Eye (Lond) ; 37(16): 3360-3366, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37076687

RESUMO

PURPOSE: To evaluate if anterior chamber depth (ACD) and lens thickness (LT) measured by two different devices are affected by different eye lengths. METHODS: ACD and LT of 251 eyes (44 hyperopic, 60 myopic, 147 emmetropic) of 173 patients received with an iOCT-guided femtosecond laser-assisted lens surgery (FLACS) and the IOL Master 700 were compared. RESULTS: ACD measured with the IOL Master 700 was -0.026 ± 0.125 mm smaller (p = 0.001) than that with the iOCT for all eye-groups (hyperopic: p = 0.601, emmetropic: p = 0.003; myopic: p = 0.094). However, differences in all groups were not clinically relevant. LT measurements (all eyes: -0.0642 ± 0.0504 mm) shows a statistically significant difference in all evaluated groups (p < 0.001). Only myopic eyes showed a clinically relevant difference in LT. CONCLUSION: The two devices show no clinically relevant differences in the eye-length groups (myopic, emmetropic, and hyperopic) for all ACD measurements. LT data shows a clinically relevant difference only for the group of myopic eyes.


Assuntos
Hiperopia , Miopia , Humanos , Refração Ocular , Tomografia de Coerência Óptica , Miopia/cirurgia , Emetropia , Hiperopia/cirurgia