotensive controls underwent polysomnography in late pregnancy to establish the presence or absence of SDB (RDI ≥ 5). Clinical outcomes of hypertensive disease severity were compared between groups, and venous blood samples were taken in the third trimester and at delivery to examine for any impact of SDB on the anti-angiogenic markers of PE. RESULTS: Data was available for 17 women with PE, 24 women with GH and 44 controls. SDB was diagnosed in 41% of the PE group, 63% of the GH group and 39% of the control group. Women with PE and co-existing SDB did not have worse outcomes in terms of gestation at diagnosis of PE (SDB = 29.1 (25.9, 32.1) weeks vs. no SDB = 32.0 (29.0, 33.9), p = n.s.) and days between diagnosis of PE and delivery (SDB = 20.0 (4.0, 35.0) days vs. no SDB = 10.5 (9.0, 14.0), p = n.s.). There were also no differences in severity of hypertension, antihypertensive treatment and biochemical, haematological and anti-angiogenic markers of PE between SDB and no SDB groups. Similar results were observed among women with GH. Healthy control women with SDB were no more likely to develop a hypertensive disorder of pregnancy in the later stages of pregnancy (SDB = 5.9% vs. no SDB = 7.4%, p = n.s.). Increasing the threshold for diagnosis of SDB to RDI ≥ 15 did not unmask a worse prognosis. CONCLUSION: The presence of SDB during pregnancy did not worsen the disease course of GH or PE, and was not associated with high blood pressure or anti-angiogenic markers of hypertensive disease amongst healthy pregnant women. Given the numerous reports of the relationship between SDB and diagnosis of hypertensive disorders of pregnancy, it appears more work is required to distinguish causal, versus confounding, pathways.


Assuntos
Hipertensão Induzida pela Gravidez/etiologia , Hipertensão Induzida pela Gravidez/fisiopatologia , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/fisiopatologia , Adulto , Anti-Hipertensivos/uso terapêutico , Feminino , Humanos , Hipertensão Induzida pela Gravidez/tratamento farmacológico , Hipertensão Induzida pela Gravidez/metabolismo , Fator de Crescimento Placentário/metabolismo , Polissonografia/métodos , Pré-Eclâmpsia/metabolismo , Pré-Eclâmpsia/fisiopatologia , Gravidez , Fatores de Risco , Síndromes da Apneia do Sono/metabolismo
14.
PLoS One ; 15(2): e0229568, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32101584

RESUMO

OBJECTIVE: To determine whether the presence of co-existing sleep-disordered breathing (SDB) is associated with worse perinatal outcomes among women diagnosed with a hypertensive disorder of pregnancy (HDP), compared with normotensive controls. STUDY DESIGN: Women diagnosed with HDP (gestational hypertension or preeclampsia) and BMI- and gestation-matched controls underwent polysomnography in late pregnancy to determine if they had coexisting SDB. Fetal heart rate (FHR) monitoring accompanied the sleep study, and third trimester fetal growth velocity was assessed using ultrasound. Cord blood was taken at delivery to measure key regulators of fetal growth. RESULTS: SDB was diagnosed in 52.5% of the HDP group (n = 40) and 38.1% of the control group (n = 42); p = .19. FHR decelerations were commonly observed during sleep, but the presence of SDB did not increase this risk in either the HDP or control group (HDP group-SDB = 35.3% vs. No SDB = 40.0%, p = 1.0; control group-SDB = 41.7% vs. No SDB = 25.0%, p = .44), nor did SDB affect the total number of decelerations overnight (HDP group-SDB = 2.7 ± 1.0 vs. No SDB = 2.8 ± 2.1, p = .94; control group-SDB = 2.0 ± 0.8 vs. No SDB = 2.0 ± 0.7, p = 1.0). Fetal growth restriction was the strongest predictor of fetal heart rate events during sleep (aOR 5.31 (95% CI 1.26-22.26), p = .02). The presence of SDB also did not adversely affect fetal growth; in fact among women with HDP, SDB was associated with significantly larger customised birthweight centiles (43.2% ± 38.3 vs. 16.2% ± 27.0, p = .015) and fewer growth restricted babies at birth (30% vs. 68.4%, p = .026) compared to HDP women without SDB. There was no impact of SDB on measures of fetal growth for the control group. Cord blood measures of fetal growth did not show any adverse effect among women with SDB, either in the HDP or control group. CONCLUSION: We did not find that the presence of mild SDB worsened fetal acute or longitudinal outcomes, either among women with HDP or BMI-matched normotensive controls. Unexpectedly, we found the presence of SDB conferred a better prognosis in HDP in terms of fetal growth. The fetus has considerable adaptive capacity to withstand in utero hypoxia, which may explain our mostly negative findings. In addition, SDB in this cohort was mostly mild. It may be that fetal sequelae will only be unmasked in the setting of more severe degrees of SDB and/or underlying placental disease.


Assuntos
Hipertensão Induzida pela Gravidez/fisiopatologia , Resultado da Gravidez/epidemiologia , Síndromes da Apneia do Sono/fisiopatologia , Adulto , Austrália , Peso ao Nascer , Estudos de Coortes , Feminino , Desenvolvimento Fetal/fisiologia , Retardo do Crescimento Fetal/metabolismo , Frequência Cardíaca Fetal/fisiologia , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional/metabolismo , Recém-Nascido Pequeno para a Idade Gestacional/fisiologia , Parto/fisiologia , Polissonografia , Pré-Eclâmpsia/fisiopatologia , Gravidez , Complicações na Gravidez/fisiopatologia , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Síndromes da Apneia do Sono/complicações
15.
PLoS One ; 8(7): e68057, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23894293

RESUMO

OBJECTIVE: The objective of this study is to determine whether obstructive sleep apnea (OSA) is associated with reduced fetal growth, and whether nocturnal oxygen desaturation precipitates acute fetal heart rate changes. STUDY DESIGN: We performed a prospective observational study, screening 371 women in the second trimester for OSA symptoms. 41 subsequently underwent overnight sleep studies to diagnose OSA. Third trimester fetal growth was assessed using ultrasound. Fetal heart rate monitoring accompanied the sleep study. Cord blood was taken at delivery, to measure key regulators of fetal growth. RESULTS: Of 371 women screened, 108 (29%) were high risk for OSA. 26 high risk and 15 low risk women completed the longitudinal study; 14 had confirmed OSA (cases), and 27 were controls. The median (interquartile range) respiratory disturbance index (number of apnoeas, hypopnoeas or respiratory related arousals/hour of sleep) was 7.9 (6.1-13.8) for cases and 2.2 (1.3-3.5) for controls (p<0.001). Impaired fetal growth was observed in 43% (6/14) of cases, vs 11% (3/27) of controls (RR 2.67; 1.25-5.7; p = 0.04). Using logistic regression, only OSA (OR 6; 1.2-29.7, p = 0.03) and body mass index (OR 2.52; 1.09-5.80, p = 0.03) were significantly associated with impaired fetal growth. After adjusting for body mass index on multivariate analysis, the association between OSA and impaired fetal growth was not appreciably altered (OR 5.3; 0.93-30.34, p = 0.06), although just failed to achieve statistical significance. Prolonged fetal heart rate decelerations accompanied nocturnal oxygen desaturation in one fetus, subsequently found to be severely growth restricted. Fetal growth regulators showed changes in the expected direction- with IGF-1 lower, and IGFBP-1 and IGFBP-2 higher- in the cord blood of infants of cases vs controls, although were not significantly different. CONCLUSION: OSA may be associated with reduced fetal growth in late pregnancy. Further evaluation is warranted to establish whether OSA may be an important contributor to adverse perinatal outcome, including stillbirth.


Assuntos
Desenvolvimento Fetal/fisiologia , Complicações na Gravidez/etiologia , Apneia Obstrutiva do Sono/fisiopatologia , Adulto , Feminino , Frequência Cardíaca Fetal/fisiologia , Humanos , Gravidez , Complicações na Gravidez/metabolismo , Estudos Prospectivos , Apneia Obstrutiva do Sono/metabolismo
16.
J Clin Exp Neuropsychol ; 33(6): 680-91, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21409694

RESUMO

This study investigated episodic and procedural memory performance in early and late pregnancy. Twenty-six women in the third trimester of pregnancy, 20 women in the first trimester of pregnancy, and 24 nonpregnant controls were administered a battery of verbal and visual episodic memory tasks and two procedural memory tasks. Results indicated that compared to controls, both pregnant groups had reduced scores on immediate and delayed verbal episodic memory tasks, but were unimpaired on visual and procedural memory tasks. Verbal memory differences could not be accounted for by mood state or attention; however, progesterone level accounted for a small amount of the variation. Although memory differences were minor, the perception of memory problems may have implications for everyday living for pregnant women.


Assuntos
Atenção/fisiologia , Memória Episódica , Primeiro Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Aprendizagem Verbal/fisiologia , Estimulação Acústica , Adulto , Análise de Variância , Feminino , Humanos , Testes Neuropsicológicos , Gravidez , Complicações na Gravidez , Primeiro Trimestre da Gravidez/fisiologia , Primeiro Trimestre da Gravidez/psicologia , Terceiro Trimestre da Gravidez/fisiologia , Terceiro Trimestre da Gravidez/psicologia , Escalas de Graduação Psiquiátrica , Valores de Referência , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA