Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Transl Med ; 20(1): 557, 2022 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-36463222

RESUMO

BACKGROUND: Lymph node metastasis (LNM) is one of the most important factors affecting the prognosis of breast cancer. The accurate evaluation of lymph node status is useful to predict the outcomes of patients and guide the choice of cancer treatment. However, there is still lack of a low-cost non-invasive method to assess the status of axillary lymph node (ALN). Gene expression signature has been used to assess lymph node metastasis status of breast cancer. In addition, nucleosome footprint of cell-free DNA (cfDNA) carries gene expression information of its original tissues, so it may be used to evaluate the axillary lymph node status in breast cancer. METHODS: In this study, we found that the cfDNA nucleosome footprints between the ALN-positive patients and ALN-negative patients showed different patterns by implementing whole-genome sequencing (WGS) to detect 15 ALN-positive and 15 ALN-negative patients. In order to further evaluate its potential for assessing ALN status, we developed a classifier with multiple machine learning models by using 330 WGS data of cfDNA from 162 ALN-positive and 168 ALN-negative samples to distinguish these two types of patients. RESULTS: We found that the promoter profiling between the ALN-positive patients and ALN-negative patients showed distinct patterns. In addition, we observed 1071 genes with differential promoter coverage and their functions were closely related to tumorigenesis. We found that the predictive classifier based on promoter profiling with a support vector machine model, named PPCNM, produced the largest area under the curve of 0.897 (95% confidence interval 0.86-0.93). CONCLUSIONS: These results indicate that promoter profiling can be used to distinguish ALN-positive patients from ALN-negative patients, which may be helpful to guide the choice of cancer treatment.


Assuntos
Neoplasias da Mama , Ácidos Nucleicos Livres , Humanos , Feminino , Neoplasias da Mama/genética , Metástase Linfática/genética , Nucleossomos , Linfonodos , Ácidos Nucleicos Livres/genética
2.
Am J Obstet Gynecol ; 224(3): 300.e1-300.e9, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32871130

RESUMO

BACKGROUND: Noninvasive monitoring of fetal development and the early detection of pregnancy-associated complications is challenging, largely because of the lack of information about the molecular spectrum during pregnancy. Recently, cell-free DNA in plasma was found to reflect the global nucleosome footprint and status of gene expression and showed potential for noninvasive health monitoring during pregnancy. OBJECTIVE: We aimed to test the relationships between plasma cell-free DNA profiles and pregnancy biology and evaluate the use of a cell-free DNA profile as a noninvasive method for physiological and pathologic status monitoring during pregnancy. STUDY DESIGN: We used genome cell-free DNA sequencing data generated from noninvasive prenatal testing in a total of 2937 pregnant women. For each physiological and pathologic condition, features of the cell-free DNA profile were identified using the discovery cohort, and support vector machine classifiers were built and evaluated using independent training and validation cohorts. RESULTS: We established nucleosome occupancy profiles at transcription start sites in different gestational trimesters, demonstrated the relationships between gene expression and cell-free DNA coverage at transcription start sites, and showed that the cell-free DNA profiles at transcription start sites represented the biological processes of pregnancy. In addition, using cell-free DNA data, nucleosome profiles of transcription factor binding sites were identified to reflect the transcription factor footprint, which may help to reveal the molecular mechanisms underlying pregnancy. Finally, by using machine-learning models on low-coverage noninvasive prenatal testing data, we evaluated the use of cell-free DNA nucleosome profiles for distinguishing gestational trimesters, fetal sex, and fetal trisomy 21 and highlighted its potential utility for predicting physiological and pathologic fetal conditions by using low-coverage noninvasive prenatal testing data. CONCLUSION: Our analyses profiled nucleosome footprints and regulatory networks during pregnancy and established a noninvasive proof-of-principle methodology for health monitoring during pregnancy.


Assuntos
Expressão Gênica , Teste Pré-Natal não Invasivo , Complicações na Gravidez/sangue , Complicações na Gravidez/genética , Adolescente , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Gravidez , Estudo de Prova de Conceito , Adulto Jovem
3.
Phytochem Anal ; 29(3): 284-289, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29266486

RESUMO

INTRODUCTION: Paclitaxel (Tax) is a diterpene alkaloid isolated from Taxus species and has proved clinically effective in treating a number of malignancies. Current quantitative analytical methods for Tax such as high-performance liquid chromatography (HPLC) often involve complicated sample preparation procedures with low recovery rates. OBJECTIVE: To establish a rapid and sensitive time-resolved fluoroimmunoassay (TRFIA) for measuring Tax in Taxus materials with convenient sample preparation and a high recovery rate. METHODS: Rabbit anti-mouse IgG was coated onto a 96-well microplate, which was then incubated with standard solutions of Tax and anti-Tax monoclonal antibody 3A3. A Eu3+ -labelled conjugate of Tax and human serum albumin was used as the tracer. The luminescent system was enhanced with a solution containing 2-naphthoyltrifluoroacetone. RESULTS: The established TRFIA showed a linear response within the Tax concentration range of 3.2 to 80 ng/mL, with a limit of detection of 1.4 ng/mL. The intra- and inter-assay coefficient of variation of the assay was 9.6% and 9.7%, respectively, with an average recovery rate from spiked samples of 108.5%. Tax contents in Taxus samples were determined using both the established TRFIA system and a previously established enzyme-linked immunosorbent (ELISA), and the results of two assays were well correlated. CONCLUSION: This TRFIA system shows a high sensitivity, precision and accuracy for detection of Tax. This assay, which is convenient and less time-consuming, allows rapid analysis of Tax and provides another option for Tax measurement for quality control of Taxus materials and products. Copyright © 2017 John Wiley & Sons, Ltd.


Assuntos
Antineoplásicos Fitogênicos/análise , Imunofluorescência/métodos , Paclitaxel/análise , Animais , Anticorpos Monoclonais/imunologia , Antineoplásicos Fitogênicos/imunologia , Calibragem , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G/imunologia , Limite de Detecção , Paclitaxel/imunologia , Coelhos , Reprodutibilidade dos Testes , Taxus/química , Estudos de Tempo e Movimento
4.
J Fluoresc ; 27(1): 309-316, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27878521

RESUMO

In this paper, a novel time-resolved fluorescence immunoassay (TRFIA) is described that allows the simultaneous quantitative detection of hepatitis B virus surface antigen (HBsAg) and hepatitis B e antigen (HBeAg) in human serum to aid the diagnosis and monitoring of hepatitis B virus infection. The proposed method was developed based on a two-step sandwich immunoassay protocol in which monoclonal antibodies against HBsAg and HBeAg were co-coated in 96 microtitration wells, then tracer polyclonal antibodies against HBsAg labeled with samarium and tracer monoclonal antibodies against HBeAg labeled with europium chelates were used for detection. The detection range was 0.1-150 IU/mL for HBsAg and 0.5-160 PEIU/mL for HBeAg, and the detection limits were 0.03 IU/L and 0.09 PEIU/ml, respectively. The intra- and inter-assay coefficients of variation were below 8 % for both virus antigens. The dilution linearity and accuracy of the assay were satisfactory. No statistically significant differences were observed in sensitivity or specificity for the serum samples between the dual-label TRFIA and a commercial single-label TRFIA. These results demonstrate that an effective, reliable and convenient HBsAg/HBeAg dual-label TRFIA was successfully developed that may be clinically applicable for blood screening to monitor the course of hepatitis B virus infection and predict treatment responses.


Assuntos
Fluorimunoensaio/métodos , Antígenos de Superfície da Hepatite B/sangue , Vírus da Hepatite B/isolamento & purificação , Hepatite B/diagnóstico , China/epidemiologia , Hepatite B/epidemiologia , Hepatite B/virologia , Humanos , Indicadores e Reagentes
5.
Med Sci Monit ; 23: 5550-5557, 2017 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-29162795

RESUMO

BACKGROUND Array CGH is the criterion standard for identifying copy number variations (CNV), but the restrictive requirement of DNA quality and relatively high cost prevent the use of this method as a general assay in hospitals in developing countries. Our principal objective was to determine whether the semiconductor sequencing platform (SSP) could be an alternative method in CNV detection for spontaneous miscarriage. MATERIAL AND METHODS A total of 443 spontaneous miscarriage samples were collected and subjected to low-coverage (0.1X) whole-genome analysis by SSP. These samples were verified by array CGH and 8 low-quality DNA samples were analyzed by SSP and validated by MLPA. RESULTS SSP detected 195 chromosomal numerical abnormalities, 74 CNVs, and 9 mosaicisms among the 435 samples. Among 74 CNV abnormalities, SSP detected an equal number (56) of CNVs 56 >1 Mb with array CGH. However, SSP missed more 6 cases CNVs <1 Mb than array CGH (12 vs. 18). SSP detected more mosaicisms than array CGH (9 vs. 7, p=0.5). Interestingly, SSP detected the mosaicism which had only 8% X monosomy, which was much lower than the minimal percentage of monosomy that was detected by array CGH. CONCLUSIONS SSP is of equivalent efficacy as array CGH in detecting CNVs >1 Mb, and performs better in identifying mosaicism. With the merits of low cost and less demand of input DNA, SSP is a good alternative for use in genetic diagnosis.


Assuntos
Aborto Espontâneo/genética , Hibridização Genômica Comparativa/métodos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Aberrações Cromossômicas/embriologia , Cromossomos/genética , DNA/genética , Variações do Número de Cópias de DNA/genética , Feminino , Humanos , Análise de Sequência com Séries de Oligonucleotídeos , Polimorfismo de Nucleotídeo Único , Gravidez , Sequenciamento Completo do Genoma/métodos
6.
Biotechnol Lett ; 39(10): 1529-1535, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28600648

RESUMO

OBJECTIVE: To produce a recombinant spermatozoa antigen peptide using the E. coli: PhoA system on a protein chip for screening anti-sperm antibodies (ASA). RESULTS: The purity of the recombinant spermatozoa antigen exceeded 95% after two-step purification, as assessed using SDS-PAGE and HPLC. The diagnostic performance of a protein chip coated with the recombinant antigen peptide was evaluated by examining ASA in 51 infertile patients in comparison with a commercial ELISA kit. The area under the receiver operating characteristic curve (AUC) was 0.944, which indicated that the protein chip coated with recombinant spermatozoa antigen peptide was consistent with ELISA for ASA detection. CONCLUSION: A recombinant spermatozoa antigen was expressed in the E. coli PhoA secretory expression system and its potential application for clinical ASA detection was validated.


Assuntos
Escherichia coli/metabolismo , Infertilidade Masculina/imunologia , Proteínas Recombinantes/metabolismo , Espermatozoides/imunologia , Fosfatase Alcalina/genética , Fosfatase Alcalina/metabolismo , Antígenos/genética , Antígenos/metabolismo , Área Sob a Curva , Autoanticorpos/análise , Ensaio de Imunoadsorção Enzimática , Escherichia coli/genética , Proteínas de Escherichia coli/genética , Proteínas de Escherichia coli/metabolismo , Humanos , Masculino , Análise Serial de Proteínas , Proteínas Recombinantes/genética
7.
J Fluoresc ; 26(3): 987-96, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27034063

RESUMO

The isoenzyme creatine kinase MB is very important for diagnosis of acute myocardial infarction (AMI). Some CK-MB immunoassays are sensitive, accurate and available for clinical application, but they are expensive and time-consuming procedures. Furthermore, conventional fluorescence immunochromatographic assays (FL-ICAs) have suffered from background fluorescence interference and low analytical sensitivity. A rapid and simple FL-ICA with Eu (III) chelate polystyrene microparticles was developed to determine CK-MB in 50uL serum samples using a portable test strip reader by measuring the fluorescence peak heights of the test line (HT) and the control line (HC) in 12 min. The assay was reliable with a good correlation coefficient between HT/HC ratio and CK-MB concentration in samples. A linear range was 0.85-100.29 ng/mL for CK-MB, and the LOD was 0.029 ng/mL. The intra- and inter-assay coefficients of variation (CV) were both <10 % and the average recoveries were from 90.17 % -112.63 % for CK-MB. The system performed well in interference experiments. Furthermore, a highly significant correlation (r = 0.9794, P < 0.001) between this method and the commercially available bioMérieux mini VIDAS system were attained for measuring 120 CK-MB samples. These results indicated that the Eu (III) chelate microparticles-based FL-ICA is simple, fast, highly sensitive, reliable, and reproducible for point-of-care testing of CK-MB concentrations in serum. Graphical Abstract ᅟ.


Assuntos
Quelantes/química , Cromatografia de Afinidade/métodos , Creatina Quinase Forma MB/metabolismo , Európio/química , Microesferas , Cromatografia de Afinidade/instrumentação , Poliestirenos/química , Fitas Reagentes/química , Valores de Referência , Espectrometria de Fluorescência , Fatores de Tempo
8.
J Fluoresc ; 26(1): 317-22, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26563227

RESUMO

The unique photoproperties of quantum dots are promising for potential application in bioassays. In the present study, quantum dots were applied to a luminescent oxygen channeling assay. The reaction system developed in this study was based on interaction of biotin with streptavidin. Carboxyl-modified polystyrene microspheres doped with quantum dots were biotinylated and used as acceptors. Photosensitizer-doped carboxyl-modified polystyrene microspheres were conjugated with streptavidin and used as donors. The results indicated that the singlet oxygen that was released from the donor beads diffused into the acceptor beads. The acceptor beads were then exited via thioxene, and were subsequently fluoresced. To avoid generating false positives, a high concentration (0.01 mg/mL) of quantum dots is required for application in homogeneous immunoassays. Compared to a conventional luminescent oxygen channeling assay, this quantum dots-based technique requires less time, and would be easier to automate and miniaturize because it requires no washing to remove excess labels.


Assuntos
Fluorescência , Corantes Fluorescentes/química , Imunoensaio , Medições Luminescentes , Oxigênio/química , Pontos Quânticos , Corantes Fluorescentes/síntese química , Estrutura Molecular
9.
J Hepatol ; 63(3): 622-33, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25931416

RESUMO

BACKGROUND & AIMS: Liver injury is a common complication of heat stroke (HS), and often constitutes a direct cause for patient death. The cellular and molecular mechanism underlying HS-induced liver injury remains unclear. Recent evidence indicates that inflammasome plays an important role in mediating sterile inflammation triggered by tissue damage. Using a rat HS model, we identified a novel mechanism by which inflammasome-dependent interleukin-1ß (IL-1ß) activation and hepatocyte pyroptosis mediate HS-induced liver injury. METHODS: To induce HS, rats were subjected to heat exposure. Inhibition of inflammasomes was achieved by RNA silencing and pharmacologic inhibitor prior to heat exposure. Inflammasome assembly, caspase-1 activation, histological changes, as well as serum levels of liver enzymes were measured. RESULTS: We demonstrated that the onset of HS activated inflammasome in the liver as evidenced by increased capase-1 activity and the association of inflammasome components NOD-like receptor family pyrin domain containing 3 (Nlrp3) and apoptosis speck-like protein containing a caspase-recruitment domain (ASC); and the activated inflammasome, in turn, induced IL-1ß activation and hepatocyte pyroptosis, and subsequent augmented liver injury. HS-induced hepatocyte inflammasome activation seems to be high-mobility group box 1 (HMGB1) dependent. Inhibition of Nlrp3, caspase-1, or HMGB1 prevented HS-induced liver inflammation and ameliorated liver injury. CONCLUSIONS: These findings demonstrate an important role of HMGB1 in mediating inflammasome activation in the development of liver injury following HS, and suggest that targeting inflammasome may represent a novel therapeutic strategy to limit cell death and prevent liver failure after HS.


Assuntos
Proteína HMGB1/fisiologia , Golpe de Calor/complicações , Interleucina-1beta/fisiologia , Hepatopatias/etiologia , Piroptose , Animais , Proteínas de Transporte/fisiologia , Caspase 1/metabolismo , Hepatócitos/patologia , Masculino , Proteína 3 que Contém Domínio de Pirina da Família NLR , Ratos , Ratos Sprague-Dawley , Sístole
10.
J Med Virol ; 87(11): 1940-5, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26129643

RESUMO

Enzyme-linked immunosorbent assay (ELISAs) specific for Epstein-Barr virus nuclear antigen 1 (EBNA1)-immunoglobulin A (IgA) are most commonly used in the clinical diagnosis of EBV infection. But they have a low sensitivity and the enzyme-labeled antibodies are unstable. In this study, a novel immunoassay based on an indirect time-resolved fluoroimmunoassay (TRFIA) was developed. Microtiter plates were coated with recombinant EBNA1. We used Eu(3) (+)-labeled anti-human IgA as probe. The precision, sensitivity, specificity, and stability were evaluated, and comparison with traditional and commercially available ELISAs was also made. The cut-off value for our TRFIA was 2.7. Intra- and inter-assay coefficients of variation for the TRFIA were 1.56-4.99% and 3.92-6.95%, respectively; whereas those for the ELISA were 4.54-8.16% and 7.07-10.52%, respectively. Sensitivity was obviously better than traditional ELISA when diluted positive samples serially. Additionally, stability, specificity test and comparison of sensitivity and specificity between the TRFIA and commercial ELISAs all proved satisfactory. In conclusion, the results demonstrated that EBNA1 IgA TRFIA was a sensitive immunoassay and had potential value in large-scale screening of human serum samples in developing countries.


Assuntos
Anticorpos Antivirais/sangue , Infecções por Vírus Epstein-Barr/diagnóstico , Antígenos Nucleares do Vírus Epstein-Barr/imunologia , Imunofluorescência/métodos , Herpesvirus Humano 4/imunologia , Imunoglobulina A/sangue , Infecções por Vírus Epstein-Barr/imunologia , Humanos , Sensibilidade e Especificidade , Soro/química
11.
Luminescence ; 30(5): 649-54, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25377426

RESUMO

Enzyme-linked immunosorbent assays (ELISA) specific for anti-HSV glycoprotein G (gG) are most commonly used in the clinical diagnosis of HSV infection. But most of them are qualitative and with narrow detection ranges. A novel time-resolved fluoroimmunoassay (TRFIA) methodology was developed for the quantitative determination of HSV IgG in human serum. The assay was based on an indirect immunoassay format, and performed in 96-well microtiter plates. HSV-1 and HSV-2 were used as the coating antigens. Eu(3+)-labeled goat anti-(human IgG) polyclonal antibodies were used as tracers. The fluorescence intensity of each well was measured and serum HSV IgG levels quantified against a calibration curve. The detection range of the novel TRFIA was between 5 and 500 AU/mL. Assay sensitivity was 0.568 AU/mL. The intra- and inter-assay coefficients of variation were 0.59-3.63% and 3.65-6.81%, respectively. Analytical recovery, dilution tests and serum panel tests were performed using TRFIA and the results proved satisfactory. There were no statistically significant differences in sensitivity and specificity between the TRFIA and commercial ELISAs. An effective, sensitive and accurate quantitative HSV type 1 and type 2 IgG TRFIA was successfully developed and provided diagnostic value in clinical use.


Assuntos
Anticorpos Antivirais/sangue , Fluorimunoensaio/métodos , Herpesvirus Humano 1/imunologia , Herpesvirus Humano 2/imunologia , Ensaio de Imunoadsorção Enzimática , Herpes Simples/sangue , Herpes Simples/virologia , Humanos , Imunoglobulina G , Sensibilidade e Especificidade
12.
Luminescence ; 29(6): 591-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24136927

RESUMO

Current clinically assays, such as enzyme-linked immunosorbent assay and chemiluminescence immunoassay, for hepatitis B surface antigen (HBsAg) are inferior in terms of either sensitivity and accuracy or rapid and high-throughput analysis. A novel assay based on magnetic beads and time-resolved fluoroimmunoassay was developed for the quantitative determination of HBsAg in human serum. HBsAg was captured using two types of anti-HBsAg monoclonal antibodies (B028, S015) immobilized on to magnetic beads and detected using europium-labeled anti-HBsAg polyclonal detection antibody. Finally, the assay yielded a high sensitivity (0.02 IU/mL) and a wide dynamic range (0.02-700 IU/mL) for HBsAg when performed under optimal conditions. Satisfactory accuracy, recovery and specificity were also demonstrated. The intra- and interassay coefficients of variation were 4.7-8.7% and 3.8-7.5%, respectively. The performance of this assay was further assessed against a well-established commercial chemiluminescence immunoassay kit with 399 clinical serum samples. It was revealed that the test results for the two methods were in good correlation (Y = 1.182X - 0.017, R = 0.989). In the current study, we demonstrated that this novel time-resolved fluoroimmunoassay could be used: as a highly sensitive, automated and high-throughput immunoassay for the diagnosis of acute or chronic hepatitis B virus infection; for the screening of blood or organ donors; and for the surveillance of persons at risk of acquiring or transmitting hepatitis B virus.


Assuntos
Antígenos de Superfície da Hepatite B/sangue , Imunoensaio , Fenômenos Magnéticos , Humanos , Luminescência , Fatores de Tempo
13.
Analyst ; 138(13): 3697-704, 2013 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-23671904

RESUMO

In this paper, a novel time-resolved fluoroimmunoassay (TRFIA) protocol using magnetic particles for the simultaneous determination of α-fetoprotein (AFP) and the free ß-subunit of human chorionic gonadotropin (free ß-hCG) in human serum is described. The new approach uses magnetic particles as an immobilization matrix and means of separation, while the luminescent europium and samarium chelates are used as probes. The proposed method was evaluated via a single-step, sandwich-type TRFIA immunoassay of AFP and free ß-hCG as model analytes in serum. With the advantages of magnetic particles, the TRFIA immunoassay exhibited a wide dynamic range for AFP of 0.1-750 ng mL(-1), with a lower detection limit of 0.05 ng mL(-1). The dynamic range for free ß-hCG was 0.16-450 ng mL(-1), with a lower detection limit of 0.08 ng mL(-1). Satisfactory specificity, reproducibility, and recovery of the immunoassay were demonstrated. Good correlations were obtained in the analysis of 446 human serum samples between the proposed method and a commercial TRFIA kit. These results demonstrate the feasibility and potential of the new method as a rapid and highly sensitive immunoassay that could be developed into a platform for multi-analyte determinations in clinical practice.


Assuntos
Gonadotropina Coriônica Humana Subunidade beta/análise , Fluorimunoensaio/métodos , Imãs , alfa-Fetoproteínas/análise , Biomarcadores/sangue , Gonadotropina Coriônica Humana Subunidade beta/sangue , Feminino , Humanos , Gravidez , Reprodutibilidade dos Testes , Fatores de Tempo
14.
J Fluoresc ; 23(4): 649-57, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23471623

RESUMO

Quantum dots are not widely used in clinical diagnosis. However, the homogeneous time-resolved fluorescence assay possesses many advantages over current methods for the detection of carcinoembryonic antigen (CEA), a primary marker for many cancers and diseases. Therefore, a novel luminescent terbium chelates- (LTCs) and quantum dots-based homogeneous time-resolved fluorescence assay was developed to detect CEA. Glutathione-capped quantum dots (QDs) were prepared from oil-soluble QDs with a 565 nm emission peak. Conjugates (QDs-6 F11) were prepared with QDs and anti-CEA monoclonal antibody. LTCs were prepared and conjugates (LTCs-S001) were prepared with another anti-CEA monoclonal antibody. The fluorescence lifetime of QDs was optimized for sequential analysis. The Förster distance (R0) was calculated as 61.9 Å based on the overlap of the spectra of QDs-6 F11 and LTCs-S001. Using a double-antibody sandwich approach, the above antibody conjugates were used as energy acceptor and donor, respectively. The signals from QDs were collected in time-resolved mode and analyzed for the detection of CEA. The results show that the QDs were suitable for time-resolved fluoroassays. The spatial distance of the donor-acceptor pair was calculated to be 61.9 Å. The signals from QDs were proportional to CEA concentration. The standard curve was LogY = 2.75566 + 0.94457 LogX (R = 0.998) using the fluorescence counts (Y) of QDs and the concentrations of CEA (X). The calculated sensitivity was 0.4 ng/mL. The results indicate that water-soluble QDs are suitable for the homogenous immunoassay. This work has expanded future applications of QDs in homogeneous clinical bioassays. Furthermore, a QDs-based homogeneous multiplex immunoassay will be investigated as a biomarker for infectious diseases in future research.


Assuntos
Antígeno Carcinoembrionário/análise , Fluorimunoensaio/métodos , Pontos Quânticos , Água/química , Animais , Quelantes/química , Transferência Ressonante de Energia de Fluorescência , Corantes Fluorescentes/química , Solubilidade , Térbio/química , Fatores de Tempo
15.
J Clin Lab Anal ; 27(4): 277-83, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23852784

RESUMO

BACKGROUND: Cytokeratin 19 fragment antigen (CYFRA 21-1) is used to diagnose and monitor neoplasms. However, the main disadvantages of the currently available CYFRA 21-1 assays include heterogenous technology, being time-consuming, and having low through-put with low insensitivity. This study investigated the use of amplified luminescent proximity homogeneous immunoassay (AlphaLISA) for the quantization of CYFRA 21-1 in human serum. METHODS: The AlphaLISA kit was developed based on AlphaScreen detection technology with two different anti-CYFRA 21-1 monoclonal antibodies. One was coated on AlphaLISA acceptor beads and the other was biotinylated. Donor beads were coated with streptavidin. The test conditions were optimized and analytical performance was studied. RESULTS: The measurement range of AlphaLISA CYFRA 21-1 kit was 0.08-500 ng/ml. Assay detection limit was 0.08 ng/ml. The intra- and interassay coefficients of variation were 3.00-9.00% and 4.00-10.00%, respectively. There was no cross-reaction to alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), neuron-specific enolase (NSE), cancer antigen 19-9 (CA19-9), cytokeratins 8 (CK8), and cytokeratins 18 (CK18). The correlation coefficient of blood samples involved was 0.974 between CYFRA 21-1-AlphaLISA assay and a commercial electrochemiluminescence immunoassay (ECLIA) CYFRA 21-1 kit (Roche). CONCLUSIONS: The AlphaLISA CYFRA 21-1 kit developed in this study had favorable performance characteristics for clinical application with acceptable analytical sensitivity, specificity, and accuracy.


Assuntos
Antígenos de Neoplasias/sangue , Imunoensaio/métodos , Queratina-19/sangue , Medições Luminescentes/métodos , Biomarcadores Tumorais/sangue , Humanos , Neoplasias Pulmonares/diagnóstico , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Luminescence ; 28(3): 401-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22715159

RESUMO

Time-resolved fluorometry of lanthanide chelates is one of the most useful non-isotopic detection techniques and has been used in numerous applications in biomedical science. We developed a time-resolved fluoroimmunoassay (TRFIA) to quantify α-fetoprotein (AFP) and hepatitis B virus surface antigen (HBsAg) in human serum. Based on a two-site sandwich protocol, monoclonal antibodies (McAbs) against AFP and HBsAg were co-coated in 96 microtitration wells and tracer McAbs against HBsAg and AFP were labeled with europium (Eu) and samarium (Sm) chelates, respectively. After application of diluted serum samples, Eu(3+)- and Sm(3+)-McAbs were added and fluorescence signals of Sm(3+) and Eu(3+) tracers were collected. Detection limits of AFP and HBsAg were 0.09 mIU/L and 0.01 µg/L, respectively. Measurement ranges of AFP-TRFIA and HBsAg-TRFIA were 1-1000 mIU/L and 0.2-150 µg/L, respectively. Intra- and inter-assay coefficients of variation of AFP-TRFIA were 3.3-4.1% and 5.7-7.2% and for HBsAg-TRFIA were 2.9-3.9% and 4.9-6.8%, respectively. Linear correlation of TRFIA and chemiluminescence immunoassay measurements resulted in a correlation coefficient of 0.9949 for AFP and 0.9940 for HBsAg. For the endurance test, Eu-labeled McAbs were stable for at least one year at -20°C and the results of the TRFIA with the same reagents were also reproducible after one year. The availability of a highly sensitive, reliable and convenient AFP/HBsAg TRFIA will allow the quantification of both AFP and HBsAg, thereby providing diagnostic value in various clinical conditions and could be applied for clinical use.


Assuntos
Fluorimunoensaio/métodos , Antígenos de Superfície da Hepatite B/sangue , Vírus da Hepatite B/química , alfa-Fetoproteínas/análise , Fluorimunoensaio/instrumentação , Hepatite B/sangue , Hepatite B/virologia , Humanos
17.
Luminescence ; 28(2): 156-61, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22345047

RESUMO

We developed a luminescent terbium sensor (LTS) based on energy resonance transfer for homogeneous bioassays. The effect of temperature on photoluminescence and time-resolved fluorescence of the LTS was investigated. When the temperature was increased from 277 K to 369 K, the photoluminescence quantum yield decreased by up to 25 %, time-resolved fluorescence decreased by up to 54 %, and the lifetime shortened dramatically. Studies showed that both photoluminescence and time-resolved fluorescence quantum yields were largely recovered after samples were heated from 298 to 310, 333 or 369 K and subsequently cooled to 298 K. These results indicate that the homogeneous bioassay with LTS is sensitive to temperature and should be conducted at a constant temperature to ensure the temperature effect does not influence data and to increase the accuracy of the results. The results of this study are important for LTS applications in homogeneous bioassays.


Assuntos
Bioensaio/instrumentação , Técnicas Biossensoriais/instrumentação , Térbio/química , Transferência de Energia , Fluorescência , Temperatura
18.
J Immunoassay Immunochem ; 34(2): 134-48, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23537299

RESUMO

Measurement of the free ß subunit of human chorionic gonadotropin (free ß-hCG) in serum is useful for prenatal screening. Concentrations of free ß-hCG vary in different races. Conventional assays used for such measurements have limitations. We applied the AlphaLISA to measure levels of free ß-hCG in maternal serum during 8-20 weeks of gestation in women from southern China. Two anti-free ß-hCG antibodies were used: one was coated on AlphaLISA acceptor beads and the one was biotinylated. The assay also contained donor beads coated with streptavidin. The AlphaLISA assay detection limit was 0.11 ng/mL, and the analytical range was 0.11-200 ng/mL. The intra- and interassay coefficients of variation were 1.32%-2.50% and 3.44%-5.45%, respectively. The correlation with commercial Eu(3+)-labeled free ß-HCG-TRFIA assay was good (y = 1.045x + 1.580, r(2) = 0.978). Median levels of free ß-hCG in maternal serum at 8-20 weeks gestation were higher in women from southern China compared with those reported in women from other countries. The AlphaLISA for free ß-HCG could become the assay of choice for applications in clinical diagnostics. The established median value of free ß-HCG is helpful in clinical diagnosis specific for southern Chinese women.


Assuntos
Gonadotropina Coriônica Humana Subunidade beta/sangue , Imunoensaio/normas , Primeiro Trimestre da Gravidez/sangue , Primeiro Trimestre da Gravidez/etnologia , Adulto , Povo Asiático , Feminino , Humanos , Limite de Detecção , Gravidez , Diagnóstico Pré-Natal
19.
Mol Biol Rep ; 39(10): 9557-62, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22740136

RESUMO

Recently, a genome-wide association study of gastric cancer (GC) reported the significant association of seven genetic variants (rs4072037 and rs4460629 on 1q22; rs753724, rs11187842, rs3765524, rs2274223, and rs3781264 on 10q23) with GC in a Chinese population. These findings were confirmed in a subsequent independent study. However, it remains unknown whether these loci are associated with an increased risk of colorectal cancer (CRC). This study was to test whether the seven single nucleotide polymorphisms (SNPs) associated with GC were also associated with CRC in a Chinese population. The seven SNPs were genotyped using MassARRAY system. Allelic, genotypic, and haplotypic associations of the SNPs with CRC were investigated using χ(2) tests and logistic regression analysis. The SNPs rs3765524 and rs2274223, located on 10q23, were found to have significant protective effects against CRC, with equal odds ratios per allele. The two SNPs located on 1q22 (rs4072037 and rs4460629) showed a weak association with CRC. No significant association was identified with CRC for the remaining three SNPs located on 10q23 (rs753724, rs11187842, and rs3781264). These results suggest that rs3765524 and rs2274223 on 10q23 are associated with a protective effect against CRC in a Chinese population.


Assuntos
Cromossomos Humanos Par 10/genética , Neoplasias Colorretais/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Estudos de Casos e Controles , Feminino , Frequência do Gene , Estudos de Associação Genética , Genótipo , Haplótipos , Humanos , Desequilíbrio de Ligação , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Análise de Sequência de DNA , Adulto Jovem
20.
Int J Mol Sci ; 13(7): 8364-8378, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22942708

RESUMO

DNA hypomethylation and/or hypermethylation are presumed to be early events in carcinogenesis, and one or more DNA methyltransferases (DNMTs) have been suggested to play roles in carcinogenesis of gastric cancer (GC). However, there have been no systematic studies regarding the association between DNMT gene polymorphisms and GC risk. Here, we examined the associations of 16 single nucleotide polymorphisms (SNPs) from DNMT1 (rs2114724, rs2228611, rs2228612, rs8101866, rs16999593), DNMT2 (rs11695471, rs11254413), DNMT3A (rs1550117, rs11887120, rs13420827, rs13428812, rs6733301), DNMT3B (rs2424908, rs2424913, rs6087990) and DNMT3L (rs113593938) with GC in the Southern Chinese population. We assessed the associations of these 16 SNPs with GC in a case-control study that consisted of 242 GC cases and 294 controls, using the Sequenom MALDI-TOF-MS platform. Association analyses based on the χ(2) test and binary logistic regression were performed to determine the odds ratio (OR) and 95% confidence interval (95%CI) for each SNP. We found that rs16999593 in DNMT1, rs11254413 in DNMT2 and rs13420827 in DNMT3A were significantly associated with GC susceptibility (OR 1.45, 0.15, 0.66, respectively; 95% CI 1.00-2.11, p = 0.047; 0.08-0.27, p < 0.01; 0.45-0.97, p = 0.034, respectively, overdominant model). These results suggested that DNMT1, DNMT2 and DNMT3A may play important roles in GC carcinogenesis. However, further studies are required to elucidate the mechanism.


Assuntos
DNA (Citosina-5-)-Metiltransferases/genética , Polimorfismo de Nucleotídeo Único , Neoplasias Gástricas/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , China , DNA (Citosina-5-)-Metiltransferase 1 , DNA Metiltransferase 3A , Feminino , Estudos de Associação Genética , Predisposição Genética para Doença , Haplótipos , Humanos , Desequilíbrio de Ligação , Masculino , Pessoa de Meia-Idade , Risco , Neoplasias Gástricas/enzimologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA