Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Mikrochim Acta ; 191(5): 280, 2024 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649540

RESUMO

An interfacial galvanic replacement strategy to controllable synthesize palladium nanoparticles (Pd NPs)-modified NiFe MOF nanocomposite on nickel foam, which served as an efficient sensing platform for quantitative determination of dopamine (DA). Pd NPs grown in situ on the nanosheets of NiFe MOF via self-driven galvanic replacement reaction (GRR) and well uniform distribution was achieved. This method effectively reduced the aggregation of metallic nanoparticles and significantly promoted the electron transfer rate during the electrochemical process, leading to improved electrocatalytic activity for DA oxidation. Remarkably, the precisely constructed biosensor achieved a low detection limit (LOD) of 0.068 µM and recovery of 94.1% (RSD 6.7%, N = 3) for simulated real sample detection and also exhibited superior selectivity and stability. The results confirmed that the as-fabricated Pd-NiFe/NF composite electrode could realize the quantitative determination of DA and showed promising prospects in real sample biosensing.


Assuntos
Técnicas Biossensoriais , Dopamina , Estruturas Metalorgânicas , Nanoestruturas , Dopamina/análise , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/normas , Níquel/química , Eletrodos/normas , Paládio/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Microscopia Eletrônica de Varredura , Estruturas Metalorgânicas/síntese química , Estruturas Metalorgânicas/ultraestrutura , Sensibilidade e Especificidade , Condutividade Elétrica , Microscopia Eletrônica de Transmissão , Ferro/química , Reprodutibilidade dos Testes
2.
Caries Res ; 53(2): 176-193, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30107375

RESUMO

Streptococcus mutans, the primary cause of dental caries, takes up carbohydrates through the phosphoenolpyruvate sugar phosphotransferase system (PTS). This study aimed to identify a novel membrane-targeted antimicrobial peptide (AMP) that could also target the L-ascorbate-specific PtxA component of the S. mutans PTS system. C10-KKWW was identified and selected using virtual screening of a lipopeptide library, a minimum inhibiting concentration (MIC) assay, cytotoxicity assays and a hemolysis assay. Surface plasmon resonance confirmed that C10-KKWW had a high binding affinity for PtxA. Combining with scanning electron microscopy and cell permeability assay, it was shown that the effects of C10-KKWW could be attributed to both membrane and PtxA. Wild type (WT) S. mutans, a ptxA deletion mutant (ΔptxA), and a mutant-complemented strain (CptxA), were cultured consistently in brain heart infusion (BHI) medium, tryptone-vitamin medium supplemented with 15 mM L-ascorbate (TVL), or for 5 h in BHI supplemented with 7.4 mM sodium L-ascorbate. Compared to ∆ptxA, in WT S. mutans and CptxA, C10-KKWW had a stronger MIC (3.9 µg/mL), and distinctively decreased biofilm viability. The extracellular concentrations of L-ascorbate/sodium L-ascorbate were not changed before and after WT treated with C10-KKWW. L-ascorbate-induced operon genes, or other PTS genes, were significantly suppressed by C10-KKWW. In conclusion, C10-KKWW has been developed; it acts through interaction with the bacterial membrane and interferes with L-ascorbate translocation to inhibit S. mutans growth and eradicate its biofilm. C10-KKWW may be especially effective at optimal oral ascorbate levels. A combination of C10-KKWW with sodium L-ascorbate might also be a novel strategy for dental caries treatment.


Assuntos
Biofilmes , Cárie Dentária , Sistema Fosfotransferase de Açúcar do Fosfoenolpiruvato , Streptococcus mutans , Cárie Dentária/microbiologia , Cárie Dentária/prevenção & controle , Humanos , Peptídeos , Fosfotransferases , Streptococcus mutans/enzimologia
3.
Bioelectrochemistry ; 158: 108680, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38493575

RESUMO

Electrochemical immunosensors have gained considerable attention in detecting human disease markers due to their excellent specificity, high sensitivity, and facile operation. Herein, a rational-designed sandwich-type electrochemical immunosensor is constructed for the sensitive detection of cardiac troponin I (cTnI) using nitrogen-doped carbon nanotubes loaded with gold nanoparticles (Au NPs/N-CNTs) as substrate and highly active mesoporous palladium-nitrogen nanocubes (meso-PdN NCs) as secondary antibody markers. Benefitting from its large specific surface area (638.04 m2 g-1) and high nitrogen content, novel polydopamine (PDA)/ halloysite nanotubes (HNTs) hybrid derived one-dimensional (1D) N-CNTs can provide more binding sites for the in-situ growth of Au NPs to connect Ab1. Furthermore, as an ideal substrate material, Au NPs/N-CNTs exhibit finely tuned mesoporous structures and outstanding conductivity, which facilitate the mass and electron transfer during the electrocatalysis process. Besides, highly concave surfaces and crystalline mesopores of meso-PdN NCs expose more surfaces and crevices, providing abundant reactive sites for H2O2 reduction. Remarkably, the as-obtained immunosensor presented a wide linear range (from 10 fg mL-1 to 100 ng mL-1) and an excellent low detection limit (9.85 fg mL-1). This study may offer new insights into the precise fabrication of efficient electrochemical immunosensors for various clinical diagnosis applications.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Ouro , Limite de Detecção , Nanopartículas Metálicas , Nanotubos de Carbono , Paládio , Troponina I , Ouro/química , Troponina I/análise , Troponina I/sangue , Nanopartículas Metálicas/química , Humanos , Nanotubos de Carbono/química , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Técnicas Biossensoriais/métodos , Paládio/química , Nitrogênio/química , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia
4.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 41(4): 471-477, 2023 Aug 01.
Artigo em Inglês, Zh | MEDLINE | ID: mdl-37474480

RESUMO

When the use of root canal retreatment and apical surgery experiences difficulty in treating endodontic diseases, intentional replantation is an optional clinical technique used to retain the tooth. A 28-year-old female complained of chewing discomfort at the mandibular second molar after undergoing root canal treatment 3 month ago. History record and radiographic examination revealed that a C-shaped root canal system was filled with gutta-percha in the mandibular second molar. A radiolucency area existed at the root furcal area with a thin canal wall in the distal and mesial roots. Intentional replantation was used to treat this tooth. The clinical and radiographic results showed that intentional replantation and nano-biomaterial application facilitated infection control, tooth retention, and periodontal tissue regeneration.


Assuntos
Tratamento do Canal Radicular , Reimplante Dentário , Feminino , Humanos , Adulto , Cavidade Pulpar , Guta-Percha/uso terapêutico , Raiz Dentária , Dente Molar/cirurgia , Retratamento
5.
J Appl Oral Sci ; 29: e20200266, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33825761

RESUMO

OBJECTIVES: We analyzed the effects of the Er:YAG laser used with different parameters on dentinal tubule (DT) occlusion, intrapulpal temperature and pulp tissue morphology in order to determine the optimal parameters for treating dentin hypersensitivity. METHODOLOGY: Dentin specimens prepared from 36 extracted human third molars were randomized into six groups according to the treatment method (n=6 each): control (A); Gluma desensitizer (B); and Er:YAG laser treatment at 0.5 W , 167 J/cm2 (50 mJ, 10 Hz) (C), 1 W , 334 J/cm2 (50 mJ, 20 Hz) (D), 2 W , 668 J/cm2 (100 mJ, 20 Hz) (E), and 4 W and 1336 J/cm2 (200 mJ, 20 Hz) (F). Treatment-induced morphological changes of the dentin surfaces were assessed using scanning electron microscopy (SEM) to find parameters showing optimal dentin tubule occluding efficacy. To further verify the safety of these parameters (0.5 W, 167 J/cm2), intrapulpal temperature changes were recorded during laser irradiation, and morphological alterations of the dental pulp tissue were observed with an upright microscope. RESULTS: Er:YAG laser irradiation at 0.5 W (167 J/cm2) were found to be superior in DT occlusion, with an exposure rate significantly lower than those in the other groups (P<0.05). Intrapulpal temperature changes induced by Er:YAG laser irradiation at 0.5 W (167 J/cm2) with (G) and without (H) water and air cooling were demonstrated to be below the threshold. Also, no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. CONCLUSION: Therefore, 0.5 W (167 J/cm2) is a suitable parameter for Er:YAG laser to occlude DTs, and it is safe to the pulp tissue.


Assuntos
Lasers de Estado Sólido , Oclusão Dentária , Dentina , Humanos , Lasers de Estado Sólido/uso terapêutico , Microscopia Eletrônica de Varredura
6.
J. appl. oral sci ; 29: e20200266, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1180799

RESUMO

Abstract Objectives We analyzed the effects of the Er:YAG laser used with different parameters on dentinal tubule (DT) occlusion, intrapulpal temperature and pulp tissue morphology in order to determine the optimal parameters for treating dentin hypersensitivity. Methodology Dentin specimens prepared from 36 extracted human third molars were randomized into six groups according to the treatment method (n=6 each): control (A); Gluma desensitizer (B); and Er:YAG laser treatment at 0.5 W , 167 J/cm2 (50 mJ, 10 Hz) (C), 1 W , 334 J/cm2 (50 mJ, 20 Hz) (D), 2 W , 668 J/cm2 (100 mJ, 20 Hz) (E), and 4 W and 1336 J/cm2 (200 mJ, 20 Hz) (F). Treatment-induced morphological changes of the dentin surfaces were assessed using scanning electron microscopy (SEM) to find parameters showing optimal dentin tubule occluding efficacy. To further verify the safety of these parameters (0.5 W, 167 J/cm2), intrapulpal temperature changes were recorded during laser irradiation, and morphological alterations of the dental pulp tissue were observed with an upright microscope. Results Er:YAG laser irradiation at 0.5 W (167 J/cm2) were found to be superior in DT occlusion, with an exposure rate significantly lower than those in the other groups (P<0.05). Intrapulpal temperature changes induced by Er:YAG laser irradiation at 0.5 W (167 J/cm2) with (G) and without (H) water and air cooling were demonstrated to be below the threshold. Also, no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Conclusion Therefore, 0.5 W (167 J/cm2) is a suitable parameter for Er:YAG laser to occlude DTs, and it is safe to the pulp tissue.


Assuntos
Humanos , Lasers de Estado Sólido/uso terapêutico , Microscopia Eletrônica de Varredura , Oclusão Dentária , Dentina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA