Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Phys Rev Lett ; 132(23): 235101, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38905665

RESUMO

In this study, we discovered a turbulence transition in a large helical device. The turbulence level and turbulence-driven energy transport decrease to a specific transition density and increase above it. The ruling turbulences below and above the transition density were ion-temperature gradient (ITG) and resistive-interchange (RI) turbulences, consistent with the predictions of gyrokinetic theory and two-fluid MHD model, respectively. Isotope experiments on hydrogen (H) and deuterium (D) clarified the role of transitions. In the ITG regime, turbulence levels and energy transport were comparable in the H and D plasmas. In contrast, in the RI regime, they were clearly suppressed in the D plasma. The results provide crucial knowledge for understanding isotope effects and future optimization of stellarator and heliotron devices.

2.
Phys Rev Lett ; 129(25): 255001, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36608252

RESUMO

The ablation and assimilation of cryogenic pure H_{2} and mixed H_{2}+Ne pellets, which are foreseen to be used by the ITER tokamak for mitigating thermal and electromagnetic loads of major disruptions, are observed by spatially and temporally resolved measurements. It is experimentally demonstrated that a small fraction (here ≈5%) of neon added to hydrogenic pellets enhances the core density assimilation with reduced outward transport for the low magnetic-field side injection. This is consistent with theoretical expectations that line radiation increased by doped neon in dense plasmoids suppresses the plasmoid pressure and reduces the E[over →]×B[over →] transport of the ablated material.

3.
Opt Express ; 29(20): 31706-31713, 2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34615258

RESUMO

We report on an electro-optically Q-switched Tb:LiYF4 green laser pumped by a frequency-doubled optically pumped semiconductor blue laser. The electro-optically Q-switched characteristics were studied under a wide range of repetition rates from 200 Hz to 50 kHz using a KD2PO4 Q-switch. Up to 198 µJ of pulse energy was obtained with a pulse width of 248 ns at a repetition rate of 200 Hz, corresponding to a peak power of 797 W at 544 nm.

4.
Phys Rev Lett ; 127(22): 225001, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34889640

RESUMO

We assess the magnetic field configuration in modern fusion devices by comparing experiments with the same heating power, between a stellarator and a heliotron. The key role of turbulence is evident in the optimized stellarator, while neoclassical processes largely determine the transport in the heliotron device. Gyrokinetic simulations elucidate the underlying mechanisms promoting stronger ion scale turbulence in the stellarator. Similar plasma performances in these experiments suggests that neoclassical and turbulent transport should both be optimized in next step reactor designs.

5.
Opt Express ; 28(8): 10951-10959, 2020 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-32403616

RESUMO

We report laser operation of two Tb3+-activated gain media, Tb:LiYF4 and LiTbF4, in yellow or/and green spectral region. A record-high slope efficiency of 63% among Tb3+-lasers and maximum output power of 1.17 W (incident power of 2.79 W) at around 544 nm were obtained with a c-cut 15%Tb:LiYF4 crystal. The yellow laser characteristics in σ-polarization were studied. A slope efficiency of 21% at 582 nm was achieved. More importantly, we succeeded in laser operation of LiTbF4 for the first time to the best of our knowledge. Laser oscillation at around 544 nm yielded a maximum slope efficiency of 45%. This points toward the possibility of producing high-energy pulsed lasers using LiTbF4, which features a high active-ion concentration as well as relatively long lifetime.

6.
Opt Lett ; 45(16): 4615-4617, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32797023

RESUMO

Optical grade Dy2O3 ceramics was successfully produced by adding a small amount of ZrO2 as a sintering aid and hot isostatic pressing treatment at 1500∘C after pre-sintering at 1550∘C. No residual pores, grain boundary phases, or second phases were detected inside the transparent ceramics. Since birefringence was not observed under the polarizer, the produced Dy2O3 ceramics is an optically isotropic body. There was almost no beam distortion during the laser irradiation test, and the optical loss was extremely small (<0.1%/cm). The Verdet constant was 422radT-1m-1 at a wavelength of 633 nm, and the extinction ratio was 34 dB.

7.
Opt Lett ; 45(9): 2596-2599, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32356825

RESUMO

We report the Q-switched operation of a Tb3+-laser for the first time, to the best of our knowledge. The passiveQ-switching was realized by a 15% Tb:LiYF4 gain medium and a single-layer graphene saturable absorber. An average output power of 744 mW at 544 nm was achieved with slope efficiency of 41%, pulse width of 2.9 µs, and repetition rate of 38.7 kHz. The corresponding pulse energy and peak power were calculated to be 19.2 µJ and 6.6 W, respectively.

8.
Opt Lett ; 44(13): 3378-3381, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31259965

RESUMO

Nd,Y:CaF2 and Nd,La:CaF2 ceramics featuring good optical quality have been fabricated by reactive sintering and a hot isostatic pressing method. The transmission spectra, emission spectra, and fluorescence decay curves were measured. Lasing at 1064 and 1065 nm was observed in Nd,Y:CaF2 and Nd,La:CaF2, respectively, upon quasi-continuous-wave pumping by a diode laser emitting at 791 nm. To the best of our knowledge, this is the first demonstration of Nd3+-activated CaF2 ceramic laser.

9.
Opt Express ; 22(4): 4144-51, 2014 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-24663738

RESUMO

A Faraday isolator with compensation of thermally induced depolarization outside magnetic field was implemented for the first time on TGG ceramics. Stable isolation ratio of 38 dB in steady-state regime at a laser power of 300 W was demonstrated in experiment. Theoretical estimates show a feasibility of a device that would provide an isolation ratio higher than 30 dB up to laser power of 2kW.

10.
Exp Cell Res ; 319(8): 1220-8, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23500413

RESUMO

Cancer stem cells (CSCs) are among the target cells of cancer therapy because they are uniquely involved in both cancer progression and sensitivity to chemotherapeutic agents. We identified side population (SP) cells, which are known to be an enriched population of CSC, in five oral squamous cell carcinoma (OSCC) cells (SCC9, SCC25, TOSCC7, TOSCC17, and TOSCC23). The percentages of SP cells ranged from 0% to 3.3%, with TOSCC23 cells showing the highest percentages of SP cells (3.3% of the total cell population). The SP cells isolated from TOSCC23 cells also showed greater cell proliferation and invasion compared to non-SP (MP) cells. Therefore, our initial findings suggested that SP cells were enriched for CSC-like cells. Furthermore, DNA microarray analysis revealed that the expression of cell proliferation-related and anti-apoptotic genes was greater in SP cells compared to MP cells. We focused on Lin28a, which showed the highest expression (approximately 22-fold) among the upregulated genes. The overexpression of Lin28a in TOSCC23 cells increased their proliferation, colony formation, and invasion. These findings suggest that Lin28a is an appropriate CSC target molecule for OSCC treatment.


Assuntos
Carcinoma de Células Escamosas/genética , Carcinoma de Células Escamosas/patologia , Proteínas de Ligação a DNA/fisiologia , Neoplasias Bucais/genética , Neoplasias Bucais/patologia , Células-Tronco Neoplásicas/patologia , Linhagem Celular Tumoral , Proliferação de Células , Proteínas de Ligação a DNA/genética , Perfilação da Expressão Gênica , Regulação Neoplásica da Expressão Gênica , Humanos , Análise em Microsséries , Invasividade Neoplásica , Células-Tronco Neoplásicas/metabolismo , Células-Tronco Neoplásicas/fisiologia , Proteínas de Ligação a RNA , Nicho de Células-Tronco/genética , Transfecção , Microambiente Tumoral/genética
11.
Sci Rep ; 12(1): 15112, 2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36068266

RESUMO

Thomson scattering measurements with a high-repetition-rate laser have commenced in the Large Helical Device. As an example of the fast phenomena captured by this diagnostic system, measurements at a 20 kHz repetition-rate in hydrogen pellet-injected plasmas are presented. Signal processing methods for this measurement have been developed and electron temperature profiles with almost 70 spatial points were evaluated at time intervals of 50 [Formula: see text]s. After Raman scattering calibration, electron density profiles were derived. Fast changes in the electron temperature and density profiles within 1 ms were observed.

12.
Sci Rep ; 12(1): 6979, 2022 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-35577787

RESUMO

The preceding propagation of turbulence pulses has been observed for the first time in heat avalanche events during the collapse of the electron internal transport barrier (e-ITB) in the Large Helical Device. The turbulence and heat pulses are generated near the foot of the e-ITB and propagate to the peripheral region within a much shorter time than the diffusion timescale. The propagation speed of the turbulence pulse is approximately 10 km/s, which is faster than that of the heat pulse propagating at a speed of 1.5 km/s. The heat pulse propagates at approximately the same speed as that in the theoretical prediction, whereas the turbulence pulse propagates one order of magnitude faster than that in the prediction, thereby providing important insights into the physics of non-local transport.

13.
Rev Sci Instrum ; 92(3): 033515, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820074

RESUMO

The multipass Thomson scattering (MPTS) technique is one of the most useful methods for measuring low-electron-density plasmas. The MPTS system increases Thomson scattering (TS) signal intensities by integrating all multipass (MP) signals and improving the TS time resolution by analyzing each pass signal. The fully coaxial MPTS system developed in GAMMA 10/potential-control and diverter-simulator experiments has a polarization-based configuration with image-relaying optics. The MPTS system can enhance Thomson scattered signals for improving the measurement accuracy and megahertz-order time resolution. In this study, we develop a new MPTS system comprising a laser amplification system to obtain continuous MP signals. The laser amplification system can improve degraded laser power and return an amplified laser to the MP system. We obtain continuous MP signals from the laser amplification system by improving the laser beam profile adjuster in gas scattering experiments. Moreover, we demonstrate that more MP signals and stronger amplified MP signals can be achieved via multiple laser injections to the laser amplification system in the developed MP system comprising a laser amplification system.

14.
Rev Sci Instrum ; 92(6): 063523, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243539

RESUMO

A scalable system for real-time analysis of electron temperature and density based on signals from the Thomson scattering diagnostic, initially developed for and installed on the NSTX-U experiment, was recently adapted for the Large Helical Device and operated for the first time during plasma discharges. During its initial operation run, it routinely recorded and processed signals for four spatial points at the laser repetition rate of 30 Hz, well within the system's rated capability for 60 Hz. We present examples of data collected from this initial run and describe subsequent adaptations to the analysis code to improve the fidelity of the temperature calculations.

15.
Rev Sci Instrum ; 89(10): 10C102, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399870

RESUMO

The multi-pass Thomson scattering (MPTS) system is a useful technique for increasing the Thomson scattering (TS) signal intensities and improving the TS diagnostic time resolution. The MPTS system developed in GAMMA 10/PDX has a polarization-based configuration with an image relaying system. The MPTS system has been constructed for enhancing the Thomson scattered signals for the improvement of measurement accuracy and the megahertz sampling time resolution. However, in the normal MPTS system, the MPTS signal intensities decrease with the pass number because of the damping due to the optical components. Subsequently, we have developed a new MPTS system with the laser amplification system. The laser amplification system can improve the degraded laser power after six passes in the multi-pass system to the initial laser power. For the first time worldwide, we successfully obtained the continued multi-pass signals after the laser amplification system in the gas scattering experiments.

16.
J Dent Res ; 86(2): 163-8, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17251517

RESUMO

Dental preparation sometimes causes transient congestion, edema, and necrosis of the pulp. We hypothesized that nitric oxide (NO) is involved in the pathophysiological changes in pulp after preparation. The mRNA and protein expression of the inducible isoform of NO synthase (iNOS) was examined in murine pulp after dental preparation. The effects of NO on the proliferation, mineralization, and apoptosis of pulp cells were also studied in vitro. We found that not only iNOS, but also mRNAs for alkaline phosphatase and plasma membrane glycoprotein-1, were expressed in the pulp after preparation. NOC-18, an NO donor, suppressed the proliferation of pulp cells without inducing cell death, whereas it promoted the mineralization of cells cultured in the presence of beta-glycerophosphate, ascorbic acid, dexamethasone, and KH(2)PO(4). Under these conditions, NOC-18 induced the apoptosis of pulp cells. These results suggest that NO regulates the growth, apoptosis, and mineralization of pulp cells.


Assuntos
Preparo da Cavidade Dentária/efeitos adversos , Polpa Dentária/metabolismo , Óxido Nítrico Sintase Tipo II/biossíntese , Óxido Nítrico/fisiologia , Fosfatase Alcalina/biossíntese , Animais , Apoptose , Diferenciação Celular , Processos de Crescimento Celular/efeitos dos fármacos , Processos de Crescimento Celular/fisiologia , Células Cultivadas , Polpa Dentária/citologia , Polpa Dentária/fisiopatologia , Indução Enzimática , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Doadores de Óxido Nítrico/farmacologia , Compostos Nitrosos/farmacologia , Diester Fosfórico Hidrolases/biossíntese , Pulpite/etiologia , Pirofosfatases/biossíntese , Calcificação de Dente
17.
Rev Sci Instrum ; 87(9): 093502, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27782603

RESUMO

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (Te) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured Te and intensity of the signals. How accurate the values are depends on the electron temperature (Te) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high Te and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the Te in a wide Te range spanning over two orders of magnitude (0.01-1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the Te measurements are valid under harsh radiation conditions. This method to obtain Te can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

18.
Rev Sci Instrum ; 87(11): 11E730, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910340

RESUMO

We have developed an analysis method to improve the accuracies of electron temperature measurement by employing a fitting technique for the raw Thomson scattering (TS) signals. Least square fitting of the raw TS signals enabled reduction of the error in the electron temperature measurement. We applied the analysis method to a multi-pass (MP) TS system. Because the interval between the MPTS signals is very short, it is difficult to separately analyze each Thomson scattering signal intensity by using the raw signals. We used the fitting method to obtain the original TS scattering signals from the measured raw MPTS signals to obtain the electron temperatures in each pass.

19.
Rev Sci Instrum ; 87(11): 11E531, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910483

RESUMO

The Thomson scattering diagnostic systems are widely used for the measurements of absolute local electron temperatures and densities of fusion plasmas. In order to obtain accurate and reliable temperature and density data, careful calibrations of the system are required. We have tried several calibration methods since the second LHD experiment campaign in 1998. We summarize the current status of the calibration methods for the electron temperature and density measurements by the LHD Thomson scattering diagnostic system. Future plans are briefly discussed.

20.
Rev Sci Instrum ; 87(4): 043505, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27131672

RESUMO

This paper provides a software application of the sampling scope concept for fusion research. The time evolution of Thomson scattering data is reconstructed with a high temporal resolution during a modulated electron cyclotron resonance heating (MECH) phase. The amplitude profile and the delay time profile of the heat pulse propagation are obtained from the reconstructed signal for discharges having on-axis and off-axis MECH depositions. The results are found to be consistent with the MECH deposition.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA